An observational study in Keratoconus, sponsored by Assiut University. Not yet recruiting. Open to participants aged 18 Years and older, including healthy volunteers. Per ClinicalTrials.gov, last updated 2025-04-07.
Sponsored by Assiut University · Observational
The cornea, as the outermost refractive structure of the eye, plays a critical role in maintaining clear vision. Its transparency and structural integrity are essential for optimal visual function. Among the layers of the cornea, the corneal epithelium is of particular interest due to its dynamic nature and its ability to remodel in response to various physiological and pathological conditions. Accurate and repeatable measurement of corneal epithelial thickness (CET) is therefore crucial for diagnosing and managing corneal diseases, such as keratoconus, and for planning refractive surgeries Keratoconus, a progressive corneal ectatic disorder, is characterized by thinning and protrusion of the cornea, leading to irregular astigmatism and visual impairment. Early detection and monitoring of keratoconus rely heavily on precise corneal imaging, including CET mapping. While AS-OCT has shown promise in evaluating CET in both healthy and keratoconic eyes, the repeatability of these measurements must be thoroughly evaluated to ensure their clinical utility Early diagnosis with subsequent corneal crosslinking (CXL) can slow-down or stop keratoconus progression.9 Identifying subclinical keratoconus is extremely important in refractive surgery screening to avoid iatrogenic ectasia. Anterior and posterior corneal topography combined with total cornea thickness measurements and localisation of the thinnest area are the parameters used commonly for diagnosing and staging of corneal ectasias. Recently, epithelial thickness is also added as an additional parameter and is shown to be useful for both early diagnosis and grading of keratoconus Corneal imaging is an essential tool in modern eye care. Initially, the curvature of the anterior corneal surface constituted the ground for the estimation of corneal optical properties and diagnosis of ectatic disorders like keratoconus. Gradually the importance of the posterior corneal curvature as well as its thickness gained significance. In recent years, new imaging devices allowing fast and high-resolution imaging of the entire anterior segment, cornea included started to emerge. The main advantages of the new generation Anterior Segment Optical Coherence Tomography (AS-OCT) are their superior acquisition speed, improved optical resolution (axial and transversal), as well as scanning depth and field of view .
High-resolution imaging of the cornea with AS-OCT provides thickness measurements individually for epithelium and stroma individually. Measuring corneal epithelial thickness adds information that could be of value in early diagnosis, progression evaluation and maybe even for a more complete understanding of the pathophysiology of this disease. It has been shown that changes in the corneal epithelial thickness could be a sensitive tool for early keratoconus detection as well as for the assessment of the disease progression.
Precise measurements of the epithelial thickness are therefore important for keratoconus diagnosis and follow-up. AS-OCTs have high axial resolution and studies have shown that these instruments provide repeatable epithelial measurements both in central and peripheral cornea. With an additional lens (anterior segment module), posterior segments OCTs can also be used to measure corneal parameters including epithelial thickness1and previous studies have shown that these modules can also produce precise epithelial thickness measurements in healthy corneas and in keratoconus. There is only limited information on how the precision of epithelial measurements with the anterior module in posterior segment OCTs compares to the precision of epithelial measurements with AS-OCTs Aim of this study Detect early-stage keratoconus by identifying suitable epithelial thickness changes before topographic abnormalities appear .
313 studies on the registry are indexed under Keratoconus; 56 are open to participants now.
This study's planned enrollment of 150 is above the median of 130 across 97 observational studies indexed under Keratoconus.
Browse Keratoconus studies →Assiut University is the lead sponsor of 5,078 studies on the registry; 2,178 are open to participants now.
Of its 14 completed or terminated interventional studies of FDA-regulated products, 0 (0%) have results posted.
Counted across the registry records on this site, refreshed daily.
patients will be divided into three groups: healthy individuals , patients with keratoconus and suspicious keratoconus patient
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Healthy participants with normal corneal topography and no ocular abnormalities intended to do LASIK.
Exclusion Criteria:
History of corneal surgery or trauma.
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Control Group who intended to do LASIK (N=50)
Keratoconus Group (N=50)
Suspicious keratoconus by pentacam ( N=50)
epithelial thickness maps
From the pachymetry map, we measured the central corneal thickness, and from the epithelial map, we measured central epithelial thickness, thickest location, thinnest location, and their distributionespecially in its subclinical or early stages.
Time frame: baseline
No study locations are listed for this record.
This study is not yet recruiting, as verified in Apr 2025. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.