An interventional study of PEEP by Best oxygenation and PEEP by Best Compliance in ARDS, sponsored by Wolfson Medical Center. Status unknown at 1 site in Israel. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2012-12-05.
Sponsored by Wolfson Medical Center · Not applicable, Interventional, and Treatment
To compare the best Positive End Expiratory Pressure (PEEP) as determined by one of three commonly used clinical approaches for best PEEP determination, with PEEP guided by the ARDS network algorithm.
The determination of optimal level of Positive End Expiratory Pressure (PEEP) in patients with acute hypoxemic respiratory pressure remains elusive and controversial.
Several approaches with different algorithms exist. Among them, Low PEEP algorithm approach and High PEEP algorithm approach. These approaches are characterized by a generalized application of certain level of PEEP according to a predefined algorithm. However, these algorithms fail to account for inter-individual variations between patients with different diseases and with different severities of the same underlying process. Therefore, we advocate for an individualized application of PEEP. Whereby, PEEP will be determined individually for each patient based on familiar and well established physiological parameters.
1,597 studies on the registry are indexed under Respiratory Distress Syndrome; 312 are open to participants now.
This study's planned enrollment of 20 is below the median of 60 across 961 interventional studies indexed under Respiratory Distress Syndrome.
Browse Respiratory Distress Syndrome studies →Wolfson Medical Center is the lead sponsor of 113 studies on the registry; 16 are open to participants now.
Counted across the registry records on this site, refreshed daily.
20 Man and women older than 18 years will be recruited. Patients with acute respiratory failure of any cause who are mechanically ventilated according to the ARDS network recommendations will be considered for inclusion to the study.
To be included in the study a prerequisite of high peak Inspiratory pressure (plateau pressure of 25 to 30 cmH2O) has to be present, and at least one of the following four severity inclusion criteria has to be met.
1 - Low Total Respiratory system compliance (CT), defined as less than 50ml/cmH2O. 2 - PaO2 /FIO2 ratio of less than 300. 3 - Need for a PEEP greater than 10 cmH2O to maintain arterial oxygen saturation (SaO2) of > 90%.
4 - carbon dioxide partial pressure (PCO2) over 60 mmHg, or PH less than 7.2 that is attributed to respiratory acidosis.
Exclusion Criteria:
Patients with any of the following will be excluded from the study. Previous lung or chest wall surgery, previous esophageal surgery, known Achalasia or any other esophageal motility or spasm disorder, presence of chest thoracostomy tube, and any significant chest wall abnormality such as kyphoscoliosis.
Set Positive End Expiratory Pressure (PEEP) at 25 cmH2O with fixed driving pressure that will result in delivery of a fixed Tidal Volume (TV) of 6ml/kg Ideal Body Weight (IBW). fraction of inspired oxygen (FiO2) is set to 60%. Then decrease PEEP in steps of 4 cmH2O every 10 min until PEEP of 5 cm H2O is reached. In each step static compliance of respiratory system and lung compliance will be measured along with arterial blood gas (ABGs), and hemodynamic parameters such as cardiac output and mixed venous O2 saturation. Best or optimal PEEP will be defined as the PEEP below which PaO2 /FIO2 falls by at least 20%. If at least 20% Partial Oxygen tension (PaO2) PaO2 /FIO2 decrement is not obtained, then PEEP that will result in the highest PaO2 will be selected.
Other: PEEP by Best oxygenation · Other: PEEP by Best Compliance · Other: PEEP by Esophageal pressure
In this group assessment begins with measuring intrinsic PEEP by an expiratory hold. Thereafter, plateau pressures will be recorded after a 0.5-sec inspiratory pause. Applied PEEP will be increased by steps of 4 cm H2O, after each incremental step the patient will be observed for 10 minutes to allow for lung unit recruitment and equilibration. Plateau pressure will be measured after each incremental step of PEEP. Applied PEEP will be increased sequentially by 4 cm H2O increments until peak inspiratory pressure of 50 cm H2O, or plateau pressure of 40 cm H2O reached, or hypotension or decrease of 20% in cardiac output is observed.
Other: PEEP by Best oxygenation · Other: PEEP by Best Compliance · Other: PEEP by Esophageal pressure
Upon patient recruitment Esophageal balloon will be inserted and esophageal / pleural pressure will be measured. Thereafter, Inspiratory pressures and PEEP will be adjusted according to well established criteria. Inspiratory pressure and PEEP will be adjusted to achieve the best lung compliance possible while not exceeding transpulmonary end Inspiratory pressure of 25 to 30 cm H2O, and at the same time maintaining a positive transpulmonary end expiratory pressure of not more than 5 cm H2O.
Other: PEEP by Best oxygenation · Other: PEEP by Best Compliance · Other: PEEP by Esophageal pressure
Set PEEP at 25 cmH2O with fixed driving pressure that will result in delivery of a fixed Tidal Volume (TV) of 6ml/kg (IBW). FiO2 is set to 60%. Then decrease PEEP in steps of 4 cmH2O every 10 min until PEEP of 5 cm H2O is reached. In each step static compliance of respiratory system and lung compliance will be measured along with ABGs, and hemodynamic parameters such as cardiac output and mixed venous O2 saturation. Best or optimal PEEP will be defined as the PEEP below which PaO2 /FIO2 falls by at least 20%. If at least 20% PaO2 /FIO2 decrement is not obtained, then PEEP that will result in the highest PaO2 will be selected.
Also known as: PEEP determined by Best oxygenation approach.
In this group assessment begins with measuring intrinsic PEEP by an expiratory hold. Thereafter, plateau pressures will be recorded after a 0.5-sec inspiratory pause. Applied PEEP will be increased by steps of 4 cm H2O, after each incremental step the patient will be observed for 10 minutes to allow for lung unit recruitment and equilibration. Plateau pressure will be measured after each incremental step of PEEP. Applied PEEP will be increased sequentially by 4 cm H2O increments until peak inspiratory pressure of 50 cm H2O, or plateau pressure of 40 cm H2O reached, or hypotension or decrease of 20% in cardiac output is observed.
Upon patient recruitment Esophageal balloon will be inserted and esophageal / pleural pressure will be measured. Thereafter, Inspiratory pressures and PEEP will be adjusted according to well established criteria. Inspiratory pressure and PEEP will be adjusted to achieve the best lung compliance possible while not exceeding transpulmonary end Inspiratory pressure of 25 to 30 cm H2O, and at the same time maintaining a positive transpulmonary end expiratory pressure of not more than 5 cm H2O.
Oxygenation (defined by partial O2 pressure divided by Fractional inspired Oxygen tension or P/F ratio)
oxygenation (defined by partial O2 pressure divided by Fractional inspired Oxygen tension or P/F ratio)
Time frame: 2 hours
Lung compliance (defined by Tidal Volume divided by Inspiratory transpulmonary pressure)
Lung compliance (defined by Tidal Volume divided by Inspiratory transpulmonary pressure)
Time frame: 2 hours
This study is status unknown, as verified in Oct 2012. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Respiratory Distress Syndrome→
Wolfson Medical Center