An interventional study of Self-expanding valve (Medtronic Evolut FX) and Balloon-expanding valve (Edwards Sapien 3 Ultra RESILIA) in Aortic Valve Stenosis, sponsored by University Hospitals Cleveland Medical Center. Recruiting at 1 site in United States. Open to participants aged 18 Years to 105 Years. Per ClinicalTrials.gov, last updated 2025-12-17.
Sponsored by University Hospitals Cleveland Medical Center · Not applicable, Interventional, and Treatment
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 189 studies in Aortic Valve Stenosis with a site in United States — 43 open to participants now, 67 under way, 3 of them phase 3. Aortic Valve Stenosis · United States.
Among the 189 studies in Aortic Valve Stenosis with a site in United States, this one is the 75th largest by planned enrollment of the 125 interventional ones that give a count, is one of 12 that started in 2023, is one of 102 with no phase, reaches primary completion later than 29 of the 66 other live ones, and was the 148th registered.
1,028 studies on the registry are indexed under Aortic Valve Stenosis; 295 are open to participants now.
Browse Aortic Valve Stenosis studies →43 of the 189 studies in Aortic Valve Stenosis with a site in United States are open now. Recruiting first, the newest first:
American College of Cardiology · Sites in United States
Ages 18+
EmStop Inc · Sites in United States
Ages 22+
Dermed Diagnostics, Inc. · Sites in United States
Ages 18+
Columbia University · Sites in United States
Ages 18+
MiRus · Sites in United States
Ages 18+
A study can be open while its sites in United States have not opened yet or have stopped. Only those recruiting at a site in United States →
Of the 209 Aortic Valve Stenosis studies recruiting now, 163 (78%) set no upper age limit and 9 (4%) stop at 75 or younger; 24 take children under 18; 14 take healthy volunteers.
This study: 18 Years to 105 Years · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
189 studies; the count open now beside each. This study's row is marked.
A study in two phases is counted once above. Listed by phase, each with its combined phases: Phase 1 5 · Phase 2 7 · Phase 3 7 · Phase 4 6
First in 2000; this study’s year is marked. 12 started in 2023.
By drug class, each counting the studies that test any of its medicines:
This study's planned enrollment of 90 is below the median of 126 across 555 interventional studies indexed under Aortic Valve Stenosis.
Median enrollment 172 across the 125 interventional studies, 102 across the 64 observational. Of the 107 that completed or were terminated, 50 (47%) have results posted.
This tab as a report to print or save as PDF → With an account.
82 of 189 have an industry lead sponsor. The 10 most frequent:
University Hospitals Cleveland Medical Center is the lead sponsor of 296 studies on the registry; 46 are open to participants now.
Of its 36 completed or terminated interventional studies of FDA-regulated products, 30 (83%) have results posted.
University Hospitals Cleveland Medical Center has 2 studies filed under Aortic Valve Stenosis — fewer than ten, so there is no comparison to draw.
13 of the studies in Aortic Valve Stenosis with a site in United States that are under way reach primary completion within a year, 0 of them phase 3. Phase 3 first, then by date:
| Study | Primary completion |
|---|---|
| NCT06689839EnCompass Technologies, Inc.Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR | 2026-12 |
| NCT05603026University Hospitals Cleveland Medical CenterMRI in Transcatheter Aortic Valve Replacement Patients | 2026-12-30 |
| NCT07827105AccurKardia, Inc.ECG-based AI Screening for Cases of Undiagnosed Moderate-to-Severe Aortic Stenosis in the Primary Care Setting | 2027-02 |
| NCT06077201Vanderbilt University Medical CenterHome-Based Cardiac Rehabilitation Using a Novel Mobile Health Exercise Regimen Following Transcatheter Heart Valve Interventions | 2027-02-01 |
| NCT06580158Mayo ClinicAI in Outpatient Practice for Diagnosing Aortic Stenosis and Diastolic Dysfunction | 2027-03 |
Add all 13 to your calendar (.ics) → With an account.
Among the 189 studies in Aortic Valve Stenosis with a site in United States, from their registry updates:
This tab as a report to print or save as PDF → With an account.
The hypothesis is that SEV result in superior valvular hemodynamics (more pronounced during exercise) and exercise capacity relative to BEV. Furthermore, the hypothesis is that stress CMR will be able to demonstrate differences in these hemodynamic parameters. CMR will also provide refined assessment of paravalvular leak and its impact on ventricular function and on clinical outcomes.
Project Overview/Summary Transcatheter aortic valve replacement (TAVR) is an alternative to open heart surgery for the treatment of severe aortic stenosis, and has recently been approved for low surgical risk patients. This has resulted in a shifting of TAVR patient demographics to younger and more active individuals. It is, therefore, imperative to deliver excellent hemodynamics after valve replacement to enable patients to recover an active lifestyle with enhanced exercise capacity. Several studies, mostly conducted with resting echocardiogram have suggested self-expanding valves (SEV) Evolut R, Evolut PRO, Evolut PRO+ (Medtronic , Minneapolis, MN) are associated with favorable hemodynamics, which may allow for improved exercise capacity in active patients.
Currently, there are different TAVR valves are commercially available in the United States. The Sapien 3 valve (Edwards Lifesciences, Irvine, CA) is an annular, balloon expandable valve (BEV) and the Evolut PRO+ valve features a supra-annular design and is a SEV. A recent study utilizing resting echocardiogram demonstrated better hemodynamics of supra-annular SEV compared with BEV, mostly in patients with smaller annuli.
Cardiac magnetic resonance (CMR) has emerged as an important tool in the non-invasive assessment of patients with valvular heart disease. While CMR has been used for the diagnosis and quantification of valvular heart disease, there is a paucity of data on its use for the assessment of valvular hemodynamics in the post TAVR setting. Furthermore, it would be of utmost importance to understand how these devices perform during exertion. Of note, cardiac magnetic resonance techniques permit quantification of the myocardial extracellular volume fraction (ECV), representing a surrogate marker of reactive interstitial fibrosis, and late gadolinium enhancement (LGE), representing replacement fibrosis or scar. ECV and LGE have been independently linked with heart failure (HF) events.
Several studies have demonstrated that non-invasive CMR can be used to calculate non-invasive pressure-volume loops using cine imaging and non-invasive brachial blood pressure. This enables assessment of myocardial performance beyond LVEF. CMR-derived myocardial stroke work is a novel method allowing non-invasive assessment of total active myocardial performance, including both constructive and wasted myocardial work. Specifically, changes in LV stroke work have been shown to carry important prognostic information following TAVR.
Hypothesis The hypothesis is that SEV result in superior valvular hemodynamics (more pronounced during exercise) and exercise capacity relative to BEV. Furthermore, the hypothesis is that stress CMR will be able to demonstrate differences in these hemodynamic parameters. CMR will also provide refined assessment of paravalvular leak and its impact on ventricular function and on clinical outcomes.
STUDY DESIGN
Study Population There will be enrolled prospectively and retrospectively patients who have undergone TAVR at University Hospitals Cleveland Medical Center with different commercially available transcatheter valves and different sizes. It will then be screened all patients undergoing TAVR for a total of 90 patients.
All patients referred for TAVR will be considered for enrollment provided they meet the following inclusion and exclusion criteria. Inclusion criteria include all of the following: 1) Aortic valve stenosis with clinical indication for valve replacement decided by a dedicated heart team; 2) Planned transfemoral TAVR; 3) 18 years of age or older; 4) Able to give informed consent.
Exclusion criteria will include: 1) Patients with permanent pacemakers or implantable defibrillators; 2) Patients with non-MRI safe implants; 3) Severe claustrophobia; 4) Inability or contraindication to perform exercise bike stress test; 5) Arrhythmia which would prevent adequate cardiac gating, including atrial fibrillation; 6) Reduced left ventricular systolic function (\<40%); 7) History of surgical aortic valve replacement or patients who undergo a valve-in-valve TAVR procedures; 8) Significant non-treated coronary artery disease.
Primary and Secondary Outcomes The co-primary endpoints will be analysed at 1-year follow up and will consist in: change in effective orifice area (EOA), mean gradient and peak gradient over time between valve types; and left ventricular stroke work.
Secondary outcomes will include: myocardial fibrosis; myocardial extra-cellular volume fraction; ability to perform stress CMR studies in post TAVR patient population, exercise capacity post TAVR, echocardiographic measures of valve and heart function, standard clinical outcomes of morbidity and mortality associated with TAVR.
Patient Enrollment, Treatment, and Follow-up Patients will be screened for inclusion/exclusion criteria as part of their pre-TAVR clinical evaluation. We will screen all patients undergoing TAVR for a total of 90 patients. There will be enrolled 45 patients to undergo TAVR and receive Sapien 3 BEV with two sizes (23 mm and 26 mm) and 45 patients to undergo TAVR with Evolut FX SEV in two available sizes (26 mm and 29 mm). All patients will be required to sign an informed consent. The choice for TAVR valve will be at the operator's discretion. Patients will be seen at 7- and 30-days post TAVR per routine clinical practice.
Baseline clinical parameters, procedural variables and the occurrence of MACE and bleeding events will be determined by history and corroborated by examining relevant medical records.
Transthoracic echocardiography will be performed immediately post TAVR, 1-day post TAVR and again at 30-days post TAVR as per standard clinical protocol. Patients will be treated with aspirin 81 mg daily and clopidogrel 75 mg daily for a minimum of 3 months, followed by aspirin 81 mg daily indefinitely thereafter.
MRI Imaging Protocol The first CMR will be performed up to three months prior to the TAVR procedure. Secondly, a stress CMR study will be performed 30-days (up to three months) post TAVR. Patients will have their EOA, valvular regurgitation, LV function, mean pressure gradient and peak pressure gradient assessed by standard MRI protocols. Patients will undergo an exercise stress MRI to assess exercise capacity, valve hemodynamics under stress and differences in hemodynamics between valve types. Finally, a follow up CMR will be performed 1-year after the TAVR, where it will be evaluated myocardial extracellular volume fraction and replacement fibrosis/scar in addition to the variables previously described.
CMR-Derived Non-invasive LV Pressure-Volume Loops It will be the able to calculate non-invasive pressure-volume loops using cine imaging and non-invasive brachial blood pressure. LVPV loops are derived non-invasively with ventricular-volume, heart rate and brachial pressure as inputs. LV stroke work is derived from the area of the generated pressure-volume loop.
MRI Stress Protocol The exercise MRI test will be performed on an MRI-compatible supine cycle ergometer that will be attached to the end of the MRI bed. Patients will be positioned on the gentry with a molding pad placed beneath them to help maintain patient position on the table during exercise for pre- and post-exercise scans. After initial imaging, the patient will remain supine on the table to complete the symptom-limited exercise stress test. Heart rate and blood pressure will be monitored continuously throughout exercise and during post-exercise scans. Immediately post-exercise, the patient will be placed back in the scanner for post-exercise.
Patient Safety Patients will be monitored for adverse events (AE) and serious adverse events (SAE). A data safety and monitoring board will be appointed to oversee and adjudicate these events. An AE is the development of an undesirable medical condition or the deterioration of a pre-existing medical condition following or during exposure to a pharmaceutical product, whether or not considered causally related to the product. Patients undergoing MRI and stress CMR will be screened for relevant contraindications by the research team at the time of their scan. SAE is an AE that results in death, requires in-patient hospitalization or prolongation of existing hospitalization, results in persistent or significant disability, results in a congenital abnormality or birth defect, or is an important medical event that may jeopardize the subject or may require medical intervention to prevent one of the outcomes listed above. The causality of SAEs (their relationship to all study treatments) will be assessed by the investigators. The following variables will be collected for each AE: 1) Type of AE, 2) Date and time when the AE started and stopped, 3) Whether the AE is serious or not, 4) Investigator causality rating against the investigational product, 5) Action taken with regard to investigational product, 6) Whether AE caused subject's withdrawal from the study, 7) Outcome. The following variables will be collected for each SAE: 1) Date AE met criteria for serious AE, 2) Date Investigator became aware of serious AE, 3) Reason AE is serious, 4) Date of hospitalization if applicable, 5) Date of discharge, if applicable, 6) Probable cause of death, if applicable, 7) Date of death, if applicable, 8) Autopsy performed, if applicable, 9) Causality assessment in relation to Study procedure(s), 10) Causality assessment in relation to other medication, 11) Description of AE.
Risks:
The only foreseeable risk of this study are:
Benefits:
Through registry based analysis it will be isolated clinical determinants of morbidity and mortality, as well as the best clinical and procedural outcomes, which will inform best practices for TAVR procedures.
Statistical Analysis:
Continuous variables will be reported as median (interquartile range) and categorical variables as number (percentage). Cumulative survival free from outcomes will be assessed by Kaplan-Meier (KM) curves and Cox proportional hazard ratios will be calculated to create predictive and association models for the outcomes of interest. P-values of ≤0.05 will be considered statistically significant. Statistical analyses will be done using SAS, version 9.3 (SAS Institute, Cary, NC).
Data Safety Monitoring Plan:
The Principal Investigator will ensure that all the data is securely collected and stored in a password protected REDCap database. Each patient reviewed will be de-identified by a specific study number and names and MR numbers will not be used in the final statistical analysis. It will be ensured that after statistical analysis there is no means of connecting any patient reviewed to specific data associated with that patient.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Contraindication
A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Transcatheter aortic valve replacement (TAVR) using the bioprosthesis Medtronic Evolut FX supra-annular self-expanding valve
Device: Self-expanding valve (Medtronic Evolut FX)
Transcatheter aortic valve replacement (TAVR) using the bioprosthesis Edwards Sapien 3 Ultra valve
Device: Balloon-expanding valve (Edwards Sapien 3 Ultra RESILIA)
Bioprothesis Medtronic Evolut FX supra-annular self-expanding valve
Bioprosthesis Edwards Sapien 3 Ultra valve
Effective orifice area (EOA)
Change in effective orifice area (EOA) assessed by CMR between baseline and 1-year follow up (cm2)
Time frame: Baseline, 30-days and 1-year
Mean gradient
Mean AV gradient assessed by CMR (mmHg)
Time frame: 1-year
Peak gradient
Mean AV gradient assessed by CMR (mmHg)
Time frame: 1-year
Myocardial fibrosis
Myocardial fibrosis assessed by CMR (grams)
Time frame: 1-year
Myocardial extra-cellular volume fraction
Myocardial extra-cellular volume fraction assessed by CMR (Liters)
Time frame: 1-year
Stress CMR feasibility
Ability to perform stress CMR studies in post TAVR patient population (yes or no)
Time frame: 30-days
Exercise capacity post TAVR
Exercise capacity post TAVR assessed by CMR (METs)
Time frame: 30-days
Mean gradient by echo
Mean gradient assessed by transthoracic echocardiography (mmHg)
Time frame: 1-year
EOA by echo
Effective orifice area assessed by transthoracic echocardiography (cm2)
Time frame: 1-year
Ejection fraction by echo
Left ventricle ejection fraction assessed by transthoracic echocardiography (%)
Time frame: 1-year
Composite of morbidity and mortality associated with TAVR
Number of composite outcomes of morbidity and mortality associated with TAVR (number)
Time frame: 1-year
Plan to share: No
No publications or documents are linked to this record.
Started Nov 2023 (actual). Primary completion is estimated for Dec 2026, 37 months after the start.
Of 177 non-industry interventional studies with no phase under Aortic Valve Stenosis, half reached primary completion within 47 months of starting (the median), counting those still running; a quarter within 23 and three quarters within 79. This study's planned 37 months is below that.
Counting every sponsor, half of 288 studies reached it within 33 months; a quarter within 18 and three quarters within 71.
How these figures are worked out, and which studies are left out of them.
Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.
Contact study teamGet an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
University Hospitals Cleveland Medical Center →