An interventional study of Consumer Wearable Device Vital Sign Measurement in Trauma, Appendectomy and Pediatric ALL, sponsored by University of Alabama at Birmingham. Recruiting at 1 site in Ghana. Open to participants aged 3 Years to 18 Years. Per ClinicalTrials.gov, last updated 2026-10-27.
Sponsored by University of Alabama at Birmingham · Not applicable, Interventional, and Diagnostic
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
In Ghana, and many other low and middle income countries in Africa, manual vital signs monitoring is the prevalent mode of vital signs monitoring because continuous bedside monitors are non-functional. This lack of continuous vital signs monitoring may result in missed opportunities to catch physiologic deterioration.
The investigators propose to develop a dashboard that is based on the Garmin Venu 3, a consumer wearable device that reliably measures heart rate, SPO2, and respiratory rate, as an alternative to bedside monitors in hospitals in Ghana.
Vital sign (VS) monitoring is a universal tool used to assess patients' basic physiologic status, primarily to detect physiologic deterioration indicative of clinically meaningful events. Physiologic deterioration occurs relatively commonly in trauma and postoperative patient populations. In most high-income countries (HIC), such patients are therefore monitored by automated, continuous, bedside VS systems, while, in many low-and middle-income countries (LMIC), manual, intermittent (from every 15 minutes to every 6 hours) VS monitoring is still widely employed.
The investigators propose to further refine and scale up a CONsumer-grade wearable monitoring System to improve Outcomes in Low resource settings (CONSOL) in Ghana. CONSOL is a CWD based platform, developed by the MPIs, that collects and displays in near real time, HR, RR, and SpO2, with snapshots of the past 1 minute, and 1, 4, and 24 hours, viewable on an tabet or smartphone. The investigators propose to evaluate the use of CONSOL for VS monitoring of (a) pediatric trauma patients in the Emergency Department (ED) and (b) pediatric postoperative appendicitis patients on a surgical unit, given higher risk of physiologic deterioration indicative of clinically meaningful events in these patient populations, and because pediatric patients are often more limited, than adults, in their ability to communicate about signs and symptoms.
2,221 studies on the registry are indexed under Wounds and Injuries; 442 are open to participants now.
This study's planned enrollment of 250 is above the median of 70 across 1,426 interventional studies indexed under Wounds and Injuries.
Browse Wounds and Injuries studies →University of Alabama at Birmingham is the lead sponsor of 1,422 studies on the registry; 277 are open to participants now.
Of its 164 completed or terminated interventional studies of FDA-regulated products, 130 (79%) have results posted.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Consumer wearable devices (CWD)
Other: Consumer Wearable Device Vital Sign Measurement
Consumer Wearable Devices such as the Fitbit, are durable devices that can provide vital sign data.
Change in heart rate with CONSOL compared to pre-CONSOL implementation
The investigators will implement CONSOL and record the abnormal vital signs indicative of clinically meaningful events in the CONSOL group. The investigators will then compare the number of abnormal vital signs detected in the CONSOL group to that of the group of patient before CONSOL is implemented. The investigators will match the 2 groups on time period (e.g., CONSOL group recruited in 6-month period with pre-CONSOL group in the 6 months prior CONSOL. Vital sign measured is heart rate. Abnormal vital sign cutoffs are listed below: Heart Rate (beats/minute) 1-4 years old \< 60 or \>120 5-12 years old \<60 or \>110 13-18 years old \<60 or \>100
Time frame: During the intervention (vital sign monitoring using the Garmin Venu 3)
Change in respiratory rate with CONSOL compared to pre-CONSOL implementation
The investigators will implement CONSOL and record the abnormal vital signs indicative of clinically meaningful events in the CONSOL group. The investigators will then compare the number of abnormal vital signs detected in the CONSOL group to that of the group of patient before CONSOL is implemented. The investigators will match the 2 groups on time period (e.g., CONSOL group recruited in 6-month period with pre-CONSOL group in the 6 months prior CONSOL. Vital sign measured respiratory rate. Abnormal vital sign cutoffs are listed below: Respiratory Rate (breaths/minute) 1-4 years old \<20 or \>30 5-12 years old \<16 or \>20 13-18 years old \<12 or \>16
Time frame: During the intervention (vital sign monitoring using the Garmin Venu 3)
Change in SPO2 with CONSOL compared to pre-CONSOL implementation
The investigators will implement CONSOL and record the abnormal vital signs indicative of clinically meaningful events in the CONSOL group. The investigators will then compare the number of abnormal vital signs detected in the CONSOL group to that of the group of patient before CONSOL is implemented. The investigators will match the 2 groups on time period (e.g., CONSOL group recruited in 6-month period with pre-CONSOL group in the 6 months prior CONSOL. Vital sign measured SPO2. Abnormal vital sign cutoffs are listed below: SPO2\<92%
Time frame: During the intervention (vital sign monitoring using the Garmin Venu 3)
Change in time to detection of abnormal heart rate using CONSOL
Change in time to detection of abnormal heart rate (HR) will be estimated by assessing detection of abnormal HR in intervals of 15 minutes up to 6 hours (usual care intervals of manual VS measurement). Since CONSOL will be implemented in addition to usual care manual HR measurement, abnormal HR detected by CONSOL can be compared to abnormal HR detected by manual measurement at each interval. Abnormal heart rate cutoffs are listed below: Heart Rate (beats/minute) 1-4 years old \< 60 or \>120 5-12 years old \<60 or \>110 13-18 years old \<60 or \>100
Time frame: During the intervention (vital sign monitoring using the Garmin Venu 3)
Change in time to detection of abnormal SPO2 using CONSOL
Change in time to detection of abnormal SPO2 will be estimated by assessing detection of abnormal SPO2 in intervals of 15 minutes up to 6 hours (usual care intervals of manual VS measurement). Since CONSOL will be implemented in addition to usual care manual SPO2 measurement, abnormal SPO2 detected by CONSOL can be compared to abnormal SPO2 detected by manual measurement at each interval. Abnormal SPO2, cutoffs are listed below: SpO2 (%) \<92%
Time frame: During the intervention (vital sign monitoring using the Garmin Venu 3)
Change in time to detection of abnormal respiratory rate using CONSOL
Change in time to detection of abnormal respiratory rate (RR) will be estimated by assessing detection of abnormal RR in intervals of 15 minutes up to 6 hours (usual care intervals of manual RR measurement). Since CONSOL will be implemented in addition to usual care manual RR measurement, abnormal RR detected by CONSOL can be compared to abnormal RR detected by manual measurement at each interval. Abnormal respiratory rate cutoffs are listed below: Respiratory Rate (breaths/minute) 1-4 years old \<20 or \>30 5-12 years old \<16 or \>20 13-18 years old \<12 or \>16
Time frame: During the intervention (vital sign monitoring using the Garmin Venu 3)
Exploratory outcome: Investigation of the dynamic heart rate patterns associated with clinical deterioration and rescue interventions
The dynamic VS patterns associated with clinical deterioration and rescue interventions will be examined only for patients who experienced a rescue intervention. Vital signs measured is heart rate. Rescue interventions are defined as actions taken to stabilize a patient with quickly deteriorating physiological status.
Time frame: During the intervention (vital sign monitoring using the Garmin Venu 3)
Exploratory outcome: Investigation of the dynamic SPO2 patterns associated with clinical deterioration and rescue interventions
The dynamic VS patterns associated with clinical deterioration and rescue interventions will be examined only for patients who experienced a rescue intervention. Vital signs measured is SPO2. Rescue interventions are defined as actions taken to stabilize a patient with quickly deteriorating physiological status.
Time frame: During the intervention (vital sign monitoring using the Garmin Venu 3)
Exploratory outcome: Investigation of the dynamic skin temperature patterns associated with clinical deterioration and rescue interventions
The dynamic VS patterns associated with clinical deterioration and rescue interventions will be examined only for patients who experienced a rescue intervention. Vital signs measured is skin temperature. Rescue interventions are defined as actions taken to stabilize a patient with quickly deteriorating physiological status.
Time frame: During the intervention (vital sign monitoring using the Garmin Venu 3)
Exploratory outcome: Investigation of the dynamic respiratory rate patterns associated with clinical deterioration and rescue interventions
The dynamic VS patterns associated with clinical deterioration and rescue interventions will be examined only for patients who experienced a rescue intervention. Vital signs measured is respiratory rate. Rescue interventions are defined as actions taken to stabilize a patient with quickly deteriorating physiological status.
Time frame: During the intervention (vital sign monitoring using the Garmin Venu 3)
Plan to share: No — IPDs are considered PHI and can only be shared in a de-identified form. We have plans to share these de-identified data on ICPSR as per the Data Management and Sharing plan required by NIH
No publications or documents are linked to this record.
Started Oct 2026 (actual). Primary completion is estimated for Nov 2029, 37 months after the start.
Of 546 non-industry interventional studies with no phase under Wounds and Injuries, half reached primary completion within 24 months of starting (the median), counting those still running; a quarter within 9 and three quarters within 49. This study's planned 37 months is above that.
Counting every sponsor, half of 599 studies reached it within 24 months; a quarter within 9 and three quarters within 48.
Wounds and Injuries covers many different conditions, not one, so the studies compared here vary widely. Read these figures as a rough guide.
Start moved twice since we started tracking on Sep 25, 2026: Sep 2026 → Oct 2026, last on Oct 27, 2026.
Earlier changes are on the record history on ClinicalTrials.gov ↗
How these figures are worked out, and which studies are left out of them.
From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗
Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.
Contact study teamGet an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
University of Alabama at Birmingham →