An interventional study of Open-source master hearing aid in Hearing Impairment, Sensorineural, Spatial Perception and Aging, sponsored by University of South Florida. Recruiting at 1 site in United States. Open to participants aged 18 Years to 80 Years, including healthy volunteers. Per ClinicalTrials.gov, last updated 2025-12-22.
Sponsored by University of South Florida · Not applicable, Interventional, and Basic science
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 142 studies in Hearing Loss, Sensorineural with a site in United States — 35 open to participants now, 39 under way, 1 of them phase 3. Hearing Loss, Sensorineural · United States.
Among the 142 studies in Hearing Loss, Sensorineural with a site in United States, this one is the 13th largest by planned enrollment of the 116 interventional ones that give a count, is one of 13 that started in 2025, is one of 90 with no phase, reaches primary completion later than 23 of the 38 other live ones, and was the 112th registered.
349 studies on the registry are indexed under Hearing Loss, Sensorineural; 103 are open to participants now.
Browse Hearing Loss, Sensorineural studies →35 of the 142 studies in Hearing Loss, Sensorineural with a site in United States are open now. Recruiting first, the newest first:
Skylark Bio Inc. · Sites in United States
Ages 9 mo–7 yrs
Purdue University · Sites in United States
Ages 18+
Hearts for Hearing · Sites in United States
Ages 5+ · Healthy volunteers
Cochlear · Sites in United States
Ages 18+
University of Colorado, Denver · Sites in United States
Ages 45–65
A study can be open while its sites in United States have not opened yet or have stopped. Only those recruiting at a site in United States →
Of the 70 Hearing Loss, Sensorineural studies recruiting now, 39 (56%) set no upper age limit and 19 (27%) stop at 75 or younger; 26 take children under 18; 17 take healthy volunteers.
This study: 18 Years to 80 Years · all sexes · healthy volunteers too.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
142 studies; the count open now beside each. This study's row is marked.
A study in two phases is counted once above. Listed by phase, each with its combined phases: Phase 1 19 · Phase 2 12 · Phase 3 3 · Phase 4 1
First in 1998; this study’s year is marked. 13 started in 2025.
By drug class, each counting the studies that test any of its medicines:
This study's planned enrollment of 121 is above the median of 32 across 250 interventional studies indexed under Hearing Loss, Sensorineural.
Median enrollment 39 across the 116 interventional studies, 100 across the 25 observational. Of the 94 that completed or were terminated, 57 (61%) have results posted.
This tab as a report to print or save as PDF → With an account.
70 of 142 have an industry lead sponsor. The 10 most frequent:
University of South Florida is the lead sponsor of 340 studies on the registry; 65 are open to participants now.
Of its 17 completed or terminated interventional studies of FDA-regulated products, 4 (24%) have results posted.
University of South Florida has 1 study filed under Hearing Loss, Sensorineural — fewer than ten, so there is no comparison to draw.
11 of the studies in Hearing Loss, Sensorineural with a site in United States that are under way reach primary completion within a year, 0 of them phase 3. Phase 3 first, then by date:
| Study | Primary completion |
|---|---|
| NCT06960616Massachusetts Eye and Ear InfirmaryImproving Clinical Efficiency by Reducing Scheduled Follow-ups Using Cochlear America's Population Mean Mapping Strategy | 2026-11-26 |
| NCT04506853Med-El CorporationSingle-Sided Deafness and Asymmetric Hearing Loss | 2026-12-21 |
| NCT04707885Ohio State UniversityClinical Utility of Residual Hearing in the Cochlear Implant Ear | 2026-12-31 |
| NCT07081542AdventHealthComparative Analysis of Hearing Outcomes: Robotic vs. Manual Insertion of Cochlear Implants | 2027-01-31 |
| NCT05554692University of Maryland, College ParkPeripheral and Central Influences on Auditory Temporal Processing & Speech Perception in Older Cochlear Implantees | 2027-03 |
Add all 11 to your calendar (.ics) → With an account.
Among the 142 studies in Hearing Loss, Sensorineural with a site in United States, from their registry updates:
This tab as a report to print or save as PDF → With an account.
The overarching hypothesis to be evaluated using this protocol is that age-related hearing loss (ARHL) leads to shifts in the functional spatial boundaries between segregated and integrated auditory streams, and that hearing aid intervention that relies on directional processing schemes is most effective for those that have the poorest spatial sensitivity. One key component of the research design is to measure both behavioral and neurophysiological indices of an individual's spatial segregation boundary. The second key component is to measure the cost or benefit associated with hearing aid intervention in older hearing-impaired listeners. The final component is to relate cost and benefit of hearing aid intervention to spatial sensitivity measures that might predict the efficacy of clinical intervention.
STUDY DESIGN:
This is a between-group and within-subject, repeated-measures design. A detailed protocol, visit schedule, intervention methodology, and battery of outcome measures will be used to assess audition, spatial sensitivity, and pre- and post-intervention of behavioral and neurophysiological indices of spatial segregation. The study includes two control groups (young normal-hearing [YNH] and older normal-hearing [ONH]) and the test group (older hearing-impaired [OHI]) with three aided interventions: omnidirectional processing, fixed directional processing, and variable directional processing. There are two study arms: Arm 1 tests spatial segregation in the presence of a fixed masker in front of the listener; Arm 2 tests spatial segregation in the presence of a diffuse masker presented from three (narrow) or seven (wide) loudspeakers surrounding the frontal spatial hemisphere.
DESCRIPTION OF THE PROTOCOL:
All listeners receive an intake protocol consisting of standard clinical and laboratory measures of auditory function (roughly two-hour visit). The baseline measures include audiogram, loudness discomfort levels (LDLs), middle ear status (tympanometry), acoustic reflex thresholds, and words in noise. Pre-treatment measures of spatial sensitivity are measured in a single two-hour visit. Measures include the minimum audible angle (MAA), speech localization error, and spatial release from masking. The Pre-treatment measures of the spatial segregation boundary are conducted in a single two-hour visit. Post-treatment measures (OHI group only) are counter balanced across three additional two-hour visits. Pre- and post-treatment measures of the spatial segregation boundary include measures of a fixed spatial separation between target and masker speech, and a roving (moving) target condition at multiple spatial separations spanning 0° to 90° in 15° steps.
DELIVERY OF INTERVENTION:
Hearing aid fitting: The standard-of-care intervention for ARHL is amplification via hearing aids and this is the intervention to be used in this study. The fitting procedures and any necessary troubleshooting or adjustments will follow the Auditory Neurosciences \& Technology Laboratory device Standard Operating Procedures (dSOP) manual for hearing aid fitting and counseling. This manual is based upon guidelines of the American Speech-Language-Hearing Association and the American Academy of Audiology. Devices are fit wirelessly using a clinical-style graphical user interface for device programming in conjunction with real-ear verification. The audiologist (Dr. Secor) will fit the OHI subjects with the hearing instruments prior to the experiments. To avoid the possibility that independent amplitude compression at the two ears can reduce ILD cues, aids will be fit with a linear prescription. Because the sound levels in the experiments are in a restricted range near 65 dB the investigators will use NAL2 prescription for 65 dB input levels as verified using probe-microphone measures (Verifit 2, Audioscan).
Hearing aids: In order to better generalize results and control for a wide array of potentially hidden digital processing effects by device manufacturers, the investigators will use open-source, research-grade devices made possible through the NIH-funded open Master Hearing Aid consortium (openMHA). The open-source hardware design includes behind-the-ear (BTE), receiver-in-the-canal (RIC) instruments (Sonion) wired to a multi-channel audio board (Cape4all; 16 kHz sampling) attached to a portable main board (Beaglebone Black Wireless). The lightweight hardware is worn around the user's neck. Beamforming (fixed or variable) is accomplished in openMHA using a binaural minimum variance distortionless response (MVDR) algorithm that attempts to minimize any diffuse or spatially separated noise contributions from a target speech source.
Hearing aid conditions: In a within-subject design, the OHI group will be tested (per study arm) in four device configurations: (1) unaided, (2) aided with omnidirectional microphones, (3) aided with fixed directional processing, and (4) aided with variable directional processing. The fixed binaural beamformer has a relatively narrow spatial filter at the front, whereas the variable binaural beamformer is steered to the speech direction in real time. For the variable condition, real time speech localization is based on a priori knowledge of where the speech is presented from instead of employing an adaptive speech locator as used in real devices. This condition, therefore, represents the best achievable spatial filtering given perfect source localization and zero lag time between source localization and beam steering.
SAMPLE SIZE AND DATA ANALYSIS METHODS:
Power analyses. Based on preliminary data and reports with similar analyses in the literature, significant effect sizes are expected to have a minimum of ηp2 = 0.19 for repeated measures analysis of variance (rmANOVA) testing. In Arm 1, computing sample size for the smallest possible effects (ηp2 = 0.19), alpha (0.05), power (0.95), with moderate-to-strong correlation among repeated measures (0.75) indicates that 38 listeners per group are needed for each experiment (≥3 repeated measures; G*Power v3.1.9.2). In Arm 2, the investigators will also use multiple regression to measure the relationship between spatial acuity and hearing aid benefit. For a small-to-medium effect size (f2 = 0.3), 55 subjects are needed.
Analytic plan. Descriptive and graphical statistics will be used to summarize the data on all participants and appropriate transformations, or non-parametric methods will be applied, as necessary. The investigators will use rmANOVAs to analyze the results from the behavioral data and cortical synchronization results at the group level. Pearson's correlation coefficients will be Z-transformed (Fisher) before statistical analyses. To protect against Type I error, the principal analyses are designed to answer clearly stated major research hypotheses and are based on well-specified dependent variables. All tests will be two-tailed at alpha=0.05, with Holm-Bonferroni adjustment for multiple comparisons. Where appropriate, rmANOVA's will be used to measure group differences in our intake psychoacoustic measures, and if the investigators observe statistical group differences, they will be used as covariates.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Target candidates for this study will be 38 young normal-hearing (YNH), 38 older normal-hearing (ONH), and 55 older hearing-impaired (OHI) subjects. Eligible NH listeners will have ≤20 dB HL at octave frequencies from 0.25 to 4 kHz and ≤30 dB HL up to 8 kHz. Eligible HI listeners will have bilateral (symmetric), moderate sensorineural hearing loss characterized by pure-tone thresholds between 35 to 50 dB HL from 0.25 to 2 kHz and 50 to 70 dB HL between 3 and 8 kHz. Age is restricted from 60 to 80 years for the older listening groups and from 18 to 35 for younger listeners. A balance of male and female participants will be recruited to assess sex as a biological variable in the data analyses. This age range for older listeners was chosen to be maximally inclusive of potential presbycusic participants, to promote generality of the results, and to facilitate uniform sampling within this age range. The investigators want to avoid the scientific need to stratify by age, which would make the scope of the project unmanageable given the constraints of this five-year award. The investigators have no evidence that lower or higher ages would affect aided intervention. Thus, inclusion of a larger age range would weaken the rigor of the investigation and complicate interpretation of the findings. The target range of hearing loss was chosen for similar reasons, reflecting the largest segment of older adults with hearing loss while avoiding the need to stratify by hearing loss to evaluate the stated hypotheses.
Additional Inclusion Criteria for HI group:
Exclusion Criteria:
Exclusion criteria include conditions for which one could anticipate that hearing or cognitive status might change markedly during the course of study. To hedge against such changes, participants will be excluded if they have undergone clinical management for any of the following in the past 12 months:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Short tests of memory and thinking, each scored out of 30. Lower scores suggest more difficulty; criteria give a range, either to include people with memory problems or to leave them out.
MMSE and MoCA
Short tests of memory and thinking, each scored out of 30. Lower scores suggest more difficulty; criteria give a range, either to include people with memory problems or to leave them out.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Test group, tested with and without the intervention (openMHA device) fit to their audiometric profile.
Device: Open-source master hearing aid
Control group, no intervention.
Control group, no intervention.
The investigators will administer the intervention by fitting the device to the participant's audiometric profile. Testing will be counter-balanced across conditions with half the conditions requiring no intervention and the other half with the intervention.
Also known as: openMHA
Digit Identification
The investigators will measure the behavioral accuracy of listeners identifying digits in a continuous stream of monosyllabic words. In a roughly two-minute run, about 30 digits are presented and listeners are tasked with immediately identifying each one as they are presented. The target stream can be stationary or moving in space, and the masker speech stream can be stationary at the front loudspeaker or diffused around the front speaker (i.e., played from multiple speakers). For static or fixed spatial separations between target and masker (between 0° and 90°), the digit identification accuracy is in percent correct. For multiple spatial separations, the investigators can derive a psychometric curve from which the investigators can extract the spatial separation needed to get a desired percent correct, like 75%, and the investigators call this the Spatial Segregation Boundary (in degrees).
Time frame: Acute: Outcome measures are collected with and without treatment over multiple sessions spanning roughly 2 weeks.
Neural Segregation
Using two neural entrainment models (forward and backward), the investigators will measure the probability that the brain is able to encode attended speech during a speech-on-speech task. Listeners are tasked with identifying digits during the task carried by either the male or female speaker. The neural entrainment models will be conducted for each spatial separation (between 0° and 90°), from which the investigators will derive a single probability metric for fixed spatial separations or for multiple locations, revealing a neurometric curve. From the neurometric curve, the investigators can extract the spatial separation needed to get a desired percent correct, like 75%, and the investigators call this the Neural Spatial Segregation Boundary (in degrees).
Time frame: Acute: Outcome measures are collected with and without treatment over multiple sessions spanning roughly 2 weeks.
Minimum Audible Angle (MAA)
psychophysical test of minimum audible angle at the front (0°) and at the right side (+90°) using a vector-based amplitude panning method for titrating on presentation angle. Listeners perform an adaptive tracking test in which they indicate whether broadband white noises (0.1-8 kHz) were to the left or right of the 0° reference or front or behind the 90° reference. The noise stimuli are a train of three 100-ms bursts of Gaussian noise, with a 500-ms silence between bursts. A 3-down/1-up adaptive procedure is used to determine the reproduction angle for the next trial, which could be smaller or larger than the previous separation, to find the 79.4% correct point on a psychometric function. The angular step sizes in the 0° MAA measurement are determined by Parameter Estimation by Sequential Testing (PEST).
Time frame: Acute: Outcome measures are collected with and without treatment over multiple sessions spanning roughly 2 weeks.
Speech Localization Error
Listeners are presented with 130 monosyllable words, each presented from 1 of 13 loudspeakers spanning (-90 to +90° in 15° steps). After each presentation, listeners indicate point in the direction from where they heard the stimulus come. Localization error is calculated as the average error (in degrees) that listeners achieve per source angle.
Time frame: Acute: Outcome measures are collected with and without treatment over multiple sessions spanning roughly 2 weeks.
Fixed Spatial Release from Masking
To quantify a fixed spatial release-from-masking (SRM) point, listeners will perform an adaptive tracking task. The SNR between target and masker speech streams will be fixed to -3 dB re the co-located SRT50 (separately tested as a method for setting individual levels in the digit identification test), and the spatial separation between the target and masker will be adaptively changed to converge on a 3dB-SRM until threshold is reached. This will identify the amount of spatial separation between target and masker required to achieve a 3-dB improvement in SNR over a co-located condition.
Time frame: Acute: Outcome measures are collected with and without treatment over multiple sessions spanning roughly 2 weeks.
Pure-tone Air Threshold (PTac)
Audibility thresholds in dB HL for pure tone stimuli at octave frequencies from 250 to 8000 Hz measured by air conduction via audiometer and audiometric headphones.
Time frame: Pre-treatment: Outcomes are collected on first day of study without treatment
Bone Conduction Threshold (PTbc)
Audibility thresholds in dB HL for pure tone stimuli at octave frequencies from 250 to 8000 Hz measured by bone conduction via audiometer and audiometric headphones.
Time frame: Pre-treatment: Outcomes are collected on first day of study without treatment
Wideband Tympanometry (Equivalent Ear Canal Volume)
Wideband tympanometry measures will be obtained using the Interacoustics Titan clinical immittance system to ensure consistent middle ear function prior to each test session and to obtain Equivalent Ear Canal Volume (ECV).
Time frame: Pre-treatment: Outcomes are collected on first day of study without treatment
Wideband Tympanometry (Static Peak Pressure)
Wideband tympanometry measures will be obtained using the Interacoustics Titan clinical immittance system to ensure consistent middle ear function prior to each test session and to obtain static peak pressure.
Time frame: Pre-treatment: Outcomes are collected on first day of study without treatment
Wideband Tympanometry (Resonant Frequency)
Wideband tympanometry measures will be obtained using the Interacoustics Titan clinical immittance system to ensure consistent middle ear function prior to each test session and to obtain middle ear resonant frequency measures.
Time frame: Pre-treatment: Outcomes are collected on first day of study without treatment
Plan to share: Undecided — have not decided yet.
No publications or documents are linked to this record.
Started Nov 2025 (actual). Primary completion is estimated for Mar 2028, 27 months after the start.
Of 81 non-industry interventional studies with no phase under Hearing Loss, Sensorineural, half reached primary completion within 32 months of starting (the median), counting those still running; a quarter within 18 and three quarters within 49. This study's planned 27 months is below that.
Counting every sponsor, half of 161 studies reached it within 22 months; a quarter within 6 and three quarters within 44.
How these figures are worked out, and which studies are left out of them.
Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.
No contact was published for this record. The registry link below has the sponsor’s details.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.