A Phase 2 interventional study of AmM MAGNITUDE Bioresorbable Drug-Eluting Coronary Scaffold in Coronary Artery Disease and Myocardial Ischemia, sponsored by Amaranth Medical Inc.. Status unknown at 13 sites in 2 countries. Open to participants aged 18 Years to 84 Years. Per ClinicalTrials.gov, last updated 2016-11-25.
Sponsored by Amaranth Medical Inc. · Phase 2, Interventional, and Treatment
The purpose of this study is to evaluate the safety and performance of a new version of a coronary artery stent for treating blockages in the arteries supplying blood to the heart muscle. The Amaranth Medical MAGNITUDE scaffold releases a drug (sirolimus) to reduce the likelihood of the treated blood vessel developing a new blockage. In addition, the scaffold dissolves away over time, leaving no permanent implant after the blood vessel has healed.
The objective of this study is to evaluate the safety and performance of the AmM MAGNITUDE Bioresorbable Drug-Eluting Coronary Scaffold for use in the treatment of up to two different de novo native coronary artery lesions in patients undergoing elective percutaneous coronary intervention. The scaffold is a single-use device comprised of a balloon-expandable, intracoronary drug coated scaffold pre-mounted on a rapid-exchange delivery catheter. The scaffold is made of Poly-L-Lactide (PLLA) and is coated with a polymer-antiproliferative drug (sirolimus) matrix. The scaffold provides mechanical support similar to a metallic stent to the vessel while it is healing, and then gradually breaks down over time leaving no permanent implant in the treated vessel. Compared to prior versions of the scaffold, the new device has a thinner strut design (a wall thickness of 100 µm rather than 120 µm or 150 µm), but is otherwise identical.
The study design is a prospective, non-randomized, multi-center, non-inferiority trial. It will enroll a maximum of 70 patients from up to 20 investigational centers in Colombia and the European Union. Eligible patients who are at least 18 years of age diagnosed with symptomatic ischemic disease due to up to two different, de novo, stenotic lesions in native coronary arteries will be asked to participate in this study. After treatment with the investigational device, subjects will be followed for five years. Safety of the device will be evaluated using the incidence of target vessel failure during the follow-up period. Performance (efficacy) will be assessed using the in-scaffold late lumen loss measured by quantitative coronary angiography at nine months.
5,677 studies on the registry are indexed under Coronary Artery Disease; 958 are open to participants now.
This study's planned enrollment of 70 is below the median of 123 across 3,481 interventional studies indexed under Coronary Artery Disease.
Browse Coronary Artery Disease studies →Amaranth Medical Inc. is the lead sponsor of 4 studies on the registry; none are open to participants now.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
General
Subject has:
Angiographic
If an elective percutaneous intervention for two different lesions is planned, one of the following situations must apply:
If one lesion is intended to be treated with a litmus-based metallic DES and the second lesion is a study lesion (e.g., suitable for stenting with the MAGNITUDE™ scaffold), the two lesions must be located in two different epicardial vessels (side branches are considered separate vessels). Both lesions can be treated during the same procedure. In case a staging strategy is chosen, no minimum period between the staged interventions is required. However, all of the following conditions must apply:
Exclusion Criteria:
General
Angiographic Exclusion
A study lesion (e.g., suitable for stenting with the MAGNITUDE™ scaffold) meets any of the following criteria:
AmM MAGNITUDE Bioresorbable Drug-Eluting Coronary Scaffold
Device: AmM MAGNITUDE Bioresorbable Drug-Eluting Coronary Scaffold
Placement of the investigational device into the diseased coronary artery to eliminate the vascular stenosis.
Also known as: Coronary stent
In-scaffold late lumen loss
Defined as the amount of vessel lumen diameter (in mm) lost/gained at the time of follow-up compared to the immediate post-treatment result, as measured by quantitative coronary angiography (QCA). The assessment is made within the segment of vessel containing the scaffold.
Time frame: 9 months
Incidence of target vessel failure
Defined as the composite rate of cardiac death (using the Academic Research Consortium \[ARC\] definition), target vessel myocardial infarction (using the Expert Consensus Document from the Society for Cardiovascular Angiography and Interventions), or clinically indicated target lesion revascularization (using the ARC definition).
Time frame: 9 months
Clinical device success
Defined as successful delivery and deployment of the investigational scaffold at the intended target lesion with attainment of a final residual stenosis of \< 50% of the target lesion by quantitative coronary angiography (QCA) after the index procedure; calculated on a per lesion basis.
Time frame: intraoperative
Clinical procedure success
Defined as successful delivery and deployment of the investigational scaffold at the intended target lesion(s), with attainment of a final residual stenosis of \< 50% of the target lesion by quantitative coronary angiography (QCA) using any adjunctive device, without the occurrence of major adverse clinical events (cardiac death, target vessel myocardial infarction, or clinically indicated target lesion revascularization) during the duration of the subject's hospital stay (an average of 1-2 days); calculated on a per patient basis.
Time frame: Participants will be followed for the duration of their hospital stay, an expected average of 1-2 days
Vessel patency
Assessed both by the minimum lumen diameter (MLD) and percent diameter stenosis (%DS), each measured at 2 years by either coronary computed tomography angiography (CTA) or quantitative coronary angiography (QCA).
Time frame: 2 years
In-segment late lumen loss
Defined as the amount of vessel lumen diameter (in mm) lost/gained at the time of follow-up compared to the immediate post-treatment result, as measured by quantitative coronary angiography (QCA). The assessment is made within the segment of vessel including the scaffold and 5 mm proximal and distal to the scaffold.
Time frame: 9 months
In-scaffold and in-segment binary restenosis rate
Defined as the percentage of treated coronary lesions with a residual diameter stenosis \> 50% at the time of follow-up, as measured by quantitative coronary angiography (QCA) or coronary computed tomography angiography (CTA). The assessments are made both within the scaffold itself ("in-scaffold") and within the segment of vessel including the scaffold and 5 mm proximal and distal to the scaffold ("in-segment").
Time frame: 9 months and 2 years
In-scaffold percent volume obstruction
Defined as the difference between the volume enclosed within the scaffold and the corresponding vessel lumen, expressed as a percentage of the scaffold volume at the time of follow-up, measured using optical coherence tomography (OCT).
Time frame: 9 months
Incomplete scaffold strut apposition to the vessel wall
Defined as the number (or percentage) of scaffold struts not in direct contact with the vessel wall, either persisting from the implantation of the scaffold or newly occurring after the time of scaffold implantation, assessed at follow-up using optical coherence tomography (OCT).
Time frame: 9 months
Stent Thrombosis
Defined using the Academic Research Consortium (ARC) "definite" or "probable" stent thrombosis definitions.
Time frame: Hospital discharge, 30 days, 9 months, and 2 years
Minimal Lumen Area
Measured by quantitative coronary angiography (QCA) or coronary computed tomography angiography (CTA).
Time frame: 2 years
Minimal Lumen Diameter
Measured by quantitative coronary angiography (QCA) or coronary computed tomography angiography (CTA).
Time frame: 2 years
Mean Area Stenosis
Measured by quantitative coronary angiography (QCA) or coronary computed tomography angiography (CTA).
Time frame: 2 years
Incidence of target vessel failure
Defined as the composite rate of cardiac death (using the Academic Research Consortium \[ARC\] definition), target vessel myocardial infarction (using the Expert Consensus Document from the Society for Cardiovascular Angiography and Interventions), or clinically indicated target lesion revascularization (using the ARC definition).
Time frame: 30 days and 2 years
Vascular complications
Vascular access site complications, including hematoma, retroperitoneal hemorrhage, pseudoaneurysm, arteriovenous fistula, dissection, and thrombosis/embolism.
Time frame: Participants will be followed for the duration of their hospital stay, an expected average of 1-2 days
Plan to share: Undecided
The record gives a start of Oct 2016, a primary completion of Mar 2018 and a completion of Jun 2022. It does not say whether these dates are actual or estimated.
How these figures are worked out, and which studies are left out of them.
This study is status unknown, as verified in Nov 2016. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Amaranth Medical Inc.