ClinicalTrials.gg
Active, not recruitingNCT04707885Updated Oct 20, 2026

Clinical Utility of Residual Hearing in the Cochlear Implant Ear

An interventional study of Electrocochleography in Hearing Loss, Sensorineural, Hearing Loss and Hearing Loss, Bilateral, sponsored by Ohio State University. Active, not recruiting at 5 sites in United States. Open to participants aged 18 Years to 79 Years. Per ClinicalTrials.gov, last updated 2026-10-20.

Sponsored by Ohio State University · Not applicable, Interventional, and Treatment

How we know

Updated Oct 20, 2026Now Active, not recruitingGo to Updates ↓

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Phase
Not applicable
Study type
Interventional
Enrollment
40
Allocation
Randomized
Ages
18 Years to 79 Years
Sex
All
01

Where this study stands

Counted across the records on this site · 2026-11-25

Among 142 studies in Hearing Loss, Sensorineural with a site in United States — 35 open to participants now, 39 under way, 1 of them phase 3. Hearing Loss, Sensorineural · United States.

Planned enrollment
53rd of 116
40 · median 39
Started
2021
with 17 others
No phase
90 of 142
22 open now
Primary completion
2026-12
later than 11 of 38 live
Registered
70th of 142
by date

Among the 142 studies in Hearing Loss, Sensorineural with a site in United States, this one is the 53rd largest by planned enrollment of the 116 interventional ones that give a count, is one of 18 that started in 2021, is one of 90 with no phase, reaches primary completion later than 11 of the 38 other live ones, and was the 70th registered.

Hearing Loss, Sensorineural

349 studies on the registry are indexed under Hearing Loss, Sensorineural; 103 are open to participants now.

Browse Hearing Loss, Sensorineural studies →

Open to participants now

35 of the 142 studies in Hearing Loss, Sensorineural with a site in United States are open now. Recruiting first, the newest first:

30 more — sign in →

All 35 open studies →

A study can be open while its sites in United States have not opened yet or have stopped. Only those recruiting at a site in United States →

Who these studies take

Of the 70 Hearing Loss, Sensorineural studies recruiting now, 39 (56%) set no upper age limit and 19 (27%) stop at 75 or younger; 26 take children under 18; 17 take healthy volunteers.

This study: 18 Years to 79 Years · all sexes · no healthy volunteers.

The full table on the hub →

This tab as a report to print or save as PDF → With an account.

Was this useful?
Get alerts for this landscapeDownload CSVNarrow it in search →With an account: a weekly mail of what changed among 142 studies in Hearing Loss, Sensorineural with a site in United States, or all of them as a file.
02

Study summary

The current study is a randomized multi-center clinical trial that investigates the role an intraoperative hearing monitoring system (electrocochleography) has on helping to save residual hearing in patients undergoing cochlear implantation (CI).

Read the detailed description

The clinical importance of residual acoustic hearing in CI remains unclear. It is estimated that only five percent of adult candidates undergo CI. A major barrier is the loss of residual hearing associated with surgery, meaning most patients lose any or all residual hearing as a result of the CI surgery, especially since the majority of today's candidates do not suffer from complete deafness. Hence, many candidates are faced with the decision to relinquish their remaining acoustic hearing in exchange for electric hearing via the CI, as CI surgery often results in complete loss of any residual hearing. However, recent developments in hearing monitoring systems during CI surgery have shown promise for providing the surgeon with live feedback of how the cochlear implant insertion process is proceeding, allowing the surgeon to make intraoperative adjustments during the insertion, potentially minimizing any trauma caused by the insertion of the implant, ultimately helping preserve residual hearing. This ultimately could lead to improvements in the rates of hearing preservation. Therefore, the current study seeks to investigate: 1) the advantage of using a hearing monitoring system (electrocochleography) monitoring guided CI surgery on hearing preservation rates, 2) determine the benefit that hearing aid/cochlear implant combined hearing provides participants over non-hearing preservation CI (electric-only stimulation from the CI) on measures of speech perception and quality of life.

03

Conditions studied

  • Hearing Loss, Sensorineural
  • Hearing Loss
  • Hearing Loss, Bilateral
04

Who can participate

Ages eligible
18 Years to 79 Years
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  1. Provision of signed and dated form.
  2. Adults, males and females, ages 18 -79 who have a bilateral sensorineural hearing loss with postlingual onset.
  3. Minimum of 30 days experience with appropriately fit binaural amplification (standardized National Acoustic Laboratories (NAL) fitting method) verified with real ear measurements within 5 dB SPL of targets.
  4. Limited benefit from conventional amplification in the best aided condition as defined by test scores of:

    1. The ear to implanted: Consonant-nucleus-consonant (CNC) words ≤ 60% or AzBio sentences (+10, +5 dB SNR ≤ 60% correct)
    2. Contralateral ear: ≤ 80% on CNC words or AzBio sentences (+10, +5 dB SNR ≤ 80% correct)
  5. Low frequency Pure Tone Average (PTA- 125, 250, 500 Hz) ≤ 55 dB HL in the ear to be implanted.
  6. Severe to profound mid to high-frequency sensorineural hearing loss (threshold average of 1000, 2000, 3000, and 4000 Hz ≥75 dB HL) in the ear to be implanted.
  7. Low frequency PTA ≤ 55 dB HL sloping to moderately severe to profound mid-to high frequency sensorineural hearing loss (threshold average of 1000, 2000, 3000, 4000 Hz ≥ 60 dB) in the contralateral ear.
  8. Proficient in English.
  9. Undergoing implantation with a current generation CI device from either Cochlear Limited or Advanced Bionics AG.

    1. Cochlear Limited devices include: Nucleus CI612, CI622, CI632, CI624
    2. Advanced Bionics AG devices include: HiFocus SlimJ, Mid-Scala
  10. Stated willingness and ability to complete testing and all associated study visits.

Exclusion criteria

Exclusion Criteria:

  1. Previous cochlear implantation.
  2. Prelingual onset of hearing loss.
  3. Abnormal inner ear anatomy on CT imaging.
  4. Auditory neuropathy spectrum disorder.
  5. Retrocochlear pathology such as a vestibular schwannoma or stroke.
  6. Unwillingness or inability to comply with all requirements including the randomization process.
  7. Additional medical, or social barriers that would prevent completion of all study requirements.
  8. Medical condition for surgery.
  9. Device selection of Med El CI (per the patient's selection).
Terms in these criteria, in plain language(3)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

Investigational drug or device

A drug or device being studied in a clinical trial.

It may be new, or already approved and being studied for another use, dose or form. Criteria often leave out people who took part in another study of one within a recent period, commonly 30 days or five half-lives.

Contraindication

A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.

05

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Randomized
Intervention model
Parallel assignment
Masking
None (open label)
Enrollment
40 participants (estimated)

Study arms

  • Experimental
    ECochG monitoring

    For those randomized to the experimental group, the CI surgery will proceed in a standard fashion. However, the surgeon will utilize ECochG-guided monitoring by placing the external device coil and processor over the receiver/stimulator of the implanted components. Also, a sound applicator (i.e. speaker) will be placed in the external auditory canal by the surgeon. During electrode insertion the surgeon will utilize the ECochG feedback to adjust insertion if needed. That is, once the electrode has been inserted at least 75% (75% of the electrode contacts inside the cochlea), the surgeon may proceed to full insertion if indicated during ECochG feedback or may modify and/or cease electrode insertion if indicated by the ECochG feedback in attempts to preserve RH.

    Device: Electrocochleography

  • No intervention
    Control Group

    For those randomized to the control group, they will receive their CI per the standard of care. That is, all procedures that take place during a routine CI surgery will be the same for those in the control group. As such, no ECochG monitoring will be performed. However, all study surgeons will be asked to adhere to soft surgical principles (non-traumatic cochlear opening, slow electrode insertions) to enhance HP outcomes even in the absence of intraoperative ECochG monitoring. Further, the standard of care for cochlear implantation is to perform full electrode insertions with all electrode contacts inside of the cochlea. Thus, for subjects in the control group, surgeons will be asked to perform full electrode insertions.

Interventions

  • DeviceElectrocochleography

    The use of ECochG monitoring will be employed. This will be conducted intraoperatively during the entire portion of the CI electrode insertion component. For the purposes of this clinical trial, the stimulus will consist of a 500 Hz tone burst presented at \~105-110 dB SPL. This was chosen due to the time and resource limitations in the operating room. Hence, the surgical team can only utilize a very limited dataset for intraoperative decision making and previous studies have demonstrated that 500 Hz stimulation offers the most robust, reliable, and useful ECochG signal during electrode insertions.

    Also known as: ECochG

06

What researchers measure

Primary outcomes

  1. Preservation Advantage

    Determine the hearing preservation advantage, by measuring low tone audiometry at the 3, 6,12 and 24 month timepoints, in hertz.

    Time frame: 3, 6, 12, 24 months

07

Study locations

5 sites
08

References and documents

Publications

  • Eggermont JJ. Ups and Downs in 75 Years of Electrocochleography. Front Syst Neurosci. 2017 Jan 24;11:2. doi: 10.3389/fnsys.2017.00002. eCollection 2017. PubMed 28174524 ↗
  • Gantz BJ, Dunn C, Oleson J, Hansen M, Parkinson A, Turner C. Multicenter clinical trial of the Nucleus Hybrid S8 cochlear implant: Final outcomes. Laryngoscope. 2016 Apr;126(4):962-73. doi: 10.1002/lary.25572. Epub 2016 Jan 12. PubMed 26756395 ↗
  • Gantz BJ, Hansen MR, Turner CW, Oleson JJ, Reiss LA, Parkinson AJ. Hybrid 10 clinical trial: preliminary results. Audiol Neurootol. 2009;14 Suppl 1(Suppl 1):32-8. doi: 10.1159/000206493. Epub 2009 Apr 22. PubMed 19390173 ↗
  • Gautschi-Mills K, Khoza-Shangase K, Pillay D. Preservation of residual hearing after cochlear implant surgery: an exploration of residual hearing function in a group of recipients at cochlear implant units. Braz J Otorhinolaryngol. 2019 May-Jun;85(3):310-318. doi: 10.1016/j.bjorl.2018.02.006. Epub 2018 Mar 24. PubMed 29631897 ↗
  • Gifford RH, Dorman MF, Shallop JK, Sydlowski SA. Evidence for the expansion of adult cochlear implant candidacy. Ear Hear. 2010 Apr;31(2):186-94. doi: 10.1097/AUD.0b013e3181c6b831. PubMed 20071994 ↗
  • Gstoettner WK, Baumgartner WD, Franz P, Hamzavi J. Cochlear implant deep-insertion surgery. Laryngoscope. 1997 Apr;107(4):544-6. doi: 10.1097/00005537-199704000-00022. No abstract available. PubMed 9111389 ↗
  • Gstoettner W, Helbig S, Settevendemie C, Baumann U, Wagenblast J, Arnoldner C. A new electrode for residual hearing preservation in cochlear implantation: first clinical results. Acta Otolaryngol. 2009 Apr;129(4):372-9. doi: 10.1080/00016480802552568. PubMed 19140036 ↗
  • Campbell L, Kaicer A, Sly D, Iseli C, Wei B, Briggs R, O'Leary S. Intraoperative Real-time Cochlear Response Telemetry Predicts Hearing Preservation in Cochlear Implantation. Otol Neurotol. 2016 Apr;37(4):332-8. doi: 10.1097/MAO.0000000000000972. PubMed 26859542 ↗
  • Harris MS, Riggs WJ, Giardina CK, O'Connell BP, Holder JT, Dwyer RT, Koka K, Labadie RF, Fitzpatrick DC, Adunka OF. Patterns Seen During Electrode Insertion Using Intracochlear Electrocochleography Obtained Directly Through a Cochlear Implant. Otol Neurotol. 2017 Dec;38(10):1415-1420. doi: 10.1097/MAO.0000000000001559. PubMed 28953607 ↗
  • Hodges AV, Schloffman J, Balkany T. Conservation of residual hearing with cochlear implantation. Am J Otol. 1997 Mar;18(2):179-83. PubMed 9093674 ↗
  • Koka K, Saoji AA, Litvak LM. Electrocochleography in Cochlear Implant Recipients With Residual Hearing: Comparison With Audiometric Thresholds. Ear Hear. 2017 May/Jun;38(3):e161-e167. doi: 10.1097/AUD.0000000000000385. PubMed 27879487 ↗
  • Lan KK, DeMets DL. Changing frequency of interim analysis in sequential monitoring. Biometrics. 1989 Sep;45(3):1017-20. PubMed 2790114 ↗
  • Pillsbury HC 3rd, Dillon MT, Buchman CA, Staecker H, Prentiss SM, Ruckenstein MJ, Bigelow DC, Telischi FF, Martinez DM, Runge CL, Friedland DR, Blevins NH, Larky JB, Alexiades G, Kaylie DM, Roland PS, Miyamoto RT, Backous DD, Warren FM, El-Kashlan HK, Slager HK, Reyes C, Racey AI, Adunka OF. Multicenter US Clinical Trial With an Electric-Acoustic Stimulation (EAS) System in Adults: Final Outcomes. Otol Neurotol. 2018 Mar;39(3):299-305. doi: 10.1097/MAO.0000000000001691. PubMed 29342054 ↗
  • Saoji AA, Patel NS, Carlson ML, Neff BA, Koka K, Tarigoppula VSA, Driscoll CLW. Multi-frequency Electrocochleography Measurements can be Used to Monitor and Optimize Electrode Placement During Cochlear Implant Surgery. Otol Neurotol. 2019 Dec;40(10):1287-1291. doi: 10.1097/MAO.0000000000002406. PubMed 31644474 ↗
  • Scheperle RA, Tejani VD, Omtvedt JK, Brown CJ, Abbas PJ, Hansen MR, Gantz BJ, Oleson JJ, Ozanne MV. Delayed changes in auditory status in cochlear implant users with preserved acoustic hearing. Hear Res. 2017 Jul;350:45-57. doi: 10.1016/j.heares.2017.04.005. Epub 2017 Apr 12. PubMed 28432874 ↗
  • Skinner MW, Holden TA, Whiting BR, Voie AH, Brunsden B, Neely JG, Saxon EA, Hullar TE, Finley CC. In vivo estimates of the position of advanced bionics electrode arrays in the human cochlea. Ann Otol Rhinol Laryngol Suppl. 2007 Apr;197:2-24. PubMed 17542465 ↗

Individual participant data

Plan to share: No

09

Timeline

1 registry update since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Started Nov 2021 (actual). Primary completion is estimated for Dec 2026, 61 months after the start.

Of 81 non-industry interventional studies with no phase under Hearing Loss, Sensorineural, half reached primary completion within 32 months of starting (the median), counting those still running; a quarter within 18 and three quarters within 49. This study's planned 61 months is above that.

Counting every sponsor, half of 161 studies reached it within 22 months; a quarter within 6 and three quarters within 44.

How these figures are worked out, and which studies are left out of them.

Registered
Jan 11, 2021
First posted
Jan 13, 2021
StartActual
Nov 10, 2021
Primary completionEst.
Dec 31, 2026
CompletionEst.
Dec 31, 2027
Last update
Oct 20, 2026
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
Status
Recruiting→Active, not recruiting
changed Oct 20, 2026
Show all 1 update
  1. Oct 20, 2026
    Recruiting→Active, not recruiting
    + 4 other changes: verification date, oversight details, contact details and site details

From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗

10

Registry details

Key details

Study ID
NCT04707885
Responsible party
Oliver Adunka (Professor, Ohio State University) — Principal investigator
First posted
Jan 13, 2021
Start date
Nov 10, 2021
Primary completion
Dec 31, 2026 (estimated)
Completion
Dec 31, 2027 (estimated)
Last update
Oct 20, 2026

Study contacts

Oliver Adunka, MD
principal investigator · Ohio State University
Amanda Ortmann, PhD
principal investigator · Washington University School of Medicine

Oversight

Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is active, not recruiting, as verified in Oct 2026. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion