An interventional study of Implantation of trifocal IOL, Isatis TF (device under investigation) and Implantation of monofocal IOL, Isatis (control device) in Cataract and Lens Opacities, sponsored by Cutting Edge SAS. Completed at 7 sites in 2 countries. Open to participants aged 50 Years and older, including healthy volunteers. Per ClinicalTrials.gov, last updated 2025-02-12.
Sponsored by Cutting Edge SAS · Not applicable, Interventional, and Treatment
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 62 studies in Cataract with a site in Spain — 13 open to participants now, 13 under way, none of them phase 3. Cataract · Spain.
Among the 62 studies in Cataract with a site in Spain, this one is the 11th largest by enrollment of the 35 interventional ones that give a count, is one of 10 that started in 2021, is one of 31 with no phase, and was the 22nd registered.
1,635 studies on the registry are indexed under Cataract; 233 are open to participants now.
Browse Cataract studies →13 of the 62 studies in Cataract with a site in Spain are open now. Recruiting first, the newest first:
Carl Zeiss Meditec AG · Sites in Spain, Czechia, Germany and 1 more country
Ages 18+
Z Optics, Inc. · Sites in Spain, Portugal, Switzerland
Ages 40–75
AST Products, Inc. · Sites in Spain
Ages 40+
Alcon Research · Sites in Spain, United States, India and 1 more country
Ages 18+
OMIQ Research · Sites in Spain
Ages 50+
A study can be open while its sites in Spain have not opened yet or have stopped. Only those recruiting at a site in Spain →
Of the 142 Cataract studies recruiting now, 87 (61%) set no upper age limit and 8 (6%) stop at 75 or younger; 10 take children under 18; 14 take healthy volunteers.
This study: 50 Years and older · all sexes · healthy volunteers too.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
62 studies; the count open now beside each. This study's row is marked.
First in 2003; this study’s year is marked. 10 started in 2021.
By drug class, each counting the studies that test any of its medicines:
This study's enrollment of 188 is above the median of 79 across 1,096 interventional studies indexed under Cataract.
Median enrollment 100 across the 35 interventional studies, 60 across the 27 observational. Of the 47 that completed or were terminated, 4 (9%) have results posted.
This tab as a report to print or save as PDF → With an account.
50 of 62 have an industry lead sponsor. The 10 most frequent:
Cutting Edge SAS is the lead sponsor of 5 studies on the registry; 2 are open to participants now.
Cutting Edge SAS has 4 studies filed under Cataract — fewer than ten, so there is no comparison to draw.
3 of the studies in Cataract with a site in Spain that are under way reach primary completion within a year, 0 of them phase 3. Phase 3 first, then by date:
| Study | Primary completion |
|---|---|
| NCT07232615Biotech Healthcare Holding GmbhA Planned Study at Multiple Sites is Being Done to Compare the Results of Two Types of Trifocal Toric Intraocular Lenses Used in Cataract Surgery | 2026-12 |
| NCT06987474Alcon ResearchCapella Scientia Development Study | 2027-05 |
| NCT05955846Z Optics, Inc.Evaluation of Safety and Effectiveness of an IOL With a Virtual Aperture Optic | 2027-08 |
Add all 3 to your calendar (.ics) → With an account.
Among the 62 studies in Cataract with a site in Spain, from their registry updates:
This tab as a report to print or save as PDF → With an account.
The study will be a multicentric, prospective open-label ethics committee approved clinical study to investigate safety, visual outcomes, contrast sensitivity and rotational stability after bilateral implantation of Isatis TF IOL following cataract surgery.
This is a staged, multicentric, controlled, prospective, open-label clinical study whereby patients undergoing routine cataract surgery will have bilateral implantation of hydrophobic acrylic refractive trifocal intraocular lenses (Isatis TF) or the monofocal control device Isatis.
The investigational device, Control lens and all study products, including the devices used for the study examinations, will be used within the intended use specifications from the manufacturer. In addition, no invasive or other burdening examinations will occur for the patient.
The study will be carried out in up to five clinical centers in Spain.
The device under investigation is a hydrophobic acrylic trifocal intraocular lens (IOL) manufactured by the sponsor of this study. The trifocality of this investigational device is based on a purely refractive principle with the goal to provide additional near and intermediate visual acuity with low photic side effects. The IOLs will be implanted in the course of routine cataract surgery and will benefit to patients suffering from cataract development.
The control device (Isatis) is a hydrophobic acrylic monofocal intraocular lens to be implanted during cataract surgery. This control lens is CE approved and commercially available in Spain. Isatis monofocal lens is the parent lens of the device under investigation and both lenses share mechanical and material properties.
In total 180 patients will be recruited for this clinical study and undergo bilateral implantation of the Isatis TF intraocular lens or Isatis lens in a 2:1 ratio. Subjects participating in the trial will attend a total of maximum 11 study visits over a period of 11-13 months. Subjects would have the option for unscheduled visits if required medically.
Data analyses will be performed after the last patient finished the 120-180 days postoperative examination.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
In addition to above mentioned in- and exclusion criteria, subjects shall be discontinued when certain conditions are present at the time of surgery, including:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
A drug or device being studied in a clinical trial.
It may be new, or already approved and being studied for another use, dose or form. Criteria often leave out people who took part in another study of one within a recent period, commonly 30 days or five half-lives.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Investigational drug or device
A drug or device being studied in a clinical trial.
It may be new, or already approved and being studied for another use, dose or form. Criteria often leave out people who took part in another study of one within a recent period, commonly 30 days or five half-lives.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Experimental arm: Trifocal intraocular lens Isatis TF
Device: Implantation of trifocal IOL, Isatis TF (device under investigation)
Comparator arm: Monofocal intraocular lens Isatis
Device: Implantation of monofocal IOL, Isatis (control device)
Patients will be implanted with study IOL in both eyes
Patients will be implanted with Control IOL in both eyes
Primary Safety Endpoint: Rates of Adverse Events
The objective is to compare the SPE (Safety and Performance Endpoints) rates of the investigational product to reference data stated in the according ISO standard for posterior intraocular lenses (EN ISO 11979-7:2018) based on minimum 100 subjects.
Time frame: 120-180 days postoperative
Primary Performance Endpoint: Best Corrected Distance Visual Acuity
The primary performance endpoint is to show non inferiority of Isatis TF compared to the monofocal comparator in terms of best corrected distance visual acuity (CDVA) by means of statistical significance.
Time frame: 120-180 days postoperative
Secondary Safety Endpoint: Best Corrected Distance Visual Acuity compared to historical data
The objective is to compare best corrected distance visual acuities (CDVA) above defined thresholds of the investigational product to the normative data stated in the according ISO norm (EN ISO 11979-7:2018) for posterior chamber intraocular lenses.
Time frame: 120-180 days postoperative
Secondary Performance Endpoint: Distance Corrected Near Visual Acuity (DCNVA)
Secondary performance endpoint is to show a statistically significant increase between pre-and postoperative findings on monocular Distance Corrected Near Visual Acuity (DCNVA) under photopic light conditions on the first implanted eye.
Time frame: 120-180 days postoperative
Secondary Performance Endpoint: Distance Corrected Intermediate Visual Acuity (DCIVA)
Secondary performance endpoint is to show a statistically significant increase between pre-and postoperative findings on monocular Distance Corrected Intermediate Visual Acuity (DCIVA) under photopic light conditions on the first implanted eye.
Time frame: 120-180 days postoperative
Monocular Uncorrected Distance Visual Acuity (UDVA) under photopic light conditions
Monocular UDVA is measured with ETDRS charts placed in 4m distance according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions.
Time frame: Preoperative, 1-2 days postoperative; 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Binocular Uncorrected Distance Visual Acuity (UDVA) under photopic light conditions
Binocular UDVA is measured with ETDRS charts placed in 4m distance according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions.
Time frame: 120-180 days postoperative, 330-420 days postoperative
Monocular Corrected Distance Visual Acuity (CDVA) under photopic light conditions
Monocular CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions.
Time frame: Preoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Monocular Corrected Distance Visual Acuity (CDVA) under mesopic light conditions
Monocular CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2018. This assessment is done binocularly under mesopic light conditions.
Time frame: 120-180 days postoperative
Binocular Corrected Distance Visual Acuity (CDVA) under photopic light conditions
Binocular CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions.
Time frame: 120-180 days postoperative
Monocular Uncorrected Intermediate Visual Acuity (UIVA) under photopic light conditions
Monocular UIVA is measured with ETDRS charts placed in 66cm distance according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions.
Time frame: 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Binocular Uncorrected Intermediate Visual Acuity (UIVA) under photopic light conditions
Binocular UIVA is measured with ETDRS charts placed in 66cm distance according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions.
Time frame: 120-180 days postoperative, 330-420 days postoperative
Monocular Uncorrected Near Visual Acuity (UNVA) under photopic light conditions
Monocular UNVA is measured with ETDRS charts placed in 40cm distance according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions.
Time frame: 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Binocular Uncorrected Near Visual Acuity (UNVA) under photopic light conditions
Binocular UNVA is measured with ETDRS charts placed in 40cm distance according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions.
Time frame: 120-180 days postoperative, 330-420 days postoperative
Monocular Distance Corrected Intermediate Visual Acuity (DCIVA) under photopic light conditions
Monocular DCIVA is measured with ETDRS charts placed in 66cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions.
Time frame: Preoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Monocular Distance Corrected Intermediate Visual Acuity (DCIVA) under mesopic light conditions
Monocular DCIVA is measured with ETDRS charts placed in 66cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done binocularly under mesopic light conditions.
Time frame: 120-180 days postoperative
Binocular Distance Corrected Intermediate Visual Acuity (DCIVA) under photopic light conditions
Binocular DCIVA is measured with ETDRS charts placed in 66cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions.
Time frame: 120-180 days postoperative
Monocular Distance Corrected Near Visual Acuity (DCNVA) under photopic light conditions
Monocular DCNVA is measured with ETDRS charts placed in 40cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions.
Time frame: Preoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Monocular Distance Corrected Near Visual Acuity (DCNVA) under mesopic light conditions
Monocular DCNVA is measured with ETDRS charts placed in 40cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done binocularly under mesopic light conditions.
Time frame: 120-180 days postoperative
Binocular Distance Corrected Near Visual Acuity (DCNVA) under photopic light conditions
Binocular DCNVA is measured with ETDRS charts placed in 40cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions.
Time frame: 120-180 days postoperative
Manifest refraction
The manifest refraction is measured by means of a phoropter. The data contains values for sphere, cylinder and axis of cylinder according to ISO 11979-7:2018. This data will also be used to calculate the manifest refractive spherical equivalent (MRSE)
Time frame: Preoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Adjusted Mean Refractive Spherical Equivalent (MRSE)
The predictability of the postoperative manifest refraction will be evaluated using the absolute value of the adjusted MRSE calculated by the following formula: MRSEadjusted = MRSEpostop - MRSEtarget.
Time frame: 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Binocular Defocus Curve
To assess the visual acuity for different distances, defocus curves under photopic light conditions are measured. This test is performed with best distance corrected refraction and spherical additions ranging from -4.5 D to +2.0 D in 0.5 D steps. This examination is performed binocularly.
Time frame: 120-180 days postoperative
Binocular Contrast Sensitivity under photopic light conditions
Contrast Sensitivity under photopic light conditions using the standardized contrast sensitivity device CSV-1000 (VectorVision). This examination is performed binocularly.
Time frame: 120-180 days postoperative
Binocular Contrast Sensitivity under mesopic light conditions
Contrast Sensitivity under mesopic light conditions using the standardized contrast sensitivity device CSV-1000 (VectorVision). This examination is performed binocularly.
Time frame: 120-180 days postoperative
Binocular Contrast Sensitivity under photopic light conditions and using a glare source
Contrast Sensitivity under photopic light conditions with a glare source using the standardized contrast sensitivity device CSV-1000 (VectorVision). This examination is performed binocularly.
Time frame: 120-180 days postoperative
Binocular Contrast Sensitivity under mesopic light conditions and using a glare source
Contrast Sensitivity under mesopic light conditions with a glare source using the standardized contrast sensitivity device CSV-1000 (VectorVision). This examination is performed binocularly.
Time frame: 120-180 days postoperative
Patient reported outcomes - Quality of Vision questionnaire [McAlinden et al, 2010]
To assess the subjective perception of disturbances by photic phenomena, the validated and verified Quality of Vision (QoV) questionnaire will be used. This questionnaire is a linear-scaled 30-item instrument and is designed with 10 symptoms rated in each of three scales (frequency, severity, and bothersome). The QoV Questionnaire provides a QoV score in terms of symptom frequency, severity, and bothersome \[McAlinden et al, 2010\].
Time frame: preoperative, 120-180 days postoperative
Patient reported outcomes - Catquest-9SF 2011 questionnaire [Lundström et al, 2009]
To assess if difficulties in daily life occur due to impaired sight. This questionnaire is a 9-item Rasch-scaled instrument to assess subjective perception of visual impairment after surgery \[Lundström et al, 2009\].
Time frame: preoperative, 120-180 days postoperative
Patient reported outcomes - Patient-Reported Spectacle Independence Questionnaire (PRSIQ) [Morlock et al, 2017]
The PRSIQ is a patient-reported measure assessing spectacle independence following cataract surgery. The analyses conducted provide evidence for the use of the PRSIQ total score as a measure of spectacle independence \[Morlock et al, 2017\].
Time frame: preoperative, 120-180 days postoperative
Pupil Size under photopic light conditions
Photopic pupil diameters are measured with a ruler allowing for a precision of at least +/-0.5 mm. In addition to the measurement with a ruler, pupil diameters under photopic light conditions will be recorded from the preoperative Pentacam measurement. For the photopic pupil diameters, eye illumination should be identical to that used for photopic contrast sensitivity testing. Pupil measurements should only be made after the eye has had time to fully adapt to the testing conditions (at least 5 minutes). The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time frame: preoperative, 120-180 days postoperative
Pupil Size under mesopic light conditions
Mesopic pupil diameters are measured with a ruler allowing for a precision of at least +/-0.5 mm. For the mesopic pupil diameters, eye illumination should be identical to that used for mesopic contrast sensitivity testing. Pupil measurements should only be made after the eye has had time to fully adapt to the testing conditions (at least 5 minutes). The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time frame: preoperative, 120-180 days postoperative
Fundus examination with dilated pupil
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • Fundus
Time frame: preoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Slitlamp examination - Corneal status
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • Corneal Status
Time frame: Preoperative, 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Slitlamp examination - Iris status
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • Iris Status
Time frame: Preoperative, 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Slitlamp examination - Signs of inflammation
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: * Signs of inflammation * Anterior chamber cells, * Anterior chamber flare, * Cystoid macular oedema, * Hypopyon, and * Endophthalmitis.
Time frame: Preoperative, 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Slitlamp examination - Pupillary block
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: - Pupillary block.
Time frame: 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Slitlamp examination - Retinal detachment
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: - Retinal detachment.
Time frame: preoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Slitlamp examination - Status of anterior and posterior capsule
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: - Status of anterior and posterior capsule.
Time frame: 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Slitlamp examination - IOL decentration
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: - IOL decentration.
Time frame: 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Slitlamp examination - IOL tilt
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: - IOL tilt.
Time frame: 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Slitlamp examination - IOL discoloration
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: - IOL discoloration.
Time frame: 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Slitlamp examination - IOL opacity
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: - IOL opacity.
Time frame: 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Intraocular pressure (IOP) measurement
The IOP will be measured with non-contact tonometer as part of the routine follow up examinations. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time frame: Preoperative, 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Keratometry
Keratometric measurements are performed to calculate the required IOL power. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time frame: Preoperative
IOL power and target refraction
The parameter of the implanted IOL must be recorded as well as the target refraction given by the IOL calculator. This parameter is needed to calculate the accuracy of achieving the target refraction. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time frame: day of surgery
Fundus OCT
An OCT (optical coherence tomography) image will be taken at the preoperative visit to identify AMD suspicious eyes that need to be excluded from this study. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time frame: Preoperative
Biometry
Biometry measurements are performed to calculate the required IOL power. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time frame: Preoperative
Corneal topography
Pentacam device (Oculus, Germany) will be used to perform corneal topography. This examination is needed to exclude patients showing an irregular corneal astigmatism.
Time frame: Preoperative
Corneal aberrometry
Pentacam device (Oculus, Germany) will be used to perform corneal aberrometry measurement. The following values will be evaluated in this study: Spherical aberrations, high order aberrations.
Time frame: Preoperative
IOL rotation
To determine the rotational stability of the lenses after implantation, the actual IOL orientation has to be recorded as the intended surgical position during surgery using a photograph through the surgery microscope or within one hour after surgery using a photograph through a slit lamp to document the rotational position of the IOL. Additional orientations are measured and recorded at the follow up visits by taking retroilluminated photographs in mydriasis using the slit lamp. To determine the rotational stability, it is important that the IOL axis marks of the IOL are visible as well as concurrent structures of the eye (in the same image) that are fixed and stable. Preferred fixed structures are limbal vessels. The pupil is dilated if necessary to visualize the IOL axis marks.
Time frame: day of surgery, 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Halo and glare scores
A Halo and Glare simulator software (Eyeland Design Network GmbH, Germany) will be used to assess the subjective perception of photic phenomena. The patients will be asked to adjust the halo and glare level in a simulated image to the amount they perceive of such photic phenomena. This test is performed pre- and postoperatively. The preoperative outcomes serve as a baseline measurement.
Time frame: Preoperative, 120-180 days postoperative, 330-420 days postoperative
Plan to share: No
Ran from May 2021 to primary completion in Jun 2024, 36 months.
Of 190 industry-sponsored interventional studies with no phase under Cataract, half reached primary completion within 16 months of starting (the median), counting those still running; a quarter within 10 and three quarters within 28. This study's 36 months is above that.
Counting every sponsor, half of 496 studies reached it within 17 months; a quarter within 9 and three quarters within 29.
How these figures are worked out, and which studies are left out of them.
This study is completed, as verified in Sep 2024. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Cutting Edge SAS