ClinicalTrials.gg
Enrolling by invitationNCT07617428Updated Nov 23, 2026

Clinical Validation of a Blood Loss Monitoring System

An observational study in Intraoperative Blood Loss, sponsored by Lanzhou University Second Hospital. Enrolling by invitation at 3 sites in China. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2026-11-23.

Sponsored by Lanzhou University Second Hospital · Observational

How we know

Updated Nov 23, 2026Interventions changedPrimary completion moved+4 moreGo to Updates ↓

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Study type
Observational
Model
Case-only
Time perspective
Prospective
Enrollment
170
Ages
18 Years and older
Sex
All
01

Where this study stands

Counted across the records on this site · 2026-11-25

Among 97 studies in Hemorrhage with a site in China — 27 open to participants now, 29 under way, 5 of them phase 3. Hemorrhage · China.

Planned enrollment
14th of 20
170 · median 341
Started
2025
with 10 others
Observational
20 of 97
6 open now
Primary completion
2026-12
later than 8 of 28 live
Registered
91st of 97
by date

Among the 97 studies in Hemorrhage with a site in China, this one is the 14th largest by planned enrollment of the 20 observational ones that give a count, is one of 11 that started in 2025, is one of 20 observational ones, reaches primary completion later than 8 of the 28 other live ones, and was the 91st registered.

Hemorrhage

1,384 studies on the registry are indexed under Hemorrhage; 245 are open to participants now.

Browse Hemorrhage studies →

Open to participants now

27 of the 97 studies in Hemorrhage with a site in China are open now. Recruiting first, the newest first:

22 more — sign in →

All 27 open studies →

A study can be open while its sites in China have not opened yet or have stopped. Only those recruiting at a site in China →

Who these studies take

Of the 171 Hemorrhage studies recruiting now, 109 (64%) set no upper age limit and 41 (24%) stop at 75 or younger; 26 take children under 18; 21 take healthy volunteers.

This study: 18 Years and older · all sexes · no healthy volunteers.

The full table on the hub →

This tab as a report to print or save as PDF → With an account.

Was this useful?
Get alerts for this landscapeDownload CSVNarrow it in search →With an account: a weekly mail of what changed among 97 studies in Hemorrhage with a site in China, or all of them as a file.
02

Study summary

This observational study aims to evaluate the practicality of a novel multifunctional intraoperative blood loss monitoring system in real-world surgical settings. The primary questions it seeks to address are:

Using the direct measurement method as the reference standard, what is the magnitude of measurement error of the monitoring system, and does it tend to overestimate or underestimate blood loss? Does the monitoring system demonstrate superior accuracy compared with visual estimation, the gravimetric method, and the hemoglobin concentration-based method? During surgery, intraoperative blood loss will be measured simultaneously using five approaches: the novel multifunctional monitoring system, the direct measurement method, visual estimation, the gravimetric method, and the hemoglobin concentration method. These measurements will be conducted without interfering with the surgical procedure.

03

Conditions studied

  • Intraoperative Blood Loss

Browse trials for

Keywords

  • blood loss
  • Clinical Validation
  • Monitoring Equipment
04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No
Sampling method
Non-probability sample

Study population

The study population will be recruited from adult patients undergoing elective urological and general surgical procedures at two tertiary hospitals in China, including Lanzhou University Second Hospital and Lanzhou University First Hospital. Participants will be selected from routine clinical practice settings where intraoperative blood loss monitoring is required. This population represents adult surgical patients managed under standard perioperative care, providing a real-world clinical context for evaluating intraoperative blood loss measurement methods.

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Patients undergoing elective urological or general surgical procedures
  • Age 18 years or older
  • Preoperative concentration available
  • Intraoperative blood loss assessment required during surgery

Exclusion criteria

Exclusion Criteria:

  • Patients with incomplete intraoperative blood loss measurement data,
  • Severe hemolysis or other conditions that may affect measurement
  • Emergency surgery
  • Intraoperative blood loss assessment required during surgery 24 hours after surgery
  • Refusal to participate, when applicable
Terms in these criteria, in plain language(1)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Hemoglobin (Hb)

The protein in red blood cells that carries oxygen. A low level is anemia, which can cause tiredness and breathlessness. Measured in g/dL or g/L (9 g/dL is 90 g/L).

05

Study design

Observational model
Case-only
Time perspective
Prospective
Enrollment
170 participants (estimated)
Target follow-up
1 Day
Patient registry
Yes

Groups and cohorts

  • Self-controlled

    This study includes a single self-controlled cohort of patients undergoing urological surgical procedures. All participants will undergo simultaneous intraoperative blood loss assessment using five different methods within the same surgical procedure: a novel multifunctional intraoperative blood loss monitoring system, the direct measurement method (reference standard), visual estimation, the gravimetric method, and the hemoglobin concentration-based method. No intervention is applied in this observational study. All measurements are performed according to a predefined protocol and do not interfere with the standard surgical workflow. The purpose of this design is to enable within-subject comparison of measurement accuracy across different methods under identical clinical conditions.

  • Workflow feasibility and real-time responsiveness cohort

    A separate workflow feasibility cohort assessed clinical implementation during routine surgery; these cases were excluded from accuracy and agreement analyses. Used sponges were inserted when no longer needed in the operative field, and suctioned fluid entered intermittently via the suction pathway. A sponge-processing event was each sponge insertion; a suction-response event was each visible episode of blood-containing fluid entering the pathway followed by an updated screen value. Response times were measured by two trained investigators independently reviewing de-identified intraoperative videos showing only the input port, suction pathway and display; disagreements were resolved by consensus or a third reviewer. Sponge response time was the interval from complete sponge insertion to stabilisation of the updated cumulative value; suction response time, from fluid entry to stabilisation; time to final result, from completion of final sample processing to availability of the final es

06

What researchers measure

Primary outcomes

  1. Absolute error of the automatic intraoperative blood loss monitor compared with the direct measurement method

    Absolute error is defined as the numerical difference between intraoperative blood loss measured by the automatic intraoperative blood loss monitor and intraoperative blood loss measured by the direct measurement method. A positive value indicates that the monitor overestimates blood loss compared with the direct measurement method, whereas a negative value indicates underestimation. Unit of Measure: Milliliters (mL)

    Time frame: At the end of surgery

Secondary outcomes

  1. Percentage error of the automatic intraoperative blood loss monitor compared with the direct measurement method

    Percentage error is defined as the relative difference between intraoperative blood loss measured by the automatic intraoperative blood loss monitor and intraoperative blood loss measured by the direct measurement method, expressed as a percentage of the average value obtained by the two methods. A positive value indicates overestimation by the monitor, whereas a negative value indicates underestimation. Unit of Measure: Percentage

    Time frame: At the end of surgery

  2. Absolute error of visual estimation compared with the direct measurement method

    Absolute error is defined as the numerical difference between intraoperative blood loss estimated by visual estimation and intraoperative blood loss measured by the direct measurement method. A positive value indicates overestimation by visual estimation, whereas a negative value indicates underestimation. Unit of Measure: Milliliters

    Time frame: At the end of surgery

  3. Absolute error of the gravimetric method compared with the direct measurement method

    The accuracy of five methods (monitoring system, direct measurement, visual Absolute error is defined as the numerical difference between intraoperative blood loss estimated by the gravimetric method and intraoperative blood loss measured by the direct measurement method. A positive value indicates overestimation by the gravimetric method, whereas a negative value indicates underestimation. Unit of Measure: Milliliters

    Time frame: At the end of surgery

  4. Absolute error of the hemoglobin concentration-based method compared with the direct measurement method

    Absolute error is defined as the numerical difference between blood loss estimated by the hemoglobin concentration-based method and intraoperative blood loss measured by the direct measurement method. The hemoglobin concentration-based estimate is calculated using preoperative hemoglobin concentration, hemoglobin concentration measured 24 hours after surgery, and estimated blood volume. A positive value indicates overestimation by the hemoglobin concentration-based method, whereas a negative value indicates underestimation. Unit of Measure: Milliliters

    Time frame: 24 hours after surgery

  5. Intraclass correlation coefficient between the automatic intraoperative blood loss monitor and the direct measurement method

    The intraclass correlation coefficient is used to quantify agreement between intraoperative blood loss measured by the automatic intraoperative blood loss monitor and intraoperative blood loss measured by the direct measurement method. Higher values indicate stronger agreement between the two methods. Unit of Measure: Unitless coefficient

    Time frame: At the end of surgery

  6. Bland-Altman mean bias between the automatic intraoperative blood loss monitor and the direct measurement method

    Bland-Altman mean bias is defined as the mean difference between intraoperative blood loss measured by the automatic intraoperative blood loss monitor and intraoperative blood loss measured by the direct measurement method. A positive mean bias indicates systematic overestimation by the monitor, whereas a negative mean bias indicates systematic underestimation.

    Time frame: Unit of Measure: Milliliters

  7. Bland-Altman limits of agreement between the automatic intraoperative blood loss monitor and the direct measurement method

    Bland-Altman limits of agreement describe the range within which most differences between intraoperative blood loss measured by the automatic intraoperative blood loss monitor and intraoperative blood loss measured by the direct measurement method are expected to fall. Unit of Measure: Milliliters

    Time frame: At the end of surgery

  8. workflow feasibility cohort

    Because each patient could contribute multiple sponge-processing and suction-response events, response times were first summarised within each patient and patient-level medians were then summarised across the cohort. Case-level feasibility outcomes were reported as counts and percentages.

    Time frame: At the end of surgery

  9. Agreement between monitor-derived and independent reference blood loss

    Ratio of monitor-derived to independent reference blood loss (EBL\_monitor / EBL\_ref), with 95% limits of agreement. Because incomplete recovery produces an error proportional to blood loss, agreement is assessed on the logarithmic scale and back-transformed; results are expressed as percentage differences. The prespecified clinically acceptable margin is +/-20% or +/-50ml of the reference value, anchored to the hemoglobin content of half a unit of allogeneic whole blood. The proportion of measurements falling within this margin is reported. Values below the limit of quantification are assigned LOQ/sqrt(2) in the primary analysis; sensitivity analyses assign zero or exclude such measurements.

    Time frame: Intraoperative; assessed within 30 minutes after completion of the surgical procedure and final sample processing.

07

Study locations

3 sites
08

References and documents

Individual participant data

Plan to share: Undecided — The clinical data involves sensitive patient privacy. We are currently undecided on sharing the IPD, as it requires specific informed consent from the patients and authorization from the hospital's ethics committee.

No publications or documents are linked to this record.

09

Timeline

2 registry updates since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedDate before it movedWhere the date was before it movedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Started Sep 2025 (actual). Primary completion is estimated for Dec 2026, 15 months after the start.

Of 134 non-industry observational studies under Hemorrhage, half reached primary completion within 38 months of starting (the median), counting those still running; a quarter within 15 and three quarters within 78. This study's planned 15 months is below that.

Counting every sponsor, half of 158 studies reached it within 33 months; a quarter within 15 and three quarters within 74.

Since we started tracking on Sep 25, 2026, the dates moved once, on Oct 15, 2026: primary completion Jun 2026 → Dec 2026 and completion Jun 2026 → Dec 2026.

Earlier changes are on the record history on ClinicalTrials.gov ↗

How these figures are worked out, and which studies are left out of them.

Registered
May 5, 2026
First posted
Jun 1, 2026
StartActual
Sep 10, 2025
Primary completionEst.
Dec 30, 2026was Jun 2026
CompletionEst.
Dec 30, 2026was Jun 2026
Last update
Nov 23, 2026
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
Sites
1 site added, 1 site removed
Show site
  • Affiliated Hospital of Gansu University of Chinese Medicine · Lanzhou, China
Show 1 removed
  • Gansu Provincial People's Hospital · Lanzhou, China
Nov 23, 2026
Primary completion
Jun 30, 2026→Dec 30, 2026
Oct 15, 2026
Study completion
Jun 30, 2026→Dec 30, 2026
Oct 15, 2026
Enrollment
120→170
Oct 15, 2026
Interventions
Arms added: Workflow feasibility and real-time responsiveness cohort
across 2 updates, Oct 15, 2026 – Nov 23, 2026
Secondary outcomes
Revised in 2 updates
What changed on Oct 15, 2026
  • Addedworkflow feasibility cohortTime frame: At the end of surgery
  • AddedDevice blood recovery fraction (f)Time frame: Intraoperative; assessed within 30 minutes after completion of the surgical procedure and final sample processing.
  • AddedAgreement between monitor-derived and independent reference blood lossTime frame: Intraoperative; assessed within 30 minutes after completion of the surgical procedure and final sample processing.
What changed on Nov 23, 2026
  • RemovedDevice blood recovery fraction (f)Time frame: Intraoperative; assessed within 30 minutes after completion of the surgical procedure and final sample processing.
  • DescriptionAgreement between monitor-derived and independent reference blood loss: how it is measured was reworded
across 2 updates, Oct 15, 2026 – Nov 23, 2026
Show all 2 updates
  1. Nov 23, 2026
    1 site added, 1 site removed
    Show site
    • Affiliated Hospital of Gansu University of Chinese Medicine · Lanzhou, China
    Show 1 removed
    • Gansu Provincial People's Hospital · Lanzhou, China
    Secondary outcomes 1 removed, 1 description edited
    What changed in the outcomes
    • RemovedDevice blood recovery fraction (f)Time frame: Intraoperative; assessed within 30 minutes after completion of the surgical procedure and final sample processing.
    • DescriptionAgreement between monitor-derived and independent reference blood loss: how it is measured was reworded
    Interventions Arms removed: Blood Recovery Subgroup: Independent Reference Assessment of Device Recovery Fraction
  2. Oct 15, 2026
    Primary completion Jun 30, 2026→Dec 30, 2026
    Study completion Jun 30, 2026→Dec 30, 2026
    Enrollment 120→170
    Secondary outcomes 3 added
    What changed in the outcomes
    • Addedworkflow feasibility cohortTime frame: At the end of surgery
    • AddedDevice blood recovery fraction (f)Time frame: Intraoperative; assessed within 30 minutes after completion of the surgical procedure and final sample processing.
    • AddedAgreement between monitor-derived and independent reference blood lossTime frame: Intraoperative; assessed within 30 minutes after completion of the surgical procedure and final sample processing.
    Interventions Arms added: Workflow feasibility and real-time responsiveness cohort·Blood Recovery Subgroup: Independent Reference Assessment of Device Recovery Fraction

From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗

10

Registry details

Key details

Study ID
NCT07617428
Lead sponsor
Lanzhou University Second Hospital
Collaborators
LanZhou University
Responsible party
Zhiping Wang (Professor; Chief Physician, Lanzhou University Second Hospital) — Principal investigator
First posted
Jun 1, 2026
Start date
Sep 10, 2025
Primary completion
Dec 30, 2026 (estimated)
Completion
Dec 30, 2026 (estimated)
Last update
Nov 23, 2026

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

No contact was published for this record. The registry link below has the sponsor’s details.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion