An interventional study of 3d Printed implant and Conventionally constructed implant in Occlusal Wear of Teeth, sponsored by Mansoura University. Completed at 1 site in Egypt. Open to male participants aged 45 Years to 60 Years, including healthy volunteers. Per ClinicalTrials.gov, last updated 2023-11-18.
Sponsored by Mansoura University · Not applicable, Interventional, and Treatment
The aim of this study is to evaluate of two different construction techniques (digital and conventional techniques) for two implant retained complete mandibular overdenture regarding:
Evaluation was done in the following evaluation period:
T0: Immediately after over denture insertion. T6: 6 months after over denture insertion. T12: 12 months after over denture insertion.
Patient selection and study design:
Six patients who required complete denture were selected from the diagnostic clinic of Prosthodontic Department, Faculty of Dentistry, Mansoura University. All patients were informed about the procedures that was done and a written consent form of ethical committee. All patients had the right to withdraw from the study at any time.
Patients Grouping:
Patients were divided in to 2 equal groups:
Group (I): 3 patients received maxillary CD and mandibular 2-implant retained overdenture constructed by digital technique.
Group (II): 3 patients received maxillary CD and mandibular 2-implant retained overdenture constructed by conventional technique.
Surgical phase procedures:
After 3 months of osteointegration period, the implants were exposed, the cover screw was removed and the two healing abutments were screwed into the fixture using their driver for 7 to 10 days.
Each patient received maxillary complete denture against mandibular 2- implant retained complete overdenture with two different construction techniques.
The clinical procedures in the respective visits are described below:
Steps of conventional complete overdenture construction:
Digital complete overdenture construction:
Insertion the prosthesis into the patient's mouth and have them bit down until the resin has cured. Remove the prostheses and trim the excess resin. The prosthesis delivered and patient instructed about the aftercare and recall schedule steps.
Evaluation
Digital occlusal stability detection:
Group I and group II subjected to test by utilization of the Digital Occlusal Analyzer System (OccluSense). The occlusal forces distribution, extent and time sequence can then have recorded: Immediately, 6 and 12 months after denture use.
14 studies on the registry are indexed under Tooth Attrition; 5 are open to participants now.
This study's enrollment of 20 is below the median of 26 across 11 interventional studies indexed under Tooth Attrition.
Browse Tooth Attrition studies →Mansoura University is the lead sponsor of 1,119 studies on the registry; 183 are open to participants now.
Of its 9 completed or terminated interventional studies of FDA-regulated products, 0 (0%) have results posted.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
patients will receive maxillary CD and mandibular 2-implant retained overdenture over locator attachment constructed by digital technique.
Device: 3d Printed implant
patients will receive maxillary CD and mandibular 2-implant retained overdenture over locator attachment constructed by conventional technique.
Device: Conventionally constructed implant
Occlusal stability was evaluated using occlusense device by charting amount and distribution of force over dental arch in percentage
Occlusal stability was evaluated using occlusense device by charting amount and distribution of force over dental arch in percentage
occlusal stability
Using occlusense device to determine distribution of occlusal forces over anterior and posterior areas, right and left side through chart representing areas of occlusal contact
Time frame: at time of insertion of prosthesis T(0), 6 months after insertion T(6), 12 months after insertion T(12)
Occlusal analysis
Group I and group II will be subjected to test by utilization of the Digital Occlusal Analyzer System (OccluSense) then amount of occlusal force over each unit presented in percentage
Time frame: at time of insertion of prosthesis T(0), 6 months after insertion T(6), 12 months after insertion T(12)
Plan to share: No
No publications or documents are linked to this record.
Ran from Aug 2022 to primary completion in Sep 2022, 1 month.
How these figures are worked out, and which studies are left out of them.
This study is completed, as verified in Nov 2023. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.