ClinicalTrials.gg
CompletedNCT07076160Updated Oct 15, 2026Results posted

Pilot Dispensing Study of Two Marketed Daily Disposable Multifocal Contact Lenses

An interventional study of INFUSE® One Day Multifocal and ACUVUE® OASYS MAX 1-Day Multifocal Contact Lens in Visual Acuity and Presbyopia, sponsored by Johnson & Johnson Vision Care, Inc.. Completed at 7 sites in United States. Open to participants aged 40 Years to 70 Years, including healthy volunteers. Per ClinicalTrials.gov, last updated 2026-10-15.

Sponsored by Johnson & Johnson Vision Care, Inc. (part of Johnson & Johnson) · Not applicable, Interventional, and Treatment

Updated Oct 15, 2026Results postedStudy documents posted+1 moreGo to Updates ↓
Phase
Not applicable
Study type
Interventional
Enrollment
74
Allocation
Randomized
Ages
40 Years to 70 Years
Sex
All
01

Study summary

This is a 6-visit, single-masked, multi-site, 2×3 crossover, randomized-controlled, dispensing clinical trial to evaluate visual acuity.

02

Conditions studied

  • Visual Acuity
  • Presbyopia

Browse trials for

03

In context

Presbyopia

336 studies on the registry are indexed under Presbyopia; 35 are open to participants now.

This study's enrollment of 74 is above the median of 61 across 276 interventional studies indexed under Presbyopia.

Browse Presbyopia studies →

Lead sponsor

Johnson & Johnson Vision Care, Inc. is the lead sponsor of 221 studies on the registry; 1 is open to participants now.

Of its 111 completed or terminated interventional studies of FDA-regulated products, 103 (93%) have results posted.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
40 Years to 70 Years
Sexes eligible
All
Accepts healthy volunteers
Yes

Eligibility criteria

Potential subjects must satisfy all of the following criteria to be enrolled in the study:

  1. Read, understand, and sign the STATEMENT OF and receive a fully executed copy of the form.
  2. Appear able and willing to adhere to the instructions set forth in this clinical protocol.
  3. Be at least 40 years of age and not greater than 70 years of age at the time of consent.
  4. Own a wearable pair of spectacles if required for their distance vision.
  5. Be an adapted soft contact lens wearer in both eyes (i.e. worn lenses a minimum of 2 days per week for at least 6 hours per wear day, for 30 days or more duration).
  6. Either already be wearing a presbyopic contact lens correction (e.g., reading spectacles over contact lenses, monovision or multifocal contact lenses, etc.) or if not respond positively to at least one symptom on the "Presbyopic Symptoms Questionnaire".
  7. The subject's distance spherical equivalent refraction must be in the range of +1.00 to +4.00 or -1.00 D to -4.00 D in each eye.
  8. The subject's refractive cylinder must be ≤0.75 D in each eye.
  9. The subject's ADD power must be in the range of +0.75 D to +2.50 D.
  10. The subject must have distance best corrected visual acuity of 20/20-3 or better in each eye.

Potential subjects who meet any of the following criteria will be excluded from participating in the study:

  1. Be currently pregnant or lactating.
  2. Have any active or ongoing ocular or systemic allergies that may interfere with contact lens wear.
  3. Have been diagnosed with diabetes.
  4. Have any active or ongoing systemic disease, disease, or use of medication, which may interfere with contact lens wear. This includes, but not be limited to, hyperthyroidism, Sjögren's syndrome, xerophthalmia, acne rosacea, Stevens-Johnson syndrome, and diseases or any infectious diseases (e.g. hepatitis, tuberculosis).
  5. Have any previous, or planned, ocular or intraocular surgery (e.g. radial keratotomy, PRK, LASIK, lid procedures, dacryocystorhinostomy, peripheral iridotomy/iridectomy, cataract surgery, retinal surgery, etc.).
  6. Have a history of amblyopia, strabismus or binocular vision abnormality.
  7. Use of any of the following medications within 1 week prior to enrollment: oral retinoid, oral tetracyclines, anticholinergics, oral phenothiazines, oral/inhaled . See section 9.1 for further examples.
  8. Be currently using any ocular medications with the exception of rewetting drops.
  9. Have a history of herpetic keratitis.
  10. Have a history of irregular cornea.
  11. Have a history of pathological dry eye.
  12. Have participated in any contact lens or lens care product clinical trial within 7 days prior to study enrollment.
  13. Be an employee (e.g., Investigator, Coordinator, Technician) or immediate family member of an employee (including partner, child, parent, grandparent, grandchild, sibling of the employee or their spouse) of the clinical site.
  14. Have any known or allergic reaction to non-preserved rewetting drop solutions or sodium fluorescein.
  15. Have (grade 3 or higher on the FDA grading scale) slit lamp findings (e.g., corneal edema, neovascularization or staining, tarsal abnormalities or bulbar injection) or other corneal or ocular disease or abnormalities that contraindicate contact lens wear or may otherwise compromise study endpoints (including entropion, ectropion, chalazia, recurrent styes, glaucoma, history of recurrent corneal erosions, aphakia, moderate or above corneal distortion, herpetic keratitis).
  16. Have any current ocular infection or inflammation.
Terms in these criteria, in plain language(6)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

Autoimmune disease

A condition in which the immune system attacks the body’s own tissues, such as rheumatoid arthritis, lupus, psoriasis, type 1 diabetes or inflammatory bowel disease.

Immunotherapy studies often leave out active autoimmune disease, and some name exceptions, such as thyroid disease on replacement hormone. Check the exceptions this study lists.

Immunosuppression

A weakened immune system. It can come from an illness, such as HIV or some blood cancers, or from medicines that turn the immune system down, for example after an organ transplant or for an autoimmune disease; steroids at higher doses count.

Read whether the line is about a condition or about medicines, and which medicines and doses it means.

Corticosteroids (steroids)

Anti-inflammatory medicines such as prednisone, prednisolone and dexamethasone — not the anabolic steroids used for muscle.

Studies differ in what they allow: check which steroid medicines, routes (tablets, injections, creams, inhalers, eye drops) and doses this study accepts.

Hypersensitivity

An allergy, or another reaction of the immune system, to a substance. “Hypersensitivity to the study drug” means a known allergic reaction to it — not every side effect a medicine can have.

Clinically significant

Judged by the study doctor to matter for your health or for the study. It is a doctor’s decision, so ask the study team if you are unsure whether something counts.

05

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Randomized
Intervention model
Crossover assignment
Masking
Single (Participant)
Enrollment
74 participants (actual)

Study arms

  • Experimental
    Test/Control/Control

    Eligible subjects will be randomized into the Test/Control/Control sequence.

    Device: INFUSE® One Day Multifocal · Device: ACUVUE® OASYS MAX 1-Day Multifocal Contact Lens

  • Experimental
    Control/Test/Test

    Eligible subjects will be randomized into the Control/Test/Test sequence.

    Device: INFUSE® One Day Multifocal · Device: ACUVUE® OASYS MAX 1-Day Multifocal Contact Lens

Interventions

  • DeviceINFUSE® One Day Multifocal

    Test Lens

  • DeviceACUVUE® OASYS MAX 1-Day Multifocal Contact Lens

    Control Lens

06

What researchers measure

Primary outcomes

  1. High Luminance High Contrast (HLHC) Binocular logMAR Visual Acuity at Distance (4m)

    Binocular visual acuity was measured on a logMAR (Logarithm of Minimal Angle of Resolution) scale under high luminance high contrast condition. At distance (4 meters), VA is assessed using ETDRS (Early Treatment Diabetic Retinopathy Study) charts; while near (40 cm) and intermediate (64 cm) assessments were made using reduced Guillon-Poling charts. Letter-by-letter results calculated the visual performance score for each chart read. LogMAR scores closer to zero, or below zero, indicate a better visual acuity. A logMAR visual performance score of 0.0 is equivalent to Snellen visual acuity of 20/20.

    Time frame: 1-Week Follow-up

  2. High Luminance High Contrast (HLHC) Binocular logMAR Visual Acuity at Intermediate (64cm)

    Binocular visual acuity was measured on a logMAR (Logarithm of Minimal Angle of Resolution) scale under high luminance high contrast condition. At distance (4 meters), VA is assessed using ETDRS (Early Treatment Diabetic Retinopathy Study) charts; while near (40 cm) and intermediate (64 cm) assessments were made using reduced Guillon-Poling charts. Letter-by-letter results calculated the visual performance score for each chart read. LogMAR scores closer to zero, or below zero, indicate a better visual acuity. A logMAR visual performance score of 0.0 is equivalent to Snellen visual acuity of 20/20.

    Time frame: 1-Week Follow-up

  3. High Luminance High Contrast (HLHC) Binocular logMAR Visual Acuity at Near (40cm)

    Binocular visual acuity was measured on a logMAR (Logarithm of Minimal Angle of Resolution) scale under high luminance high contrast condition. At distance (4 meters), VA is assessed using ETDRS (Early Treatment Diabetic Retinopathy Study) charts; while near (40 cm) and intermediate (64 cm) assessments were made using reduced Guillon-Poling charts. Letter-by-letter results calculated the visual performance score for each chart read. LogMAR scores closer to zero, or below zero, indicate a better visual acuity. A logMAR visual performance score of 0.0 is equivalent to Snellen visual acuity of 20/20.

    Time frame: 1-Week Follow-up

07

Results

Posted Oct 15, 2026

Participant flow

Period 1
Participant flow — Period 1
MilestoneKalifilcon A/ Senofilcon A C3/ Senofilcon A C3Senofilcon A C3/ Kalifilcon A/ Kalifilcon A
Started3634
Completed3634
Not completed00
Period 2
Participant flow — Period 2
MilestoneKalifilcon A/ Senofilcon A C3/ Senofilcon A C3Senofilcon A C3/ Kalifilcon A/ Kalifilcon A
Started3634
Completed3633
Not completed01
Withdrew: Unsatisfactory lens fitting due to test article01
Period 3
Participant flow — Period 3
MilestoneKalifilcon A/ Senofilcon A C3/ Senofilcon A C3Senofilcon A C3/ Kalifilcon A/ Kalifilcon A
Started3633
Completed3633
Not completed00

Outcome measures

PrimaryHigh Luminance High Contrast (HLHC) Binocular logMAR Visual Acuity at Distance (4m)

Binocular visual acuity was measured on a logMAR (Logarithm of Minimal Angle of Resolution) scale under high luminance high contrast condition. At distance (4 meters), VA is assessed using ETDRS (Early Treatment Diabetic Retinopathy Study) charts; while near (40 cm) and intermediate (64 cm) assessments were made using reduced Guillon-Poling charts. Letter-by-letter results calculated the visual performance score for each chart read. LogMAR scores closer to zero, or below zero, indicate a better visual acuity. A logMAR visual performance score of 0.0 is equivalent to Snellen visual acuity of 20/20.

Time frame:
1-Week Follow-up
Reported as:
Mean · logMAR
High Luminance High Contrast (HLHC) Binocular logMAR Visual Acuity at Distance (4m)
logMARKalifilcon ASenofilcon A C3
High Luminance High Contrast (HLHC) Binocular logMAR Visual Acuity at Distance (4m)-0.058 ± 0.1013-0.071 ± 0.1002
Statistical analysis
  • Kalifilcon A vs Senofilcon A C3 · Mixed Models Analysis · Least square means difference: 0.014 · 95% CI -0.002 to 0.030Difference was calculated as kalifilcon A minus senofilcon A C3
PrimaryHigh Luminance High Contrast (HLHC) Binocular logMAR Visual Acuity at Intermediate (64cm)

Binocular visual acuity was measured on a logMAR (Logarithm of Minimal Angle of Resolution) scale under high luminance high contrast condition. At distance (4 meters), VA is assessed using ETDRS (Early Treatment Diabetic Retinopathy Study) charts; while near (40 cm) and intermediate (64 cm) assessments were made using reduced Guillon-Poling charts. Letter-by-letter results calculated the visual performance score for each chart read. LogMAR scores closer to zero, or below zero, indicate a better visual acuity. A logMAR visual performance score of 0.0 is equivalent to Snellen visual acuity of 20/20.

Time frame:
1-Week Follow-up
Reported as:
Mean · logMAR
High Luminance High Contrast (HLHC) Binocular logMAR Visual Acuity at Intermediate (64cm)
logMARKalifilcon ASenofilcon A C3
High Luminance High Contrast (HLHC) Binocular logMAR Visual Acuity at Intermediate (64cm)-0.045 ± 0.0968-0.049 ± 0.0912
Statistical analysis
  • Kalifilcon A vs Senofilcon A C3 · Mixed Models Analysis · Least square means difference: 0.004 · 95% CI -0.012 to 0.021Difference was calculated as kalifilcon A minus senofilcon A C3
PrimaryHigh Luminance High Contrast (HLHC) Binocular logMAR Visual Acuity at Near (40cm)

Binocular visual acuity was measured on a logMAR (Logarithm of Minimal Angle of Resolution) scale under high luminance high contrast condition. At distance (4 meters), VA is assessed using ETDRS (Early Treatment Diabetic Retinopathy Study) charts; while near (40 cm) and intermediate (64 cm) assessments were made using reduced Guillon-Poling charts. Letter-by-letter results calculated the visual performance score for each chart read. LogMAR scores closer to zero, or below zero, indicate a better visual acuity. A logMAR visual performance score of 0.0 is equivalent to Snellen visual acuity of 20/20.

Time frame:
1-Week Follow-up
Reported as:
Mean · logMAR
High Luminance High Contrast (HLHC) Binocular logMAR Visual Acuity at Near (40cm)
logMARKalifilcon ASenofilcon A C3
High Luminance High Contrast (HLHC) Binocular logMAR Visual Acuity at Near (40cm)0.076 ± 0.09990.069 ± 0.0980
Statistical analysis
  • Kalifilcon A vs Senofilcon A C3 · Mixed Models Analysis · Least square means difference: 0.007 · 95% CI -0.012 to 0.026Difference was calculated as kalifilcon A minus senofilcon A C3

Adverse events

Collected over Throughout the duration of the study, adverse events were monitored for approximately 32 days per subject.. Non-serious events are listed at a 5% frequency threshold.

Adverse event summary by group
GroupDeathsSeriousOther
Kalifilcon A0/70 (0%)0/70 (0%)0/70 (0%)
Senofilcon A C30/70 (0%)0/70 (0%)0/70 (0%)

Baseline characteristics

All subjects dispensed a study lens.

Age, Continuous
Age, Continuous(Years)Kalifilcon A/ Senofilcon A C3/ Senofilcon A C3Senofilcon A C3/ Kalifilcon A/ Kalifilcon ATotal
Mean55.8 ± 7.5655.7 ± 7.3855.7 ± 7.42
Sex: Female, Male
Sex: Female, Male(Participants)Kalifilcon A/ Senofilcon A C3/ Senofilcon A C3Senofilcon A C3/ Kalifilcon A/ Kalifilcon ATotal
Female292857
Male7613
Race (NIH/OMB)
Race (NIH/OMB)(Participants)Kalifilcon A/ Senofilcon A C3/ Senofilcon A C3Senofilcon A C3/ Kalifilcon A/ Kalifilcon ATotal
American Indian or Alaska Native000
Asian000
Native Hawaiian or Other Pacific Islander000
Black or African American6814
White302656
More than one race000
Unknown or Not Reported000
Region of Enrollment
Region of Enrollment(Participants)Kalifilcon A/ Senofilcon A C3/ Senofilcon A C3Senofilcon A C3/ Kalifilcon A/ Kalifilcon ATotal
United States363470
08

Study locations

7 sites
  • Dr. James Weber & Associates, PA - City Square Blvd
    Jacksonville, Florida 32218, United States
  • VRC
    Jacksonville, Florida 32256, United States
  • Pearson Research Center, PA
    Longwood, Florida 32779, United States
  • Maitland Vision Center - North Orlando Ave
    Maitland, Florida 32751, United States
  • Sacco Eye Group
    Vestal, New York 13850, United States
  • Luxe Vision and Optical
    Powell, Ohio 43065, United States
  • Dr. David W. Ferris & Associates
    Warwick, Rhode Island 02888, United States
09

References and documents

Study documents

PDFs hosted by the registry, ClinicalTrials.gov.

Individual participant data

Plan to share: Yes — Johnson \& Johnson Medical Device Companies have an agreement with the Yale Open Data Access (YODA) to serve as the independent review panel for evaluation of requests for clinical study reports and participant level data from investigators and physicians for scientific research that will advance medical knowledge and public health. Requests for access to the study data can be submitted through the YODA Project site at http://yoda.yale.edu

Data sharing details ↗ · yoda.yale.edu

10

Updates

1 registry update since Sep 25, 2026
Results
Results posted
posted Oct 15, 2026
Primary outcomes
3 edited
What changed in the outcomes
  • EditedHigh Luminance, High Contrast (HLHC) Binocular logMAR Visual Acuity at distanceDistance (4 meters4m)Time frame: 1-week follow-up → 1-Week Follow-up
  • EditedHigh Luminance, High Contrast (HLHC) Binocular logMAR Visual Acuity at intermediateIntermediate (64 cm64cm)Time frame: 1-week follow-up → 1-Week Follow-up
  • EditedHigh Luminance, High Contrast (HLHC) Binocular logMAR Visual Acuity at nearNear (40 cm40cm)Time frame: 1-week follow-up → 1-Week Follow-up
Oct 15, 2026
Documents
Show all 1 update
  1. Oct 15, 2026
    Results posted
    Primary outcomes 3 edited
    What changed in the outcomes
    • EditedHigh Luminance, High Contrast (HLHC) Binocular logMAR Visual Acuity at distanceDistance (4 meters4m)Time frame: 1-week follow-up → 1-Week Follow-up
    • EditedHigh Luminance, High Contrast (HLHC) Binocular logMAR Visual Acuity at intermediateIntermediate (64 cm64cm)Time frame: 1-week follow-up → 1-Week Follow-up
    • EditedHigh Luminance, High Contrast (HLHC) Binocular logMAR Visual Acuity at nearNear (40 cm40cm)Time frame: 1-week follow-up → 1-Week Follow-up
    + 2 other changes: index terms and verification date

From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗

11

Registry details

Key details

Study ID
NCT07076160
Responsible party
Sponsor
First posted
Jul 22, 2025
Start date
Jul 24, 2025
Primary completion
Sep 20, 2025
Completion
Sep 20, 2025
Results posted
Oct 15, 2026
Last update
Oct 15, 2026

Study contacts

Johnson & Johnson Vision Care, Inc. Clinical Trial
study director · Johnson & Johnson Vision Care, Inc.

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Oct 2026. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion