BIO|STREAM.CSP CLS

An observational study in Sinus Node Disease and Atrioventricular Block, sponsored by Biotronik SE & Co. KG. Recruiting at 12 sites in 5 countries. Open to participants aged 18 Years to 18 Years. Per ClinicalTrials.gov, last updated 2026-07-17.

Sponsored by Biotronik SE & Co. KG · Observational

From the registry’s dates

  • Started May 2026; still recruiting 5 months later.
Study type
Observational
Model
Case-only
Time perspective
Prospective
Enrollment
150
Ages
18 Years to 18 Years
Sex
All
01

Study summary

This clinical study is a prospective, observational submodule of the BIO\|STREAM.CSP registry designed to evaluate clinical outcomes in patients receiving BIOTRONIK dual-chamber pacemakers that combine conduction system pacing-specifically left bundle branch area pacing (LBBAP)-with Closed Loop Stimulation (CLS). The purpose of the study is to better understand how this combined pacing strategy performs in routine clinical practice and whether it may help reduce the occurrence of atrial fibrillation in patients with sinus node dysfunction (SND) and concomitant atrioventricular (AV) conduction disorders.

The primary question the study seeks to answer is what the incidence of device-detected atrial fibrillation (DDAF) is over a 24-month follow-up period in patients treated with LBBAP and active CLS. Additionally, the study explores how CLS dynamically modulates pacing rates when the ventricular lead is positioned within the conduction system, and whether this physiological pacing approach may mitigate the negative effects associated with conventional right ventricular pacing.

Overall, this study aims to generate real-world evidence to support optimization of pacemaker programming and to inform clinical decision-making regarding the use of CLS in combination with conduction system pacing, with the goal of improving patient outcomes and reducing atrial arrhythmia burden.

Read the detailed description

This study, BIO\|STREAM.CSP CLS, is a prospective, observational submodule of the ongoing BIO\|STREAM.CSP registry. It is designed to collect real-world clinical data from patients who receive BIOTRONIK dual-chamber pacemakers using conduction system pacing (CSP), with a specific focus on the combination of left bundle branch area pacing (LBBAP) and Closed Loop Stimulation (CLS).

Permanent cardiac pacing is a standard therapy for patients with sinus node dysfunction (SND), a condition in which the heart's natural pacemaker does not function properly. A considerable proportion of these patients also have atrioventricular (AV) conduction disorders, which impair the electrical connection between the atria and ventricles. In such cases, dual-chamber pacemakers are typically implanted to maintain appropriate heart rhythm and coordination.

Traditional right ventricular (RV) pacing, while effective in maintaining heart rate, has been associated with non-physiological activation of the heart and may contribute to an increased risk of atrial fibrillation (AF), especially when pacing burden is high. Device-detected atrial fibrillation (DDAF) is a clinically relevant outcome, as it is associated with increased risk of stroke, heart failure, and other cardiovascular complications.

Closed Loop Stimulation (CLS) is an advanced pacemaker feature designed to provide more physiological heart rate adaptation by continuously monitoring cardiac contractility and adjusting the pacing rate accordingly. In previous studies, including the B3 trial, CLS demonstrated a reduction in DDAF incidence in patients with SND. However, this benefit was not observed in patients with AV block, likely due to the adverse effects of frequent RV pacing.

Conduction system pacing, and in particular left bundle branch area pacing (LBBAP), is an emerging pacing strategy that stimulates the heart's intrinsic conduction pathways, resulting in a more physiological and synchronized ventricular activation. This approach has the potential to reduce the negative effects associated with RV pacing.

The BIO\|STREAM.CSP CLS submodule aims to investigate whether the combination of LBBAP and CLS can reduce the incidence of DDAF in patients with both SND and AV conduction disorders in routine clinical practice. The study will follow approximately 150 patients over a 24-month period after pacemaker implantation. Patients included are those enrolled in the BIO\|STREAM.CSP registry who receive a de novo dual-chamber pacemaker with activated CLS and LBBAP, and who have no prior history of atrial fibrillation.

The primary objective of this exploratory submodule is to assess the incidence and timing of DDAF episodes following activation of CLS, using device-based diagnostics over the follow-up period. The study will evaluate multiple thresholds of AF episode duration (e.g., ≥6 minutes, ≥6 hours, ≥24 hours, and ≥7 days), as well as the time to first occurrence and overall AF burden. Secondary analyses will explore how CLS modulates heart rate in patients with conduction system pacing, including the distribution of paced and sensed heart rates over time.

As an observational study without a control group, BIO\|STREAM.CSP CLS is intended to generate hypothesis-generating, real-world evidence rather than to test a predefined hypothesis. The findings are expected to provide insights into the clinical performance of CLS in combination with LBBAP and to support optimization of device programming strategies.

Overall, this study seeks to improve understanding of how advanced pacing technologies can be used together to deliver more physiological cardiac pacing, with the goal of reducing atrial arrhythmias and improving long-term outcomes in patients requiring permanent pacemakers.

02

Conditions studied

  • Sinus Node Disease
  • Atrioventricular Block

Keywords

  • Conduction system pacing
  • Closed loop stimulation
  • Dual-chamber pacemaker
  • Left bundle branch area pacing
03

In context

Sick Sinus Syndrome

93 studies on the registry are indexed under Sick Sinus Syndrome; 18 are open to participants now.

This study's planned enrollment of 150 is below the median of 300 across 29 observational studies indexed under Sick Sinus Syndrome.

Browse Sick Sinus Syndrome studies →

Lead sponsor

Biotronik SE & Co. KG is the lead sponsor of 83 studies on the registry; 6 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years to 18 Years
Sexes eligible
All
Accepts healthy volunteers
No
Sampling method
Non-probability sample

Study population

Patients with an indication for de novo dual-chamber pacing due to SND with evidence of AV conduction disorders, enrolled in the BIO\|STREAM.CSP registry.

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Enrolled in the BIO\|STREAM.CSP registry
  • Standard indication for dual-chamber pacing due to any form of sinus node disease according to guidelines
  • DDD-CLS pacing mode activated
  • Either ≥ II degree AV block, or native PR interval ≥ 200 ms at baseline with expected RVP ≥ 20%

Exclusion criteria

Exclusion Criteria:

  • Implantation dates back more than 90 days
  • History of clinical AF
  • Patients intended to receive, or already received a pacing lead for traditional RV pacing, His bundle pacing or right bundle branch pacing
  • Upgrade from previous pacemaker system
  • Patients transitioning from the BIO\|MASTER.CSP study
  • DDAF episodes present in the device memory at the time of registration
Terms in these criteria, in plain language(1)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

ECG (electrocardiogram)

A recording of the heart’s electrical activity, taken with stickers on the chest, arms and legs. It takes a few minutes and does not hurt.

05

Study design

Observational model
Case-only
Time perspective
Prospective
Enrollment
150 participants (estimated)
Target follow-up
24 Months
Patient registry
Yes

Interventions

  • DeviceLeft bundle branch area pacing with Closed Loop Stimulation

    Permanent dual-chamber cardiac pacing with ventricular lead placement in the left bundle branch area and activation of the Closed Loop Stimulation (CLS) rate-responsive algorithm.

06

What researchers measure

Primary outcomes

  1. DDAF incidence

    Time from CLS activation to the first device-detected atrial fibrillation (DDAF) episode of different duration cutoffs (6 minutes, 6 hours, 24 hours, 7 days) through 24 months of follow-up after implantation

    Time frame: From CLS activation to 24 months after implantation

  2. DDAF burden

    The time from CLS activation to the first day with a DDAF burden ≥1% (≈15 minutes) determined within a follow-up period of 24 months after implantation

    Time frame: From CLS activation to 24 months after implantation

  3. Heart Rate histograms

    Heart Rate histograms of sensed and paced beats \[% time\] at 1-year and 2-year follow-ups

    Time frame: At 1 year and 2 years after implantation

07

Study locations

1 of 12 sites recruiting
08

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Jul 17, 2026, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
09

Registry details

Key details

Study ID
NCT07608822
Responsible party
Sponsor
First posted
May 27, 2026
Start date
May 29, 2026
Primary completion
May 29, 2028 (estimated)
Completion
May 29, 2030 (estimated)
Last update
Jul 17, 2026

Study contacts

Martina Del Maestro
Contact
CLS-CSP-STREAM@biotronik.com
+393426529214
Paola Napoli
Contact
CLS-CSP-STREAM@biotronik.com
+393357369277
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

Contact study team

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion