ClinicalTrials.gg
CompletedNCT07400718Updated Feb 12, 2026

Head-to-Head Comparison Study Between Different FDA Registered Allergy Skin Test Applicators

An interventional study of AllerTest-10 Multi-Head Skin Test Device and Skintestor OMNI Multi-Head Skin Test Device in Allergy, Hypersensitivity, Immediate and Ig-E Mediated Food, sponsored by QHSLab, Inc.. Completed at 1 site in United States. Open to participants aged 18 Years to 65 Years, including healthy volunteers. Per ClinicalTrials.gov, last updated 2026-02-12.

Primary conditionHypersensitivity, ImmediateRegistry: HypersensitivityReclassifiedWhy we changed it
Registry
Hypersensitivity — the first condition term the registry derived for this study.
ClinicalTrials.gg
Hypersensitivity, Immediate
Why
  1. The study's listed conditions name Hypersensitivity, Immediate, a narrower term within Hypersensitivity.
Confidence
High: the new condition is named in the study's own listed conditions. Of 351 hand-checked studies reclassified this way, 68% were exactly right and 84% in the right disease family; the registry's first term was right for 5% (measured 2026-10-21). How we classify →
Wrong?
Tell us the study's main condition →

Sponsored by QHSLab, Inc. · Not applicable, Interventional, and Diagnostic

Phase
Not applicable
Study type
Interventional
Enrollment
30
Allocation
Randomized
Ages
18 Years to 65 Years
Sex
All
01

Study summary

This clinical study, titled "Head-to-Head Comparison Study between Different FDA Registered Allergy Skin Test Applicators," aims to compare the reliability and clinical performance of three skin prick test (SPT) devices: Allertest™ Multiple Skin Test Applicator, Lincoln Multi-Test II, and Greer Skintestor OMNI Applicator. The primary objective is to evaluate the consistency and accuracy of these devices in allergy testing.

Read the detailed description

Background and Rationale:

Percutaneous allergy skin testing remains the gold standard diagnostic method for IgE-mediated allergic disease. Multiple-head skin prick test (SPT) devices enable simultaneous application of multiple allergens, improving testing efficiency while potentially reducing patient discomfort. However, significant inter-device variability exists among commercially available devices, with important implications for diagnostic accuracy and clinical interpretation.

Intra-device variability-inconsistent responses across individual test heads within a single device-represents a particularly concerning phenomenon that may lead to physician misinterpretation and potentially inappropriate treatment decisions. Such variability can be attributed to manufacturing factors including tooling mold precision, molding equipment quality, and process controls during production. Prior research has demonstrated that devices with lower finished product variability exhibit improved clinical performance characterized by reduced false-positive reactions to negative controls.

Study Design:

This prospective, single-visit, head-to-head device comparison study employed a paired design in which each participant served as their own control, receiving testing with two devices simultaneously-one device applied to each forearm. This within-subject design minimizes inter-individual variability and provides robust comparative data.

Participants were allocated into two comparison groups based on device head configuration: a 10-head device comparison (n=13) and an 8-head device comparison (n=17). Device assignment to right versus left forearm was randomized. Testing personnel were blinded to solution contents (histamine versus glycerin) during application, and a separate evaluator blinded to device assignment recorded wheal measurements.

Study Procedures:

All testing was performed by trained personnel in accordance with standard percutaneous skin testing protocols. Histamine dihydrochloride (1 mg/mL; ALK-Abello) served as the positive control and glycerin solution (ALK-Abello) served as the negative control. Devices were applied to the volar forearm surfaces with standardized pressure and technique. Test sites were maintained at least 2 cm apart to prevent cross-contamination between histamine and glycerin reactions.

Wheal measurements were obtained 15-20 minutes post-application using the mean diameter method (average of longest diameter and its perpendicular midpoint), consistent with established international guidelines. Pain assessment was performed immediately following device application.

Statistical Considerations:

Paired comparisons between devices were analyzed using Wilcoxon signed-rank tests for continuous variables and McNemar's test for dichotomous outcomes. Intra-device variability was quantified using the coefficient of variation (CV) calculated across test heads, with lower values indicating greater consistency. Exact binomial (Clopper-Pearson) confidence intervals were calculated for sensitivity and specificity estimates. Statistical significance was set at α=0.05 (two-sided).

Clinical Significance:

This study addresses an important knowledge gap regarding comparative clinical performance of multi-head allergy testing devices. Results provide evidence-based data to inform device selection decisions that may impact diagnostic accuracy, patient comfort, and reliability of allergen identification in clinical allergy practice.

02

Conditions studied

  • Allergy
  • Hypersensitivity, Immediate
  • Ig-E Mediated Food

Browse trials for

Keywords

  • Allergy skin testing
  • Skin prick test
  • Multi-head skin test device
  • Device comparison
  • Diagnostic accuracy
  • Sensitivity and specificity
  • Intra-device variability
03

In context

Hypersensitivity, Immediate Reclassified

82 studies on the registry are indexed under Hypersensitivity, Immediate; 7 are open to participants now.

This study's enrollment of 30 is below the median of 70 across 66 interventional studies indexed under Hypersensitivity, Immediate.

Browse Hypersensitivity, Immediate studies →

Lead sponsor

QHSLab, Inc. is the lead sponsor of 3 studies on the registry; 2 are open to participants now.

Compared within Hypersensitivity, Immediate, this study's primary condition as ClinicalTrials.gg classifies it; the registry's first condition term is Hypersensitivity. The counts are of registry records indexed under each term, refreshed daily. How we classify →

04

Who can participate

Ages eligible
18 Years to 65 Years
Sexes eligible
All
Accepts healthy volunteers
Yes

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Patients will be entered into this study only if they meet all of the following criteria:

    1. Written and signed obtained before starting any protocol-specific procedures.
    2. Subjects willing to withhold antihistamines, Leukotriene antagonists and H2 antagonists for at least 1 week before testing to avoid masking the histamine reactions on the skin.
    3. Male or female between 18 to 60 65 years, inclusive.
    4. Ability to comply with the study procedures and visit schedule.

Exclusion criteria

Exclusion Criteria:

  • Patients will NOT be entered into this study if they meet any of the following criteria:

    1. Anaphylactic reaction (constitutional) after the previous skin test with the same allergen
    2. Acute fever
    3. Systemic disease with acute manifestation or decompensation
    4. Abnormal skin condition in the area to be tested (such as eczema sunburn condition after sunbathing)
    5. Pregnancy
    6. Presence of dermatographism, severe atopic dermatitis, or use of tricyclic antidepressants.
    7. Current use of beta-blockers
    8. Known to any component of the test solutions (histamine or glycerin).
    9. Participation in another clinical study within 30 days before enrollment. Participation in another clinical study within 30 days before enrollment.
Terms in these criteria, in plain language(2)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

Hypersensitivity

An allergy, or another reaction of the immune system, to a substance. “Hypersensitivity to the study drug” means a known allergic reaction to it — not every side effect a medicine can have.

05

Study design

Phase
Not applicable
Primary purpose
Diagnostic
Allocation
Randomized
Intervention model
Crossover assignment
Masking
Quadruple (Participant, Care provider, Investigator, Outcomes assessor)
Enrollment
30 participants (actual)

Study arms

  • Experimental
    AllerTest Device

    Participants receive percutaneous allergy skin testing using an AllerTest multi-head device (either AllerTest-10 or AllerTest-8, manufactured by MedScience Research Group, Inc., distributed by ALK Abello, Inc.). The device is applied to one randomized forearm with a standardized histamine positive control (10 mg/mL histamine base) and a glycerin negative control (50% glycerin in saline). Outcomes measured include procedural pain (VAS 0-10), histamine wheal size at 15 minutes, glycerin wheal size at 15 minutes, sensitivity (proportion of histamine sites ≥3 mm), specificity (proportion of glycerin sites \<3 mm), and intra-device variability (coefficient of variation across test heads).

    Device: AllerTest-10 Multi-Head Skin Test Device · Device: AllerTest-8 Multi-Head Skin Test Device

  • Active comparator
    Comparator Device

    Participants receive percutaneous allergy skin testing using a comparator multi-head device (either Skintestor OMNI manufactured by Greer Laboratories, Inc., or Multi-Test II manufactured by Lincoln Diagnostics, Inc.). The device is applied simultaneously to the opposite forearm with identical standardized histamine positive control (10 mg/mL histamine base) and glycerin negative control (50% glycerin in saline). The same outcomes are measured to enable direct paired comparison: procedural pain (VAS 0-10), histamine wheal size at 15 minutes, glycerin wheal size at 15 minutes, sensitivity, specificity, and intra-device variability.

    Device: Skintestor OMNI Multi-Head Skin Test Device · Device: Multi-Test II Multi-Head Skin Test Device

Interventions

  • DeviceAllerTest-10 Multi-Head Skin Test Device

    FDA-cleared 10-head percutaneous skin test applicator manufactured by MedScience Research Group, Inc., distributed by ALK Abello, Inc. The device consists of 10 individual test heads arranged in a linear array, each with a standardized needle length designed to penetrate the epidermis without drawing blood. Applied with standardized pressure for simultaneous delivery of 10 test substances (histamine and glycerin controls in this study). Single-use, disposable device.

    Also known as: AllerTest 10-head

  • DeviceSkintestor OMNI Multi-Head Skin Test Device

    FDA-cleared 10-head percutaneous skin test applicator manufactured by Greer Laboratories, Inc. The device consists of 10 individual test heads arranged in a linear array for simultaneous application of multiple allergens and controls. Applied with standardized pressure for delivery of histamine and glycerin controls in this study. Single-use, disposable device.

  • DeviceMulti-Test II Multi-Head Skin Test Device

    FDA-cleared 8-head percutaneous skin test applicator manufactured by Lincoln Diagnostics, Inc. The device consists of 8 individual test heads arranged in a linear array for simultaneous application of multiple allergens and controls. Applied with standardized pressure for delivery of histamine and glycerin controls in this study. Single-use, disposable device.

  • DeviceAllerTest-8 Multi-Head Skin Test Device

    FDA-cleared 8-head percutaneous skin test applicator manufactured by MedScience Research Group, Inc., distributed by ALK Abello, Inc. The device consists of 8 individual test heads arranged in a linear array, each with a standardized needle length designed to penetrate the epidermis without drawing blood. Applied with standardized pressure for simultaneous delivery of 8 test substances (histamine and glycerin controls in this study). Single-use, disposable device.

06

What researchers measure

Primary outcomes

  1. Pain Assessment Using Visual Analog Scale (VAS)

    Procedural pain assessed immediately after device application using a 0-10 Visual Analog Scale (VAS), where 0 represents no pain and 10 represents unspeakable pain. Lower scores indicate less pain and better tolerability.

    Time frame: Immediately after device application (within 1 minute of skin test procedure)

  2. Sensitivity (Histamine Positive Control Performance)

    Proportion of histamine control sites producing wheal ≥3 mm diameter at 15 minutes post-application. A wheal of ≥3 mm is the standard threshold for a positive allergic reaction. Higher sensitivity indicates better device performance in reliably eliciting positive control responses. Calculated as: (number of histamine sites with wheal ≥3 mm) / (total number of histamine sites tested) × 100%.

    Time frame: 15 minutes after device application

  3. Specificity (Glycerin Negative Control Performance)

    Proportion of glycerin control sites producing wheal \<3 mm diameter at 15 minutes post-application. Glycerin should not produce a wheal response; a result \<3 mm confirms appropriate negative control performance and absence of non-specific mechanical irritation. Higher specificity indicates better device performance. Calculated as: (number of glycerin sites with wheal \<3 mm) / (total number of glycerin sites tested) × 100%.

    Time frame: 15 minutes after device application

Secondary outcomes

  1. Intra-Device Variability

    Coefficient of variation (CV) of histamine wheal sizes across all test heads within each device, calculated as CV = (standard deviation / mean) × 100%. Lower CV values indicate greater consistency and precision across test heads within the same device. This measure reflects the reliability of allergen delivery across multiple heads of a single device application.

    Time frame: 15 minutes after device application

  2. Mean Histamine Wheal Size

    Mean diameter (in millimeters) of wheals produced by histamine positive control across all test heads of each device. Wheal diameter measured using the mean diameter method (average of longest diameter and its perpendicular midpoint). Larger wheals indicate stronger positive control response.

    Time frame: 15 minutes after device application

  3. Mean Glycerin Wheal Size

    Mean diameter (in millimeters) of wheals produced by glycerin negative control across all test heads of each device. Wheal diameter measured using the mean diameter method (average of longest diameter and its perpendicular midpoint). Smaller measurements (ideally 0 mm) indicate appropriate negative control performance with minimal non-specific irritation.

    Time frame: 15 minutes after device application

  4. Proportion of Subjects with Clinically Significant Pain

    Proportion of participants experiencing more than mild pain, defined as a score greater than 4 on the Visual Analog Scale (VAS) for pain. The VAS ranges from 0 (no pain) to 10 (unspeakable pain), with higher scores indicating worse pain. A threshold of \>4 represents approximately 40% of the scale and indicates clinically meaningful discomfort. Lower percentages indicate better device tolerability across the study population. Reported as percentage with 95% exact binomial confidence intervals.

    Time frame: Immediately after device application (within 1 minute of skin test procedure)

07

Study locations

1 site
  • QHS Health center
    Miami, Florida 33155, United States
08

References and documents

Publications

  • Platts-Mills TA, Woodfolk JA. Rise in asthma cases. Science. 1997 Nov 7;278(5340):1001. doi: 10.1126/science.278.5340.997c. No abstract available. PubMed 9381194 ↗
  • Arbes SJ Jr, Gergen PJ, Elliott L, Zeldin DC. Prevalences of positive skin test responses to 10 common allergens in the US population: results from the third National Health and Nutrition Examination Survey. J Allergy Clin Immunol. 2005 Aug;116(2):377-83. doi: 10.1016/j.jaci.2005.05.017. PubMed 16083793 ↗
  • Cox L, Williams B, Sicherer S, Oppenheimer J, Sher L, Hamilton R, Golden D; American College of Allergy, Asthma and Immunology Test Task Force; American Academy of Allergy, Asthma and Immunology Specific IgE Test Task Force. Pearls and pitfalls of allergy diagnostic testing: report from the American College of Allergy, Asthma and Immunology/American Academy of Allergy, Asthma and Immunology Specific IgE Test Task Force. Ann Allergy Asthma Immunol. 2008 Dec;101(6):580-92. PubMed 19119701 ↗
  • Antunes J, Borrego L, Romeira A, Pinto P. Skin prick tests and allergy diagnosis. Allergol Immunopathol (Madr). 2009 May-Jun;37(3):155-64. doi: 10.1016/S0301-0546(09)71728-8. Epub 2009 Jul 23. PubMed 19769849 ↗
  • Bernstein IL, Li JT, Bernstein DI, Hamilton R, Spector SL, Tan R, Sicherer S, Golden DB, Khan DA, Nicklas RA, Portnoy JM, Blessing-Moore J, Cox L, Lang DM, Oppenheimer J, Randolph CC, Schuller DE, Tilles SA, Wallace DV, Levetin E, Weber R; American Academy of Allergy, Asthma and Immunology; American College of Allergy, Asthma and Immunology. Allergy diagnostic testing: an updated practice parameter. Ann Allergy Asthma Immunol. 2008 Mar;100(3 Suppl 3):S1-148. doi: 10.1016/s1081-1206(10)60305-5. No abstract available. PubMed 18431959 ↗

Individual participant data

Plan to share: No

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Feb 12, 2026, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT07400718
Lead sponsor
QHSLab, Inc.
Collaborators
ALK-Abelló A/S
Responsible party
Sponsor
First posted
Feb 10, 2026
Start date
Nov 12, 2025
Primary completion
Nov 30, 2025
Completion
Jan 30, 2026
Last update
Feb 12, 2026

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Feb 2026. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion