ClinicalTrials.gg
CompletedNCT07689838Updated Nov 4, 2026Results posted

In-Vivo Diagnostic Accuracy and Repeatability of Root ZX3 for Working-Length Determination in Single-Rooted Teeth: Agreement With CBCT and Microscopic Validation

An interventional study of Root ZX3 Electronic Apex Locator in Apical Periodontitis, Pulp Disease, Dental and Device Reliability, sponsored by Riyadh Elm University. Completed at 1 site in Saudi Arabia. Open to participants aged 18 Years and older, including healthy volunteers. Per ClinicalTrials.gov, last updated 2026-11-04.

Sponsored by Riyadh Elm University · Not applicable, Interventional, and Diagnostic

How we know

From the registry’s dates

  • Registered 8 months after the study started (first participant enrolled Oct 2025, registered Jul 2026).
Updated Nov 4, 2026Results postedStudy documents posted+3 moreGo to Updates ↓

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Phase
Not applicable
Study type
Interventional
Enrollment
41
Allocation
Not applicable
Ages
18 Years and older
Sex
All
01

Study summary

This study evaluated the accuracy and repeatability of the Root ZX3 electronic apex locator for working-length determination in 77 single-rooted permanent teeth. Root ZX3 measurements obtained before extraction were compared with CBCT measurements and direct microscopic measurements of the apical foramen after extraction.

Read the detailed description

This prospective in vivo-ex vivo study assessed Root ZX3 working-length determination in single-rooted permanent teeth. Seventy-seven teeth from adults undergoing clinically indicated extraction were included.

Root ZX3 measurements were obtained before extraction by a calibrated endodontist. After extraction, the teeth were evaluated using CBCT and direct microscopic visualization of the apical foramen. The microscopic measurement served as the reference standard. CBCT measurements were performed independently by two calibrated endodontists, with the secondary examiner assessing a subset of 20 teeth.

Root ZX3 accuracy was assessed by comparing its measurements with the microscopic reference standard, including the proportions within ±0.5 mm and ±1.0 mm. Repeatability of Root ZX3 measurements, agreement between Root ZX3 and CBCT, CBCT interobserver agreement, and differences according to clinical status were also evaluated.

Statistical analyses included McNemar's test, Bland-Altman analysis, Lin's concordance correlation coefficient, intraclass correlation coefficients, and a linear mixed-effects sensitivity analysis.

02

Conditions studied

  • Apical Periodontitis
  • Pulp Disease, Dental
  • Device Reliability
  • Device Performance

Keywords

  • Endodontics
  • Root Canal Therapy
  • Cone-Beam Computed Tomography
  • Dental Pulp Cavity
  • Working Length
  • Diagnostic Accuracy
  • Microscopy
03

In context

Periapical Periodontitis

281 studies on the registry are indexed under Periapical Periodontitis; 79 are open to participants now.

This study's enrollment of 41 is below the median of 60 across 246 interventional studies indexed under Periapical Periodontitis.

Browse Periapical Periodontitis studies →

Lead sponsor

Riyadh Elm University is the lead sponsor of 26 studies on the registry; 10 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

The criteria were revised on the registry on Nov 4, 2026. See what changed

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
Yes

Eligibility criteria

-Inclusion Criteria: Age ≥18 years Written Single-rooted permanent tooth Mature apical foramen Single canal Tooth requiring clinically indicated extraction Tooth requiring primary nonsurgical root canal treatment Canal curvature \<20° Canal negotiable to the apical foramen

Exclusion Criteria:

-Patient-related: Implantable electronic devices Relevant medical history or anticipated complications related to extraction Known allergies to study materials

-Tooth-related: Previous endodontic treatment Trauma Hypercementosis Root resorption Canal curvature ≥20° Extensive restorations Canal obliteration Failed rubber dam isolation

Terms in these criteria, in plain language(2)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

Contraindication

A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.

05

Study design

Phase
Not applicable
Primary purpose
Diagnostic
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
41 participants (actual)

Study arms

  • Experimental
    Root ZX3 Working-Length Determination

    Participants underwent clinical pulpal and apical diagnosis followed by in vivo working-length determination using the Root ZX3 in single-rooted permanent teeth before clinically indicated extraction. After extraction, the same teeth underwent CBCT assessment and direct microscopic determination of the apical foramen. Root ZX3 measurements were compared with the microscopic working length as the reference standard, while CBCT measurements were evaluated for comparison. Root ZX3 measurement error was also assessed according to combined pulpal and apical diagnostic status.

    Device: Root ZX3 Electronic Apex Locator

Interventions

  • DeviceRoot ZX3 Electronic Apex Locator

    The Root ZX3 electronic apex locator was used for in vivo working-length determination during primary nonsurgical root canal treatment. Following access preparation, preflaring, and irrigation, a size 10 or 15 K-file was advanced through the canal until the device indicated the apical foramen. A stable reading for at least 5 seconds was required, and the file position was measured from a standardized coronal reference point. The measurement was repeated under identical conditions to evaluate intraoperator repeatability. After extraction, the Root ZX3 measurements were compared with the actual working length determined by direct microscopic visualization of the apical foramen. CBCT working-length measurements were also obtained independently for comparison.

06

What researchers measure

Primary outcomes

  1. Diagnostic Accuracy of the Root ZX3 Electronic Apex Locator for Working-length Determination

    The diagnostic accuracy of the Root ZX3 electronic apex locator was evaluated by comparing electronic working-length measurements with microscopic actual working length, which served as the reference standard. Accuracy was assessed as the proportion of measurements within ±0.5 mm and ±1.0 mm of the reference standard. Agreement was also evaluated using mean differences and Bland-Altman analysis.

    Time frame: during endodontic treatment before tooth extraction

07

Results

Posted Nov 4, 2026
Limitations and caveats
This was a single-center study including only single-rooted permanent teeth indicated for extraction. Results may not be generalizable to multirooted teeth, teeth with complex canal anatomy, or different clinical settings.

Participant flow

Patients requiring extraction of single-rooted permanent teeth were screened for eligibility.

Participant flow — Overall Study
MilestoneRoot ZX3 Working-Length Determination
Started41
Completed41
Not completed0

Outcome measures

PrimaryDiagnostic Accuracy of the Root ZX3 Electronic Apex Locator for Working-length Determination

The diagnostic accuracy of the Root ZX3 electronic apex locator was evaluated by comparing electronic working-length measurements with microscopic actual working length, which served as the reference standard. Accuracy was assessed as the proportion of measurements within ±0.5 mm and ±1.0 mm of the reference standard. Agreement was also evaluated using mean differences and Bland-Altman analysis.

Time frame:
during endodontic treatment before tooth extraction
Reported as:
Number · Percent of teeth
Diagnostic Accuracy of the Root ZX3 Electronic Apex Locator for Working-length Determination
Percent of teethRoot ZX3 Working-Length Determination
Accuracy within ±0.5 mm88.30
Accuracy within ±1.0 mm98.7

Adverse events

Collected over From enrollment through 1 week after tooth extraction. Non-serious events are listed at a 5% frequency threshold.

Adverse event summary by group
GroupDeathsSeriousOther
Root ZX3 Working-Length Determination0/41 (0%)0/41 (0%)0/41 (0%)

Baseline characteristics

Baseline characteristics were assessed in 41 enrolled participants. Working-length analyses were performed on 77 eligible single-rooted permanent teeth.

Age, Continuous
Age, Continuous(Years)Root ZX3 Working-Length Determination
Mean41.59 ± 10.70
Sex: Female, Male
Sex: Female, Male(Participants)Root ZX3 Working-Length Determination
Female26
Male15
Race and Ethnicity Not Collected
Race and Ethnicity Not Collected(Participants)Root ZX3 Working-Length Determination
Region of Enrollment
Region of Enrollment(Participants)Root ZX3 Working-Length Determination
Saudi Arabia41
08

Study locations

1 site
  • Abier alhekeir
    Riyadh, Riyadh Region 12755, Saudi Arabia
09

References and documents

Publications

  • Dunlap CA, Remeikis NA, BeGole EA, Rauschenberger CR. An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals. J Endod. 1998 Jan;24(1):48-50. doi: 10.1016/S0099-2399(98)80214-8. PubMed 9487868 ↗
  • Izadi A, Golmakani F, Kazeminejad E, Mahdavi Asl A. Accuracy of Working Length Measurement Using Cone Beam Computed Tomography at Three Field of View Settings, Conventional Radiography, and Electronic Apex Locator: An Ex-vivo Study. Eur Endod J. 2024 Aug 22;9(3):266-272. doi: 10.14744/eej.2023.97769. PubMed 39102662 ↗

Study documents

PDFs hosted by the registry, ClinicalTrials.gov.

Individual participant data

Plan to share: No — Individual participant data will not be shared publicly. The study dataset and protocol are available from the corresponding author upon reasonable request, subject to appropriate institutional and ethical considerations.

10

Timeline

1 registry update since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Ran from Oct 2025 to primary completion in Feb 2026, 4 months.

Results were first posted in Nov 2026, 8 months after primary completion.

Of 172 non-industry interventional studies with no phase under Periapical Periodontitis, half reached primary completion within 12 months of starting (the median), counting those still running; a quarter within 6 and three quarters within 19. This study's 4 months is below that.

Counting every sponsor, half of 173 studies reached it within 12 months; a quarter within 6 and three quarters within 19.

How these figures are worked out, and which studies are left out of them.

Registered
Jul 1, 2026
First posted
Jul 8, 2026
StartActual
Oct 19, 2025
Primary completionActual
Feb 28, 2026
CompletionActual
Jun 30, 2026
Results first posted
Nov 4, 2026
Last update
Nov 4, 2026
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
Results
Results posted
posted Nov 4, 2026
Eligibility
Criteria largely rewritten (15 changes)
What changed in the criteria
  • Added-Inclusion Criteria: Age ≥18 years Written informed consent Single-rooted permanent tooth Mature apical foramen Single canal Tooth requiring clinically indicated extraction Tooth requiring primary nonsurgical root canal treatment Canal curvature <20° Canal negotiable to the apical foramen
  • AddedExclusion Criteria:
  • Added-Patient-related: Implantable electronic devices Relevant medical history Contraindications or anticipated complications related to extraction Known allergies to study materials
  • Added-Tooth-related: Previous endodontic treatment Trauma Hypercementosis Root resorption Canal curvature ≥20° Extensive restorations Canal obliteration Failed rubber dam isolation
Inclusion criteria
  • Removed* Adults (≥18 years) requiring extraction of a single-rooted permanent tooth for prosthodontic, periodontal, orthodontic, or non-restorable reasons.
  • RemovedTooth requiring primary nonsurgical root canal treatment.
  • RemovedFully formed root with a closed apex.
  • RemovedAbility to provide written informed consent.
Exclusion criteria
  • RemovedTeeth with root resorption (internal or external).
  • RemovedTeeth with root perforation or previous endodontic treatment.
  • RemovedTeeth with immature (open) apices.
  • RemovedTeeth with root fractures.
  • RemovedTeeth in which apical patency could not be achieved.
  • RemovedTeeth with no electronic working-length measurement obtained using the Root ZX3.
  • RemovedTeeth that fractured during extraction, preventing microscopic determination of the actual working length.
Nov 4, 2026
Primary outcomes
1 edited
What changed in the outcomes
  • EditedDiagnostic accuracyAccuracy of the Root ZX3 electronic apex locatorElectronic Apex Locator for workingWorking-length determinationDeterminationTime frame: during endodontic treatment before tooth extraction
Nov 4, 2026
Secondary outcomes
1 removed
What changed in the outcomes
  • RemovedRepeatability of Root ZX3 measurementsTime frame: before tooth extrac
Nov 4, 2026
Title
In Vivo-Ex Vivo Evaluation of the Root ZX3 for Working-Length Determination→In-Vivo Diagnostic Accuracy and Repeatability of Root ZX3 for Working-Length Determination in Single-Rooted Teeth: Agreement With CBCT and Microscopic Validation
Nov 4, 2026
Show all 1 update
  1. Nov 4, 2026
    Results posted
    Eligibility Criteria largely rewritten (15 changes)
    What changed in the criteria
    • Added-Inclusion Criteria: Age ≥18 years Written informed consent Single-rooted permanent tooth Mature apical foramen Single canal Tooth requiring clinically indicated extraction Tooth requiring primary nonsurgical root canal treatment Canal curvature <20° Canal negotiable to the apical foramen
    • AddedExclusion Criteria:
    • Added-Patient-related: Implantable electronic devices Relevant medical history Contraindications or anticipated complications related to extraction Known allergies to study materials
    • Added-Tooth-related: Previous endodontic treatment Trauma Hypercementosis Root resorption Canal curvature ≥20° Extensive restorations Canal obliteration Failed rubber dam isolation
    Inclusion criteria
    • Removed* Adults (≥18 years) requiring extraction of a single-rooted permanent tooth for prosthodontic, periodontal, orthodontic, or non-restorable reasons.
    • RemovedTooth requiring primary nonsurgical root canal treatment.
    • RemovedFully formed root with a closed apex.
    • RemovedAbility to provide written informed consent.
    Exclusion criteria
    • RemovedTeeth with root resorption (internal or external).
    • RemovedTeeth with root perforation or previous endodontic treatment.
    • RemovedTeeth with immature (open) apices.
    • RemovedTeeth with root fractures.
    • RemovedTeeth in which apical patency could not be achieved.
    • RemovedTeeth with no electronic working-length measurement obtained using the Root ZX3.
    • RemovedTeeth that fractured during extraction, preventing microscopic determination of the actual working length.
    Primary outcomes 1 edited
    What changed in the outcomes
    • EditedDiagnostic accuracyAccuracy of the Root ZX3 electronic apex locatorElectronic Apex Locator for workingWorking-length determinationDeterminationTime frame: during endodontic treatment before tooth extraction
    Secondary outcomes 1 removed
    What changed in the outcomes
    • RemovedRepeatability of Root ZX3 measurementsTime frame: before tooth extrac
    Title In Vivo-Ex Vivo Evaluation of the Root ZX3 for Working-Length Determination→In-Vivo Diagnostic Accuracy and Repeatability of Root ZX3 for Working-Length Determination in Single-Rooted Teeth: Agreement With CBCT and Microscopic Validation
    + 9 other changes: index terms, verification date, responsible party, oversight details, description, conditions, design details, arm descriptions and data sharing statement

From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗

11

Registry details

Key details

Study ID
NCT07689838
Lead sponsor
Riyadh Elm University
Responsible party
ABIER FAHAD M ALHEKEIR (Endodontist, Riyadh Elm University) — Principal investigator
First posted
Jul 8, 2026
Start date
Oct 19, 2025
Primary completion
Feb 28, 2026
Completion
Jun 30, 2026
Results posted
Nov 4, 2026
Last update
Nov 4, 2026

Study contacts

Abier Fahad Alhekeir
principal investigator · Riyadh Elm University

Oversight

Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Oct 2026. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion