An interventional study of Dynamic Urine Vibration "Holter" in Bladder Outlet Obstruction, sponsored by Meir Medical Center. Status unknown at 1 site in Israel. Open to male participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2011-07-06.
Sponsored by Meir Medical Center · Not applicable, Interventional, and Diagnostic
Current gold standard of bladder outlet diagnosis is pressure flow study. This study is invasive time consuming and requires expensive and complex set-up. In this study the investigators plan to evaluate an alternative technology that presumably is able to diagnose bladder outlet obstruction using a Dynamic Urine Vibration "Holter" based on a Urine Flow Vibration Analysis technology. The acoustic vibration sensor is a small device that records the vibration due to urine flow. The patient attaches the sensor to the penis using a disposable sensor patch for the duration of approximately one minute during one urination. The analysis is performed off-line and the results are compared to the results of a standard pressure flow study. The innovative technology for the diagnosis of bladder outlet obstruction is noninvasive, rapid and does not involve complex setup.
46 studies on the registry are indexed under Urinary Bladder Neck Obstruction; 10 are open to participants now.
This study's planned enrollment of 100 is above the median of 88 across 30 interventional studies indexed under Urinary Bladder Neck Obstruction.
Browse Urinary Bladder Neck Obstruction studies →Meir Medical Center is the lead sponsor of 401 studies on the registry; 26 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Inclusion Criteria:
each subject will undergo intervention for the diagnosis of bladder outlet obstruction first using the Dynamic Urine Vibration "Holter" and then urodynamically by pressure flow study
Device: Dynamic Urine Vibration "Holter"
each subject will undergo intervention for the diagnosis of bladder outlet obstruction first using the Dynamic Urine Vibration "Holter" and then urodynamically by pressure flow study
Efficacy of Holter to confirm or exclude of bladder outlet obstruction
Time frame: one recording at the time of urodynamic testing.approximatly one minute
This study is status unknown, as verified in Jul 2011. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Urinary Bladder Neck Obstruction →