Advanced OCT and Adaptive Optics Imaging in Retinal Disease (The ACAD Study)

An observational study in Vitreous Diseases, Retinal Diseases and Choroidal Diseases, sponsored by Moorfields Eye Hospital NHS Foundation Trust. Completed at 1 site in United Kingdom. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2020-09-09.

Sponsored by Moorfields Eye Hospital NHS Foundation Trust · Observational

Study type
Observational
Model
Cohort
Time perspective
Prospective
Enrollment
300
Ages
18 Years and older
Sex
All
01

Study summary

The objectives of this study include using the new technology of SS-OCT (swept source optical coherence tomography) to evaluate morphological abnormalities of the vitreous, retina and choroid and to assess the repeatability of retinal and choroidal thickness measurements in retinal disease using SS-OCT. A secondary objective is to use the new imaging modality of adaptive optics to directly visualize photoreceptor mosaics and microvasculature in eyes with retinal and choroidal disease.

Read the detailed description

Diseases affecting the vitreous, retina and choroid are among the commonest causes of sight-loss and vision impairment in England and Wales.

These diseases may display a wide range of pathological features including vitreous, retinal and subretinal haemorrhage; macular fluid; choroidal inflammation and choroidal masses.

The retina is a 'window to the brain' and there is increasing evidence that neurodegenerative disorders such as Multiple Sclerosis, Parkinsons Disease and Alzheimers Disease have retinal manifestations which may have prognostic implications, afford earlier diagnosis, and potentially act as surrogate endpoints for treatment trials.

In 2012, a further advance in OCT technology was brought to market with the arrival of the first commercial available swept-source OCT (SS-OCT) device (the Topcon DRI OCT). SS-OCT technology uses a tuneable laser light source with a longer wavelength of light (typically 1040-1050 nm central wavelength) than the light sources seen in more conventional SD-OCT devices. This leads to greater tissue penetration with less backscatter from the RPE, producing images of the choroid with greater resolution with fast image acquisition speeds (100,000 A scans/s) and longer line scan lengths. The ability to take rapid scans with the only commercially available SS-OCT device (the DRI, Tocon Inc. Paramus, NY, USA) also enhances image quality by line scan averaging capability.

The high axial resolution of OCT allows discrimination of the distinct retinal layers that are affected differentially in different diseases. More direct visualisation of the photoreceptor layer is afforded by use of an Adaptive Optics Scanning Light Ophthalmoscope (AOSLO), which provides excellent lateral resolution and allows direct visualisation of the cone and rod photoreceptor mosaics in vivo by correcting for ocular aberrations and resulting in a lateral comparable with histopathological sections.

In this study AO images will be correlated with SD- and SS-OCT and used to comprehensively assess the integrity of the photoreceptor mosaic. Furthermore AO and OCT will be used to measure nerve fibre layer loss and optic disc changes if relevant to the disease.

The imaging modalities used in this study will be spectral domain optical coherence topography (SD-OCT), swept source optical coherence tomography (SS-OCT), and adaptive optics scanning light ophthalmoscope (AOSLO)

The study will examine 300 patients (up to 600 eyes) in a single visit with a further Adaptive Optics (AO) imaging taken in a subset of patients (up to 200).

Patients in whom AO imaging was possible from a technical perspective will be invited back for further imaging after 6-12 months (at a standard NHS follow up visit) to probe longitudinal changes.

An examiner will scan the participants study eye(s) on the same day on each of the 3 imaging modalities SD-OCT, SS-OCT and AOSLO.

Finally a questionnaire will be used to explore whether participants preferred one OCT imaging modality over the other (SS-OCT vs SD-OCT).

02

Conditions studied

  • Vitreous Diseases
  • Retinal Diseases
  • Choroidal Diseases
03

In context

Retinal Diseases

815 studies on the registry are indexed under Retinal Diseases; 105 are open to participants now.

This study's enrollment of 300 is above the median of 180 across 282 observational studies indexed under Retinal Diseases.

Browse Retinal Diseases studies →

Lead sponsor

Moorfields Eye Hospital NHS Foundation Trust is the lead sponsor of 48 studies on the registry; 4 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No
Sampling method
Non-probability sample

Study population

Patients attending Moorfields Eye Hospital with a diagnosis of diseases of the vitreous, retina or choroid in at least one eye

Inclusion criteria

  1. Patients attending Moorfields Eye Hospital with a diagnosis of diseases of the vitreous, retina or choroid in at least one eye including but not restricted to:

    1. Vitritis
    2. Vitreomacular interface abnormalities including macular hole
    3. Age-related macular degeneration
    4. Diabetic macular oedema and retinopathy
    5. Other causes of macular oedema
    6. Inherited retinal dystrophies
    7. Inherited macular dystrophies
    8. Posterior Uveitis (infectious and non-infectious)
    9. Retinal nerve fibre layer loss (eg due to glaucoma)
  2. Patients with neurodegenerative diseases such as multiple sclerosis for which there is previous literature identifying retinal/choroidal abnormalities referred by Consultant Neurologists within UCL Partners
  3. Male or female aged 18 years old or over.
  4. Ability to understand nature/purpose of study and to provide informed consent
  5. Ability to undergoing imaging
  6. Ability to follow instructions and complete study

Exclusion criteria

Exclusion Criteria:

  1. History of previous significant ocular trauma
  2. Any condition which, in the investigator's opinion, would conflict or otherwise prevent the subject from complying with the required procedures, schedule or other study conduct.
05

Study design

Observational model
Cohort
Time perspective
Prospective
Enrollment
300 participants (actual)
Patient registry
No

Interventions

  • DeviceSwept-source optical coherence tomography (SS-OCT)

    The SD-OCT provides faster images and the ability to scan more of the central retina (macula). SD-OCT simultaneously measures multiple wavelengths of reflected light across a spectrum generating up to 40,000 A-Scans (axially sample points) per second. This allows the generation of 3 dimensional faster based volumetric images of the retina. The Spectralis OCT utilises real-time hardware eye tracking to resample lines scan enhancing the signal to noise ratio by improving the image quality. The swept-source OCT (SS-OCT) uses a tuneable laser light source with a longer wavelength of light (typically 1040-1050 nm) that the light source seen in more conventional SD-OCT devices. The tissue penetration and resolution is greater with fast acquisition speeds and longer line scan lengths.

    Also known as: Spectral Domain coherence topography (SD-OCT), Adaptive Optics Scanning light ophthalmoscope (AOSLO)

06

What researchers measure

Primary outcomes

  1. 3 repeated measurements of choroid + retinal thickness using SD-OCT and SS-OCT and optic nerve head imaging

    Time frame: 3 years

Secondary outcomes

  1. Percentage concordance and Kappa statistics of detection of morphological abnormalities in widefield OCT and conventional filed OCT (Spectralis OCT)

    Time frame: 3 years

  2. Repeated measures of photoreceptor mosaic integrity and microsvasculature (subset of patients only) at 2 visits

    Time frame: 3 years

07

Study locations

1 site
  • NIHR Clinical Research Facility - Moorfileds Eye Hospital
    London, EC1V 2PD, United Kingdom
08

References and documents

Publications

  • Hanumunthadu D, Keane PA, Balaskas K, Dubis AM, Kalitzeos A, Michaelides M, Patel PJ. Agreement Between Spectral-Domain and Swept-Source Optical Coherence Tomography Retinal Thickness Measurements in Macular and Retinal Disease. Ophthalmol Ther. 2021 Dec;10(4):913-922. doi: 10.1007/s40123-021-00377-8. Epub 2021 Jul 29. PubMed 34324166 ↗

Individual participant data

Plan to share: No

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Sep 9, 2020, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT02828215
Lead sponsor
Moorfields Eye Hospital NHS Foundation Trust
Responsible party
Sponsor
First posted
Jul 11, 2016
Start date
Jul 1, 2015
Primary completion
Dec 1, 2019
Completion
Jun 6, 2020
Last update
Sep 9, 2020

Study contacts

Praveen Patel, MBBChir MA FRCOphth MD(Res)
principal investigator · Moorfields Eye Hospital NHS Foundation Trust

Oversight

Data monitoring committee
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Sep 2020. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion