Automated Applanation Tonometry - Updated

An interventional study of Standard GAT and Fixed force GAT in Glaucoma and Glaucoma, Suspect, sponsored by Duke University. Recruiting at 1 site in United States. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2026-11-03.

Sponsored by Duke University · Not applicable, Interventional, and Diagnostic

How we know

From the registry’s dates

  • Started Mar 2026; still recruiting 8 months later.

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Phase
Not applicable
Study type
Interventional
Enrollment
200
Allocation
Randomized
Ages
18 Years and older
Sex
All
01

Where this study stands

Counted across the records on this site · 2026-11-22

Among 15 studies in Glaucoma by Duke University — 5 open to participants now, 5 under way, none of them phase 3. Glaucoma · Duke University.

Planned enrollment
3rd of 13
200 · median 76
Started
2026
with 2 others
No phase
12 of 15
4 open now
Registered
14th of 15
by date

Among the 15 studies in Glaucoma by Duke University, this one is the 3rd largest by planned enrollment of the 13 interventional ones that give a count, is one of 3 that started in 2026, is one of 12 with no phase, and was the 14th registered.

Glaucoma

1,421 studies on the registry are indexed under Glaucoma; 221 are open to participants now.

Browse Glaucoma studies →

Open to participants now

5 of the 15 studies in Glaucoma by Duke University are open now, in 1 country. Recruiting first, the newest first:

By country, each count listing its studies:

All 5 open studies →

Where they have run

Who these studies take

Of the 154 Glaucoma studies recruiting now, 112 (73%) set no upper age limit and 9 (6%) stop at 75 or younger; 13 take children under 18; 44 take healthy volunteers.

This study: 18 Years and older · all sexes · no healthy volunteers.

The full table on the hub →

This tab as a report to print or save as PDF → With an account.

Was this useful?
Get alerts for this landscapeDownload CSVNarrow it in search →With an account: a weekly mail of what changed among 15 studies in Glaucoma by Duke University, or all of them as a file.
02

Study summary

Goldmann Applanation Tonometry (GAT) is considered the clinical gold standard for eye pressure measurements and yet it is known to be a subjective measurement with limited repeatability and limited portability. Another clinical standard for checking eye pressure is known as the pneumotonometer. This method is more objective but not portable. The purpose of this study is to develop new methods of measuring eye pressure that are more objective, reproducible and portable. In this study, the investigators will be comparing the eye pressure measurements using 2 investigational methods to GAT and pneuumotonometer.

Read the detailed description

This is a prospective study. Patients presenting for their scheduled eye appointments will be recruited by verbal communication. Following informed consent, intraocular pressure (IOP) measurements will be made by the following methods:

Standard Goldmann Applanation Tonometry (GAT): this is the standard method for IOP measurement in clinical practice. The eye is given topical fluorescein/anesthetic, the GAT prism contacts the eye while the observer looks through the slit lamp machine ocular using blue light illumination to visual the applanation mires. The GAT dial is adjusted until mire alignment is achieved and the IOP measurement is read off the GAT dial.

Pneumotonometer: This is what is done in routine eye care. The participant will receive a topical anesthetic (numbing agent). A probe will touch the front of the eye while the machine measures the eye pressure.

Fixed force GAT: From the patient perspective, this method will feel identical to the standard GAT. The eye is given topical fluorescein/anesthetic. The GAT dial is set at 1.8 or 2.0, a complementary metal oxide semiconductor (C-MOS) camera is connected to one of the oculars of the slit lamp machine and under blue light illumination, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance through the ocular. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter. A similar method using an iPod touch camera has been previously published by this PI.

Upright applanating prototype: With this prototype, an applanating prism (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is attached to a fixed-force spring that creates a force equivalent to 1.8 or 2.0 on the GAT dial. Blue LED lights on the prototype are used to create the blue illumination similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. A C-MOS camera is aligned with the GAT prism to image the applanation mires. The eye is given topical fluorescein/anesthetic. Like fixed-force GAT, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter.

The order of the above 4 measurements will be randomized.

03

Conditions studied

  • Glaucoma
  • Glaucoma, Suspect
04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Criteria:

Inclusion criteria

Inclusion Criteria:

  • Presenting for a routine eye exam
  • ≥ 18 years of age
  • Able and willing to give consent

Exclusion criteria

Exclusion Criteria:

  • History of corneal scarring
  • Active infection of the eye
  • Ocular surface trauma or infection
05

Study design

Phase
Not applicable
Primary purpose
Diagnostic
Allocation
Randomized
Intervention model
Parallel assignment
Masking
None (open label)
Enrollment
200 participants (estimated)

Study arms

  • Active comparator
    Standard GAT

    This is the gold-standard method for IOP measurement in clinical practice

    Device: Standard GAT

  • Experimental
    Fixed-force GAT

    From the patient perspective, this method will feel identical to the standard GAT. The eye is given topical fluorescein/anesthetic. The GAT dial is set at 1.8 or 2.0, a C-MOS camera is connected to one of the oculars of the slit lamp machine and under blue light illumination, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance through the ocular. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter

    Device: Fixed force GAT

  • Experimental
    Upright applanating prototype

    With this prototype, an applanating prism (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is attached to a fixed-force spring that creates a force equivalent to 1.8 or 2.0 on the GAT dial. Blue LED lights on the prototype are used to create the blue illumination similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. A C-MOS camera is aligned with the GAT prism to image the applanation mires. The eye is given topical fluorescein/anesthetic. Like fixed-force GAT, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter

    Device: Upright applanating prototype

  • Active comparator
    Pneumotonometer

    This is another standard method for IOP measurement in clinical practice

    Device: Pneumotonometer

Interventions

  • DeviceStandard GAT

    Standard Goldmann Applanation Tonometry (GAT): this is the standard method for IOP measurement in clinical practice

  • DeviceFixed force GAT

    An investigational device similar to standard GAT

  • DeviceUpright applanating prototype

    An investigational device, prism used in standard and fixed-force GAT is attached to a portable device

  • DevicePneumotonometer

    This is a standard for checking eye pressure. A topical anesthetic (numbing agent). A probe will touch the front of the eye while the machine measures the eye pressure

06

What researchers measure

Primary outcomes

  1. Intraocular pressure (IOP) as measured by standard GAT

    this is the standard method for IOP measurement in clinical practice. The eye is given topical fluorescein/anesthetic, the GAT prism contacts the eye while the observer looks through the slit lamp machine ocular using blue light illumination to visual the applanation mires. The GAT dial is adjusted until mire alignment is achieved and the IOP measurement is read off the GAT dial.

    Time frame: Baseline

  2. Intraocular pressure (IOP) as measured by fixed force GAT

    From the patient perspective, this method will feel identical to the standard GAT. The eye is given topical fluorescein/anesthetic. The GAT dial is set at 1.8 or 2.0, a C-MOS camera is connected to one of the oculars of the slit lamp machine and under blue light illumination, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance through the ocular.

    Time frame: Baseline

  3. Intraocular pressure as measured by upright applanating

    With this prototype, an applanating prism (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is attached to a fixed-force spring that creates a force equivalent to 1.8 or 2.0 on the GAT dial. Blue LED lights on the prototype are used to create the blue illumination similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. A C-MOS camera is aligned with the GAT prism to image the applanation mires. The eye is given topical fluorescein/anesthetic. Like fixed-force GAT, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter.

    Time frame: Baseline

  4. Intraocular pressure as measured by supine Pneumotonometer

    Time frame: Baseline

07

Study locations

1 of 1 sites recruiting
08

References and documents

Individual participant data

Plan to share: No — No Currently, there is no plan to share data with other researchers.

No publications or documents are linked to this record.

09

Timeline

1 registry update since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Started Mar 2026 (actual). Primary completion is estimated for Dec 2026, 9 months after the start.

Of 230 non-industry interventional studies with no phase under Glaucoma, half reached primary completion within 32 months of starting (the median), counting those still running; a quarter within 12 and three quarters within 55. This study's planned 9 months is below that.

Counting every sponsor, half of 288 studies reached it within 30 months; a quarter within 12 and three quarters within 53.

How these figures are worked out, and which studies are left out of them.

Registered
Dec 19, 2025
First posted
Dec 23, 2025
StartActual
Mar 2, 2026
Primary completionEst.
Dec 29, 2026
CompletionEst.
Dec 29, 2026
Last update
Nov 3, 2026
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
Site contacts
Changed at 1 site. See the sites
Show the site
  • Duke Eye Center · Durham, United StatesContact •••2975→•••2975
Nov 3, 2026
Show all 1 update
  1. Nov 3, 2026
    Site contacts Changed at 1 site. See the sites
    Show the site
    • Duke Eye Center · Durham, United StatesContact •••2975→•••2975
    + 1 other change: verification date

From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗

10

Registry details

Key details

Study ID
NCT07298356
Lead sponsor
Duke University
Responsible party
Sponsor
First posted
Dec 23, 2025
Start date
Mar 2, 2026
Primary completion
Dec 29, 2026 (estimated)
Completion
Dec 29, 2026 (estimated)
Last update
Nov 3, 2026

Study contacts

Sarah Jones
Contact
sarah.jones1@duke.edu
919 681 6584
Joanne Wen, MD
principal investigator · Duke Eye Center

Oversight

Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

Contact study team

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion