Reducing Vertigo Associated With MRI Machines

An interventional study of Rate of Entry in Vertigo and Dizziness, sponsored by Johns Hopkins University. Recruiting at 1 site in United States. Open to participants aged 18 Years and older, including healthy volunteers. Per ClinicalTrials.gov, last updated 2025-11-12.

Sponsored by Johns Hopkins University · Not applicable, Interventional, and Prevention

From the registry’s dates

  • Started Jan 2024; still recruiting 2 years 9 months later.
Phase
Not applicable
Study type
Interventional
Enrollment
100
Allocation
Randomized
Ages
18 Years and older
Sex
All
01

Study summary

Vertigo, dizziness, and imbalance are commonly reported by patients and technologists when near high-field strength magnets (>4 Tesla, T) used for magnetic resonance imaging (MRI) (1-5) Prior research from the investigators has established that the mechanism is likely a Lorentz force occurring in the inner ear, as a result of interactions with normal electrical currents in the inner ear and the strong static magnetic field of the MRI machine. The investigators have recently developed preliminary data to suggest that slower rates of entry into the magnetic field can greatly attenuate the sensations of vertigo. The explanation for this is that the rates of vestibular adaptation exceed that of the stimulus, allowed a reduction or elimination of the symptoms of vertigo. The aim of this study is to recruit individuals who are already getting an MRI scan as part of other research studies to randomize the rate of entry into and exit from the static magnetic field (i.e., before and after imaging is performed). The usual rate of entry is 20 seconds. This will be increased to one, two or three minutes. The investigators will record subjective sensations of dizziness and vertigo associated with the entry into the MRI.

Read the detailed description

Vertigo and nystagmus are commonly reported in 7 Tesla MRI machines, in upwards of 2/3 of individuals. Magnetic vestibular stimulation (MVS) of the inner ear explains these symptoms. In the normal state, the inner ear has constant electric current flowing from the dark cells to the hair cells of the utricular macula through the potassium enriched endolymph. This electric current drives the utricle's exquisitely sensitive response to linear accelerations. Near the utricular macula are the cupulae of the lateral and superior semicircular canals (SCCs), which are exquisitely sensitive to angular accelerations. Inside an MRI scanner, the electric current entering the utricular macula in each ear interacts with the MRI static magnetic field to create a Lorentz (magneto-hydrodynamic (MHD) force in the endolymph that pushes on the cupulae of the nearby lateral and superior semicircular canals. The force scales linearly with magnetic field strength. Thus, when a human with an intact vestibular system lies in a 7 T MRI magnet, the Lorenz force causes the endolymph to push on the cupulae, changing activity of the angular vestibulo-ocular reflex (VOR) pathway, generating both a transient sensation of motion and a sustained beating of the eyes (nystagmus), with alternating slow phases from the VOR and quick phases that reset the position of the eye.

Adult individuals that are undergoing a 7 Tesla MRI as part of other research protocols at Kennedy-Krieger Kirby Institute, will be recruited. The usual entry into the magnetic field is a button that is pressed, that enters the magnetic field over 20 seconds, and exits the magnetic field over 20 seconds. Each participant will be randomized to one of four groups: 1) entering/exiting at the usual 20 seconds, 2) entering/exiting over 1 minute, 3) entering/exiting over 2 minutes, or 4) entering/exiting over 3 minutes. Participants will be asked to close the eyes during entry and exit. The onset of vertigo and description of the sensation will be recorded. At 15 second intervals, the participants will be asked to rate vertigo on a scale from 0 (no vertigo) to 3 (severe vertigo). The end time of vertigo sensations will also be recorded. The same procedure will be completed when exiting the MRI scan.

02

Conditions studied

  • Vertigo
  • Dizziness

Browse trials for

Keywords

  • MRI
  • 7 Tesla
  • Magnetic Vestibular Stimulation
03

In context

Vertigo

187 studies on the registry are indexed under Vertigo; 27 are open to participants now.

This study's planned enrollment of 100 is above the median of 73 across 138 interventional studies indexed under Vertigo.

Browse Vertigo studies →

Lead sponsor

Johns Hopkins University is the lead sponsor of 1,815 studies on the registry; 315 are open to participants now.

Of its 208 completed or terminated interventional studies of FDA-regulated products, 144 (69%) have results posted.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
Yes

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Participants who will be undergoing an MRI scan at a 7 Tesla MRI.

Exclusion criteria

Exclusion Criteria:

  • Exclusion criteria include pacemaker, defibrillator wires, metal implants, cochlear implants, or ferromagnetic surgical clips in the brain.
  • Pregnancy
  • Claustrophobia occurs in perhaps 5% of patients, and they will not proceed with the test. All subjects will fill out the routine pretesting MRI questionnaire.
05

Study design

Phase
Not applicable
Primary purpose
Prevention
Allocation
Randomized
Intervention model
Parallel assignment
Masking
Single (Participant)
Enrollment
100 participants (estimated)

Study arms

  • No intervention
    Standard Duration

    The participant will undergo an MRI scan using the manufacturer's rate of entry into and exit from the MRI machine. This rate of entry and exit is 20 seconds.

  • Experimental
    1-minute entry

    The participant will undergo an MRI scan using a slower rate of entry than that specified by the manufacturer. This rate of entry is one minute (60 seconds).

    Behavioral: Rate of Entry

  • Experimental
    2-minute entry

    The participant will undergo an MRI scan using a slower rate of entry than that specified by the manufacturer. This rate of entry is two minutes (120 seconds).

    Behavioral: Rate of Entry

  • Experimental
    3-minute entry

    The participant will undergo an MRI scan using a slower rate of entry than that specified by the manufacturer. This rate of entry is three minutes (180 seconds).

    Behavioral: Rate of Entry

Interventions

  • BehavioralRate of Entry

    The participant will enter and exit the MRI scan at a slower rate than the manufacturer entry and exit.

06

What researchers measure

Primary outcomes

  1. Prevalence of vertigo symptoms

    Participants will report the presence and intensity of their vertigo. The presence or absence of vertigo for each group will be the primary outcome.

    Time frame: During MRI up to 6 minutes

Secondary outcomes

  1. Intensity of Vertigo

    Participants will report the intensity of their vertigo symptoms when entering and exiting the MRI scan on a scale from 0 (no vertigo)-3 (severe vertigo) at 15 second intervals. 0=no vertigo, 1=mild vertigo, 2=moderate vertigo, 3=severe vertigo

    Time frame: During MRI up to 6 minutes

  2. Duration (seconds) of Vertigo

    Participants will report the onset and cessation of their vertigo symptoms when entering and exiting the MRI scanner. The duration will be calculated in seconds.

    Time frame: During MRI up to 6 minutes

07

Study locations

1 of 1 sites recruiting
08

References and documents

Publications

  • Mian OS, Li Y, Antunes A, Glover PM, Day BL. Effect of head pitch and roll orientations on magnetically induced vertigo. J Physiol. 2016 Feb 15;594(4):1051-67. doi: 10.1113/JP271513. Epub 2015 Dec 30. PubMed 26614577 ↗
  • Mian OS, Li Y, Antunes A, Glover PM, Day BL. On the vertigo due to static magnetic fields. PLoS One. 2013 Oct 30;8(10):e78748. doi: 10.1371/journal.pone.0078748. eCollection 2013. PubMed 24205304 ↗
  • Roberts DC, Marcelli V, Gillen JS, Carey JP, Della Santina CC, Zee DS. MRI magnetic field stimulates rotational sensors of the brain. Curr Biol. 2011 Oct 11;21(19):1635-40. doi: 10.1016/j.cub.2011.08.029. Epub 2011 Sep 22. PubMed 21945276 ↗
  • Ward BK, Roberts DC, Otero-Millan J, Zee DS. A decade of magnetic vestibular stimulation: from serendipity to physics to the clinic. J Neurophysiol. 2019 Jun 1;121(6):2013-2019. doi: 10.1152/jn.00873.2018. Epub 2019 Apr 10. PubMed 30969883 ↗

Individual participant data

Plan to share: No — Individual participant data will be used only by the investigators participating in this study at Johns Hopkins University School of Medicine.

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Nov 12, 2025, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT06062368
Responsible party
Sponsor
First posted
Oct 2, 2023
Start date
Jan 15, 2024
Primary completion
Jan 1, 2027 (estimated)
Completion
Jan 1, 2028 (estimated)
Last update
Nov 12, 2025

Study contacts

Bryan K Ward, MD
Contact
bryan.k.ward@gmail.com
443-997-6467
Adrian Paez, BA
Contact
paez@kennedykrieger.org
443-923-9200
Bryan Ward, MD
principal investigator · Johns Hopkins University

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

Contact study team

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion