ClinicalTrials.gg
Not yet recruitingNCT07325045Updated Jan 8, 2026

Biomechanical Study of Lever Positioning Manipulation on Scoliosis

An interventional study of Lever positioning manipulation in Scoliosis, sponsored by The Third Affiliated hospital of Zhejiang Chinese Medical University. Not yet recruiting at 1 site in China. Open to participants aged 10 Years to 45 Years. Per ClinicalTrials.gov, last updated 2026-01-08.

Sponsored by The Third Affiliated hospital of Zhejiang Chinese Medical University · Not applicable, Interventional, and Treatment

How we know

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Phase
Not applicable
Study type
Interventional
Enrollment
30
Allocation
Not applicable
Ages
10 Years to 45 Years
Sex
All
01

Where this study stands

Counted across the records on this site · 2026-11-22

Among 55 studies in Scoliosis with a site in China — 22 open to participants now, 26 under way, none of them phase 3. Scoliosis · China.

Planned enrollment
29th of 37
30 · median 100
Started
2026
with 4 others
No phase
31 of 55
14 open now
Primary completion
2028-06
later than 23 of 25 live
Registered
49th of 55
by date

Among the 55 studies in Scoliosis with a site in China, this one is the 29th largest by planned enrollment of the 37 interventional ones that give a count, is one of 5 that started in 2026, is one of 31 with no phase, reaches primary completion later than 23 of the 25 other live ones, and was the 49th registered.

Scoliosis

660 studies on the registry are indexed under Scoliosis; 185 are open to participants now.

Browse Scoliosis studies →

Open to participants now

22 of the 55 studies in Scoliosis with a site in China are open now. Recruiting first, the newest first:

16 more — sign in →

All 22 open studies →

A study can be open while its sites in China have not opened yet or have stopped. Only those recruiting at a site in China →

Who these studies take

Of the 117 Scoliosis studies recruiting now, 23 (20%) set no upper age limit and 88 (75%) stop at 75 or younger; 98 take children under 18; 14 take healthy volunteers.

This study: 10 Years to 45 Years · all sexes · no healthy volunteers.

The full table on the hub →

This tab as a report to print or save as PDF → With an account.

Was this useful?
Get alerts for this landscapeDownload CSVNarrow it in search →With an account: a weekly mail of what changed among 55 studies in Scoliosis with a site in China, or all of them as a file.
02

Study summary

Research background Scoliosis is a common three-dimensional spinal deformity, especially in adolescents. In severe cases, it can lead to thoracic deformation and cardiopulmonary dysfunction. At present, clinical treatment is mainly based on Cobb angle to take observation, brace or surgical intervention, but there are problems such as poor compliance and large trauma. As a non-invasive massage therapy, leverage positioning manipulation has shown orthopedic effects in clinical practice, but its biomechanical mechanism has not been systematically quantified, which restricts its standardization and promotion.

Purpose of the study The purpose of this study is to quantify the mechanical and kinematic parameters of lever positioning manipulation in the treatment of scoliosis through biomechanical testing and finite element simulation technology, to construct an individualized finite element model, to analyze the stress and strain distribution of each structure of the spine under the intervention of manipulation, to reveal its biomechanical mechanism, and to provide scientific basis for the standardization of manipulation and the optimization of curative effect.

Research contents and methods The study is divided into two parts : In the first part, 30 patients with scoliosis were recruited. Through the integrated mechanical sensor and motion capture system, the mechanical parameters ( such as preload force, maximum pull force ) and kinematic parameters ( such as angle, angular velocity ) during the manipulation were recorded in real time. In the second part, based on the CT data of patients, the three-dimensional finite element model of T10-L2 segment was constructed by using Mimics, Geomagic, SolidWorks and ANSYS software to simulate the loading process of manipulation and analyze the stress and strain response of vertebral body, intervertebral disc and ligament complex under the action of manipulation.

Expected results and significance This study will systematically quantify the biomechanical characteristics of lever positioning manipulation for the first time, and clarify its mechanism of action in the treatment of thoracolumbar scoliosis. Through the finite element simulation, the stress distribution is visualized, which provides data support for the precision and individualization of manipulation, promotes the transformation of massage manipulation from ' experience dependence ' to ' quantitative science ', and lays a theoretical foundation for the development of intelligent orthopedic equipment in the future.

Ethics and quality control The study has passed the ethical review, and all participants will sign the informed consent. The manipulation was performed by the same experienced physician, and the data collection and analysis process was strictly controlled to ensure that the results were true and reliable.

03

Conditions studied

  • Scoliosis

Browse trials for

04

Who can participate

Ages eligible
10 Years to 45 Years
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  1. Age between 10 and 45 years, stable vital signs, no severe diseases in other systems;
  2. Diagnosed with scoliosis via standard anterior-posterior and lateral spinal radiographs, with a Cobb angle of 10° \< θ \<= 45°, and no severe complications;
  3. No history of spinal surgery;
  4. Voluntarily willing to participate in this study as a subject to undergo LPM procedures, and signing the form by themselves or their guardian. Note: Only patients meeting all of the above four criteria can be included in this study.

Exclusion criteria

Exclusion Criteria:

  1. Individuals with severe osteoporosis, spinal fractures, tumors, infections, or lesions within the spinal canal;
  2. Those with related complications, such as cardiopulmonary insufficiency ( class >= II) or severe neurological disorders;
  3. Those with compression fractures or spinal cord injuries;
  4. Individuals with cognitive impairment or mental disorders who cannot cooperate with biomechanical testing;
  5. Those with a history of spinal surgery;
  6. Those with severe skin lesions or dermatological diseases at the operation site;
  7. Women who are menstruating, pregnant, planning pregnancy, or in the postpartum period;
  8. Those with other conditions that may reduce the likelihood of completing the procedure, such as a fear of manual therapy;
  9. Individuals with unclear surface markers, affecting motion capture accuracy (e.g., >= 35 kg/m\^2).
Terms in these criteria, in plain language(3)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

NYHA class (heart failure)

The New York Heart Association’s four classes of how much heart failure limits physical activity.

I
No limits: ordinary activity causes no undue tiredness or breathlessness.
II
Slight limits: comfortable at rest, ordinary activity causes symptoms.
III
Marked limits: comfortable at rest, less than ordinary activity causes symptoms.
IV
Symptoms even at rest; any activity makes them worse.

Studies set their own limit — many outside heart failure leave out class III–IV, while heart failure studies may ask for a particular class. Check the class this study names.

BMI (body mass index)

Weight in kilograms divided by height in metres squared. Example: 70 kg and 1.75 m gives 70 ÷ (1.75 × 1.75) ≈ 22.9.

What counts as overweight or obesity differs between countries (some use lower cut-offs), so go by the range the study states.

05

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
30 participants (estimated)

Study arms

  • Experimental
    Lever positioning manipulation group

    Procedure: Lever positioning manipulation

Interventions

  • ProcedureLever positioning manipulation

    1 The patient took the prone position, exposed the waist and back, relaxed the whole body, and straightened the lower limbs. 2 The surgeon determined the top vertebra of the scoliosis according to the whole spine X-ray film, and used the olecranon of the elbow as the force fulcrum to accurately press the transverse process or spinous process on the convex side of the top vertebra, and the assistant fixed the shoulder of the patient. 3 The patient was asked to open his mouth and exhale, and the operator lifted the patient 's lower limbs on the other hand. Through the force arm conduction of the lower limbs-pelvis-spine, the lower limbs were lifted obliquely above the convex side to form a force arm lever. 4 When pulling to the resistance point, the surgeon pulled quickly with inch force. After the operation, the patient was allowed to rest in a prone position for 10 minutes.

06

What researchers measure

Primary outcomes

  1. elbow pulling the maximum force:Through the mechanical gloves and elbow sleeves, the mechanical parameters in the process of manual operation were collected.

    The operator wears mechanical measurement gloves and elbow sleeves to perform manual operation on the recipient. The mechanical parameters were collected by a pressure sensor, and the unit of measurement was Force ( Newton, N ). The average or peak value of each parameter was reported.

    Time frame: 2 weeks

Secondary outcomes

  1. maximum force of both hands pulling:Through the mechanical gloves and elbow sleeves, the mechanical parameters in the process of manual operation were collected.

    The operator wears mechanical measurement gloves and elbow sleeves to perform manual operation on the recipient. The mechanical parameters were collected by a pressure sensor, and the unit of measurement was Force ( Newton, N ). The average or peak value of each parameter was reported.

    Time frame: 2 weeks

  2. lateral flexion angle: Through the three-dimensional motion capture system, the kinematic parameters of spinal activity during manipulation were collected.

    The operator performs manual operation on the subject, and collects the kinematic parameters of the manual operation through the three-dimensional motion capture system equipment, and the measurement unit is : degree.

    Time frame: 2 weeks

  3. rotation angle: Through the three-dimensional motion capture system, the kinematic parameters of spinal activity during manipulation were collected.

    The operator performs manual operation on the subject, and collects the kinematic parameters of the manual operation through the three-dimensional motion capture system equipment, and the measurement unit is : degree.

    Time frame: 2 weeks

  4. pulling time:Through the three-dimensional motion capture system, the time of the manipulation process is recorded.

    The operator performs the manual operation on the subject, collects the kinematic parameters of the manual operation through the three-dimensional motion capture system equipment, and records the manual operation time at the same time. The measurement unit is seconds ( S ).

    Time frame: 2 weeks

  5. pulling angular acceleration:Through the three-dimensional motion capture system, the kinematic parameters of spinal activity during manipulation were collected.

    The operator performs the manual operation on the subject, collects the kinematic parameters of the manual operation through the three-dimensional motion capture system equipment, and records the manual operation time and angular velocity. The acceleration is calculated and the average and maximum values are recorded.

    Time frame: 2 weeks

  6. extension angle:Through the three-dimensional motion capture system, the kinematic parameters of spinal activity during manipulation were collected.

    The operator performs manipulation on the subject, collects the kinematics parameters of the manipulation through the three-dimensional motion capture system equipment, and records the angle.

    Time frame: 2 weeks

  7. preloading force of both hands:Through the mechanical gloves and elbow sleeves, the mechanical parameters in the process of manual operation were collected.

    The operator wears mechanical measurement gloves and elbow sleeves to perform manual operation on the recipient. The mechanical parameters were collected by a pressure sensor, and the unit of measurement was Force ( Newton, N ). The average or peak value of each parameter was reported.

    Time frame: 2 weeks

  8. Elbow preload force:Through the mechanical gloves and elbow sleeves, the mechanical parameters in the process of manual operation were collected.

    The operator wears mechanical measurement gloves and elbow sleeves to perform manual operation on the recipient. The mechanical parameters were collected by a pressure sensor, and the unit of measurement was Force ( Newton, N ). The average or peak value of each parameter was reported.

    Time frame: 2 weeks

  9. average pulling angular velocity:Through the three-dimensional motion capture system, the kinematic parameters of spinal activity during manipulation were collected.

    The operator performs manipulation on the subject. The kinematics parameters of the manipulation are collected by the three-dimensional motion capture system equipment, the angle change and time are recorded, the angular velocity is calculated, and the average value and the highest value are calculated.

    Time frame: 2 weeks

  10. The stress of each structure:Through the analysis of finite element software, the stress of the spine under the intervention of manipulation was simulated.

    The kinematics and mechanics data of the manipulation operation measured above were statistically analyzed. These data were input into the three-dimensional finite element model of the spine to simulate the manipulation. Through the finite element software analysis, the stress change cloud map and data of the spine were obtained, including the average value and the maximum and minimum values.

    Time frame: 2 weeks

  11. Strain of each structure:Through the analysis of finite element software, the strain of the spine under the intervention of manipulation was simulated.

    The kinematics and mechanics data of the manipulation of the previous measurement were statistically analyzed. The data were input into the three-dimensional finite element model of the spine to simulate the manipulation. Through the analysis of the finite element software, the strain cloud map and displacement data of the spine were obtained, including the average value and the maximum and minimum values.

    Time frame: 2 weeks

07

Study locations

1 site
08

References and documents

Individual participant data

Plan to share: No

No publications or documents are linked to this record.

09

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Start is estimated for Jan 2026; primary completion for Jun 2028, 29 months later.

Of 224 non-industry interventional studies with no phase under Scoliosis, half reached primary completion within 21 months of starting (the median), counting those still running; a quarter within 8 and three quarters within 58. This study's planned 29 months is above that.

Counting every sponsor, half of 234 studies reached it within 22 months; a quarter within 8 and three quarters within 60.

How these figures are worked out, and which studies are left out of them.

Registered
Nov 18, 2025
First posted
Jan 8, 2026
StartEst.
Jan 10, 2026
Primary completionEst.
Jun 30, 2028
CompletionEst.
Dec 31, 2028
Last update
Jan 8, 2026
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Jan 8, 2026, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT07325045
Lead sponsor
The Third Affiliated hospital of Zhejiang Chinese Medical University
Collaborators
Zhejiang Chinese Medical University
Responsible party
Tian Yv (Principal Investigator, The Third Affiliated hospital of Zhejiang Chinese Medical University) — Principal investigator
First posted
Jan 8, 2026
Start date
Jan 10, 2026 (estimated)
Primary completion
Jun 30, 2028 (estimated)
Completion
Dec 31, 2028 (estimated)
Last update
Jan 8, 2026

Study contacts

Yv Tian
Contact
tianyv2024@163.com
17683721740

Oversight

FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is not yet recruiting, as verified in Oct 2025. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion