ClinicalTrials.gg
CompletedNCT04175626BIOFLOW-VIIUpdated Feb 27, 2026Results posted

Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in Subjects With Coronary Artery Lesions

An observational study in Coronary Artery Disease, Atherosclerosis, Coronary and Myocardial Ischemia, sponsored by Biotronik, Inc.. Completed at 33 sites in United States. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2026-02-27.

Sponsored by Biotronik, Inc. · Observational

How we know

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Study type
Observational
Model
Cohort
Time perspective
Prospective
Enrollment
556
Ages
18 Years and older
Sex
All
01

Where this study stands

Counted across the records on this site · 2026-11-27

Among 37 studies in Coronary Artery Disease by Biotronik SE & Co. KG — 1 open to participants now, 5 under way, none of them phase 3. Coronary Artery Disease · Biotronik SE & Co. KG.

Enrollment
10th of 20
556 · median 528
Started
2020
with 4 others
Observational
20 of 37
1 open now
Registered
34th of 37
by date

Among the 37 studies in Coronary Artery Disease by Biotronik SE & Co. KG, this one is the 10th largest by enrollment of the 20 observational ones that give a count, is one of 5 that started in 2020, is one of 20 observational ones, and was the 34th registered.

Coronary Artery Disease

4,876 studies on the registry are indexed under Coronary Artery Disease; 897 are open to participants now.

Browse Coronary Artery Disease studies →

Open to participants now

1 of the 37 studies in Coronary Artery Disease by Biotronik SE & Co. KG is open now, in 7 countries. Recruiting first, the newest first:

By country, each count listing its studies:

Who these studies take

Of the 594 Coronary Artery Disease studies recruiting now, 406 (68%) set no upper age limit and 67 (11%) stop at 75 or younger; 37 take children under 18; 49 take healthy volunteers.

This study: 18 Years and older · all sexes · no healthy volunteers.

The full table on the hub →

This tab as a report to print or save as PDF → With an account.

Was this useful?
Get alerts for this landscapeDownload CSVNarrow it in search →With an account: a weekly mail of what changed among 37 studies in Coronary Artery Disease by Biotronik SE & Co. KG, or all of them as a file.
02

Study summary

The objective of this post-approval study is to confirm that the clinical performance of the Orsiro stent in a real-world setting is similar to the clinical performance observed for Orsiro in the BIOFLOW-V Investigational Device Exemption pivotal trial, as a condition of the US Food and Drug Administration (FDA) approval (P170030).

Read the detailed description

BIOFLOW-VII is a prospective, multicenter, single-arm study. Subjects with coronary artery disease (CAD) who undergo an on-label percutaneous coronary intervention (PCI) with a placed Orsiro stent within the prior 24 hours will be screened post-index procedure per the protocol inclusion and exclusion criteria.

Following the index procedure and study enrollment, subjects will be followed for 5 years. The follow-up schedule will include an intermediate study visit at 1 month, a primary endpoint study visit at 12 months, and long-term study visits at 2, 3, 4, and 5 years.

03

Conditions studied

  • Coronary Artery Disease
  • Atherosclerosis, Coronary
  • Myocardial Ischemia
  • Ischemic Heart Disease
  • Acute Coronary Syndrome
  • Angina Pectoris

Keywords

  • Drug eluting coronary stents
  • Sirolimus
  • Bioabsorbable polymer
  • DES
04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No
Sampling method
Non-probability sample

Study population

Subjects with coronary artery disease (CAD), including those with diabetes mellitus, with symptomatic heart disease, stable angina, unstable angina, non-ST elevation myocardial infarction or documented silent ischemia due to atherosclerotic lesions in the native coronary arteries with a reference vessel diameter of 2.25 mm to 4.0 mm and a lesion length of ≤ 36 mm.

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  1. Subject is ≥18 years of age.
  2. Subject was an acceptable candidate for treatment with a drug eluting stent at the qualifying index procedure, in accordance with the applicable guidelines on percutaneous coronary interventions and manufacturer's Instructions for Use.
  3. Subject received at least one Orsiro stent during an index procedure occurring within 24 hours prior to , as assessed by the end time of procedure. If more than one stent was implanted during the index procedure, all stents were Orsiro stents.
  4. Subject is eligible for dual antiplatelet therapy (DAPT) treatment with aspirin plus either clopidogrel, prasugrel, ticagrelor or ticlopidine.
  5. Subject is willing to comply with study follow-up requirements.
  6. Subject has provided written informed consent as approved by the Institutional Review Board (IRB) of the respective clinical site. Legally authorized representatives are not allowed to consent on a subject's behalf.

Each target lesion/vessel must have met all of the following angiographic criteria from the index procedure for the subject to be eligible for the trial:

  1. Subject has up to three target lesions in up to two separate target vessels (two target lesions in one vessel and one target lesion in a separate vessel).
  2. Target lesion must be de novo or restenotic lesion in native coronary artery; restenotic lesion must have been treated with a standard PTCA only.
  3. Target lesion must be in major coronary artery or branch (target vessel).
  4. Target lesion must have angiographic evidence of ≥ 50% and \< 100% stenosis (by operator visual estimate). If the target lesion is \< 70% stenosed, there should be clinical evidence of ischemia.
  5. Target vessel must have a Thrombolysis In Myocardial Infarction (TIMI) flow > 1.
  6. Target lesion must be ≤ 36 mm in length by operator visual estimate.
  7. Target vessel must have a reference vessel diameter of 2.25-4.0 mm by operator visual estimate.
  8. Target lesion must have been treated with a maximum of two overlapping stents.

Exclusion criteria

Exclusion Criteria:

  1. Subject had clinical symptoms and/or (ECG) changes consistent with acute ST elevation MI (STEMI) within 72 hours prior to the index procedure.
  2. Subject is pregnant and/or breastfeeding or intends to become pregnant during the duration of the study.
  3. Subject has a known allergy to contrast medium that cannot be adequately pre-medicated, or any known allergy to thienopyridine, aspirin, both heparin and bivalirudin, L-605 cobalt-chromium (Co-Cr) alloy or one of its major elements (cobalt, chromium, tungsten and nickel), silicon carbide, PLLA, sirolimus.
  4. Revascularization of any target vessel within 9 months prior to the index procedure or previous PCI of any non-target vessel within 30 days prior to the index procedure or any PCI planned within the next 1 year.
  5. Presence of an untreated stenosis post-procedure whether treatment is planned or not.
  6. Planned surgery within 6 months of index procedure unless DAPT can be maintained throughout the peri-surgical period.
  7. History of a stroke or (TIA) within 6 months prior to the index procedure.
  8. Subject has documented \< 30% prior to consent.
  9. Subject is dialysis-dependent.
  10. Subject has impaired renal function (blood creatinine > 2.5 mg/dL or 221 μmol/L prior to the index procedure).
  11. Subject has leukopenia (i.e. \< 3,000 white blood cells/mm3), thrombocytopenia (i.e. \< 100,000 /mm3) or thrombocytosis (i.e. > 700,000 platelet/mm3).
  12. Any significant concurrent medical diagnosis that would potentially impact DAPT effectiveness or increase thrombotic risk.
  13. Subject is receiving chronic anticoagulation (e.g. coumadin, dabigatran, apixaban, rivaroxaban or any other agent).
  14. Subject has of \< 1 year.
  15. Subject is participating in an (medical device or drug) clinical study. Subjects may be concurrently enrolled in a post-market study, as long as the post-market study device, drug or protocol does not interfere with the follow-up requirements of this study or does not involve a drug that may confound the interpretation of any relevant clinical events of interest (e.g. investigational DAPT therapy).
  16. In the investigator's opinion, subject will not be able to comply with the follow-up requirements.

Subjects will be excluded from the trial if any of the target lesions/vessels met any of the following angiographic criteria during the index procedure:

  1. Target lesion was located within or treated through a saphenous vein graft or arterial graft.
  2. Target lesion was a restenotic lesion that was previously treated with a bare metal or drug-eluting stent (in-stent restenosis).
  3. Target lesion had any of the following characteristics:

    1. Lesion location is within the left main coronary artery, or within 3 mm of the origin of the left anterior descending (LAD) or left circumflex (LCX).
    2. Involves a side branch of > 2.0 mm in diameter.
  4. Target vessel/lesion was excessively tortuous/angulated or is severely calcified, that would prevent complete inflation of an angioplasty balloon. This assessment should be based on visual estimation.
  5. Target vessel had angiographic evidence of thrombus.
  6. Target lesion was totally occluded (100% stenosis).
  7. Target vessel was treated with brachytherapy any time prior to the index procedure.
Terms in these criteria, in plain language(8)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

ECG (electrocardiogram)

A recording of the heart’s electrical activity, taken with stickers on the chest, arms and legs. It takes a few minutes and does not hurt.

Clinically significant

Judged by the study doctor to matter for your health or for the study. It is a doctor’s decision, so ask the study team if you are unsure whether something counts.

TIA (transient ischaemic attack)

A “mini-stroke”: temporary stroke-like symptoms caused by reduced blood flow to part of the brain, spinal cord or eye, without signs of a new stroke on a scan.

Stroke symptoms need emergency care at once, even if they go away.

LVEF (left ventricular ejection fraction)

The share of blood the heart’s main pumping chamber (the left ventricle) pushes out with each beat, measured by an echocardiogram (heart ultrasound) or a MUGA scan. About 50–70% is normal.

Platelets

Blood cells that help blood clot. Too few raises the risk of bleeding and bruising. A usual adult range is about 150–400 × 10⁹/L (150,000–400,000 per µL); each lab has its own reference range.

Life expectancy

The study doctor’s estimate of how long someone is likely to live. Criteria use it so that people can stay in the study long enough for it to answer its question.

Investigational drug or device

A drug or device being studied in a clinical trial.

It may be new, or already approved and being studied for another use, dose or form. Criteria often leave out people who took part in another study of one within a recent period, commonly 30 days or five half-lives.

05

Study design

Observational model
Cohort
Time perspective
Prospective
Enrollment
556 participants (actual)
Patient registry
No

Groups and cohorts

  • Orsiro sirolimus coronary stent system

    Intervention with a Orsiro DES.

    Device: Orsiro DES

Interventions

  • DeviceOrsiro DES

    Orsiro is a device/drug combination product composed of two components, a device (coronary stent system including a cobalt chromium stent platform), and a drug product (a formulation of sirolimus) contained in a bioabsorbable polymer coating.

    Also known as: Orsiro sirolimus coronary stent system

06

What researchers measure

Primary outcomes

  1. Percentage of Participants With Target Lesion Failure (TLF) at 12 Months Post-Index Procedure

    TLF is defined as all cardiac death, target vessel Q-wave or non-Q-wave myocardial infarction (MI), or clinically driven target lesion revascularization (TLR).

    Time frame: 12-Months

Secondary outcomes

  1. All-cause Death

    Time frame: at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year

  2. Protocol-defined Any-vessel Myocardial Infarction

    Time frame: at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year

  3. Target Lesion Revascularization (TLR)

    Time frame: at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year

  4. Target Vessel Revascularization (TVR)

    Time frame: at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year

  5. Cardiac Death or Protocol-defined Any-vessel MI

    Time frame: at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year

  6. Target Lesion Failure (Cardiac Death, Protocol-defined Target Vessel MI, Clinically-driven TLR)

    Time frame: at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year

  7. Target Vessel Failure (Cardiac Death, Protocol-defined Target Vessel MI, Clinically-driven TVR)

    Time frame: at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year

  8. MACE (Death, Protocol-defined Any Vessel Q Wave or Non-Q Wave MI, Clinically-driven TLR

    Time frame: at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year

  9. Stent Thrombosis

    Time frame: at 24 Hours, at 1 Month, at 1 Year

  10. Number of Lesions With Device Success

    Defined as attainment of \< 30% residual stenosis of the target lesion using the assigned study stent only.

    Time frame: at Hospital Discharge an average of 1 day

  11. Number of Lesions With Lesion Success

    Defined as attainment of \< 30% residual stenosis of the target lesion using any percutaneous method.

    Time frame: at Hospital Discharge an average of 1 day

  12. Number of Participants With Procedure Success

    Defined as attainment of \< 30% residual stenosis of the target lesion using the assigned study stent only without occurrence of in-hospital major adverse cardiac events (MACE; composite of all-cause death, Q-wave or non-Q-wave MI, and any clinically-driven TLR).

    Time frame: at Hospital Discharge an average of 1 day

07

Results

Posted Apr 26, 2024

Participant flow

Participant flow — Overall Study
MilestoneOrsiro Sirolimus Coronary Stent System
Started556
Completed531
Not completed25

Outcome measures

PrimaryPercentage of Participants With Target Lesion Failure (TLF) at 12 Months Post-Index Procedure

TLF is defined as all cardiac death, target vessel Q-wave or non-Q-wave myocardial infarction (MI), or clinically driven target lesion revascularization (TLR).

Time frame:
12-Months
Reported as:
Count of participants · Participants
Percentage of Participants With Target Lesion Failure (TLF) at 12 Months Post-Index Procedure
ParticipantsOrsiro Sirolimus Coronary Stent System
Percentage of Participants With Target Lesion Failure (TLF) at 12 Months Post-Index Procedure9
Statistical analysis
  • Orsiro Sirolimus Coronary Stent System · Exact, binomial · p = <0.0001
SecondaryAll-cause Death
Time frame:
at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year
Reported as:
Count of participants · Participants
All-cause Death
ParticipantsOrsiro Sirolimus Coronary Stent System
Hospital Discharge1
1 Month2
1 Year6
SecondaryProtocol-defined Any-vessel Myocardial Infarction
Time frame:
at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year
Reported as:
Count of participants · Participants
Protocol-defined Any-vessel Myocardial Infarction
ParticipantsOrsiro Sirolimus Coronary Stent System
Hospital Discharge3
1 Month4
1 Year9
SecondaryTarget Lesion Revascularization (TLR)
Time frame:
at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year
Reported as:
Count of participants · Participants
Target Lesion Revascularization (TLR)
ParticipantsOrsiro Sirolimus Coronary Stent System
Hospital Discharge2
1 Month3
1 Year8
SecondaryTarget Vessel Revascularization (TVR)
Time frame:
at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year
Reported as:
Count of participants · Participants
Target Vessel Revascularization (TVR)
ParticipantsOrsiro Sirolimus Coronary Stent System
Hospital Discharge2
1 Month3
1 Year15
SecondaryCardiac Death or Protocol-defined Any-vessel MI
Time frame:
at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year
Reported as:
Count of participants · Participants
Cardiac Death or Protocol-defined Any-vessel MI
ParticipantsOrsiro Sirolimus Coronary Stent System
Hospital Discharge3
1 Month4
1 Year9
SecondaryTarget Lesion Failure (Cardiac Death, Protocol-defined Target Vessel MI, Clinically-driven TLR)
Time frame:
at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year
Reported as:
Count of participants · Participants
Target Lesion Failure (Cardiac Death, Protocol-defined Target Vessel MI, Clinically-driven TLR)
ParticipantsOrsiro Sirolimus Coronary Stent System
Hospital Discharge TLF Total3
Hospital Discharge TLF Component: Cardiac Death0
Hospital Discharge TLF Component: Protocol-defined Target Vessel MI3
Hospital Discharge TLF Component: Clinically-driven TLR2
1 Month TLF Total4
1 Month TLF Component: Cardiac Death0
1 Month TLF Component: Protocol-defined Target Vessel MI4
1 Month TLF Component: Clinically-driven TLR2
1 Year TLF Total9
1 Year TLF Component: Cardiac Death0
1 Year TLF Component: Protocol-defined Target Vessel MI7
1 Year TLF Component: Clinically-driven TLR5
SecondaryTarget Vessel Failure (Cardiac Death, Protocol-defined Target Vessel MI, Clinically-driven TVR)
Time frame:
at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year
Reported as:
Count of participants · Participants
Target Vessel Failure (Cardiac Death, Protocol-defined Target Vessel MI, Clinically-driven TVR)
ParticipantsOrsiro Sirolimus Coronary Stent System
Hospital Discharge TVF Total3
Hospital Discharge TVF Component: Cardiac Death0
Hospital Discharge TVF Component: Protocol-defined Target Vessel MI3
Hospital Discharge TVF Component: Clinically-driven TVR2
1 Month TVF Total4
1 Month TVF Component: Cardiac Death0
1 Month TVF Component: Protocol-defined Target Vessel MI4
1 Month TVF Component: Clinically-driven TVR2
1 Year TVF Total14
1 Year TVF Component: Cardiac Death0
1 Year TVF Component: Protocol-defined Target Vessel MI7
1 Year TVF Component: Clinically-driven TVR12
SecondaryMACE (Death, Protocol-defined Any Vessel Q Wave or Non-Q Wave MI, Clinically-driven TLR
Time frame:
at Hospital Discharge an average of 1 day, at 1 Month, at 1 Year
Reported as:
Count of participants · Participants
MACE (Death, Protocol-defined Any Vessel Q Wave or Non-Q Wave MI, Clinically-driven TLR
ParticipantsOrsiro Sirolimus Coronary Stent System
Hospital Discharge MACE Total4
Hospital Discharge MACE Component: Death1
Hospital Discharge MACE Component: Protocol-defined Any-Vessel Q Wave or Non-Q Wave MI3
Hospital Discharge MACE Component: Clinically-driven TLR2
1 Month MACE Total6
1 Month MACE Component: Death2
1 Month MACE Component: Protocol-defined Any-Vessel Q Wave or Non-Q Wave MI4
1 Month MACE Component: Clinically-driven TLR2
1 Year MACE Total17
1 Year MACE Component: Death6
1 Year MACE Component: Protocol-defined Any-Vessel Q Wave or Non-Q Wave MI9
1 Year MACE Component: Clinically-driven TLR5
SecondaryStent Thrombosis
Time frame:
at 24 Hours, at 1 Month, at 1 Year
Reported as:
Count of participants · Participants
Stent Thrombosis
ParticipantsOrsiro Sirolimus Coronary Stent System
Any ARC-2 Stent Thrombosis Acute (<=24 hours)1
Any ARC-2 Stent Thrombosis Sub-acute (>24 hours and <=30 days)0
Any ARC-2 Stent Thrombosis Late (>30 days and <=1 year)1
Definite ARC-2 Stent Thrombosis Acute (<=24 hours)1
Definite ARC-2 Stent Thrombosis Sub-acute (>24 hours and <=30 days)0
Definite ARC-2 Stent Thrombosis Late (>30 days and <=1 year)1
Probable ARC-2 Stent Thrombosis Acute (<=24 hours)0
Probable ARC-2 Stent Thrombosis Sub-acute (>24 hours and <=30 days)0
Probable ARC-2 Stent Thrombosis Late (>30 days and <=1 year)0
SecondaryNumber of Lesions With Device Success

Defined as attainment of \< 30% residual stenosis of the target lesion using the assigned study stent only.

Time frame:
at Hospital Discharge an average of 1 day
Reported as:
Number · Lesions
Number of Lesions With Device Success
LesionsOrsiro Sirolimus Coronary Stent System
Number of Lesions With Device Success689
SecondaryNumber of Lesions With Lesion Success

Defined as attainment of \< 30% residual stenosis of the target lesion using any percutaneous method.

Time frame:
at Hospital Discharge an average of 1 day
Reported as:
Number · Lesions
Number of Lesions With Lesion Success
LesionsOrsiro Sirolimus Coronary Stent System
Number of Lesions With Lesion Success689
SecondaryNumber of Participants With Procedure Success

Defined as attainment of \< 30% residual stenosis of the target lesion using the assigned study stent only without occurrence of in-hospital major adverse cardiac events (MACE; composite of all-cause death, Q-wave or non-Q-wave MI, and any clinically-driven TLR).

Time frame:
at Hospital Discharge an average of 1 day
Reported as:
Count of participants · Participants
Number of Participants With Procedure Success
ParticipantsOrsiro Sirolimus Coronary Stent System
Number of Participants With Procedure Success551

Adverse events

Collected over 1 Year. Non-serious events are listed at a 1% frequency threshold.

Adverse event summary by group
GroupDeathsSeriousOther
Orsiro Sirolimus Coronary Stent System6/556 (1.1%)154/556 (27.7%)58/556 (10.4%)
Most frequent serious events
Showing 10 of 121
Most frequent serious events
EventOrsiro Sirolimus Coronary Stent System
Chest painGeneral disorders24/556
Coronary artery stenosisCardiac disorders17/556
Atrial fibrillationCardiac disorders8/556
Acute myocardial infarctionCardiac disorders7/556
COVID-19 pneumoniaInfections and infestations7/556
Angina unstableCardiac disorders6/556
Cardiac failure congestiveCardiac disorders6/556
Urinary tract infectionInfections and infestations6/556
Angina pectorisCardiac disorders5/556
Coronary artery dissectionCardiac disorders5/556
Most frequent other events
Most frequent other events
EventOrsiro Sirolimus Coronary Stent System
Myocardial necrosis marker increasedInvestigations34/556
Chest painGeneral disorders16/556
Catheter site haematomaGeneral disorders8/556

Baseline characteristics

Age, Continuous
Age, Continuous(years)Orsiro Sirolimus Coronary Stent System
Mean65.2 ± 10.6
Sex: Female, Male
Sex: Female, Male(Participants)Orsiro Sirolimus Coronary Stent System
Female193
Male363
Ethnicity (NIH/OMB)
Ethnicity (NIH/OMB)(Participants)Orsiro Sirolimus Coronary Stent System
Hispanic or Latino31
Not Hispanic or Latino513
Unknown or Not Reported12
Race (NIH/OMB)
Race (NIH/OMB)(Participants)Orsiro Sirolimus Coronary Stent System
American Indian or Alaska Native1
Asian9
Native Hawaiian or Other Pacific Islander0
Black or African American51
White452
More than one race0
Unknown or Not Reported43
08

Study locations

33 sites
  • Cardiology Associates of Mobile
    Fairhope, Alabama 36532, United States
  • John Muir Medical Center
    Concord, California 94520, United States
  • St. Joseph Hospital Orange
    Orange, California 92868, United States
  • MedStar Washington Hospital Center
    Washington D.C., District of Columbia 20010, United States
  • AdventHealth Tampa
    Tampa, Florida 33613, United States
  • Piedmont Heart Institute
    Atlanta, Georgia 30309, United States
  • University of Illinois
    Chicago, Illinois 60612, United States
  • University of Chicago Medical Center
    Chicago, Illinois 60637, United States
  • Advocate Lutheran General Hospital
    Park Ridge, Illinois 60068, United States
  • Ascension St. Vincent Medical Group
    Indianapolis, Indiana 46920, United States
  • Ascension Via Christi Hospitals
    Wichita, Kansas 67226, United States
  • University of Kentucky
    Lexington, Kentucky 40536, United States
  • Northern Light Cardiology
    Bangor, Maine 04401, United States
  • MedStar Union Memorial Hospital
    Baltimore, Maryland 21218, United States
  • Massachusetts General Hospital
    Boston, Massachusetts 02114, United States
  • Brigham and Women's Hospital
    Boston, Massachusetts 02115, United States
  • Baystate Medical Center
    Springfield, Massachusetts 01199, United States
  • University of Michigan Medical Center
    Ann Arbor, Michigan 48109, United States
  • Minneapolis Heart Institute
    Minneapolis, Minnesota 55407, United States
  • Saint Michael's Medical Center
    Newark, New Jersey 07102, United States
  • Maimonides Medical Center
    Brooklyn, New York 11219, United States
  • Columbia University Medical Center
    New York, New York 10032, United States
  • Weill Cornell Medical College
    New York, New York 10065, United States
  • Mercy Health - St Vincent Medical Center
    Toledo, Ohio 43608, United States
  • Penn State Health Holy Spirit Medical Center
    Camp Hill, Pennsylvania 17011, United States
  • AnMed Health
    Anderson, South Carolina 29621, United States
  • Vanderbilt University Medical Center
    Nashville, Tennessee 37232, United States
  • Seton Medical Center Austin
    Austin, Texas 78705, United States
  • Austin Heart
    Austin, Texas 78756, United States
  • Baylor Heart and Vascular Hospital
    Dallas, Texas 75226, United States
  • UT Health Science Center
    Houston, Texas 77030, United States
  • University of Virginia Health System
    Charlottesville, Virginia 22908, United States
  • Charleston Area Medical Center Memorial Hospital
    Charleston, West Virginia 25304, United States
09

References and documents

Study documents

PDFs hosted by the registry, ClinicalTrials.gov.

Individual participant data

Plan to share: Yes — Applicable de-identified individual participant data will be made available to achieve aims in approved proposals, including but not limited to sub-analysis or meta-analysis.

Supporting information: Study protocol, Statistical analysis plan, Informed consent form, Clinical study report

Time frame: Beginning no later than 12 months and ending no earlier than 3 years following initial publication of clinical study results.

Access criteria: Researchers who provide a methodologically sound proposal for analysis that is not pre-planned or already approved with another researcher. Proposals must be approved by BIOTRONIK and Study Principal Investigator. Proposals should be directed to BIOTRONIK Clinical Studies (BIOTRONIK Inc., Attn: Clinical Studies, 6024 Jean Road, Lake Oswego, OR 97035; 1-800-547-0394). To gain access, data requesters will need to sign a data use/access agreement.

10

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Ran from Jan 2020 to primary completion in Jan 2022, 23 months.

Results were first posted in Apr 2024, 2 years 3 months after primary completion.

Of 125 industry-sponsored observational studies under Coronary Artery Disease, half reached primary completion within 27 months of starting (the median), counting those still running; a quarter within 15 and three quarters within 40. This study's 23 months is below that.

Counting every sponsor, half of 763 studies reached it within 41 months; a quarter within 21 and three quarters within 87.

How these figures are worked out, and which studies are left out of them.

Registered
Nov 21, 2019
First posted
Nov 25, 2019
StartActual
Jan 24, 2020
Primary completionActual
Jan 12, 2022
CompletionActual
Jan 8, 2026
Results first posted
Apr 26, 2024
Last update
Feb 27, 2026
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Feb 27, 2026, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
11

Registry details

Key details

Study ID
NCT04175626
Lead sponsor
Biotronik, Inc.
Responsible party
Sponsor
First posted
Nov 25, 2019
Start date
Jan 24, 2020
Primary completion
Jan 12, 2022
Completion
Jan 8, 2026
Results posted
Apr 26, 2024
Last update
Feb 27, 2026

Study contacts

David Kandzari, MD
principal investigator · Piedmont Heart Institute

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Feb 2026. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion