ClinicalTrials.gg
CompletedNCT07425912NANO-KIDSUpdated Nov 18, 2026

Real-World Evaluation of TouchCare Nano in Pediatric Type 1 Diabetes

An observational study in Type 1 Diabetes Mellitus, sponsored by University of Campania Luigi Vanvitelli. Completed at 3 sites in Italy. Open to participants aged 6 Years to 18 Years. Per ClinicalTrials.gov, last updated 2026-11-18.

Sponsored by University of Campania Luigi Vanvitelli · Observational

How we know

Updated Nov 18, 2026Primary completion movedStudy completion moved+4 moreGo to Updates ↓

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Study type
Observational
Model
Cohort
Time perspective
Prospective
Enrollment
80
Ages
6 Years to 18 Years
Sex
All
01

Where this study stands

Counted across the records on this site · 2026-11-24

Among 170 studies in Diabetes Mellitus, Type 1 with a site in Italy — 32 open to participants now, 40 under way, 6 of them phase 3. Diabetes Mellitus, Type 1 · Italy.

Enrollment
33rd of 44
80 · median 223
Started
2025
with 11 others
Observational
44 of 170
16 open now
Registered
163rd of 170
by date
Lead sponsor
5 of 170
University of Campania Luigi Vanvitelli

Among the 170 studies in Diabetes Mellitus, Type 1 with a site in Italy, this one is the 33rd largest by enrollment of the 44 observational ones that give a count, is one of 12 that started in 2025, is one of 44 observational ones, and was the 163rd registered.

Diabetes Mellitus, Type 1

3,758 studies on the registry are indexed under Diabetes Mellitus, Type 1; 600 are open to participants now.

Browse Diabetes Mellitus, Type 1 studies →

Open to participants now

32 of the 170 studies in Diabetes Mellitus, Type 1 with a site in Italy are open now. Recruiting first, the newest first:

27 more — sign in →

All 32 open studies →

A study can be open while its sites in Italy have not opened yet or have stopped. Only those recruiting at a site in Italy →

Who these studies take

Of the 417 Diabetes Mellitus, Type 1 studies recruiting now, 129 (31%) set no upper age limit and 262 (63%) stop at 75 or younger; 187 take children under 18; 67 take healthy volunteers.

This study: 6 Years to 18 Years · all sexes · no healthy volunteers.

The full table on the hub →

This tab as a report to print or save as PDF → With an account.

Was this useful?
Get alerts for this landscapeDownload CSVNarrow it in search →With an account: a weekly mail of what changed among 170 studies in Diabetes Mellitus, Type 1 with a site in Italy, or all of them as a file.
02

Study summary

The goal of this observational study is to evaluate the effectiveness and safety of the TouchCare Nano automated insulin delivery system in children and adolescents with type 1 diabetes during routine clinical care. The study includes an initial six-month period using conventional AutoMode and a planned additional six-month observational extension using the AutoMeal function in a subset of the original participants.

The main questions are:

  • How do glucose levels and insulin delivery change during the first six months of TouchCare Nano use?
  • How do glucose levels and insulin delivery change when participants switch from conventional AutoMode to AutoMeal?
  • How often do severe hypoglycemia and diabetic ketoacidosis occur during follow-up?

In conventional AutoMode, users estimate and enter the carbohydrate content of meals to calculate meal insulin doses. With AutoMeal, users announce the type of meal-breakfast, lunch, dinner, or snack-without routinely entering carbohydrate amounts or manually selecting an insulin dose. The conventional carbohydrate-based bolus calculator remains available when needed.

Treatment decisions, including transition to AutoMeal, are made as part of routine clinical care. Researchers collect glucose sensor data, insulin delivery information, routine clinical measurements, and safety information. Assessments take place at baseline and after 1, 3, and 6 months in the initial phase. Participants who adopt AutoMeal are assessed immediately before the transition and after 3 and 6 months of AutoMeal use.

Read the detailed description

This multicentre, prospective, observational study evaluates the real-world effectiveness and safety of the TouchCare Nano automated insulin delivery (AID) system with the APGO algorithm in young people with type 1 diabetes. The study comprises an initial six-month observation period using conventional AutoMode and a planned six-month observational extension using the AutoMeal function in a subset of the original cohort.

Participants were eligible for the initial phase if they were aged 6-18 years, had type 1 diabetes for at least six months, weighed at least 20 kg, and required a total daily insulin dose of at least 10 units, in addition to meeting the other protocol eligibility criteria. Initiation of the system and subsequent treatment decisions occurred within routine clinical care, without study-assigned treatment allocation.

Initial AutoMode phase

Participants were followed for six months after initiation of the TouchCare Nano AID system. In conventional AutoMode, the APGO algorithm automatically adjusts basal insulin delivery and administers correction boluses, while users estimate carbohydrate intake and use the integrated bolus calculator for meal boluses.

Clinical assessments were performed at baseline and after 1, 3, and 6 months. Outcomes included time in range (TIR; 70-180 mg/dL), additional continuous glucose monitoring (CGM) metrics, insulin delivery parameters, HbA1c, anthropometric measurements, and safety events.

Of the 80 participants initially enrolled, 76 completed the initial six-month observation period.

AutoMeal extension

After completing six months of conventional AutoMode use, the 76 participants were offered the opportunity to use AutoMeal during routine clinical care. Forty-eight participants adopted AutoMeal and were included in the six-month extension analysis; 28 continued using conventional AutoMode.

The AutoMeal extension was included in the original ethics committee-approved protocol and covered by the original informed consent. No separate consent process was conducted for this phase.

AutoMeal allows users to announce meals by selecting breakfast, lunch, dinner, or snack, without routinely entering carbohydrate quantities or manually selecting or confirming an insulin dose. Following meal announcement, the system automatically manages prandial insulin delivery, while automated basal modulation and correction boluses remain active. The conventional carbohydrate-based bolus calculator remains available.

Participants and caregivers received instructions to announce meals 15 minutes before food intake. They were advised to use the conventional carbohydrate-based bolus calculator when the estimated carbohydrate content of a meal differed by more than 20% from the individual's usual carbohydrate content for the corresponding meal category.

The glucose target of 110 mg/dL, active insulin time of two hours, and enabled automated correction boluses remained unchanged following transition from AutoMode to AutoMeal.

The extension baseline was the assessment at the end of the initial six-month AutoMode phase, immediately before transition to AutoMeal. Further assessments occurred after 3 and 6 months of AutoMeal use, corresponding to approximately 9 and 12 months after initial AID initiation. CGM and insulin delivery metrics were assessed using data from the 15 days preceding each extension assessment.

The primary outcome of the extension was the change in TIR (70-180 mg/dL) from the extension baseline to six months of AutoMeal use. Additional outcomes included time in tight range (70-140 mg/dL), time above and below range, mean sensor glucose, glucose standard deviation, coefficient of variation, glucose management indicator, HbA1c, and insulin delivery parameters, including total daily insulin dose, basal insulin, automated basal insulin, and automated bolus insulin.

Safety monitoring included severe hypoglycemia requiring assistance from another person and diabetic ketoacidosis throughout follow-up. Routine diabetes education and clinical care continued during both phases.

The study was conducted in accordance with the Declaration of Helsinki and approved by the relevant Ethics Committee. Written informed consent and age-appropriate assent were obtained, as applicable. Final study data collection was completed on October 15, 2026.

03

Conditions studied

  • Type 1 Diabetes Mellitus

Keywords

  • Type 1 diabetes
  • Automated insulin delivery
  • Children and adolescents
  • Insulin pump
  • Continuous glucose monitoring
  • Hybrid closed-loop system
  • Real-world study
  • Artificial pancreas
04

Who can participate

The criteria were revised on the registry on Nov 18, 2026. See what changed

Ages eligible
6 Years to 18 Years
Sexes eligible
All
Accepts healthy volunteers
No
Sampling method
Non-probability sample

Study population

Children and adolescents with type 1 diabetes receiving routine care at specialized pediatric diabetes centers in Italy and initiating the TouchCare Nano automated insulin delivery system on clinical indication. A subset of the original cohort continued into a planned six-month observational extension using AutoMeal after completing six months of conventional AutoMode use.

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Age 6 to 18 years
  • Diagnosis of type 1 diabetes mellitus for ≥6 months
  • Treatment with insulin therapy (multiple daily injections or continuous subcutaneous insulin infusion) for ≥6 months prior to enrolment
  • Clinical indication for transition to insulin pump therapy according to routine diabetes care
  • Ability of participant and family to understand and comply with study procedures
  • Written from parent(s) or legal guardian(s), and assent from the participant when applicable

Exclusion criteria

Exclusion Criteria:

  • Diabetic ketoacidosis within the 3 months before enrollment
  • Use of medications known to affect blood glucose levels
  • Body weight less than 20 kilograms
  • Total daily insulin dose less than 10 international units

Eligibility for the AutoMeal extension:

Participation in and completion of the initial six-month observation period using conventional AutoMode.

Voluntary adoption of the AutoMeal function within routine clinical care. The original age eligibility criterion applies to initial enrollment. Participants reaching adulthood during follow-up remained eligible to continue. The extension was covered by the original ; no separate consent process was conducted.

Terms in these criteria, in plain language(1)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

05

Study design

Observational model
Cohort
Time perspective
Prospective
Enrollment
80 participants (actual)
Patient registry
No

Groups and cohorts

  • Young people with type 1 diabetes using the TouchCare Nano system

    Participants aged 6-18 years at initial enrollment with type 1 diabetes using the TouchCare Nano automated insulin delivery system as part of routine clinical care. The original cohort included 80 participants, of whom 76 completed six months of follow-up using conventional AutoMode, with carbohydrate-based meal boluses. At the end of this period, 48 participants voluntarily adopted the AutoMeal function and were followed for an additional six months. AutoMeal allows users to announce the meal type without routinely entering carbohydrate amounts or manually selecting an insulin dose. The remaining 28 participants continued using conventional AutoMode. For the AutoMeal extension, baseline was defined as the end of the initial six-month AutoMode period, immediately before transition to AutoMeal. Subsequent assessments were performed after 3 and 6 months of AutoMeal use. Treatment decisions were made within routine clinical care, without study-assigned treatment allocation.

06

What researchers measure

Primary outcomes

  1. Time in Range (70-180 mg/dL) during the initial AutoMode phase

    Percentage of time that continuous glucose monitoring values are between 70 and 180 mg/dL during the initial six-month period of TouchCare Nano use in conventional AutoMode.

    Time frame: Baseline, 1 month, 3 months, and 6 months

  2. Time in Range (70-180 mg/dL) during the AutoMeal extension

    Percentage of time that continuous glucose monitoring values are between 70 and 180 mg/dL, assessed at the extension baseline and after three and six months of AutoMeal use. Changes from the extension baseline are evaluated at both follow-up assessments and expressed in percentage points. The extension baseline corresponds to completion of six months of conventional AutoMode use, immediately before transition to AutoMeal. Each assessment uses CGM data from the preceding 15 days.

    Time frame: Extension baseline and 3 and 6 months after transition to AutoMeal, corresponding to approximately 6, 9, and 12 months after initial TouchCare Nano initiation.

Secondary outcomes

  1. Time below normale glucose range (TBR)

    TBR is the percentage of time during which glucose values measured by continuous glucose monitoring (CGM) are below 70 mg/dL

    Time frame: Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.

  2. Total daily insulin dose delivered by insulin pump

    Total amount of insulin administered per day, expressed in units per day (U/day), including both basal and bolus insulin delivery.

    Time frame: Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.

  3. Glycated hemoglobin (HbA1c)

    Glycated hemoglobin (HbA1c) reflects the average blood glucose concentration over the preceding 8-12 weeks and is expressed as percentage (%) and mmol/mol.

    Time frame: Initial phase: baseline and 3 and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.

  4. Number of severe low blood sugar events

    Number of episodes of severe hypoglycaemia requiring assistance from another person to actively administer carbohydrate, glucagon, or other resuscitative actions.

    Time frame: Throughout the initial six-month AutoMode phase and the subsequent six-month AutoMeal extension, up to approximately 12 months after TouchCare Nano initiation.

  5. Time above glucose normal range (TAR)

    TAR is the percentage of time during which glucose values measured by continuous glucose monitoring (CGM) exceed 180 mg/dL

    Time frame: Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.

  6. Mean sensor glucose

    Average interstitial glucose concentration measured by continuous glucose monitoring during the assessment period.

    Time frame: Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.

  7. Total daily basal insulin dose delivered by insulin pump

    Total daily basal insulin dose delivered by insulin pump, defined as the cumulative background insulin administered through continuous subcutaneous insulin infusion over a 24-hour period (U/day), excluding bolus insulin.

    Time frame: Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.

  8. Total daily bolus insulin dose delivered by insulin pump

    Total daily bolus insulin dose delivered by insulin pump, defined as the cumulative amount of corrective and meal-related insulin administered through continuous subcutaneous insulin infusion over a 24-hour period (U/day), excluding basal/background insulin

    Time frame: Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.

  9. Body mass index (BMI)

    Body mass index is calculated as weight in kilograms divided by height in meters squared (kg/m²) and reflects overall body weight relative to height.

    Time frame: Initial phase: baseline and 3 and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.

  10. Number of diabetic ketoacidosis events

    Number of episodes of diabetic ketoacidosis defined by hyperglycaemia associated with metabolic acidosis and requiring medical evaluation or hospitalization.

    Time frame: Throughout the initial six-month AutoMode phase and the subsequent six-month AutoMeal extension, up to approximately 12 months after TouchCare Nano initiation.

07

Study locations

3 sites
  • Pediatric Diabetology Unit at the AOU "G. Martino"
    Messina, Italy, Italy
  • Centro Regionale di Diabetologia Pediatrica- AOU Univesità degli Studi della Campania "L.Vanvitelli"
    Naples, Italy, Italy
  • Department of Diabetology and Endocrinology at the AOU Meyer IRCCS
    Florence, Italy
08

References and documents

Publications

  • Petrovski G, Campbell J, Pasha M, Hussain K, Khalifa A, Umer F, Almajaly D, Hamdar M, Heuvel TVD, Edd SN. Twelve-Month Follow-up from a Randomized Controlled Trial of Simplified Meal Announcement Versus Precise Carbohydrate Counting in Adolescents with Type 1 Diabetes Using the MiniMed 780G Advanced Hybrid Closed-Loop System. Diabetes Technol Ther. 2024 Mar;26(S3):76-83. doi: 10.1089/dia.2023.0429. PubMed 38377327 ↗
  • Petrovski G, Campbell J, Pasha M, Day E, Hussain K, Khalifa A, van den Heuvel T. Simplified Meal Announcement Versus Precise Carbohydrate Counting in Adolescents With Type 1 Diabetes Using the MiniMed 780G Advanced Hybrid Closed Loop System: A Randomized Controlled Trial Comparing Glucose Control. Diabetes Care. 2023 Mar 1;46(3):544-550. doi: 10.2337/dc22-1692. PubMed 36598841 ↗
  • Amadou C, Melki V, Allain J, Clavel S, Gouet D, Chaillous L, Catargi B, Schaeplynck-Belicard P, Petit C, Thivolet C, Penfornis A. Performance and patients' satisfaction with the A7+TouchCare insulin patch pump system: A randomized controlled non-inferiority study. PLoS One. 2023 Aug 24;18(8):e0289684. doi: 10.1371/journal.pone.0289684. eCollection 2023. PubMed 37616289 ↗
  • Marks BE, Meighan S, Zehra A, Douvas JL, Rearson A, Suresh R, Brown EA, Wolf RM. Real-World Glycemic Outcomes with Early Omnipod 5 Use in Youth with Type 1 Diabetes. Diabetes Technol Ther. 2023 Nov;25(11):782-789. doi: 10.1089/dia.2023.0337. Epub 2023 Sep 20. PubMed 37646634 ↗
  • Forlenza GP, DeSalvo DJ, Aleppo G, Wilmot EG, Berget C, Huyett LM, Hadjiyianni I, Mendez JJ, Conroy LR, Ly TT, Sherr JL. Real-World Evidence of Omnipod(R) 5 Automated Insulin Delivery System Use in 69,902 People with Type 1 Diabetes. Diabetes Technol Ther. 2024 Aug;26(8):514-525. doi: 10.1089/dia.2023.0578. Epub 2024 Feb 16. PubMed 38375861 ↗
  • Kim JY, Jin SM, Kang ES, Kwak SH, Yang Y, Yoo JH, Bae JH, Moon JS, Jung CH, Bae JC, Suh S, Moon SJ, Song SO, Chon S, Kim JH. Comparison between a tubeless, on-body automated insulin delivery system and a tubeless, on-body sensor-augmented pump in type 1 diabetes: a multicentre randomised controlled trial. Diabetologia. 2024 Jul;67(7):1235-1244. doi: 10.1007/s00125-024-06155-y. Epub 2024 Apr 18. PubMed 38634887 ↗
  • Asgharzadeh A, Patel M, Connock M, Damery S, Ghosh I, Jordan M, Freeman K, Brown A, Court R, Baldwin S, Ogunlayi F, Stinton C, Cummins E, Al-Khudairy L. Hybrid closed-loop systems for managing blood glucose levels in type 1 diabetes: a systematic review and economic modelling. Health Technol Assess. 2024 Dec;28(80):1-190. doi: 10.3310/JYPL3536. PubMed 39673446 ↗
  • Hughes MS, Levy CJ. The Future of Automated Insulin Delivery Systems. Endocr Pract. 2025 Sep;31(9):1162-1170. doi: 10.1016/j.eprac.2025.05.752. Epub 2025 Jun 16. PubMed 40532759 ↗
  • Zanfardino A, Iafusco D, Ippolito G, Del Giudice EM, Rollato AS, Chianese A, Figuccia A, Toni S, Ferlito AG, Piccini B. Real-World Effectiveness and Safety of a Tubeless Automated Insulin Delivery System With an Adaptive Control Algorithm (APGO) in Children and Adolescents With Type 1 Diabetes: A Multicentre Observational Study. Diabetes Obes Metab. 2026 Jul 23. doi: 10.1111/dom.71101. Online ahead of print. PubMed 42488981 ↗

Individual participant data

Plan to share: No

09

Timeline

1 registry update since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedDate before it movedWhere the date was before it movedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Ran from Sep 2025 to primary completion in Oct 2026, 13 months.

Of 248 non-industry observational studies under Diabetes Mellitus, Type 1, half reached primary completion within 30 months of starting (the median), counting those still running; a quarter within 12 and three quarters within 78. This study's 13 months is below that.

Counting every sponsor, half of 298 studies reached it within 30 months; a quarter within 12 and three quarters within 69.

Since we started tracking on Sep 25, 2026, the dates moved once, on Nov 18, 2026: primary completion Mar 2026 → Oct 2026 and completion Mar 2026 → Oct 2026.

Earlier changes are on the record history on ClinicalTrials.gov ↗

How these figures are worked out, and which studies are left out of them.

Registered
Feb 7, 2026
First posted
Feb 23, 2026
StartActual
Sep 5, 2025
Primary completionActual
Oct 15, 2026was Mar 2026
CompletionActual
Oct 15, 2026was Mar 2026
Last update
Nov 18, 2026
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
Primary completion
Mar 5, 2026→Oct 15, 2026
Nov 18, 2026
Study completion
Mar 15, 2026→Oct 15, 2026
Nov 18, 2026
Enrollment
76→80
Nov 18, 2026
Eligibility
3 exclusion criteria added
What changed in the criteria
Exclusion criteria
  • AddedEligibility for the AutoMeal extension:
  • AddedParticipation in and completion of the initial six-month observation period using conventional AutoMode.
  • AddedVoluntary adoption of the AutoMeal function within routine clinical care. The original age eligibility criterion applies to initial enrollment. Participants reaching adulthood during follow-up remained eligible to continue. The extension was covered by the original informed consent; no separate consent process was conducted.
Nov 18, 2026
Interventions
Arm changed Children and adolescents with type 1 diabetes using the TouchCare Nano system→Young people with type 1 diabetes using the TouchCare Nano system
Nov 18, 2026
Primary outcomes
2 added, 1 removed
What changed in the outcomes
  • AddedTime in Range (70-180 mg/dL) during the initial AutoMode phaseTime frame: Baseline, 1 month, 3 months, and 6 months
  • AddedTime in Range (70-180 mg/dL) during the AutoMeal extensionTime frame: Extension baseline and 3 and 6 months after transition to AutoMeal, corresponding to approximately 6, 9, and 12 months after initial TouchCare Nano initiation.
  • RemovedTime in normal glucose range (TIR)Time frame: Baseline, 1 month, 3 months, and 6 months
Nov 18, 2026
Secondary outcomes
10 time frame changed
What changed in the outcomes
  • Time frameTime below normale glucose range (TBR)Baseline, 1 month, 3 months, and 6 months → Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
  • Time frameTotal daily insulin dose delivered by insulin pumpBaseline, 1 month, 3 months, and 6 months → Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
  • Time frameGlycated hemoglobin (HbA1c)Baseline, 3 months, and 6 months → Initial phase: baseline and 3 and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
  • Time frameNumber of severe low blood sugar eventsFrom initiation of the A8 TouchCare® Nano system to 6 months of follow-up → Throughout the initial six-month AutoMode phase and the subsequent six-month AutoMeal extension, up to approximately 12 months after TouchCare Nano initiation.
  • Time frameTime above glucose normal range (TAR)Baseline and at 1, 3, and 6 months → Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
  • Time frameMean sensor glucoseBaseline, 1 month, 3 and 6 months → Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
  • Time frameTotal daily basal insulin dose delivered by insulin pumpBaseline, 1 month, 3 months, 6 months → Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
  • Time frameTotal daily bolus insulin dose delivered by insulin pumpBaseline, 1 month, 3 months, and 6 months → Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
  • Time frameBody mass index (BMI)Baseline, 3 months, 6 months → Initial phase: baseline and 3 and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
  • Time frameNumber of diabetic ketoacidosis eventsFrom initiation of the A8 TouchCare® Nano system to 6 months of follow-up → Throughout the initial six-month AutoMode phase and the subsequent six-month AutoMeal extension, up to approximately 12 months after TouchCare Nano initiation.
Nov 18, 2026
Show all 1 update
  1. Nov 18, 2026
    Primary completion Mar 5, 2026→Oct 15, 2026
    Study completion Mar 15, 2026→Oct 15, 2026
    Enrollment 76→80
    Eligibility 3 exclusion criteria added
    What changed in the criteria
    Exclusion criteria
    • AddedEligibility for the AutoMeal extension:
    • AddedParticipation in and completion of the initial six-month observation period using conventional AutoMode.
    • AddedVoluntary adoption of the AutoMeal function within routine clinical care. The original age eligibility criterion applies to initial enrollment. Participants reaching adulthood during follow-up remained eligible to continue. The extension was covered by the original informed consent; no separate consent process was conducted.
    Primary outcomes 2 added, 1 removed
    What changed in the outcomes
    • AddedTime in Range (70-180 mg/dL) during the initial AutoMode phaseTime frame: Baseline, 1 month, 3 months, and 6 months
    • AddedTime in Range (70-180 mg/dL) during the AutoMeal extensionTime frame: Extension baseline and 3 and 6 months after transition to AutoMeal, corresponding to approximately 6, 9, and 12 months after initial TouchCare Nano initiation.
    • RemovedTime in normal glucose range (TIR)Time frame: Baseline, 1 month, 3 months, and 6 months
    Secondary outcomes 10 time frame changed
    What changed in the outcomes
    • Time frameTime below normale glucose range (TBR)Baseline, 1 month, 3 months, and 6 months → Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
    • Time frameTotal daily insulin dose delivered by insulin pumpBaseline, 1 month, 3 months, and 6 months → Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
    • Time frameGlycated hemoglobin (HbA1c)Baseline, 3 months, and 6 months → Initial phase: baseline and 3 and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
    • Time frameNumber of severe low blood sugar eventsFrom initiation of the A8 TouchCare® Nano system to 6 months of follow-up → Throughout the initial six-month AutoMode phase and the subsequent six-month AutoMeal extension, up to approximately 12 months after TouchCare Nano initiation.
    • Time frameTime above glucose normal range (TAR)Baseline and at 1, 3, and 6 months → Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
    • Time frameMean sensor glucoseBaseline, 1 month, 3 and 6 months → Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
    • Time frameTotal daily basal insulin dose delivered by insulin pumpBaseline, 1 month, 3 months, 6 months → Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
    • Time frameTotal daily bolus insulin dose delivered by insulin pumpBaseline, 1 month, 3 months, and 6 months → Initial phase: baseline and 1, 3, and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
    • Time frameBody mass index (BMI)Baseline, 3 months, 6 months → Initial phase: baseline and 3 and 6 months after TouchCare Nano initiation; AutoMeal extension: extension baseline and 3 and 6 months after transition to AutoMeal.
    • Time frameNumber of diabetic ketoacidosis eventsFrom initiation of the A8 TouchCare® Nano system to 6 months of follow-up → Throughout the initial six-month AutoMode phase and the subsequent six-month AutoMeal extension, up to approximately 12 months after TouchCare Nano initiation.
    Interventions Arm changed Children and adolescents with type 1 diabetes using the TouchCare Nano system→Young people with type 1 diabetes using the TouchCare Nano system
    + 3 other changes: verification date, description and references

From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗

10

Registry details

Key details

Study ID
NCT07425912
Collaborators
Ospedale Meyer, University of Messina
Responsible party
Angela Zanfardino,MD (Medical Doctor-PhD, University of Campania Luigi Vanvitelli) — Principal investigator
First posted
Feb 23, 2026
Start date
Sep 5, 2025
Primary completion
Oct 15, 2026
Completion
Oct 15, 2026
Last update
Nov 18, 2026

Study contacts

Angela Zanfardino, MD
principal investigator · University of Campania "L.Vanvitelli"

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Nov 2026. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion