An interventional study of CMT Vessel-X® Bone Filling Container System and CMT Manual Orthopedic Surgical Instruments in Osteoporosis and Osteoporotic Vertebral Compression Fractures, sponsored by Juin-Hong Cherng. Recruiting at 2 sites in Taiwan. Open to participants aged 40 Years to 95 Years. Per ClinicalTrials.gov, last updated 2026-06-24.
Sponsored by Juin-Hong Cherng · Not applicable, Interventional, and Treatment
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 56 studies in Osteoporosis with a site in Taiwan — 12 open to participants now, 16 under way, none of them phase 3. Osteoporosis · Taiwan.
Among the 56 studies in Osteoporosis with a site in Taiwan, this one is the 14th largest by planned enrollment of the 33 interventional ones that give a count, is one of 5 that started in 2021, is one of 18 with no phase, reaches primary completion later than 10 of the 15 other live ones, and was the 56th registered.
1,602 studies on the registry are indexed under Osteoporosis; 209 are open to participants now.
Browse Osteoporosis studies →12 of the 56 studies in Osteoporosis with a site in Taiwan are open now. Recruiting first, the newest first:
National Taiwan University Hospital · Sites in Taiwan
Ages 50–85 · Women only
Taichung Veterans General Hospital · Sites in Taiwan
Ages 40–80 · Healthy volunteers
National Taiwan University Hospital · Sites in Taiwan
Ages 50–85
National Taiwan University Hospital · Sites in Taiwan
Ages 50–80 · Women only
National Taiwan University Hospital · Sites in Taiwan
Ages 50–90 · Women only
A study can be open while its sites in Taiwan have not opened yet or have stopped. Only those recruiting at a site in Taiwan →
Of the 133 Osteoporosis studies recruiting now, 77 (58%) set no upper age limit and 20 (15%) stop at 75 or younger; 9 take children under 18; 36 take healthy volunteers.
This study: 40 Years to 95 Years · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
56 studies; the count open now beside each. This study's row is marked.
First in 2000; this study’s year is marked. 5 started in 2021.
By drug class, each counting the studies that test any of its medicines:
This study's planned enrollment of 146 is above the median of 88 across 1,084 interventional studies indexed under Osteoporosis.
Median enrollment 101 across the 33 interventional studies, 200 across the 22 observational. Of the 26 that completed or were terminated, 2 (8%) have results posted.
This tab as a report to print or save as PDF → With an account.
6 of 56 have an industry lead sponsor. The 10 most frequent:
Juin-Hong Cherng is the lead sponsor of 2 studies on the registry; 2 are open to participants now.
Juin-Hong Cherng has 1 study filed under Osteoporosis — fewer than ten, so there is no comparison to draw.
2 of the studies in Osteoporosis with a site in Taiwan that are under way reach primary completion within a year, 0 of them phase 3. Phase 3 first, then by date:
| Study | Primary completion |
|---|---|
| NCT02635022National Taiwan University HospitalFragility Fracture Liaison Service and Anti-osteoporosis Medication Monitoring Service Study | 2026-12 |
| NCT07665424Juin-Hong CherngSafety and Efficacy Clinical Trial of the Vessel-X® Bone Filling Container System | 2026-12-31 |
Add all 2 to your calendar (.ics) → With an account.
Among the 56 studies in Osteoporosis with a site in Taiwan, from their registry updates:
Nothing recorded among them since 2026-09-25.
This tab as a report to print or save as PDF → With an account.
Osteoporotic vertebral compression fractures (OVCFs) are a common and serious complication of osteoporosis, particularly among elderly and postmenopausal patients. OVCFs may result in severe pain, functional impairment, spinal deformity, and reduced quality of life. Conventional conservative treatments, including bed rest, analgesics, and bracing, may provide limited symptom relief. Minimally invasive vertebral augmentation procedures, such as vertebroplasty and kyphoplasty, have been widely used to improve clinical outcomes; however, risks including bone cement leakage and incomplete vertebral restoration remain concerns.
The Vessel-X® Bone Filling Container System, manufactured by Central Medical Technologies Inc. (CMT), is a third-generation vesselplasty technology designed for percutaneous vertebral augmentation procedures. The system utilizes an implantable biocompatible polyethylene terephthalate (PET) container with a microporous structure for controlled bone cement delivery. The implant remains within the vertebral body after cement injection and is designed to reduce cement leakage while maintaining vertebral height restoration and pain relief.
This post-market clinical study evaluates the safety and clinical effectiveness of the Vessel-X® Bone Filling Container System at two medical centers in Taiwan with a total target enrollment of 146 subjects:
Tri-Service General Hospital (TSGH): 86 subjects randomized in a 1:1 ratio to the experimental and control groups.
Taoyuan General Hospital, Ministry of Health and Welfare (TYGH): 60 subjects randomized in a 1:1 ratio to the experimental and control groups.
The primary objective is to evaluate the safety of the device by assessing the incidence of unanticipated serious adverse device effects (USADEs). Secondary objectives include evaluation of pain reduction measured by the Visual Analogue Scale (VAS), functional recovery assessed by the Oswestry Disability Index (ODI), and radiographic outcomes including vertebral height restoration and kyphotic deformity correction.
Background and Rationale:
Osteoporotic vertebral compression fractures (OVCFs) are a common and serious complication of osteoporosis, particularly among elderly and postmenopausal patients. OVCFs may result in severe pain, functional impairment, spinal deformity, and reduced quality of life. Conventional conservative treatments, including bed rest, analgesics, and bracing, may provide limited symptom relief. Minimally invasive vertebral augmentation procedures, such as vertebroplasty and kyphoplasty, have been widely used to improve clinical outcomes; however, risks including bone cement leakage and incomplete vertebral restoration remain concerns.
The Vessel-X® Bone Filling Container System, manufactured by Central Medical Technologies Inc. (CMT), is a third-generation vesselplasty technology designed for percutaneous vertebral augmentation procedures. The system utilizes an implantable biocompatible polyethylene terephthalate (PET) container with a microporous structure for controlled bone cement delivery. The implant remains within the vertebral body after cement injection and is designed to reduce cement leakage while maintaining vertebral height restoration and pain relief.
This is a prospective, open-label, randomized, parallel-controlled, non-inferiority clinical trial conducted in Taiwan to evaluate the safety and clinical effectiveness of this system (Model: BVFT-UP01-D20, Approved No. 005889) compared with conventional vertebroplasty performed using manual orthopedic surgical instruments (Approved No. 005698), both manufactured by CMT. Both groups will utilize the same radiopaque bone cement ("Tecres" Osteopal V) for the therapeutic procedures.
Hypothesis:
The study is designed as a non-inferiority trial. The primary hypothesis is that the incidence of unanticipated serious adverse device effects (USADEs) in the Vessel-X® group is not higher than that in the control group. For efficacy, the experimental group is hypothesized to be non-inferior to the control group regarding pain relief, disability improvement, and radiographic parameters, with a pre-specified non-inferiority margin of -15% for the difference in fused effective rates between the two groups.
Patient Enrollment and Site Allocation:
To achieve the clinical evaluation objectives, a total of up to 146 subjects will be recruited across participating medical centers in Taiwan. The target sample size is allocated specifically as 86 subjects from Tri-Service General Hospital (TSGH) and 60 subjects from Taoyuan General Hospital (TYGH). Subjects at each site will be allocated to the experimental and control groups using a 1:1 randomization scheme.
Surgical Procedure Protocol:
All surgical procedures will be performed under real-time fluoroscopic (C-arm) guidance using a standard unilateral transpedicular approach:
Experimental Group: The Vessel-X® PET biocompatible microporous container will be deployed into the vertebral body, and bone cement will be injected in a controlled manner, allowing partial cement interdigitation through the micropores. The container remains as a permanent implant.
Control Group: Conventional vertebroplasty will be performed using CMT's standard manual orthopedic surgical instruments to deliver the bone cement directly.
In both groups, fluoroscopic monitoring is maintained throughout the injection, and cement delivery will be discontinued immediately if any cement leakage or breach is observed.
Clinical Evaluation Timelines:
Subjects will participate in the study for a total duration of 13 months, consisting of a 1-month screening period, the surgical intervention (Day 1), and a 12-month post-operative follow-up period. Follow-up visits are scheduled at Day 8 (8±2 days), Month 1 (31±2 days), Month 3 (91±15 days), Month 6 (181±15 days), Month 9 (271±15 days), and Month 12 (361±15 days).
Outcome Assessments:
Safety Assessment (Primary Endpoint, ITT Population): Evaluated by the incidence of adverse events, complications, bone cement leakage, and new-onset neurological deficits.
Efficacy Assessment (Secondary Endpoints, PP \& FAS Populations): Evaluated by changes from baseline to each follow-up timepoint in Visual Analogue Scale (VAS) scores for pain, Oswestry Disability Index (ODI) scores for functional disability, and radiographic parameters (anterior vertebral height, midline vertebral height, and kyphotic Cobb's angle)
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Subjects must meet all of the following criteria to be eligible for enrollment in this study:
Exclusion Criteria:
Subjects who meet any of the following criteria will be excluded from participation in this study:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
The top of the normal range for a blood test, as set by the laboratory that runs it. Each lab prints its own range next to your result.
“≤ 2.5 × ULN” means the result can be up to two and a half times that top value.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
An allergy, or another reaction of the immune system, to a substance. “Hypersensitivity to the study drug” means a known allergic reaction to it — not every side effect a medicine can have.
ULN (upper limit of normal)
The top of the normal range for a blood test, as set by the laboratory that runs it. Each lab prints its own range next to your result.
“≤ 2.5 × ULN” means the result can be up to two and a half times that top value.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Hypersensitivity
An allergy, or another reaction of the immune system, to a substance. “Hypersensitivity to the study drug” means a known allergic reaction to it — not every side effect a medicine can have.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Subjects undergo percutaneous vertebral augmentation using the CMT Vessel-X® Bone Filling Container System (Model: BVFT-UP01-D20). Under fluoroscopic guidance, a unilateral transpedicular approach is used to access the fractured vertebral body. The microporous PET Vessel-X® Bone Filling Container is deployed within the vertebral body and subsequently filled with TEKNIMED OPACITY+ Radiopaque Bone Cement (Model: T040320Z) to stabilize the vertebral compression fracture.
Device: CMT Vessel-X® Bone Filling Container System
Subjects undergo percutaneous vertebroplasty using the CMT Manual Orthopedic Surgical Instruments (Model: T-C308). Under real-time fluoroscopic guidance, a unilateral transpedicular approach is used to access the fractured vertebral body, and TEKNIMED OPACITY+ Radiopaque Bone Cement (Model: T040320Z) is directly injected into the vertebral body to stabilize the vertebral compression fracture.
Device: CMT Manual Orthopedic Surgical Instruments
Model: BVFT-UP01-D20 (TFDA No. 005889, GMP0106), manufactured by Central Medical Technologies Inc. (marketed since Aug 2017). An EO-sterilized, single-use, implantable kit for percutaneous vertebral augmentation (store \<= 25°C, shelf-life: 5 years). The kit includes: 1. Vessel-X® Bone Filling Container (Model: BVFX-D20): An implantable, microporous PET container to enclose cement and minimize leakage. 2. Front-Opening Cement Injection Device with Extension Tube (Model: T-C308, max 20 ml): For controlled hydraulic delivery. 3. Percutaneous Access Tools: Includes 1pc Bone Access Needle (T-N201T), 1pc Guide Pin (T-P602), and 1pc Precision Drill (T-D401). * Intervention Cement: TEKNIMED OPACITY+ Radiopaque Bone Cement (Model: T040320Z; TFDA License No. 026888), used during vertebral augmentation procedures for injection into the affected vertebra to stabilize vertebral compression fractures.
The CMT Manual Orthopedic Surgical Instruments (Model: T-C308; TFDA License No. 005698) are nonimplantable manual surgical instruments intended for conventional vertebroplasty procedures. The device functions as a manual cement delivery system for the injection of TEKNIMED OPACITY+ Radiopaque Bone Cement (Model: T040320Z; TFDA License No. 026888) into the vertebral body to stabilize vertebral compression fractures.
Incidence of Adverse Events, Serious Adverse Events (SAEs), and Unanticipated Serious Adverse Device Effects (USADEs)
The primary safety endpoint is to evaluate the safety profile of the "Central Medical" Vessel-X® Bone Filling Container System. Safety assessments will analyze the incidence, specific manifestations, severity, and device-causality of all adverse events (AEs), serious adverse events (SAEs), and unanticipated serious adverse device effects (USADEs) following percutaneous vertebroplasty (including bone cement leakage, nerve root injury, vascular injury, or subsequent vertebral collapse). Proportions of abnormal post-operative cases and complication incidence with 95% Confidence Intervals (CI) will be calculated using the Intent-to-Treat (ITT) population.
Time frame: Day 1 (post-op), Day 8 (8±2 days), Month 1 (31±2 days), Month 3 (91±15 days), Month 6 (181±15 days), Month 9 (271±15 days), and Month 12 (361±15 days) post-operatively.
Change From Baseline in Visual Analogue Scale (VAS) Pain Score
Pain intensity will be assessed using the 100-mm Visual Analogue Scale (VAS), where 0 indicates no pain and 100 indicates the worst imaginable pain. Changes from baseline in VAS scores will be compared between the experimental and control groups to evaluate pain relief following treatment.
Time frame: Baseline (within 1 week pre-operatively), Day 1 (post-operatively), Day 8 (8±2 days), Month 1 (31±2 days), Month 3 (91±15 days), Month 6 (181±15 days), Month 9 (271±15 days), and Month 12 (361±15 days) post-operatively.
Change From Baseline in Oswestry Disability Index (ODI) Score
Functional disability will be evaluated using the Oswestry Disability Index (ODI) questionnaire. Changes from baseline in ODI scores will be compared between the experimental and control groups to assess functional recovery following treatment.
Time frame: Baseline (within 1 week pre-operatively), Day 1 (post-operatively), Day 8 (8±2 days), Month 1 (31±2 days), Month 3 (91±15 days), Month 6 (181±15 days), Month 9 (271±15 days), and Month 12 (361±15 days) post-operatively.
Change From Baseline in Radiographic Anterior Vertebral Height
Radiographic assessment of anterior vertebral height (measured in millimeters) will be performed using X-ray, computed tomography (CT), or magnetic resonance imaging (MRI). Changes from baseline will be compared between the experimental and control groups to evaluate vertebral body restoration.
Time frame: Baseline (within 1 week pre-operatively), Day 1 (post-operatively), Day 8 (8±2 days), Month 1 (31±2 days), Month 3 (91±15 days), Month 6 (181±15 days), Month 9 (271±15 days), and Month 12 (361±15 days) post-operatively.
hange From Baseline in Radiographic Mid-Vertebral Height
Radiographic assessment of mid-vertebral height (measured in millimeters) will be performed using X-ray, computed tomography (CT), or magnetic resonance imaging (MRI). Changes from baseline will be compared between the experimental and control groups to evaluate vertebral body restoration.
Time frame: Baseline (within 1 week pre-operatively), Day 1 (post-operatively), Day 8 (8±2 days), Month 1 (31±2 days), Month 3 (91±15 days), Month 6 (181±15 days), Month 9 (271±15 days), and Month 12 (361±15 days) post-operatively.
Change From Baseline in Kyphotic Cobb's Angle
Radiographic assessment of the kyphotic Cobb's angle (measured in degrees) will be performed using sagittal X-ray, computed tomography (CT), or magnetic resonance imaging (MRI) to evaluate spinal alignment correction. Changes from baseline will be compared between the experimental and control groups.
Time frame: Baseline (within 1 week pre-operatively), Day 1 (post-operatively), Day 8 (8±2 days), Month 1 (31±2 days), Month 3 (91±15 days), Month 6 (181±15 days), Month 9 (271±15 days), and Month 12 (361±15 days) post-operatively.
Plan to share: No — IPD will not be shared to protect participant privacy and comply with institutional review board (IRB) restrictions and local data protection regulations.
Started Apr 2021 (actual). Primary completion is estimated for Dec 2026, 68 months after the start.
Of 220 non-industry interventional studies with no phase under Osteoporosis, half reached primary completion within 22 months of starting (the median), counting those still running; a quarter within 8 and three quarters within 49. This study's planned 68 months is above that.
Counting every sponsor, half of 239 studies reached it within 26 months; a quarter within 9 and three quarters within 50.
How these figures are worked out, and which studies are left out of them.
Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.
Contact study teamGet an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Juin-Hong Cherng