CClinicalTrials.gg
CompletedNCT03303807COVAPUpdated Jul 5, 2019

Correction by ECCO2-R of Hypercapnia in Patients With DVP in Moderate to Severe ARDS Under Protective Ventilation.

An interventional study of Extracorporeal CO2 removal (ECCO2-R) (PrismaLung®, Prismaflex ® Baxter) in Acute Respiratory Distress Syndrome and Hypercapnia, sponsored by Assistance Publique - Hôpitaux de Paris. Completed at 1 site in France. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2019-07-05.

Sponsored by Assistance Publique - Hôpitaux de Paris · Not applicable, Interventional, and Prevention

Phase
Not applicable
Study type
Interventional
Enrollment
8
Allocation
Not applicable
Ages
18 Years and older
Sex
All
01

Study summary

Pulmonary vascular dysfunction (DVP) is associated with a pejorative prognosis during ARDS. There is no specific therapeutic intervention to thwart it. Extracorporeal CO2 purification (ECCO2-R) is a technique that has been very rapidly diffused and adopted in intensive care since commercialization of the devices but, the formal clinical evaluation is insufficient. It could significantly improve the prognosis of patients with both DVP and refractory hypercapnia.

Read the detailed description

This is a prospective, non-comparative, open-label, multicenter regional study, without random drawing or blindfolding.

The primary objective of the study is the correction by ECCO2-R of hypercapnia in patients with DVP in moderate to severe ARDS under protective ventilation.

The primary endpoint is the percentage of patients with hypercapnia correction (defined as a 20% decrease in PaCO2 at H2 of ECCO2-R initiation).

The secondary objectives are:

  • Demonstrate that ECCO2-R allows in hypercapnic ARDS and DVP patients to correct hypercapnia with H6 and H24, improve DVP and hemodynamics, reduce alveolar dead space, improvement of respiratory mechanics
  • Assess the tolerance of the evaluated technique.

The Secondary endpoints are:

  • Relative change of capnia to H6 and H24 in relation to H0; proportion of patients with a decrease of at least 20% of PaCO2 to H6 and H24; changes in echocardiographic indices; hemodynamic parameters; alveolar deadspace and respiratory mechanics to H2, H6 and H24, compared to H0; Complications, Mortality at reanimation discharge (or on D28 if this date occurs before discharge of reanimation).

The intervention is based on the use of ECCO2-R (PrismaLung®, Prismaflex ® Baxter) in eligible patients. ECCO2-R will be initiated as soon as possible after inclusion, for a duration of at least 24 H (possibly prolonged up to 72 H at the decision of reanimator), by jugular or femoral vein-venous.

The size of the catheters, the machine settings, in particular the blood flow and sweep will be standardized according to the state of the art and the recommendations of the manufacturer

The ECO2R venous technique uses devices consisting of a monitor, an exchanger and a pump.

  1. The PrismaLung® Kit (Baxter): Single-use EC-marked extracorporeal circuit intended for use for at least 24 hours (maximum 72 hours).

    The PrismaLung® kit is intended for use with the Prismaflex® monitor with software version 8.10 or later and its support in conjunction with Prismaflex® single use treatment sets.

  2. The Prismaflex HP-X Set (Baxter): blood line set for extracorporeal blood circulation, EC marked or the HF 1400® set (Baxter) (for extra-corporeal CO2 purification combined with purification).
  3. The Prismaflex® monitor (Baxter), EC marked, is used routinely in intensive care (continuous extra-renal purification, therapeutic plasma exchange, haemoperfusion, hemopurification).

So that each center has a dedicated monitor for research, this device will be provided by the Baxter laboratory. The monitor will be equipped with a holder for the Prismalung kit marked CE.

02

Conditions studied

  • Acute Respiratory Distress Syndrome
  • Hypercapnia

Keywords

  • Extracorporeal CO2 removal (ECCO2-R)
  • ARDS
03

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Inclusion criteria

  • Moderate to severe ARDS according to the Berlin definition;
  • Pulmonary vascular dysfunction at echocardiography (pulmonary arterial hypertension, right ventricular dilatation or dyskinesia of the interventricular septum);
  • Refractory hypercapnia, defined by a PaCO2 ≥48 mmHg in spite of the reduction of the instrumental dead space and the increase of the respiratory rate.
  • Free and informed written consent for persons in a position to consent; consent of the support person/parent/relative in case of incapacity to consent; inclusion in emergency situations (Article L1122-1-2 of the CSP)

Exclusion criteria

Exclusion Criteria:

  • Age \<18 years;
  • Known pregnancy or breastfeeding;
  • Contra-indication to curative anticoagulation, thrombocytopenia \<50 G / L, heparin-induced thrombocytopenia, known hypersensitivity to heparin or to compounds;
  • Femoral or jugular venous access impossible;
  • Refractory hypoxemia with indication at ECMO;
  • No affiliation to social security or beneficiary
04

Study design

Phase
Not applicable
Primary purpose
Prevention
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
8 participants (actual)

Study arms

  • Other
    Extracorporeal CO2 removal

    Extracorporeal CO2 removal (ECCO2-R) (PrismaLung®, Prismaflex ® Baxter)

    Device: Extracorporeal CO2 removal (ECCO2-R) (PrismaLung®, Prismaflex ® Baxter)

Interventions

  • DeviceExtracorporeal CO2 removal (ECCO2-R) (PrismaLung®, Prismaflex ® Baxter)

    A low-flow CO2 removal device (Prismalung®, Baxter) will be used with a conventional renal replacement therapy (RRT) platform (Prismaflex®, Baxter). In patients already treated with continuous RRT because of renal failure or metabolic acidosis, the HF 1400® (Baxter) set will be used to combine RRT and decarboxylation. Gas flow through the gas exchanger will be set up to 10 L/min, with an oxygen concentration from 0.21 to 1 and a blood flow of 200-400 mL/min. Patients will be ventilated with a target tidal volume of 6 ml/kg (predicted body weight) and a target plateau pressure below 30 cmH2O.

05

What researchers measure

Primary outcomes

  1. Percentage of patients with corrected hypercapnia

    20% decrease in PaCO2 two hours after ECCO2-R initiation

    Time frame: at hour 2 (H2)

Secondary outcomes

  1. Relative change of capnia at H6 and H24 after ECCO2-R

    Time frame: at hour 6 (H6), at hour 24 (H24)

  2. Proportion of patients with a decrease of at least 20% of PaCO2 to H6 and H24

    Time frame: H6, H24

  3. Changes in echocardiographic indices

    Changes in echocardiographic indices at H2, H6 and H24

    Time frame: H2, H6, H24

  4. Changes in hemodynamic parameters

    Changes in hemodynamic parameters at H2, H6 and H24

    Time frame: H2, H6, H24

  5. Changes in alveolar deadspace

    Changes in alveolar deadspace at H2, H6 and H24

    Time frame: H2, H6, H24

  6. Changes in respiratory mechanics

    Changes in respiratory mechanics at H2, H6 and H24

    Time frame: H2, H6, H24

  7. Number of complications related to ECCO2-R technique

    Time frame: ICU Discharge or day 28

  8. Percentage of mortality

    Time frame: ICU discharge or day 28

06

Study locations

1 site
  • Henri Mondor Hospital
    Creteil, 94000, France
07

Registry details

Key details

Study ID
NCT03303807
Lead sponsor
Assistance Publique - Hôpitaux de Paris
Responsible party
Sponsor
First posted
Oct 6, 2017
Start date
Jan 10, 2018
Primary completion
Feb 25, 2019
Completion
Mar 21, 2019
Last update
Jul 5, 2019

Study contacts

Armand Mekontso Dessap, MD, PhD
study chair · Assistance Publique - Hôpitaux de Paris

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Sep 2018. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion