Heart Rate Assessment at Birth Comparing Stethoscope Versus Tap-based Application

An interventional study of Heart rate assessment using the Neonatal Resuscitation Program 6-sec assessment method and Heart rate assessment using Tap-based smartphone application in Asphyxia Neonatorum and Birth Asphyxia, sponsored by University of Alberta. Withdrawn at 1 site in Canada. Open to participants aged Up to 5 Minutes. Per ClinicalTrials.gov, last updated 2024-09-19.

Sponsored by University of Alberta · Not applicable, Interventional, and Diagnostic

Why this study was withdrawn
No funding obtained
Phase
Not applicable
Study type
Interventional
Enrollment
0
Allocation
Randomized
Ages
Up to 5 Minutes
Sex
All
01

Study summary

Some newborn babies have difficulty breathing at birth and need help. When babies need help with breathing the clinical team, the team measures heart rate using a stethoscope to check its heart rate and figure out what kind of help they will need. If the heart rate is too low, the clinical team will begin to inflate the baby's lung. Knowing the baby's heart rate quickly is important but the stethoscope is inaccurate, and might delay start of resuscitation. Using a smartphone app that uses screen tapping with a stethoscope could allow heart rate to be measured much faster compared to the stethoscope and allow the clinical team to support the baby's needs better immediately after birth.

Read the detailed description

Purpose

Nearly 10% of all infants born worldwide require respiratory support at birth and birth asphyxia remains one of the leading causes of infant morbidity and mortality. Neonatal resuscitation is the most effective strategy to deal with this condition. Moreover, an infant's heart rate (HR) is the most significant clinical parameter used to assess the need for and response to neonatal resuscitation. Currently, a newborn's HR is determined by auscultating or palpating of the umbilical cord. Although auscultation is more precise compared to palpation, both methods are inaccurate and tend to underestimate HR. The current resuscitation guidelines also recommend using electrocardiogram (ECG) and pulse oximetry, which allow for continuous monitoring, however are slow to apply and detect HR compared to stethoscopes. During neonatal resuscitation, an infant's HR is necessary to initiate resuscitation and to monitor the effectiveness of each intervention and therefore it becomes essential to accurately and quickly assess an infant's HR during this process. If HR is detected slowly or inaccurately, there is an increased risk that necessary interventions are not started or that certain interventions are prolonged, which could lead to increased morbidity and mortality of the infants. The recent advances in technology, namely the development of a smartphone tap application for HR assessment is promising as a novel tool for quick and accurate HR detection during neonatal resuscitation.

Hypothesis

The use of a tap-based smartphone application will be faster and more accurate when compared to standard auscultation with the 6-sec method to assess HR.

Justification

Simulation studies have shown that it is feasible to measure HR using a tap-based application. Moreover, the investigator's group has recently shown its reliability in an animal model of asphyxia-induced neonatal swine. The investigator showed its accuracy compared to the experimental gold standard carotid blood flow-derived HR assessments and report a median time of 3 sec for assessment, which is less than the current recommended time for auscultation. However, no study has been performed in the delivery room in newborn babies at birth. Therefore, the investigator aim to compare the tap-based application to the current 6-sec standard approach to assess HR during neonatal resuscitation in the delivery room. Ehe investigator anticipate this study will allow us to determine the most reliable approach for initial assessment to reduce neonatal morbidity and mortality outcomes.

Objectives

To examine (i) accuracy and (ii) speed to assess HR using auscultation with a tap-based application during neonatal resuscitation.

Research Method/Procedures

The proposed study is a randomized controlled trial comparing two different approaches to accurately assess HR. The investigator will compare the routinely used Neonatal Resuscitation Program 6-sec method with a stethoscope using two different methods of auscultation [6-sec method and tap-based method (NeoTapLS, Tap4Life, Stockholm, Sweden)] to accurately assess HR immediately after birth. The investigator aim to collect the data over a period of 12 months.

Two investigators in addition to the clinical team will attend the delivery of newborn infants. Immediately after birth the infant will be placed on a resuscitation trolley where a pulse oximeter will be attached to the right hand. At the same time three ECG leads will be placed on the infant's chest. Simultaneously the stethoscope will be placed by one of the investigators on the infants' chest to obtain the HR . In the alternative setup, stethoscope will be used in combination with the tap-based application.

In both setups, the time needed to display a HR will be recorded for all devices. All infants will have routine HR measured using ECG, which will be used as comparison for accuracy

02

Conditions studied

  • Asphyxia Neonatorum
  • Birth Asphyxia

Browse trials for

Keywords

  • Newborn
  • Heart rate assessment
  • Delivery Room
03

In context

Asphyxia Neonatorum

113 studies on the registry are indexed under Asphyxia Neonatorum; 24 are open to participants now.

Browse Asphyxia Neonatorum studies →

Lead sponsor

University of Alberta is the lead sponsor of 819 studies on the registry; 166 are open to participants now.

Of its 5 completed or terminated interventional studies of FDA-regulated products, 3 (60%) have results posted.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
Up to 5 Minutes
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • All newborn infants delivered in the Royal Alexandra Hospital (RAH) 22+0-41+6 weeks gestation.

Exclusion criteria

Exclusion Criteria:

  • Infants will be excluded if parents refused to consent to the study.
05

Study design

Phase
Not applicable
Primary purpose
Diagnostic
Allocation
Randomized
Intervention model
Parallel assignment
Masking
Single (Outcomes assessor)
Enrollment
0 participants (actual)

Study arms

  • Active comparator
    Control group

    Heart rate assessment using the Neonatal Resuscitation Program 6-sec assessment method At birth, the clinical team will place the stethoscope on the infant chest and calculate heart rate by listening to the heart beat for 6-sec and then compute the heart rate of the newborn infant.

    Device: Heart rate assessment using the Neonatal Resuscitation Program 6-sec assessment method

  • Experimental
    Intervention group

    Heart rate assessment using Tap-based smartphone application At birth, the clinical team will place the stethoscope on the infant chest and calculate heart rate using a Tap-based smartphone application by tapping the screen for 3 beats at that time a heart rate will be displayed.

    Device: Heart rate assessment using Tap-based smartphone application

Interventions

  • DeviceHeart rate assessment using the Neonatal Resuscitation Program 6-sec assessment method

    Heart rate assessment using the Neonatal Resuscitation Program 6-sec assessment method At birth, the clinical team will place the stethoscope on the infant chest and calculate heart rate by listening to the heart beat for 6-sec and then compute the heart rate of the newborn infant.

  • DeviceHeart rate assessment using Tap-based smartphone application

    At birth, the clinical team will place the stethoscope on the infant chest and calculate heart rate using a Tap-based smartphone application by tapping the screen for 3 beats at that time a heart rate will be displayed.

06

What researchers measure

Primary outcomes

  1. Time to obtain Heart rate

    Time to obtain Heart rate form birth

    Time frame: within the first 60 seconds form birth

Secondary outcomes

  1. Accuracy of heart rate assessment using either technique

    Accuracy of heart rate assessment using tap-based application or 6-sec method

    Time frame: within the first 60 seconds form birth

07

Study locations

1 site
  • Royal Alexandra Hospital
    Edmonton, Alberta T5H 3V9, Canada
08

References and documents

Publications

  • Saugstad OD, Ramji S, Rootwelt T, Vento M. Response to resuscitation of the newborn: early prognostic variables. Acta Paediatr. 2005 Jul;94(7):890-5. doi: 10.1111/j.1651-2227.2005.tb02007.x. PubMed 16188811 ↗
  • Wyckoff MH, Aziz K, Escobedo MB, Kapadia VS, Kattwinkel J, Perlman JM, Simon WM, Weiner GM, Zaichkin JG. Part 13: Neonatal Resuscitation: 2015 American Heart Association Guidelines Update for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2015 Nov 3;132(18 Suppl 2):S543-60. doi: 10.1161/CIR.0000000000000267. No abstract available. PubMed 26473001 ↗
  • Duryea EL, Nelson DB, Wyckoff MH, Grant EN, Tao W, Sadana N, Chalak LF, McIntire DD, Leveno KJ. The impact of ambient operating room temperature on neonatal and maternal hypothermia and associated morbidities: a randomized controlled trial. Am J Obstet Gynecol. 2016 Apr;214(4):505.e1-505.e7. doi: 10.1016/j.ajog.2016.01.190. Epub 2016 Feb 10. PubMed 26874298 ↗
  • Kamlin CO, O'Donnell CP, Everest NJ, Davis PG, Morley CJ. Accuracy of clinical assessment of infant heart rate in the delivery room. Resuscitation. 2006 Dec;71(3):319-21. doi: 10.1016/j.resuscitation.2006.04.015. Epub 2006 Sep 20. PubMed 16989935 ↗
  • Kamlin CO, Dawson JA, O'Donnell CP, Morley CJ, Donath SM, Sekhon J, Davis PG. Accuracy of pulse oximetry measurement of heart rate of newborn infants in the delivery room. J Pediatr. 2008 Jun;152(6):756-60. doi: 10.1016/j.jpeds.2008.01.002. Epub 2008 Mar 6. PubMed 18492509 ↗
  • Kopotic RJ, Lindner W. Assessing high-risk infants in the delivery room with pulse oximetry. Anesth Analg. 2002 Jan;94(1 Suppl):S31-6. PubMed 11900034 ↗
  • Luong DH, Cheung PY, O'Reilly M, Lee TF, Schmolzer GM. Electrocardiography vs. Auscultation to Assess Heart Rate During Cardiac Arrest With Pulseless Electrical Activity in Newborn Infants. Front Pediatr. 2018 Nov 27;6:366. doi: 10.3389/fped.2018.00366. eCollection 2018. PubMed 30538976 ↗
  • Patel S, Cheung PY, Solevag AL, Barrington KJ, Kamlin COF, Davis PG, Schmolzer GM. Pulseless electrical activity: a misdiagnosed entity during asphyxia in newborn infants? Arch Dis Child Fetal Neonatal Ed. 2019 Mar;104(2):F215-F217. doi: 10.1136/archdischild-2018-314907. Epub 2018 Jun 12. PubMed 29895572 ↗
  • Owen CJ, Wyllie JP. Determination of heart rate in the baby at birth. Resuscitation. 2004 Feb;60(2):213-7. doi: 10.1016/j.resuscitation.2003.10.002. PubMed 15036740 ↗
  • Voogdt KG, Morrison AC, Wood FE, van Elburg RM, Wyllie JP. A randomised, simulated study assessing auscultation of heart rate at birth. Resuscitation. 2010 Aug;81(8):1000-3. doi: 10.1016/j.resuscitation.2010.03.021. Epub 2010 May 18. PubMed 20483522 ↗
  • Binotti M, Cavallin F, Ingrassia PL, Pejovic NJ, Monzani A, Genoni G, Trevisanuto D. Heart rate assessment using NeoTapAdvancedSupport: a simulation study. Arch Dis Child Fetal Neonatal Ed. 2019 Jul;104(4):F440-F442. doi: 10.1136/archdischild-2018-315408. Epub 2018 Sep 27. PubMed 30262463 ↗

Individual participant data

Plan to share: Yes — requests can be made to the PI

Supporting information: Study protocol, Statistical analysis plan, Informed consent form, Clinical study report, Analytic code

Time frame: once study is completed and published

Access criteria: email requests to the PI

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Sep 19, 2024, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT03913533
Responsible party
Sponsor
First posted
Apr 12, 2019
Start date
Dec 16, 2019
Primary completion
Apr 30, 2021 (estimated)
Completion
Oct 31, 2021 (estimated)
Last update
Sep 19, 2024

Study contacts

Georg Schmolzer, MD, PhD
principal investigator · University of Alberta

Oversight

FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is withdrawn, as verified in Sep 2021. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion