Servo Controlled Oxygen Targeting (SCO2T) Study: Masimo vs. Nellcor

An interventional study of Servo control (closed-loop automatic control of the inspiratory fraction of oxygen (FiO2)) - IntellO2 OAM in Premature, Premature Infant and Oxygen Therapy, sponsored by University of Edinburgh. Completed at 1 site in United Kingdom. Open to participants aged 2 Days and older, including healthy volunteers. Per ClinicalTrials.gov, last updated 2024-09-25.

Sponsored by University of Edinburgh · Not applicable, Interventional, and Treatment

Phase
Not applicable
Study type
Interventional
Enrollment
25
Allocation
Randomized
Ages
2 Days and older
Sex
All
01

Study summary

Most premature babies require oxygen therapy. There is uncertainty about what oxygen levels are the best. The oxygen levels in the blood are measured using a monitor called a saturation monitor and the oxygen the baby breathes is adjusted to keep the level in a target range. Although there is evidence that lower oxygen levels maybe harmful, it is not known how high they need to be for maximum benefit. Very high levels are also harmful. Saturation monitors are not very good for checking for high oxygen levels. For this a different kind of monitor, called a transcutaneous monitor, is better.

Keeping oxygen levels stable is usually done by nurses adjusting the oxygen levels by hand (manual control). There is also equipment available that can do this automatically (servo control). It is not known which is best.

Research suggests that different automated devices control oxygen effectively as measured by the readings from their internal oxygen saturation monitoring systems. When compared to free-standing saturation monitors there appears to be variations in measured oxygen levels between devices. This could have important clinical implications.

This study aims to show the different achieved oxygen levels when babies are targeted to a set target range. Babies in the study will have both a saturation monitor and a transcutaneous oxygen monitor at the same time. Both types of monitor have been in long term use in neonatal units.

For a period of 12 hours, each baby will have their oxygen adjusted automatically using two different internal oxygen monitoring technologies (6 hours respectively). The investigators will compare the range of oxygen levels that are seen between the two oxygen saturation monitoring technologies.

The investigators will study babies born at less than 30 weeks gestation, who are at least 2 days old, on nasal high flow and still require added oxygen.

Read the detailed description

Presently oxygen is titrated against saturation (SpO2) by manual adjustment. Automated or servo-control systems have been developed that result in tighter control of SpO2 and more time spent in the intended target range. These systems are already in clinical use. Automated systems produce quite large fluctuations in fraction of inspired oxygen (FiO2) in order to keep SpO2 in range. It is possible that this could result in short periods of high or low oxygen tension (PO2) that are undetectable using saturation monitoring. Studies to date have examined the effects of manual and automated (servo) oxygen targeting on SpO2 but not on transcutaneous oxygen tension (TcPO2).

Research suggests that individual servo control devices control oxygen effectively as measured by the readings obtained from their internal SpO2 monitoring system. The device the investigators intend to study is available with two different oximeter monitoring systems. When compared to a separate free-standing SpO2 monitor the devices have a systematic bias in the clinically targeted range. Consequently, this could allow variations between infants in oxygenation large enough to influence important clinical outcome to go unrecognised.

There is a need to determine the achieved SpO2 and TcPO2 distributions associated with the use of different automated control systems as a first step in planning future trials. When this is measured over a small number of hours it is not anticipated that this would have an influence on clinical outcome.

This study is a prospective, single centre, randomised crossover trial of two different internal oximeter monitoring systems in an automated (servo) control device - IntellO2 (Vapotherm, USA) - delivering nasal high flow employing automated oxygen titration. Each infant will act as their own control. Infants born at less than 30 weeks gestation, greater than 48 hour of age and receiving supplementary oxygen will be eligible for inclusion.

The study will be undertaken in the Neonatal Unit at the Simpson Centre for Reproductive Health at the Royal Infirmary of Edinburgh.

Total study time is 12 hours for each infant. Infants will be randomised to commence on either Masimo oximetry or Nellcor oximetry using the Oxygen Assist Module (OAM), IntellO2 Vapotherm device. SpO2 (range 90-95%) will be continuously monitored on a second pulse oximetry probe connected to a bedside multiparameter monitor as per normal standard of care.

Additional monitoring will be carried out as shown below:

  1. TcPO2 monitoring
  2. FiO2 monitoring
  3. Heart rate monitoring (used to validate SpO2 readings)
  4. Arterial gas sampling (only if conducted by the direct care team as part of the routine care of the infant; no extra blood samples will be taken as part of the study)

FiO2 will be adjusted by the respiratory support device which has integrated automated oxygen control, set to maintain a SpO2 target range of 90-95%.The IntellO2 device uses Precision Flow technology (IntellO2, Vapotherm, USA). By means of a modified closed-loop algorithm, the devise uses MasimoSET or Nellcor pulse oximetry to target a user-set SpO2 value.

SpO2 readings will be downloaded directly from the multiparameter patient monitor. SpO2 will be measured using a Phillips MX500 multiparameter monitor (Phillips, Germany, CE 0366).TcPO2 will be measured using a SenTec Digital Monitoring System with OxiVent sensor (SenTec AG, Switzerland, European patent No. 1535055, CE 0120). Both monitors are routinely used in clinical practice. Transcutaneous data will be recorded contemporaneously and the site of the transcutaneous probe will be rotated on each infant every 2 hours. Control of sensor temperature and application duration are designed to meet all applicable standards and this monitoring device is used routinely in many neonatal units.

02

Conditions studied

  • Premature
  • Premature Infant
  • Oxygen Therapy
  • Hypoxia
  • Hyperoxia
  • Obstetric Labor, Premature

Keywords

  • Servo Control
  • Closed-Loop Automated Oxygen Control
  • Pulse oximeter technology
03

Who can participate

Ages eligible
2 Days and older
Sexes eligible
All
Accepts healthy volunteers
Yes

Inclusion criteria

  1. Infants born at less than 30 weeks gestation
  2. Infants greater than 48 hours of age
  3. Infants who are receiving supplementary oxygen
  4. Person with parental responsibility able to give consent

Exclusion criteria

Exclusion Criteria:

  1. Congenital anomalies that would prevent targeting SpO2 to 90-95% (e.g. cardiac defects)
  2. Clinical condition of an infant would impair accurateTcPO2 measurement (e.g. impaired perfusion or requirement of inotropic or vasopressor support)
  3. Parent/person with parental responsibility unable to give informed consent on behalf of the infant
  4. Infants born less than 22 weeks gestation
04

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Randomized
Intervention model
Crossover assignment
Masking
None (open label)
Enrollment
25 participants (actual)

Study arms

  • Experimental
    Servo control - Masimo oximetry technology (Oxygen Assist Module, IntellO2, Vapotherm)

    Automated control of oxygen. The oxygen saturation target range will be set to 90-95% (set to maintain an integral value of 93%) as per standard clinical practice. Automated oxygen control can be overridden by manual adjustment of oxygen at any time if this is considered necessary to optimise control of oxygenation according to current clinical targets.

    Device: Servo control (closed-loop automatic control of the inspiratory fraction of oxygen (FiO2)) - IntellO2 OAM

  • Active comparator
    Servo control - Nellcor oximetry technology (Oxygen Assist Module, IntellO2, Vapotherm)

    Automated control of oxygen. The oxygen saturation target range will be set to 90-95% (set to maintain an integral value of 93%) as per standard clinical practice. Automated oxygen control can be overridden by manual adjustment of oxygen at any time if this is considered necessary to optimise control of oxygenation according to current clinical targets.

    Device: Servo control (closed-loop automatic control of the inspiratory fraction of oxygen (FiO2)) - IntellO2 OAM

Interventions

  • DeviceServo control (closed-loop automatic control of the inspiratory fraction of oxygen (FiO2)) - IntellO2 OAM

    FiO2 adjustments will be made by the IntellO2 Oxygen Assist Module (OAM) for Precision Flow (IntellO2, Vapotherm, USA). By means of a modified closed-loop algorithm, the devise uses MasimoSET or Nellcor pulse oximetry to target a user-set SpO2 value. Manual adjustments of the inspired oxygen fraction can additionally be made as per standard care.

05

What researchers measure

Primary outcomes

  1. Incidence of hyperoxia and hypoxia on saturation monitoring

    To discover the percentage time spent within target SpO2 range of 90-95% when infants are targeted to an SpO2 range of 90-95% with an automated (servo) control device using two internal oximeter monitoring systems (Masimo and Nellcor).

    Time frame: 12 hours

Secondary outcomes

  1. Transcutaneous oxygen variability

    To discover the percentage time spent within a TcPO2 range of 50mmHg (6.7kPa) - 80mmHg (10.7kPa) when infants are targeted to an SpO2 range of 90-95% with an automated (servo) control device using two internal oximeter monitoring systems (Masimo and Nellcor).

    Time frame: 12 hours

  2. Saturation variability

    To discover the variability in SpO2 (measured by standard deviation) when infants are targeted to an SpO2 range of 90-95% with an automated (servo) control device using two internal oximeter monitoring systems (Masimo and Nellcor).

    Time frame: 12 hours

  3. Fraction of inspired oxygen variability

    To discover the variability in FiO2 (measured by standard deviation) when infants are targeted to an SpO2 range of 90-95% with an automated (servo) control device using two internal oximeter monitoring systems (Masimo and Nellcor).

    Time frame: 12 hours

  4. Pooled frequency histogram of TcPO2

    To generate a pooled frequency histogram of percentage time at a TcPO2 of below 30mmHg, 30-39.9mmHg, 40-49.9mmHg, 50-59.9mmHg, 60-69.9mmHg, 70-79.9mmHg, and 80mmHg and above for infants targeted to an SpO2 range of 90-95% with an automated (servo) control device using two internal oximeter monitoring systems (Masimo and Nellcor).

    Time frame: 12 hours

  5. Pooled frequency histogram of SpO2

    To generate a pooled frequency histogram of percentage time at each SpO2 point between 80 - 100% for infants targeted to an SpO2 range of 90-95% with an automated (servo) control device using two internal oximeter monitoring systems (Masimo and Nellcor).

    Time frame: 12 hours

  6. Pooled frequency histogram of FiO2

    To generate a pooled frequency histogram of the cumulative frequency at a FiO2 of 0.21-0.3, 0.31-0.4, 0.41-0.5, 0.51-0.6, 0.61-0.7, 0.81-0.9 and 0.91-1.0 for infants targeted to an SpO2 range of 90-95% with an automated (servo) control device using two internal oximeter monitoring systems (Masimo and Nellcor).

    Time frame: 12 hours

  7. Desaturations

    To discover the frequency of desaturations for infants targeted to an SpO2 range of 90-95% with an automated (servo) control device using two internal oximeter monitoring systems (Masimo and Nellcor).

    Time frame: 12 hours

  8. Desaturations

    To discover the duration of desaturations for infants targeted to an SpO2 range of 90-95% with an automated (servo) control device using two internal oximeter monitoring systems (Masimo and Nellcor).

    Time frame: 12 hours

  9. Desaturations

    To discover the depth of desaturations and the area (change in PO2 versus time) above and below the set PO2 threshold for infants targeted to an SpO2 range of 90-95% with an automated (servo) control device using two internal oximeter monitoring systems (Masimo and Nellcor).

    Time frame: 12 hours

06

Study locations

1 site
  • The Simpson Centre for Reproductive Health, Royal Infirmary Edinburgh
    Edinburgh, City Of Edinburgh EH16 4SA, United Kingdom
07

Registry details

Key details

Study ID
NCT04866342
Lead sponsor
University of Edinburgh
Collaborators
NHS Lothian
Responsible party
Sponsor
First posted
Apr 29, 2021
Start date
Nov 27, 2020
Primary completion
Aug 28, 2023
Completion
Aug 28, 2023
Last update
Sep 25, 2024

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in May 2024. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion