An observational study in Aortic Valve Stenosis, Aortic Valve Calcification and Aortic Diseases, sponsored by Boston Scientific Corporation. Terminated at 20 sites in 8 countries. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2026-11-24.
Sponsored by Boston Scientific Corporation · Observational
Device Withdrawn from the market
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 29 studies in Aortic Valve Stenosis by Boston Scientific Corporation — none open to participants now, 1 under way, none of them phase 3. Aortic Valve Stenosis · Boston Scientific Corporation.
Among the 29 studies in Aortic Valve Stenosis by Boston Scientific Corporation, this one is the 5th largest by enrollment of the 10 observational ones that give a count, is one of 2 that started in 2020, is one of 10 observational ones, and was the 27th registered.
1,031 studies on the registry are indexed under Aortic Valve Stenosis; 297 are open to participants now.
Browse Aortic Valve Stenosis studies →None of the 29 studies in Aortic Valve Stenosis by Boston Scientific Corporation is open now. The open studies under Aortic Valve Stenosis, anywhere →
Of the 210 Aortic Valve Stenosis studies recruiting now, 164 (78%) set no upper age limit and 9 (4%) stop at 75 or younger; 24 take children under 18; 14 take healthy volunteers.
This study: 18 Years and older · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
29 studies; the count open now beside each. This study's row is marked.
First in 2009; this study’s year is marked. 2 started in 2020.
This study's enrollment of 250 is above the median of 200 across 438 observational studies indexed under Aortic Valve Stenosis.
Median enrollment 40 across the 19 interventional studies, 250 across the 10 observational. Of the 25 that completed or were terminated, 6 (24%) have results posted.
This tab as a report to print or save as PDF → With an account.
Boston Scientific Corporation is the lead sponsor of 528 studies on the registry; 40 are open to participants now.
Of its 65 completed or terminated interventional studies of FDA-regulated products, 57 (88%) have results posted.
None of the studies under way reaches primary completion within a year.
Among the 29 studies in Aortic Valve Stenosis by Boston Scientific Corporation, from their registry updates:
This tab as a report to print or save as PDF → With an account.
The ACURATE Neo2 PMCF is aimed at collecting clinical and device performance outcomes data with the ACURATE neo2™ Transfemoral Aortic Valve System as used in routine clinical practice for the treatment of severe calcific aortic stenosis.
ACURATE neo2 PMCF is a prospective, open-label, single-arm, multicenter, observational post-market surveillance study. All subjects deemed treatable with the ACURATE neo2 valve will be approached to participate in the study.
A subject who provides an Informed Consent Form (ICF) approved by the Independent Ethics Committee (IEC) and signed by the subject or the subject's legally authorized representative is considered enrolled once an attempt is made to insert the commercially available ACURATE neo2 Transfemoral Delivery System. Approximately 200 subjects will be enrolled.
Follow-up will occur at pre-discharge, 30 days, 1 year, and then annually from 2 through 5 years post index procedure per standard of care. Visits are in-person through 1 year and in-person (preferred) or via telephone interview in years 2 through 5. All subjects will undergo 4D computed tomography (CT) imaging at 30 days and 1 year.
ACURATE neo2 PMCF Study Design Overview Abbreviations: CT=computed tomography; ICF=Informed Consent Form
Patients with symptomatic heart disease due to severe native calcific aortic stenosis
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
There are no specific inclusion criteria set for this post-market surveillance study. A subject must sign an IEC-approved ICF and the ACURATE neo2 Transfemoral Aortic Valve System should be used according to the commercial IFU.
Exclusion Criteria:
EC1. Subject has a previous bioprosthesis in the aortic position.
EC2. Subject has \<30 mL/min (chronic kidney disease stage IV or stage V).
EC3. Subject has atrial fibrillation that cannot be rate controlled to ventricular response rate \< 60 bpm.
EC4. Subject is expected to undergo chronic anticoagulation therapy after the TAVI procedure
Note : Subjects treated with short-term anticoagulation post-procedure can be included; in these subjects the 30-day imaging will be performed 30 days after discontinuation of anticoagulation.
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
GFR (glomerular filtration rate) is how much blood the kidneys filter each minute. It is usually estimated from a blood test — eGFR, by formulas such as CKD-EPI or MDRD — and some studies ask for it to be measured directly instead. Usually given in mL/min/1.73 m².
Check the method, the units and the minimum the study states. A value of 90 or above is in the normal-or-high range, but kidney damage can show in other tests too.
GFR and eGFR (kidney filtering)
GFR (glomerular filtration rate) is how much blood the kidneys filter each minute. It is usually estimated from a blood test — eGFR, by formulas such as CKD-EPI or MDRD — and some studies ask for it to be measured directly instead. Usually given in mL/min/1.73 m².
Check the method, the units and the minimum the study states. A value of 90 or above is in the normal-or-high range, but kidney damage can show in other tests too.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
The device is placed in patients heart at the level of aortic valve through a transfemoral access from femoral groin as indicated in device IFU
Primary Safety Endpoint:
All-cause mortality after the index implant procedure
Time frame: 30 days
Primary Imaging Endpoint:
Hypoattenuated leaflet thickening (HALT) as measured by 4D CT
Time frame: 30 days
Safety endpoints adjudicated by an independent Clinical Events Committee
All-cause mortality (cardiovascular and non-cardiovascular) Stroke (disabling and non-disabling) Bleeding (life-threatening \[or disabling\] and major) Vascular complications (major) Hospitalization for valve-related symptoms or worsening congestive heart failure (NYHA class III or IV)
Time frame: all 5 years
Additional Safety Endpoints
* Myocardial infarction (periprocedural \[≤72 hours post index procedure\] and spontaneous \[\>72 hours post index procedure\]) * Acute kidney injury (≤7 days post index procedure) based on the AKIN System Stage 3 (including renal replacement therapy) and Stage 2 * Repeat procedure for valve-related dysfunction (surgical or interventional therapy) * New permanent pacemaker implantation resulting from new or worsened conduction disturbances * New onset of atrial fibrillation or atrial flutter * Coronary obstruction (≤3 days post index procedure) * Ventricular septal perforation (≤3 days post index procedure) * Annular rupture (≤3 days post index procedure) * Cardiac tamponade (≤3 days post index procedure) * Valve migration * Valve embolization * Ectopic valve deployment * Transcatheter aortic valve (TAV)-in-TAV deployment * Prosthetic aortic valve thrombosis * Prosthetic aortic valve endocarditis
Time frame: all 5 years
Prosthetic Aortic Valve Performance as measured by transthoracic echocardiography (TTE)
Effective orifice area (EOA), Mean and Peak aortic gradients, peak aortic velocity, and grade of aortic regurgitation/paravalvular leak (PVL). Center-reported TTE measures will also be collected annually at 2 through 5 years per local standard of care for TAVI.
Time frame: Discharge, 30 days, annually from year 1 to 5
EuroQoL Quality of Life questionnaire (EQ-5D-5L)
Health status as evaluated by the EQ-5D-5L Quality Of Life questionnaire
Time frame: Baseline, 30-day, 1-year
New York Heart Association (NYHA) functional classification
Classification of heart failure symptoms as evaluated by NYHA classification
Time frame: Baseline, Discharge, 30 days, annually from year 1 to 5
Assessments using 4D CT-scan
* Assessment of leaflet mobility * Assessment of hypoattenuated leaflet thickening (HALT) * Assessment of leaflet thrombosis
Time frame: 30 days 1 year
Plan to share: Undecided — The data and study protocol for this clinical trial may be made available to other researchers in accordance with the Boston Scientific Data Sharing Policy. (http://www.bostonscientific.com/en-US/data-sharing-requests.html)
Ran from Dec 2020 to primary completion in Mar 2022, 14 months.
Completion moved once since we started tracking on Sep 25, 2026: Dec 2026 → Jul 2025, on Nov 24, 2026.
Earlier changes are on the record history on ClinicalTrials.gov ↗
How these figures are worked out, and which studies are left out of them.
Device Withdrawn from the market
Device Withdrawn from the market
From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗
This study is terminated, as verified in Nov 2026. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Boston Scientific Corporation →