An interventional study of HFT750 with Automated FiO2 Control (TSF ON) and HFT750 with Manual FiO2 Control (TSF OFF) in Respiratory Insufficiency, Hypoxemia and Oxygen Inhalation Therapy, sponsored by MEKICS Co., Ltd.. Enrolling by invitation at 2 sites in South Korea. Open to participants aged 28 Days to 1 Year. Per ClinicalTrials.gov, last updated 2026-11-23.
Sponsored by MEKICS Co., Ltd. · Not applicable, Interventional, and Treatment
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 10 studies in Respiratory Insufficiency with a site in Korea, Republic of — 3 open to participants now, 3 under way, none of them phase 3. Respiratory Insufficiency · Korea, Republic of.
Among the 10 studies in Respiratory Insufficiency with a site in Korea, Republic of, this one is one of 2 that started in 2026, is one of 7 with no phase, and was the 10th registered.
1,372 studies on the registry are indexed under Respiratory Insufficiency; 266 are open to participants now.
Browse Respiratory Insufficiency studies →3 of the 10 studies in Respiratory Insufficiency with a site in Korea, Republic of are open now. Recruiting first, the newest first:
Uijeongbu St. Mary Hospital · Sites in Korea, Republic of
Ages 19+
Wonju Severance Christian Hospital · Sites in Korea, Republic of
Ages 40+
A study can be open while its sites in Korea, Republic of have not opened yet or have stopped. Only those recruiting at a site in Korea, Republic of →
Of the 180 Respiratory Insufficiency studies recruiting now, 135 (75%) set no upper age limit and 18 (10%) stop at 75 or younger; 21 take children under 18; 20 take healthy volunteers.
This study: 28 Days to 1 Year · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
10 studies; the count open now beside each. This study's row is marked.
First in 2010; this study’s year is marked. 2 started in 2026.
By drug class, each counting the studies that test any of its medicines:
This study's planned enrollment of 20 is below the median of 60 across 861 interventional studies indexed under Respiratory Insufficiency.
Median enrollment 74 across the 9 interventional studies, 100 across the 1 observational. Of the 2 that completed or were terminated, 0 (0%) have results posted.
This tab as a report to print or save as PDF → With an account.
1 of 10 have an industry lead sponsor. The 8 most frequent:
This is the only study on the registry with MEKICS Co., Ltd. as lead sponsor.
MEKICS Co., Ltd. has 1 study filed under Respiratory Insufficiency — fewer than ten, so there is no comparison to draw.
None of the studies under way reaches primary completion within a year.
Among the 10 studies in Respiratory Insufficiency with a site in Korea, Republic of, from their registry updates:
This tab as a report to print or save as PDF → With an account.
The purpose of this study is to evaluate the safety and effectiveness of the automated oxygen control function, called Target SpO2 Feedback control by FiO2 (TSF), in the HFT750 high-flow nasal cannula (HFNC) device for infants admitted to the neonatal intensive care unit (NICU). Maintaining optimal blood oxygen saturation (SpO2) within the target range of 90% to 95% is critical for infants receiving respiratory support, as both too little oxygen (hypoxia) and too much oxygen (hyperoxia) can cause serious complications. Currently, healthcare providers manually adjust the fraction of inspired oxygen (FiO2), which can be challenging due to rapid changes in an infant's breathing. In this crossover study, eligible infants aged 28 days to 1 year requiring HFNC therapy will be randomly assigned to receive both automated FiO2 control (TSF function ON) and standard manual FiO2 control (TSF function OFF) in one of two sequences. Each control mode will be applied for 6 hours, separated by a 30-minute wash-out period, for a total device application time of 12 hours and 30 minutes. Researchers will compare the occurrence of composite safety events (severe hypoxia, severe hyperoxia, or need for urgent medical intervention) and the percentage of time spent within the target SpO2 range between the two modes.
This is a prospective, randomized, crossover, single-blind, multicenter, sponsor-initiated exploratory clinical trial comparing automated FiO2 adjustment (TSF ON) versus manual FiO2 adjustment (TSF OFF) using the HFT750 universal ventilator (MEKICS Co., Ltd.) in infants requiring high-flow nasal cannula (HFNC) therapy.
Intervention Mechanism and Settings:
The TSF algorithm in the HFT750 continuously monitors the patient's SpO2 via an integrated pulse oximeter module every second and automatically adjusts the delivered FiO2 to maintain the target SpO2 range of 90-95%:
During both automated and manual periods, the upper FiO2 limit is restricted to baseline FiO2 + 0.2 (maximum 0.5). During the TSF ON period, healthcare providers do not manually intervene in FiO2 adjustments except in emergency situations such as bradycardia or apnea.
Study Procedure:
A total of 20 infants will be stratified by gestational age (\<32 weeks vs. ≥32 weeks) and randomized in a 1:1 ratio into Group A (TSF ON followed by TSF OFF) or Group B (TSF OFF followed by TSF ON). Data from the first 30 minutes after switching modes (wash-out period) will be excluded from analysis to prevent carryover effects. Participants will be followed up until the completion of their first feeding immediately following the 12.5-hour device application period.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Participants receive automated FiO2 adjustment (TSF function ON) via the HFT750 device for 6 hours, followed by a 30-minute wash-out period, and then receive manual FiO2 adjustment (TSF function OFF) by healthcare providers for 6 hours.
Device: HFT750 with Automated FiO2 Control (TSF ON) · Device: HFT750 with Manual FiO2 Control (TSF OFF)
Participants receive standard manual FiO2 adjustment (TSF function OFF) by healthcare providers via the HFT750 device for 6 hours, followed by a 30-minute wash-out period, and then receive automated FiO2 adjustment (TSF function ON) for 6 hours.
Device: HFT750 with Automated FiO2 Control (TSF ON) · Device: HFT750 with Manual FiO2 Control (TSF OFF)
Automated FiO2 adjustment using the Target SpO2 Feedback (TSF) algorithm on the HFT750 universal ventilator to maintain target SpO2 between 90% and 95% (FiO2 increases by 1% every 10-20 sec if SpO2 \<90%; decreases by 1% every 30-120 sec if SpO2 \>95%; FiO2 limit = baseline + 0.2, max 0.5) for 6 hours.
Standard manual FiO2 adjustment by healthcare providers using the HFT750 universal ventilator with the TSF function turned OFF to maintain target SpO2 between 90% and 95% (FiO2 limit = baseline + 0.2, max 0.5) for 6 hours.
Incidence of Composite Safety Events
Number of participants experiencing at least one composite safety event, defined as: (1) severe hypoxemia (SpO2 \<85% lasting \>60 seconds), (2) severe hyperoxemia (SpO2 \>98% lasting \>60 seconds while FiO2 \>0.21), or (3) requirement for urgent medical intervention (manual FiO2 override due to bradycardia/apnea, or escalation to noninvasive/invasive mechanical ventilation)
Time frame: During each 6-hour intervention period (excluding the first 30-minute wash-out period after mode switching), up to 12.5 hours of total device application
Percentage of Time Spent Within the Target SpO2 Range (90% to 95%)
Proportion of total valid recording time during which peripheral oxygen saturation (SpO2) is maintained within the target range of 90% to 95%.
Time frame: During each 6-hour intervention period (excluding the first 30-minute wash-out period after mode switching), up to 12.5 hours of total device application
Percentage of Time Spent in Hypoxemia (SpO2 <90%) and Hyperoxemia (SpO2 >95%)
Proportion of total valid recording time spent below the target range (SpO2 \<90%, and severe hypoxemia \<85%) and above the target range (SpO2 \>95% while FiO2 \>0.21, and severe hyperoxemia \>98%).
Time frame: During each 6-hour intervention period (excluding the first 30-minute wash-out period after mode switching), up to 12.5 hours of total device application
Frequency of Manual FiO2 Adjustments and Signs of Respiratory Distress
Number of manual FiO2 adjustments performed by healthcare providers, mean delivered FiO2, and clinical assessment of respiratory distress signs (such as tachypnea, chest wall retractions, or nasal flaring) and feeding tolerance.
Time frame: During each 6-hour intervention period and up to the completion of the first feeding immediately following the 12.5-hour device application period
Incidence of Adverse Events (AEs) and Adverse Device Effects (ADEs)
Number and severity of all adverse events, serious adverse events (SAEs), and device-related adverse effects (e.g., nasal mucosal irritation, device malfunction) observed during the study.
Time frame: From the start of device application until the completion of the first feeding immediately following the 12.5-hour device application period
Plan to share: No
No publications or documents are linked to this record.
Started Aug 2026 (actual). Primary completion is estimated for Dec 2027, 16 months after the start.
Of 376 interventional studies with no phase under Respiratory Insufficiency, half reached primary completion within 24 months of starting (the median), counting those still running; a quarter within 10 and three quarters within 46. This study's planned 16 months is below that.
How these figures are worked out, and which studies are left out of them.
From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗
Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.
No contact was published for this record. The registry link below has the sponsor’s details.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.