Clinical Investigation of an AcrySof IQ PanOptix Toric Intraocular Lens

An interventional study of ACRYSOF IQ PanOptix Toric Trifocal IOL and Cataract surgery in Aphakia and Corneal Astigmatism, sponsored by Alcon Research. Completed at 1 site in Japan. Open to participants aged 20 Years and older. Per ClinicalTrials.gov, last updated 2022-08-17.

Sponsored by Alcon Research (part of Alcon) · Not applicable, Interventional, and Treatment

Phase
Not applicable
Study type
Interventional
Enrollment
32
Allocation
Not applicable
Ages
20 Years and older
Sex
All
01

Study summary

The purpose of this study is to evaluate the effectiveness and safety of the TFNT20 low cylinder power intraocular lens when implanted in the eye to replace the natural lens following cataract removal.

Read the detailed description

Subjects will attend a total of 5 to 9 visits, depending on whether one eye or both eyes are implanted. The second eye surgery, if applicable, will occur 1 to 30 days after the first eye surgery. Total individual duration of participation will be up to 4 months, including an up to 2-month preoperative period.

This study will be conducted in Japan.

02

Conditions studied

  • Aphakia
  • Corneal Astigmatism

Keywords

  • Cataract
  • Intraocular lens
  • Astigmatism
  • Toric
03

In context

Aphakia

69 studies on the registry are indexed under Aphakia; 6 are open to participants now.

This study's enrollment of 32 is below the median of 103 across 52 interventional studies indexed under Aphakia.

Browse Aphakia studies →

Lead sponsor

Alcon Research is the lead sponsor of 624 studies on the registry; 9 are open to participants now.

Of its 112 completed or terminated interventional studies of FDA-regulated products, 102 (91%) have results posted.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
20 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Eligibility criteria

Key Inclusion Criteria:

  • Eligible to be implanted with AcrySof IQ PanOptix Toric Intraocular Lens Model TFNT20 in at least one eye.
  • Potential postoperative Best Corrected Distance Visual Acuity (BCDVA) of 0.5 decimal or better.
  • Other protocol-specified inclusion criteria may apply.

Key Exclusion Criteria:

  • Irregular corneal astigmatism.
  • History of anterior segment, posterior segment, or optic nerve pathology.
  • History of previous intraocular or corneal (refractive or trauma related) surgery.
  • Any other planned ocular surgical procedures including but not limited to limbal relaxing incision (LRI)/Astigmatic Keratotomy and laser assisted in situ keratomileusis (LASIK).
  • Other protocol-defined exclusion criteria may apply.
05

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
32 participants (actual)

Study arms

  • Experimental
    PanOptix Toric Trifocal IOL

    ACRYSOF IQ PanOptix Toric Trifocal IOL Model TFNT20 implanted in the capsular bag in the posterior chamber following cataract surgery. At least one eye will be implanted.

    Device: ACRYSOF IQ PanOptix Toric Trifocal IOL · Procedure: Cataract surgery

Interventions

  • DeviceACRYSOF IQ PanOptix Toric Trifocal IOL

    Single-piece, ultraviolet and blue-light filtering, foldable, multifocal toric IOL intended to provide vision to aphakic subjects at near, intermediate, and distance and to correct pre-existing corneal astigmatism

    Also known as: PanOptix Toric Trifocal IOL, Model TFNT20

  • ProcedureCataract surgery

    Cataract extraction by phacoemulsification, followed by implantation of the IOL per investigator's standard of care and instructions for use

06

What researchers measure

Primary outcomes

  1. Percentage of Eyes With ≤ 0.25 Diopter (D) Absolute Refractive Cylinder at Visit 3/3A (Day 30-60)

    A manifest refraction (manual vision test) was conducted using charts. Refractive cylinder is the amount of power in diopters that is needed to correct any remaining astigmatism.

    Time frame: Day 30-60 postoperative

Secondary outcomes

  1. Percentage of Eyes With ≤ 0.5 Diopter (D) Absolute Refractive Cylinder at Visit 3/3A (Day 30-60)

    A manifest refraction (manual vision test) was conducted using charts. Refractive cylinder is the amount of power in diopters that is needed to correct any remaining astigmatism. No confirmatory statistical hypothesis testing was pre-specified in the protocol.

    Time frame: Day 30-60 postoperative

  2. Average Absolute Manifest Refractive Cylinder at Visit 3/3A (Day 30-60)

    A manifest refraction (manual vision test) was conducted using charts. Refractive cylinder is the amount of power in diopters that is needed to correct any remaining astigmatism. No confirmatory statistical hypothesis testing was pre-specified in the protocol.

    Time frame: Day 30-60 postoperative

07

Results

Posted Aug 17, 2022

Participant flow

Subjects were recruited from 1 investigative site located in Japan.

Participant flow — Overall Study
MilestonePanOptix Toric Trifocal IOL
Started32
Attempted implantation32
Successful implantation32
Completed32
Not completed0

Outcome measures

PrimaryPercentage of Eyes With ≤ 0.25 Diopter (D) Absolute Refractive Cylinder at Visit 3/3A (Day 30-60)

A manifest refraction (manual vision test) was conducted using charts. Refractive cylinder is the amount of power in diopters that is needed to correct any remaining astigmatism.

Time frame:
Day 30-60 postoperative
Reported as:
Number · percentage of eyes
Percentage of Eyes With ≤ 0.25 Diopter (D) Absolute Refractive Cylinder at Visit 3/3A (Day 30-60)
percentage of eyesPanOptix Toric Trifocal IOL
Percentage of Eyes With ≤ 0.25 Diopter (D) Absolute Refractive Cylinder at Visit 3/3A (Day 30-60)90.2
Statistical analysis
  • PanOptix Toric Trifocal IOL · Exact Test of Binomial Proportion · p = <0.0001
SecondaryPercentage of Eyes With ≤ 0.5 Diopter (D) Absolute Refractive Cylinder at Visit 3/3A (Day 30-60)

A manifest refraction (manual vision test) was conducted using charts. Refractive cylinder is the amount of power in diopters that is needed to correct any remaining astigmatism. No confirmatory statistical hypothesis testing was pre-specified in the protocol.

Time frame:
Day 30-60 postoperative
Reported as:
Number · percentage of eyes
Percentage of Eyes With ≤ 0.5 Diopter (D) Absolute Refractive Cylinder at Visit 3/3A (Day 30-60)
percentage of eyesPanOptix Toric Trifocal IOL
Percentage of Eyes With ≤ 0.5 Diopter (D) Absolute Refractive Cylinder at Visit 3/3A (Day 30-60)100
SecondaryAverage Absolute Manifest Refractive Cylinder at Visit 3/3A (Day 30-60)

A manifest refraction (manual vision test) was conducted using charts. Refractive cylinder is the amount of power in diopters that is needed to correct any remaining astigmatism. No confirmatory statistical hypothesis testing was pre-specified in the protocol.

Time frame:
Day 30-60 postoperative
Reported as:
Mean · diopter
Average Absolute Manifest Refractive Cylinder at Visit 3/3A (Day 30-60)
diopterPanOptix Toric Trifocal IOL
Average Absolute Manifest Refractive Cylinder at Visit 3/3A (Day 30-60)0.055 ± 0.153

Adverse events

Collected over Adverse events (AEs) were collected pre-treatment (Day -60 to 0) up to Day 30-60 post-treatment/study exit. AEs were obtained through solicited and spontaneous comments from subjects and through observations by the Investigator.. Non-serious events are listed at a 5% frequency threshold.

Adverse event summary by group
GroupDeathsSeriousOther
Pretreatment0/32 (0%)0/32 (0%)0/32 (0%)
TFNT20 Ocular / First Eye0/32 (0%)0/32 (0%)5/32 (15.6%)
TFNT20 Ocular / Second Eye0/9 (0%)0/9 (0%)1/9 (11.1%)
TFNT20 Nonocular / Systemic0/32 (0%)0/32 (0%)0/32 (0%)
Most frequent other events
Most frequent other events
EventPretreatmentTFNT20 Ocular / First EyeTFNT20 Ocular / Second EyeTFNT20 Nonocular / Systemic
Intraocular pressure increasedInvestigations0/325/321/90/32

Baseline characteristics

All Implanted Analysis Set: All eyes with successful test article implantation

Age, Continuous
Age, Continuous(years)PanOptix Toric Trifocal IOL
Mean65.2 ± 9.4
Age, Customized
Age, Customized(participants)PanOptix Toric Trifocal IOL
Less than 60 years8
60-69 years10
70-79 years13
80 years and older1
Sex: Female, Male
Sex: Female, Male(Participants)PanOptix Toric Trifocal IOL
Female25
Male7
Race/Ethnicity, Customized
Race/Ethnicity, Customized(participants)PanOptix Toric Trifocal IOL
Japanese32
Region of Enrollment
Region of Enrollment(participants)PanOptix Toric Trifocal IOL
Japan32
08

Study locations

1 site
  • Alcon Investigative Site
    Chiyoda-Ku, Tokyo 101-0061, Japan
09

References and documents

Study documents

PDFs hosted by the registry, ClinicalTrials.gov.

Individual participant data

Plan to share: No

10

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Aug 17, 2022, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
11

Registry details

Key details

Study ID
NCT04542525
Lead sponsor
Alcon Research
Responsible party
Sponsor
First posted
Sep 9, 2020
Start date
Dec 1, 2020
Primary completion
Aug 10, 2021
Completion
Aug 10, 2021
Results posted
Aug 17, 2022
Last update
Aug 17, 2022

Study contacts

Sr. Clinical Trial Lead, CDMA Surgical
study director · Alcon Japan Limited

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Jul 2022. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion