ClinicalTrials.gg
CompletedNCT07182786Updated Sep 19, 2025

The Efficacy of Laryngeal Mask Airway Gastro (LMA® Gastro™) in Preventing Hypercarbia in ERCP Patients

An interventional study of LMA Gastro in Endoscopy, Gastrointestinal, Procedural Sedation and Anesthesia Airway Management, sponsored by Cairo University. Completed at 1 site in Egypt. Open to participants aged 20 Years to 45 Years. Per ClinicalTrials.gov, last updated 2025-09-19.

Sponsored by Cairo University · Not applicable, Interventional, and Supportive care

From the registry’s dates

  • Primary completion was Jul 2025, 1 year 3 months ago, and no results have been posted to the registry.
  • Registered 11 months after the study started (first participant enrolled Oct 2024, registered Sep 2025).
Phase
Not applicable
Study type
Interventional
Enrollment
50
Allocation
Randomized
Ages
20 Years to 45 Years
Sex
All
01

Study summary

Endoscopic retrograde cholangiopancreatography (ERCP) has evolved into a primarily therapeutic procedure that often requires anesthetic support. While moderate to deep sedation is commonly used, it carries a high risk of respiratory complications, including hypoxemia and hypercapnia, which can lead to cardiovascular instability. General anesthesia with endotracheal intubation offers greater airway protection but is associated with hemodynamic stress, the need for neuromuscular blockade, longer recovery, and potential airway trauma.

The LMA® Gastro™ Airway, introduced in 2017, was specifically designed for upper gastrointestinal endoscopy. It combines a supraglottic airway with a dedicated channel for the endoscope, enabling ventilation and airway protection while facilitating the procedure. Early studies demonstrate high success rates for both airway management and ERCP completion, with a low incidence of adverse events. However, most available evidence is observational, and randomized controlled trials are needed to establish its effectiveness compared with traditional sedation and general anesthesia with intubation.

In conclusion, the LMA Gastro shows promise as a safe and efficient alternative airway device for ERCP, potentially bridging the gap between deep sedation and invasive intubation, though further evidence is required to confirm its impact on respiratory and hemodynamic outcomes.

Read the detailed description

Endoscopic retrograde cholangiopancreatography (ERCP) is fast emerging as a therapeutic procedure rather than a diagnostic one, requiring anesthetic support for successful completion of the procedure. The procedure can be uncomfortable especially due to prone positioning, multiple passages of endoscope, air insufflations, dilatation of ductal structures and prolonged duration which requires a high degree of cooperation from patients. A large number of patients need to be given general anesthesia (GA), in order to minimize incidence of adverse respiratory and hemodynamic events in the peri-procedure period. The use of GA with endotracheal intubation (ETT) or supraglottic devices protects the airway, reduces ERCP failure and complication rates. However, ETT involves rigid laryngoscopy with consequent undesirable hemodynamic responses and use of neuromuscular blocking drugs. It also has the disadvantage of a longer recovery time and possibility of injury to the oro-pharynx at insertion.

Moderate to deep sedation is a commonly employed technique for ERCPs, with general anesthesia utilizing an endotracheal intubation being reserved for selected cases. Reported rates of hypoxemia during all endoscopic procedures range from 11 to 50%, and this may be as high as 60% with ERCP. Sustained hypoxia is a major risk factor for peri-procedural cardiac arrhythmias and myocardial ischemia. Respiratory complications that occur during intravenous sedation have a higher risk of hypercapnia than hypoxemia. Patients receiving propofol-based tubeless sedation may be at higher risk of sedation-related adverse events than patients receiving GA. Moreover, when low-flow oxygen is administered through a nasal cannula, the apparent oxygen saturation value is maintained at a normal concentration; however, hypoventilation is sustained, which may result in impaired exhalation. Gradual CO₂ accumulation, and CO₂ concentrations maintained at 60 mmHg or higher, are risk factors for secondary circulatory abnormalities such as an abnormal increase in blood pressure, tachycardia, and arrhythmia.

As the number of gastrointestinal endoscopic interventions and possibilities increased, and the number of patients with severe comorbidities and existing medical conditions, the need for minimally invasive airway devices specially dedicated for endoscopic procedures became relevant. A modified laryngeal tube with a dedicated channel for an endoscope was described as an alternative airway device. This approach was further developed with the introduction of the LMA® Gastro™ Airway, a refined tool in advanced airway management for upper gastrointestinal endoscopy.

The LMA® Gastro™ Airway is a cuffed peri-laryngeal supraglottic airway (SGA) with an endoscopic channel, having a maximum diameter of 14 mm, which suits all standard endoscopes. Its design features include a channel for esophageal intubation, a separate channel with a terminal cuff for lung ventilation, and an integrated bite block and cuff pressure indicator. It comes in three available sizes: #3 (30-50 kg), #4 (50-70 kg), and #5 (70-100 kg).

This device has been reported to have a high airway insertion success rate and a high first-attempt endoscopy success rate in patients with low risk of pulmonary aspiration. Observational studies have suggested that the LMA Gastro may be a safe alternative to tubeless anesthesia in patients undergoing ERCP, though some were limited by small sample size and non-randomized design. Retrospective analyses have demonstrated high success rates of ERCP completion with well-maintained ventilation and minimal intraoperative and postoperative adverse events. However, confounding factors in patient selection and the absence of randomized controlled comparisons with conventional airway techniques remain limitations.

Although the LMA Gastro has been demonstrated in several studies as a safe and efficient substitute for general anesthesia or deep sedation tubeless anesthesia for ERCP procedures, to date there is no exact measurement or assessment of its role in prevention of hypercarbia or hypoxia.

Aim of the work:

The aim of this study is to evaluate the efficacy of using LMA Gastro in preventing hypercarbia and decreasing hypoxic and hyper carbic episodes in patients undergoing ERCP procedures of average timing and difficulty according to the ASGE (American Society of Gastroenterologists) grading system. In addition, to assess the efficiency of using the new LMA Gastro® airway device in endoscopic procedures and its stress response.

02

Conditions studied

  • Endoscopy, Gastrointestinal
  • Procedural Sedation
  • Anesthesia Airway Management
  • Anesthesia for Endoscopic Procedures

Browse trials for

Keywords

  • ERCP anesthesia
  • Anesthesia for endoscopy
  • LMA Gastro
  • Hypercarbia
03

In context

Hypercapnia

156 studies on the registry are indexed under Hypercapnia; 31 are open to participants now.

This study's enrollment of 50 is above the median of 36 across 120 interventional studies indexed under Hypercapnia.

Browse Hypercapnia studies →

Lead sponsor

Cairo University is the lead sponsor of 4,941 studies on the registry; 1,458 are open to participants now.

Of its 37 completed or terminated interventional studies of FDA-regulated products, 5 (14%) have results posted.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
20 Years to 45 Years
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Adult patients age: 20-45 years
  • : II and III
  • : 25 -30 kg/m2
  • Height > 155 cm
  • ERCP procedures of difficulty grade II and III (according to American Society of Gastroenterologists ASGE grading system for ERCP procedures).

Exclusion criteria

Exclusion Criteria:

  • Anticipated difficult airway
  • Restricted head and neck mobility
  • Pulmonary disease
  • Obese Patients with a of ≥ 35 kg/m2
  • Patients with moderate to severe ascites
  • Patients with Childe-Pughe-Turcotte (CPT) classification C
  • Increased risk of aspiration (for example incomplete fasting hours, delayed gastric emptying, gastric outlet obstruction, etc.)
  • ERCP procedures of difficulty grade I (due to relatively short procedure duration)
  • ERCP procedures of malignant obstructive jaundice
  • ERCP procedures less than 30 minutes and more than 120 minutes.
  • Patient refusal
Terms in these criteria, in plain language(2)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

ASA physical status

The anaesthetists’ scale of health before surgery: I is healthy, II has a mild illness that is under control, III a severe one, IV a severe illness that is a constant threat to life. V and VI are used for the critically ill and for organ donors.

BMI (body mass index)

Weight in kilograms divided by height in metres squared. Example: 70 kg and 1.75 m gives 70 ÷ (1.75 × 1.75) ≈ 22.9.

What counts as overweight or obesity differs between countries (some use lower cut-offs), so go by the range the study states.

05

Study design

Phase
Not applicable
Primary purpose
Supportive care
Allocation
Randomized
Intervention model
Parallel assignment
Masking
None (open label)
Enrollment
50 participants (actual)

Study arms

  • Active comparator
    LMA Gastro group (L group): total intravenous anesthesia and LMA Gastro

    Device: LMA Gastro

  • No intervention
    Control group (C group): total intravenous anesthesia with no airway device , with Nasal Cannula.

Interventions

  • DeviceLMA Gastro

    LMA Gastro, is a laryngeal mask airway device that is specifically designed for air way management in GIT endoscopic procedures due to having a channel dedicated for endoscope introduction. the safety and efficacy of LMA Gastro was researched in many studies, but its role in preventing Hypercarbia during ERCP procedures is yet to be researched and tested.

06

What researchers measure

Primary outcomes

  1. End tidal CO2

    End tidal CO2 measurement after 30 minutes of procedure time. It is measured by capnography in patients undergoing ERCP procedure.

    Time frame: 30 minutes from induction of Anesthesia

Secondary outcomes

  1. Hypercarbia

    ETCO2 (≥45 mmHg) or PaCO2(≥50 mmHg) or both Highest ETCO2 and PaCO2 recorded during procedure

    Time frame: Procedures of duration between 30 and 120 minutes

  2. Timing of Hypercarbia

    Time till ETCO2 (≥45 mmHg) or PaCO2(≥50 mmHg) or both

    Time frame: Procedures of duration between 30 and 120 minutes

  3. Hypoxia

    Lowest SpO2 and PaO2 recorded during procedure

    Time frame: Procedures of duration between 30 and 120 minutes.

  4. Number of Hypoxic episodes

    Number of hypoxic episodes (desaturation to SPO2 of 92% or below for at least 15 seconds)

    Time frame: Procedures of duration between 30 and 120 minutes

  5. Hemodynamic stress response : Heart Rate

    Heart rate

    Time frame: Procedures of duration between 30 and 120 minutes.

  6. Hemodynamic stress response : Mean arterial blood pressure

    Mean arterial blood pressure

    Time frame: Procedures of duration between 30 and 120 minutes.

  7. Efficiency of LMA gastro in anesthesia of ERCP procedures: duration till endoscope introduction.

    Measuring time taken from induction of anesthesia till ERCP duodenoscope introduction( start of ERCP procedure).

    Time frame: From Anesthesia induction till start of procedure

  8. Efficiency of LMA gastro in anesthesia of ERCP procedures: Ease of duodenoscope introduction.

    Number of attempts of ERCP duodenoscope introduction

    Time frame: From induction of Anesthesia till start of procedure

  9. Efficiency of LMA gastro in anesthesia of ERCP procedures: ease of LMA Gastro insertion.

    Number of attempts of LMA Gastro insertion

    Time frame: From induction of Anesthesia till start of procedure

  10. Efficiency of LMA gastro in anesthesia of ERCP procedures: Safety of LMA Gastro

    Number of displacements of LMA Gastro and need for repositioning

    Time frame: During whole ERCP procedure

  11. Efficiency of LMA gastro in anesthesia of ERCP procedures: Anesthetic consumption of propofol

    * Mean dose of propofol used in induction in both groups * Mean dose of propofol used for maintenance of anesthesia

    Time frame: whole duration of ERCP procedure

  12. Efficiency of LMA gastro in anesthesia of ERCP procedures: Recovery time

    Recovery time (from stopping propofol infusion till discharge to PACU)

    Time frame: from the end of ERCP procedure till discharge to PACU

  13. Efficiency of LMA gastro in anesthesia of ERCP procedures: procedure failure

    Number of failed procedures in both groups

    Time frame: procedures between 30 and 120 minutes

  14. Efficiency of LMA gastro in anesthesia of ERCP procedures: procedure duration

    Effect of using LMA Gastro on average procedure duration in comparison to control group

    Time frame: procedures between 30 and 120 minutes

  15. Efficiency of LMA gastro in anesthesia of ERCP procedures: post operative complications

    occurrence of post operative Nausea, vomiting or sore throat

    Time frame: From end of procedure till discharge from PACU (after 30 min.)

  16. Efficiency of LMA gastro in anesthesia of ERCP procedures: operator satisfaction

    The operator rates the following on a scale from 1to 5 ( 1 being worst and 5 the best): * ease of endoscope introduction * ease of manipulation and advancement * overall satisfaction

    Time frame: procedures between 30 and 120 minutes

  17. Efficiency of LMA gastro in anesthesia of ERCP procedures: anesthesiologist satisfaction

    The anesthesiologist rates the following on a scale from 1 to 5 ( 1 being the worst and 5 the best): * ease of LMA Gastro insertion * overall satisfaction

    Time frame: procedures between 30 and 120 minutes

  18. Efficiency of LMA gastro in anesthesia of ERCP procedures: conversion to endotracheal intubation.

    number of procedures that were converted to traditional endotracheal intubation due to vomiting, risk of aspiration with excessive secretions in oral cavity, severe laryngeal spasm not responding to increasing depth of anesthesia or I.V. lidocaine, airway obstruction and persistent hypoxia.

    Time frame: procedures between 30 and 120 minutes

07

Study locations

1 site
  • Theodor Bilharz Research Institute
    Giza, 12411, Egypt
08

References and documents

Individual participant data

Plan to share: Undecided

No publications or documents are linked to this record.

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Sep 19, 2025, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT07182786
Lead sponsor
Cairo University
Collaborators
Theodor Bilharz Research Institute
Responsible party
Karim Mohamed Aly Ahmed (Assistant Lecturer of Anesthesiology, Surgical ICU & Pain Management,Theodor Bilharz Research Institute. Candidate for MD degree , Anaesthesia department , Cairo University., Theodor Bilharz Research Institute) — Principal investigator
First posted
Sep 19, 2025
Start date
Oct 1, 2024
Primary completion
Jul 15, 2025
Completion
Jul 15, 2025
Last update
Sep 19, 2025

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Sep 2025. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion