An interventional study of OrbusNeich Scoreflex TRIO and OrbusNeich Scoreflex NC in Coronary Arteriosclerosis, sponsored by OrbusNeich. Completed at 4 sites in China. Open to participants aged 18 Years to 80 Years. Per ClinicalTrials.gov, last updated 2024-08-26.
Sponsored by OrbusNeich · Not applicable, Interventional, and Treatment
To evaluate the acute safety and device procedural success of the Scoreflex TRIO Scoring PTCA catheters versus Scoreflex NC Scoring PTCA catheters in subjects with stenotic coronary arteries during percutaneous coronary intervention.
This is a prospective, multi-center, open-label, non-inferiority, randomized controlled trial which plans to enroll 210 subjects. All subjects enrolled will be randomly assigned to the test group (n=105) and the control group (n=105). Subjects in the test group and the control group will receive Scoreflex TRIO Scoring PTCA catheters and Scoreflex NC Scoring PTCA catheters respectively.
Subjects must have a single or double vessel coronary artery disease (CAD) and clinical evidence of ischemic heart disease, such as CAD, stable / unstable angina or silent ischemia, need percutaneous coronary intervention.
Angiographic Inclusion Criteria
Exclusion Criteria:
Other conditions assessed by the investigator as inappropriate to participate in this trial.
Angiographic Exclusion Criteria
Non-target lesion to be treated during the index procedure meets any of the following criteria:
OrbusNeich Scoreflex TRIO Scoring PTCA catheters
Device: OrbusNeich Scoreflex TRIO
OrbusNeich Scoreflex NC Scoring PTCA catheters
Device: OrbusNeich Scoreflex NC
To dilate coronary arteries during the subject's index procedure with Scoreflex TRIO Scoring PTCA catheters
To dilate coronary arteries during the subject's index procedure with Scoreflex NC Scoring PTCA catheters
Rate of device Procedural Success
Device procedural success consisting of the following: * Successful delivery, inflation, deflation, and withdrawal of the device * No evidence of vessel perforation, flow limiting dissection (grade C or higher) or reduction in Thrombolysis In Myocardial Infarction (TIMI) flow from baseline as related to the devices * Residual stenosis of target lesion \<50% after balloon angioplasty, Final TIMI flow grade of 3 at the conclusion of the percutaneous coronary intervention (PCI) procedure
Time frame: Peri-procedural (at Day 0)
Improvement in Minimum Lumen Diameter (MLD) following use of Scoreflex NC catheter (measured by QCA).
Improvement in MLD is defined as MLD post use of Scoreflex as greater than MLD from baseline.
Time frame: Peri-procedural (at Day 0)
In-hospital Major Adverse Cardiac Events (MACE)
In-hospital Major Adverse Cardiac Events (MACE), a composite of: Cardiac death, Myocardial Infarction (MI), Target Lesion Revascularization (TLR), clinically driven.
Time frame: Endpoints will be measured through hospital discharge (expected to be within 24 hours)
Device-oriented target lesion failure (TLF)
The device-oriented target lesion failure (TLF) is defined as a composite of cardiac death, target vessel myocardial infarction (MI), and ischemia-driven target lesion revascularization (i-TLR)
Time frame: 30 days
Patient-oriented composite endpoint
The patient-oriented composite endpoint includes all-cause death, all MIs, or any revascularization.
Time frame: 30 days
Plan to share: No
No publications or documents are linked to this record.
This study is completed, as verified in Aug 2024. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
OrbusNeich