ClinicalTrials.gg
Status unknownNCT00641290Updated Apr 15, 2008

Vigileo FloTrac vs Pulmonary Artery Catheter

An observational study in Ischemic Heart Disease and Valvular Heart Disease, sponsored by Hospital Sultanah Aminah Johor Bahru. Status unknown at 1 site in Malaysia. Per ClinicalTrials.gov, last updated 2008-04-15.

Sponsored by Hospital Sultanah Aminah Johor Bahru · Observational

How we know

The sponsor has not verified this record recently (last verified Apr 2008), so the status shown — last known as Not yet recruiting — may be out of date.

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Study type
Observational
Enrollment
60
Sex
All
01

Where this study stands

Counted across the records on this site · 2026-11-21

Among 12 studies in Myocardial Ischemia with a site in Malaysia — none open to participants now, 3 under way, none of them phase 3. Myocardial Ischemia · Malaysia.

Started
2008
with 1 other
Observational
4 of 12
none open now
Registered
3rd of 12
by date
Lead sponsor
1 of 12
Hospital Sultanah Aminah Johor Bahru

Among the 12 studies in Myocardial Ischemia with a site in Malaysia, this one is one of 2 that started in 2008, is one of 4 observational ones, and was the 3rd registered.

Myocardial Ischemia

1,123 studies on the registry are indexed under Myocardial Ischemia; 177 are open to participants now.

Browse Myocardial Ischemia studies →

Open to participants now

None of the 12 studies in Myocardial Ischemia with a site in Malaysia is open now. The open studies under Myocardial Ischemia, anywhere →

Who these studies take

Of the 135 Myocardial Ischemia studies recruiting now, 92 (68%) set no upper age limit and 6 (4%) stop at 75 or younger; 14 take children under 18; 20 take healthy volunteers.

This study: all sexes · no healthy volunteers.

The full table on the hub →

This tab as a report to print or save as PDF → With an account.

Was this useful?
Download CSVNarrow it in search →With an account: the 12 studies in Myocardial Ischemia with a site in Malaysia as a file.
02

Study summary

To study the role of Vigileo monitor using the FloTrac sensor to measure cardiac output using the pulse contour analysis as well as central venous oxygen saturation monitoring as a guide for tissue perfusion. The accuracy of the Vigileo monitoring was compared with the conventional thermodilution method for measuring cardiac output using the pulmonary artery catheter and mixed venous oxygen saturation for assessing global tissue perfusion.

Read the detailed description

Cardiac Output and Central Venous Oxygen Saturation Monitoring Using the Vigileo FloTrac Sensor Versus Conventional Thermodilution Method Using the Pulmonary Artery Catheter: A Prospective Study

OBJECTIVE: To study the role of Vigileo monitor using the FloTrac sensor to measure cardiac output using the pulse contour analysis as well as central venous oxygen saturation monitoring as a guide for tissue perfusion. The accuracy of the Vigileo monitoring was compared with the conventional thermodilution method for measuring cardiac output using the pulmonary artery catheter and mixed venous oxygen saturation for assessing global tissue perfusion.

DESIGN: A prospective clinical study conducted at the cardiothoracic operating theatre and the cardiothoracic intensive care unit of Sultanah Aminah Hospital Johor Bahru.

PARTICIPANTS: 60 patients from the time of induction of anaesthesia to post operative Day 1 in the cardiothoracic intensive care unit.

INTERVENTIONS: Simultaneous cardiac output measurements using the Vigileo FloTrac sensor and thermodilution method using the PAC will be obtained at the following intervals: Post Induction( T0), Pre CPB( T1), Post CPB( T2), 1 hour post ICU admission( T3), 4 hours post ICU admission( T4), 1 hour post extubation( T5) and post operative Day 1 at 0700(T6). Central venous oxygen saturation measurements and mixed venous oxygen saturation using the PAC was also obtained at similar interval times as above. Low central venous oxygen saturation is defined as less than 70% while low mixed venous oxygen saturation was fixed as less than 65% for appropriate interventions to be instituted to improve oxygen delivery. Arterial blood gases will also be done at the scheduled interval to validate whether the presence of metabolic acidosis can be used to correlate with central or mixed venous oxygen saturation measurements.

MEASUREMENTS AND RESULTS: Demographic data that was recorded include age, sex, body weight, height, and body mass index, type of surgery, ejection fraction, time on cardiopulmonary bypass, Euroscore, haemoglobin and haematocrit levels.

At the scheduled interval, cardiac output measurements using the thermodilution method as well as the pulse contour analysis method using the Vigileo FloTrac system will be done. Mixed venous oxygen (SvO2) will be sampled simultaneously with the central venous oxygen saturation (ScvO2 ).

Demographic data will be summarized as mean ± SD where appropriate. Bland -Altman plot will be done to compare both methods for obtaining the cardiac output measurements. Linear regression analysis, Bland-Altman plot and Pearson test will be used to evaluate the correlation between SvO2 and ScvO2. A p-value of \< 0.05 will be considered as significant.

EXCLUSION CRITERIA: Patients will be excluded if they are on Intra Aortic Balloon Pump (IABP), requiring emergency chest reopening, significant arrhythmia which causes an irregular arterial waveform and tricuspid regurgitation as ruled out during the pre operative echocardiogram.

03

Conditions studied

  • Ischemic Heart Disease
  • Valvular Heart Disease

Keywords

  • CABG
  • Valve surgery
04

Who can participate

Ages eligible
Child (0–17), Adult (18–64), Older adult (65+)
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • All patients who are undergoing coronary bypass graft surgery and valvular heart disease.

Exclusion criteria

Exclusion Criteria:

  • Patients will be excluded if they are on Intra Aortic Balloon Pump (IABP), requiring emergency chest reopening, significant arrhythmia which causes an irregular arterial waveform and tricuspid regurgitation as ruled out during the pre operative echocardiogram.
05

Study design

Enrollment
60 participants (estimated)

Interventions

  • DeviceVigileo FloTrac Sensor

    Comparing the Vigileo FloTrac against the conventional Pulmonary Artery Catheter using the thermodilution method for measurements of cardiac output.

06

What researchers measure

Primary outcomes

  1. Cardiac output and other haemodynamic indices

    Time frame: 48 hours

07

Study locations

1 site
  • Hospital Sultanah Aminah
    Johor Bahru, Johor 80100, Malaysia
    • Gunalan P Arumugam, MBBS · Principal investigator
    • Raha M. Daud, MD · Sub investigator
    • Zanariah Sabiron, MD · Sub investigator
    • Salamah Azerai, MD · Sub investigator
    • Subrahmanyam Balan, MBBS · Sub investigator
08

Timeline

Tracking since Sep 25, 2026
Not marked actual or estimatedDates not marked actual or estimated

The record gives a start of Apr 2008, a primary completion of Aug 2008 and a completion of Aug 2008. It does not say whether these dates are actual or estimated.

How these figures are worked out, and which studies are left out of them.

Registered
Mar 17, 2008
First posted
Mar 24, 2008
Start
Apr 2008
Primary completionEst.
Aug 2008
CompletionEst.
Aug 2008
Last update
Apr 15, 2008
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Apr 15, 2008, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
09

Registry details

Key details

Study ID
NCT00641290
Lead sponsor
Hospital Sultanah Aminah Johor Bahru
First posted
Mar 24, 2008
Start date
Apr 2008
Primary completion
Aug 2008 (estimated)
Completion
Aug 2008 (estimated)
Last update
Apr 15, 2008

Study contacts

Gunalan P Arumugam, MBBS
Contact
gunalan73@yahoo.com
0060122057474
Subrahmanyam Balan, MBBS
study chair · Hospital Sultanah Aminah Johor Bahru

Oversight

Data monitoring committee
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is status unknown, as verified in Apr 2008. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion