An interventional study of Thermal stress and performance using a pre-cooling protocol and Thermal stress and performance without a pre-cooling protocol in Risk of Heat Stress, sponsored by Petros Dinas. Completed at 1 site in Greece. Open to participants aged 14 Years to 17 Years, including healthy volunteers. Per ClinicalTrials.gov, last updated 2019-12-13.
Sponsored by Petros Dinas · Not applicable, Interventional, and Prevention
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Many tennis tournaments are played outdoors in hot and humid conditions, which poses a significant challenge particularly for children athletes. The purpose of this investigation is to examine if a precooling method can reduce thermal strain and consequently improve the performance of adolescent tennis athletes while exercising in hot conditions.
Matches were conducted on hard-court surfaces separated by 24h (n=4 pairs) or 144h (n=1pair) between 9am and 6pm and were played in winning two sets. Participants were paired according to their level of play and competed against the same component at the same time of the day in both matches.
Three hours before the start of their scheduled match, each player ingested a telemetric pill in order to estimate the visceral temperature. Upon arrival, all participants provided a urine sample for assessment of urine specific gravity as an indicator of their hydration status and they emptied their bladders before were weighed. They were weighed twice, at baseline and at the end of the match with a precision weight scale (Kern DE 150K2D, KERN \& SOHN GmbH, Balingen, Germany). During the match the participants consumed water and any other sport drink and food ad libitum. The total weight of the players' food and fluids that was consumed was measured using a precision weight scale. If participants wished to urinate during the match, they were asked to use a urine cup and their urine was weighed.
One hour before the match, the precooling group was wearing a Cooling Cap (WElkins Sideline Cooling System, SCS) for 45 minutes. On removal from a -20oC freezer, the cap surface was 10.7±2.5oC. After 45 minutes, participants removed the cap and they performed a 5 minutes standardized warm-up (running around the court and running exercises from baseline to net and back to baseline) and 10 min tennis specific warm up (rallies and serves) on court. Each participant, before the warm-up, was outfitted with a heart rate chest strap and iBUTTON sensors at four sites of the body (chest, upper arm, thigh and calf).
The scoring and timing characteristics of the matches complied with 2016 ITF rules. Three new balls were used for each match with the players retrieving balls between points. Matches were filmed from one end of the court, using a digital video camera (Sony DCR-VX2000E PAL, Japan). Participants were performed on perceptual measurements at baseline, after each set, and at the end of the match.
Thermoregulatory, cardiovascular and perceptual responses were recorded with standardized techniques: 1) visceral temperature using telemetric pill (BodyCap, Caen, France) was continuously recorded throughout the match; 2) skin temperature using iBUTTON sensors (type DS1921 H, Maxim/Dallas Semiconductor Corp., USA) on chest, upper arm, thigh and calf was recorded continuously; 3) heart rate (HR) variability data were sampled through short-range telemetry at 1,000 Hz with a Polar RS800CX (Polar Electro , Kempele, Finland). The heart rate monitor signal will be transferred to the Polar Precision Performance Software (release 3.00; Polar Electro Oy); 4) thermal comfort (scale 1-5), thermal sensation (scale 1-10) and rating of perceived exertion using standardized questionnaires were recorded at baseline, after each set, and at the end of the match.
Hydration status was recorded with urine specific gravity. All the collected urine samples will be analyzed using a refractrometer (Atago, Tokyo, Japan) for the determination of urine specific gravity. Euhydration will be defined as urine specific gravity \<1.02 according to internationally accepted standards.
A digital video camera (Sony DCR-VX2000E PAL, Japan) was used to record the match - play characteristics. The footage was used to conduct the retrospective notational analysis. The quantitative performance indices that assessed had been: games and points won in each set and normalized to the number of games and points that record in each set respectively. Also unforced errors, first and second serve accuracy, aces, shots per rally and direction changes in each point calculated. Point's duration, between point-duration as well the effective point time calculated. The effective point time starting with the ball toss of the serve and ending when the ball passed the player or bounced twice on court. In case of double fault, starting time recorded from the beginning of the second serve.
Environmental data including air temperature, relative humidity, and wind speed were measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA). The weather station was placed 1 meter above the ground according to the manufacturer's guidelines.
118 studies on the registry are indexed under Heat Stress Disorders; 42 are open to participants now.
This study's enrollment of 8 is below the median of 24 across 104 interventional studies indexed under Heat Stress Disorders.
Browse Heat Stress Disorders studies →Petros Dinas is the lead sponsor of 10 studies on the registry; none are open to participants now.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
One hour before a tennis match, the pre-cooling group was wearing a Cooling Cap (WElkins Sideline Cooling System, SCS) for 45 minutes.
Behavioral: Thermal stress and performance using a pre-cooling protocol
Participants were monitored during a usual game without any kind of pre-cooling strategy
Biological: Thermal stress and performance without a pre-cooling protocol
One hour before a tennis match, participants were wearing a Cooling Cap (WElkins Sideline Cooling System, SCS) for 45 minutes. During the tennis match the following variables were monitored: heart rate, core temperature, skin temperature, thermal sensation and comfort, rating of perceived exertion and hydration status.
During a tennis match the following variables were monitored: heart rate, core temperature, skin temperature, thermal sensation and comfort, rating of perceived exertion and hydration status.
Heart rate
Heart rate data were continuously monitored using a Polar Team system (Polar® Team 2, Polar Electro Oy, Kempele, Finland
Time frame: Up to 4 hours, during a one complete tennis match
Core temperature
Visceral temperature was continuously recorded throughout the match using telemetric pills (BodyCap, Caen, France)
Time frame: Up to 4 hours, during a one complete tennis match
Skin temperature
Skin temperature was continuously recorded throughout the match using iBUTTON sensors (type DS1921 H, Maxim/Dallas Semiconductor Corp., USA)
Time frame: Up to 4 hours, during a one complete tennis match
Change from baseline thermal comfort at after each set
Thermal comfort was assessed via the thermal comfort scale (1 = comfortable; 5 = extremely uncomfortable).
Time frame: Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match
Change from baseline thermal sensation at after each set
Thermal sensation was assessed via the thermal sensation scale (-3 = cold; +3 = hot)
Time frame: Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match
Change from baseline rating of perceived exertion at after each set
We used the Borg 20th Scale (6 = no exertion at all; 20 = maximal exertion)
Time frame: Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match
Change from baseline urine specific gravity (hydration status) at the end of each match
Urine samples was obtained to evaluate the urine specific gravity. Urine specific gravity (single assessmentno units) was assessed using a refractometer (PAL-10S, ATAGO CO., LTD., Fukaya, Saitama Prefecture, Japan). Urine color was assessed using a urine color scale
Time frame: Change from baseline up to 4 hours at the end of the tennis match
Match - play characteristics (i.e., performance)
They were recorded by analyzing the video footage from the match. The quantitative performance indices assessed were: games and points won in each set and normalized to the number of games and points recorded in each set, respectively. Unforced errors, first and second serve accuracy, aces, shots per rally and direction changes in each point calculated. Point's duration, between point-duration as well the effective point time calculated. The effective point time starting with the ball toss of the serve and ending when the ball passed the player or bounced twice on court. In case of double fault, starting time recorded from the beginning of the second serve.
Time frame: Up to 4 hours, during a one complete tennis match
Air temperature
It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's
Time frame: Up to 4 hours, during a one complete tennis match
Relative humidity
It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's guidelines
Time frame: Up to 4 hours, during a one complete tennis match
Wind speed
It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's guidelines
Time frame: Up to 4 hours, during a one complete tennis match
Solar radiation
It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's guidelines. Solar radiation is measured directly by the device of portable weather station.
Time frame: Up to 4 hours, during a one complete tennis match
Plan to share: Undecided
Ran from Aug 2018 to primary completion in Sep 2018, 1 month.
Of 77 non-industry interventional studies with no phase under Heat Stress Disorders, half reached primary completion within 14 months of starting (the median), counting those still running; a quarter within 5 and three quarters within 27. This study's 1 month is below that.
Counting every sponsor, half of 77 studies reached it within 14 months; a quarter within 5 and three quarters within 27.
How these figures are worked out, and which studies are left out of them.
This study is completed, as verified in Dec 2019. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Petros Dinas