ClinicalTrials.gg
Status unknownNCT05320185Updated Sep 21, 2022

Evaluation on the Effectiveness and Safety of RuiXin-CoronaryAI for Diagnosis of Coronary Artery Stenosis

An observational study in Coronary Artery Disease, Artificial Intelligence and Coronary Artery Stenosis, sponsored by Shenzhen Raysight Intelligent Medical Technology Co., Ltd.. Status unknown at 3 sites in China. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2022-09-21.

Sponsored by Shenzhen Raysight Intelligent Medical Technology Co., Ltd. · Observational

How we know

The sponsor has not verified this record recently (last verified Mar 2022), so the status shown — last known as Recruiting — may be out of date.

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Study type
Observational
Model
Cohort
Time perspective
Retrospective
Enrollment
615
Ages
18 Years and older
Sex
All
01

Where this study stands

Counted across the records on this site · 2026-11-24

Among 545 studies in Coronary Artery Disease with a site in China — 179 open to participants now, 210 under way, 7 of them phase 3. Coronary Artery Disease · China.

Planned enrollment
113th of 218
615 · median 770
Started
2021
with 40 others
Observational
219 of 545
82 open now
Registered
306th of 545
by date

Among the 545 studies in Coronary Artery Disease with a site in China, this one is the 113th largest by planned enrollment of the 218 observational ones that give a count, is one of 41 that started in 2021, is one of 219 observational ones, and was the 306th registered.

Coronary Artery Disease

4,866 studies on the registry are indexed under Coronary Artery Disease; 894 are open to participants now.

Browse Coronary Artery Disease studies →

Open to participants now

179 of the 545 studies in Coronary Artery Disease with a site in China are open now. Recruiting first, the newest first:

174 more — sign in →

All 179 open studies →

A study can be open while its sites in China have not opened yet or have stopped. Only those recruiting at a site in China →

Who these studies take

Of the 593 Coronary Artery Disease studies recruiting now, 404 (68%) set no upper age limit and 68 (11%) stop at 75 or younger; 37 take children under 18; 50 take healthy volunteers.

This study: 18 Years and older · all sexes · no healthy volunteers.

The full table on the hub →

This tab as a report to print or save as PDF → With an account.

Was this useful?
Get alerts for this landscapeDownload CSVNarrow it in search →With an account: a weekly mail of what changed among 545 studies in Coronary Artery Disease with a site in China, or all of them as a file.
02

Study summary

With the emergence of advanced technology to date in the artificial intelligence (AI), computer aided diagnosis has gradually gained its popularity in the field of healthcare. Particularly, in the clinical practice of coronary artery disease diagnosis, the application of AI could be of great implication in alleviating the shortage of medical sources. To evaluate the effectiveness and safety of the AI-based coronary CT angiographic analysis software (RuiXin-CoronaryAI) for diagnosis of coronary artery stenosis, a retrospective, multi-center, cross-over designed, blinded, sensitivity superiority and specificity non-inferiority clinical trial will be conducted.

Read the detailed description

Patients ≥18 years old with suspected or known coronary artery disease who underwent CCTA will be included. CCTA images of subjects should be of good quality up to the DICOM 3.0 standards, obtained by CT scan with ≥64-slices. The subjects with unqualified CTA will be excluded. CCTA images will be analyzed in three methods (3 groups). Control group: CCTA images will be visually evaluated by physicians. Experiment group: CCTA images will be evaluated by physicians using RuiXin-CoronaryAI. Reference group: CCTA images will be visually evaluated by cardiologists with at least 10 years experiences, and the conclusions they offer will be used as golden standard. Primary outcomes are diagnostic sensitivity and specificity of RuiXin-CoronaryAI and coronary CTA for diagnosis of ischemia on a per-vessel basis. The effectiveness of RuiXin-CoronaryAI for diagnosis of coronary artery stenosis will be conducted by testing superiority of diagnostic sensitivity and non-inferiority of specificity.

03

Conditions studied

  • Coronary Artery Disease
  • Artificial Intelligence
  • Coronary Artery Stenosis
  • CT Angiography
04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No
Sampling method
Probability sample

Study population

Patients ≥18 years old with suspected or known coronary artery disease who underwent CCTA examination.

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  1. layer thickness of CCTA images should be less than 1mm, image quality should be up to DICOM 3.0 standards;
  2. vessels should be clearly developed, contrast medium ought to be well filled, the average of CT value of aortic root cavity should be between 325-600HU in CCTA image;
  3. remodeling of vessels should be intact, including coronary artery and branches, without missed or inaccurate slices;
  4. CCTA image should be obtained from single- or dual-source computed tomography (CT) scanners with a minimum of 64 detector rows.

Exclusion criteria

Exclusion Criteria:

  1. CCTA image is of poor quality due to motion artifact, severe calcification, metal coverage, noise, poor contrast medium injection and other variables influencing the diagnosis of stenosis;
  2. previous percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG);
  3. anomalous origin of coronary artery;
  4. other non-atherosclerosis-related coronary diseases like coronary artery fistula, aneurysm, coronary artery ectasia, arteritis coronaria, etc.;
  5. repeated enrollment;
  6. other conditions not suitable for enrollment.
05

Study design

Observational model
Cohort
Time perspective
Retrospective
Enrollment
615 participants (estimated)
Patient registry
No

Groups and cohorts

  • Control group

    CCTA images will be visually evaluated by physicians.

  • Experiment group

    CCTA images will be evaluated by physicians using RuiXin-CoronaryAI.

    Device: RuiXin-CoronaryAI software

  • Reference group

    CCTA images will be visually evaluated by cardiologists with at least 10 years experiences, and the conclusions they offer will be used as golden standard.

Interventions

  • DeviceRuiXin-CoronaryAI software

    RuiXin-CoronaryAI, based on Computed Tomography Angiography (CTA) and was independently designed by RaysightMed Inc., which has been already authorized by National Medical Products Administration (NMPA).

06

What researchers measure

Primary outcomes

  1. Per-vessel diagnostic sensitivity of RuiXin-CoronaryAI for diagnosis of coronary artery stenosis

    Outcome measures were comparing RuiXin-CoronaryAI to CTA on a per-vessel basis

    Time frame: 1 day; Incident time for CTA examination was dependent on the length of time on the CT scaner. RuiXin-CoronaryAI examination was done remotely at Raysight's processing center in Shenzhen with a turnaround time of 24 hours from CT scan.

  2. Per-vessel diagnostic specificity of RuiXin-CoronaryAI for diagnosis of coronary artery stenosis

    Outcome measures were comparing RuiXin-CoronaryAI to CTA on a per-vessel basis

    Time frame: 1 day; Incident time for CTA examination was dependent on the length of time on the CT scaner. RuiXin-CoronaryAI examination was done remotely at Raysight's processing center in Shenzhen with a turnaround time of 24 hours from CT scan.

Secondary outcomes

  1. Per-patient diagnostic sensitivity of RuiXin-CoronaryAI for diagnosis of coronary artery stenosis

    Outcome measures were comparing RuiXin-CoronaryAI to CTA on a per-patient basis

    Time frame: 1 day; Incident time for CTA examination was dependent on the length of time on the CT scaner. RuiXin-CoronaryAI examination was done remotely at Raysight's processing center in Shenzhen with a turnaround time of 24 hours from CT scan.

  2. Per-patient diagnostic specificity of RuiXin-CoronaryAI for diagnosis of coronary artery stenosis

    Outcome measures were comparing RuiXin-CoronaryAI to CTA on a per-patient basis

    Time frame: 1 day; Incident time for CTA examination was dependent on the length of time on the CT scaner. RuiXin-CoronaryAI examination was done remotely at Raysight's processing center in Shenzhen with a turnaround time of 24 hours from CT scan.

07

Study locations

3 of 3 sites recruiting
  • Beijing Hospital
    Beijing, Beijing 100730, China
    Recruiting
    • Min Chen · Contact
  • Sun Yat-sen Memorial Hospital
    Guangzhou, Guangdong 510120, China
    Recruiting
    • Jun Shen · Contact
  • Tongji Hospital
    Wuhan, Hubei 430030, China
    Recruiting
08

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reached

Ran from Jul 2021 to primary completion in Jul 2022, 12 months.

How these figures are worked out, and which studies are left out of them.

Registered
Mar 16, 2022
First posted
Apr 11, 2022
StartActual
Jul 28, 2021
Primary completionActual
Jul 30, 2022
CompletionEst.
Dec 30, 2022
Last update
Sep 21, 2022
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Sep 21, 2022, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
09

Registry details

Key details

Study ID
NCT05320185
Lead sponsor
Shenzhen Raysight Intelligent Medical Technology Co., Ltd.
Responsible party
Sponsor
First posted
Apr 11, 2022
Start date
Jul 28, 2021
Primary completion
Jul 30, 2022
Completion
Dec 30, 2022 (estimated)
Last update
Sep 21, 2022

Study contacts

Liming Xia
Contact
lmxia@tjh.tjmu.edu.cn
13607176908
Lihui Li
Contact
lihui.li@raysightmed.com
13636480344
Liming Xia
study director · Tongji Hospital

Oversight

Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is status unknown, as verified in Mar 2022. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion