An interventional study of Custom-Made Titanium Plate and Custom-Made PEEK Plate in Mandibular Fractures, sponsored by Mansoura University. Recruiting at 1 site in Egypt. Open to participants aged 18 Years to 50 Years. Per ClinicalTrials.gov, last updated 2026-10-09.
Sponsored by Mansoura University · Not applicable, Interventional, and Treatment
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 42 studies in Mandibular Fractures with a site in Egypt — 8 open to participants now, 11 under way, none of them phase 3. Mandibular Fractures · Egypt.
Among the 42 studies in Mandibular Fractures with a site in Egypt, this one is the 3rd largest by planned enrollment of the 38 interventional ones that give a count, is one of 5 that started in 2026, is one of 35 with no phase, reaches primary completion later than 8 of the 10 other live ones, and was the 40th registered.
91 studies on the registry are indexed under Mandibular Fractures; 24 are open to participants now.
Browse Mandibular Fractures studies →8 of the 42 studies in Mandibular Fractures with a site in Egypt are open now. Recruiting first, the newest first:
Cairo University · Sites in Egypt
Ages 6–12
Cairo University · Sites in Egypt
Ages 18–55
Delta University for Science and Technology · Sites in Egypt
Ages 20–45 · Healthy volunteers
Suez Canal University · Sites in Egypt
Ages 18–50
Mansoura University · Sites in Egypt
Ages 18–50
A study can be open while its sites in Egypt have not opened yet or have stopped. Only those recruiting at a site in Egypt →
Of the 11 Mandibular Fractures studies recruiting now, 2 (18%) set no upper age limit and 9 (82%) stop at 75 or younger; 1 takes children under 18; 2 take healthy volunteers.
This study: 18 Years to 50 Years · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
42 studies; the count open now beside each. This study's row is marked.
First in 2016; this study’s year is marked. 5 started in 2026.
This study's planned enrollment of 32 is above the median of 21 across 72 interventional studies indexed under Mandibular Fractures.
Median enrollment 20 across the 38 interventional studies, 43 across the 4 observational. Of the 24 that completed or were terminated, 0 (0%) have results posted.
This tab as a report to print or save as PDF → With an account.
None of the 42 has an industry lead sponsor. The 10 most frequent:
Mansoura University is the lead sponsor of 1,122 studies on the registry; 184 are open to participants now.
Of its 9 completed or terminated interventional studies of FDA-regulated products, 0 (0%) have results posted.
Mansoura University has 4 studies filed under Mandibular Fractures — fewer than ten, so there is no comparison to draw.
6 of the studies in Mandibular Fractures with a site in Egypt that are under way reach primary completion within a year, 0 of them phase 3. Phase 3 first, then by date:
| Study | Primary completion |
|---|---|
| NCT07807813Delta University for Science and TechnologySafety-zone Approach and Facial Nerve Preservation in Transbuccal-accessed Fixation of Mandibular Fractures | 2026-11 |
| NCT07263893Suez Canal UniversityInter Flex Three Dimensional Plate in Management of Mandibular Fracture RCT | 2026-12-01 |
| NCT07153120Mansoura UniversityErich Arch Bars, IMF Screws and Hybrid Arch Bars in the Management of Mandibular Fractures | 2027-02 |
| NCT07850570Mansoura UniversityCustom-Made Titanium Plates Versus Custom-Made Polyether Ether Ketone (PEEK) Plates | 2027-03-24 |
| NCT07515937Cairo UniversityOcclusal Assessment of Pediatric Mandibular Fractures Managed by 3D-Printed Acrylic Occlusal Cap Splint: A Case Series | 2027-07 |
Add all 6 to your calendar (.ics) → With an account.
Among the 42 studies in Mandibular Fractures with a site in Egypt, from their registry updates:
This tab as a report to print or save as PDF → With an account.
Mandibular fractures represent a significant portion of maxillofacial trauma, primarily resulting from motor vehicle accidents, interpersonal violence, and sports-related injuries. Achieving successful treatment requires accurate anatomical reduction, stable internal fixation, and restoration of pre-traumatic occlusion and masticatory function . Open reduction and internal fixation (ORIF) using titanium miniplates has long served as the gold standard for mandibular fracture management due to their superior mechanical strength, excellent biocompatibility, and proven structural reliability .
Despite their widespread clinical adoption, conventional titanium plates present notable drawbacks. Their high elastic modulus compared to human cortical bone often leads to stress shielding, which can impede normal bone healing and cause local osteopenia .Additionally, titanium hardware can cause temperature sensitivity, scatter artifacts on computed tomography (CT) and magnetic resonance imaging (MRI) scans, and may necessitate secondary surgical removal due to palpability or infection .
To address these limitations, Polyether Ether Ketone (PEEK)-a high-performance thermoplastic polymer has emerged as a promising alternative biomaterial in maxillofacial surgery. PEEK exhibits an elastic modulus close to natural bone, thereby reducing stress shielding and promoting physiological strain distribution during fracture healing. Furthermore, PEEK is radiolucent, non-magnetic, and chemically inert, allowing artifact-free postoperative radiologic assessment .
With advancements in digital dentistry, computer-aided design and computer-aided manufacturing (CAD/CAM) alongside 3D printing have enabled the fabrication of patient-specific, custom-made implants. Custom-made titanium and PEEK plates eliminate the need for intraoperative manual bending, significantly reducing surgical time, improving contour accuracy, and enhancing mechanical stability across the fracture site . While custom-made titanium provides rigid fixation suitable for high-load zones, custom-made PEEK implants offer an biomechanically compatible and artifact-free alternative.
However, direct comparative clinical and biomechanical evaluations between custom-made titanium and custom-made PEEK plates for mandibular fracture fixation remain limited. Therefore, this study aimed to evaluate and compare the clinical outcome, stability, and surgical efficiency of custom-made titanium versus custom-made PEEK plates in the fixation of mandibular fractures.
Maxillofacial trauma is the most common cause of facial injuries resulting from various causes such as road traffic accidents, accidental falls, assaults, industrial mishaps, sports injuries and firearm injuries. The severity and pattern of maxillofacial trauma depend on the anatomic site, magnitude, and the direction of the force delivered to the face.
Reconstruction of facial bones following traumatic events represents one of the greatest challenges to maxillofacial surgeons. The role of the mandible is crucial in maintaining facial esthetics and functional occlusion. Due to its prominence and mobility, mandibular fractures represent the most common facial fractures, accounting for approximately 59% of all maxillofacial fractures.
Treatment modalities for mandibular fractures include closed reduction with intermaxillary fixation, open reduction with wire osteosynthesis and open reduction with rigid fixation. With modern surgical advances, modalities for the treatment of mandibular fracture depending on scientific facilities have been directed to facilitate the need of early, preferably and immediate mobilization in order to reduce the need of maxillomandibular fixation (MMF).
Whereas MMF is to blame for impairing the oral hygiene, masticatory efficiency and mouth opening besides it causes pain, phonetic disturbance and weight loss. Mandibular fractures are ideally treated with open reduction and internal fixation by an intraoral or extraoral approach. Direct bone contact between the fracture segments supports primary bone healing, that results in earlier bone regrowth and stability across the fracture site.
Nowadays, computers are being extensively used not only for diagnosis but also for designing surgical procedures in the craniomaxillofacial field. Advances in virtual surgery, 3D printing and milling techniques have significantly increased surgical precision and efficiency. These advances can be utilized alongside digital imaging techniques like computerized tomography (CT) to generate custom-made plates specifically tailored for each fracture. This can serve to shorten the operation time, eliminate the need to remove the plates and improve fixation system stability. The possibility of generating a three-dimensional model from CT scans was first mentioned in 19870.
Many materials can be employed in the process of manufacturing these custom-made plates like titanium, which is the most common conventional used type and Polyether ether ketone (PEEK) being a recent alternative.
PEEK is a linear semi-crystalline poly-aromatic polymer which has dimensional properties close to that of living bone in terms of strength and stiffness. The major beneficial property of PEEK is its lower Young's modulus of elasticity which is close to that of the cortical bone and therefore, it is likely to eliminate the major problem encountered with titanium plating system which is the stress shielding phenomenon. It is highly durable, resists a high degree of temperature greater than 300 degrees Celsius and can be used without adverse tissue effects. This study aims to evaluate the use of custom-made titanium plates versus PEEK plates in the treatment of mandibular fractures.
The null hypothesis states that there is no significant difference in clinical and radiographic outcomes between custom-made titanium plates and custom-made PEEK plates for fixation of mandibular fractures.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
The anaesthetists’ scale of health before surgery: I is healthy, II has a mild illness that is under control, III a severe one, IV a severe illness that is a constant threat to life. V and VI are used for the critically ill and for organ donors.
ASA physical status
The anaesthetists’ scale of health before surgery: I is healthy, II has a mild illness that is under control, III a severe one, IV a severe illness that is a constant threat to life. V and VI are used for the critically ill and for organ donors.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Custom-Made Titanium Plate for Fixation of Mandibular Fractures
Device: Custom-Made Titanium Plate
Custom-made polyether ether ketone (PEEK) plate used for fixation of mandibular fractures.
Device: Custom-Made PEEK Plate
Custom-made titanium plate used for fixation of mandibular fractures.
Custom-made polyether ether ketone (PEEK) plate used for fixation of mandibular fractures.
number of patients with adequate reduction of the fractured segment
will be determined by an assessment of the inferior border of the mandible as follows: 1. Excellent reduction: whenever alignment of the inferior border of mandible will be maintained across the fracture line. 2. Good reduction: if a discrepancy of 1-3 mm is noted. 3. Fair reduction: if a discrepancy of 3-5mm is noted. 4. Poor reduction: if the discrepancy is \> 5 mm.
Time frame: immediately and 6 months after the surgery consequently
Plan to share: No
No publications or documents are linked to this record.
Start is estimated for Sep 2026; primary completion for Mar 2027, 6 months later.
Of 38 non-industry interventional studies with no phase under Mandibular Fractures, half reached primary completion within 13 months of starting (the median), counting those still running; a quarter within 9 and three quarters within 24. This study's planned 6 months is below that.
Counting every sponsor, half of 38 studies reached it within 13 months; a quarter within 9 and three quarters within 24.
How these figures are worked out, and which studies are left out of them.
From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗
Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.
Contact study teamGet an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.