An interventional study of ECIG Lab Session 15 watts, 10 mg nicotine and ECIG Lab Session 15 watts, 15 mg nicotine in Electronic Cigarettes, sponsored by Virginia Commonwealth University. Completed at 1 site in United States. Open to participants aged 18 Years to 55 Years, including healthy volunteers. Per ClinicalTrials.gov, last updated 2022-10-06.
Sponsored by Virginia Commonwealth University · Not applicable, Interventional, and Basic science
The purpose of this research study is to find out how different types of electronic cigarettes (ECIG) settings, combined with e-liquids of differing nicotine concentrations, affect blood nicotine levels, use behavior (how users puff), and how users feel.
172 studies on the registry are indexed under Vaping; 75 are open to participants now.
This study's enrollment of 45 is below the median of 105 across 144 interventional studies indexed under Vaping.
Browse Vaping studies →Virginia Commonwealth University is the lead sponsor of 648 studies on the registry; 82 are open to participants now.
Of its 90 completed or terminated interventional studies of FDA-regulated products, 64 (71%) have results posted.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Some study details about the eligibility criteria are purposely omitted at this time to preserve scientific integrity. Full details will be posted at the conclusion of the study.
Other: ECIG Lab Session 15 watts, 10 mg nicotine · Other: ECIG Lab Session 15 watts, 15 mg nicotine · Other: ECIG Lab Session 15 watts, 30 mg nicotine · Other: ECIG Lab Session 30 watts, 10 mg nicotine · Other: ECIG Lab Session 30 watts, 15 mg nicotine · Other: ECIG Lab Session 30 watts, 30 mg nicotine
Other: ECIG Lab Session 15 watts, 10 mg nicotine · Other: ECIG Lab Session 15 watts, 15 mg nicotine · Other: ECIG Lab Session 15 watts, 30 mg nicotine · Other: ECIG Lab Session 30 watts, 10 mg nicotine · Other: ECIG Lab Session 30 watts, 15 mg nicotine · Other: ECIG Lab Session 30 watts, 30 mg nicotine
During each session, participants will first complete a 10-puff product use bout, and then a 90-minute ad lib product use bout.
During each session, participants will first complete a 10-puff product use bout, and then a 90-minute ad lib product use bout.).
During each session, participants will first complete a 10-puff product use bout, and then a 90-minute ad lib product use bout.
During each session, participants will first complete a 10-puff product use bout, and then a 90-minute ad lib product use bout.
During each session, participants will first complete a 10-puff product use bout, and then a 90-minute ad lib product use bout.
During each session, participants will first complete a 10-puff product use bout, and then a 90-minute ad lib product use bout.
Change in Plasma Nicotine
Change in plasma nicotine level.
Time frame: Baseline to 5 min after the start of a 10-puff product use
Puff Volume
The average volume of each puff, in ml, during 10 puff bout.
Time frame: Each time the e-cigarette is used during the 10-puff use bout - 5 minutes
Puff Duration
The average duration of each puff, in seconds.
Time frame: Each time the e-cigarette is used during the 10-puff use bout - 5 minutes
Heart Rate
Average heart rate, measured in beats per minute.
Time frame: Heart rate will be measured from baseline continuously throughout the 10-puff bout - 5 minutes
Inter Puff Interval
The time between each puff, in seconds
Time frame: Inter puff interval will be measured each time the e-cigarette is used during an approximately 4 hour session: during a 5-minute 10-puff use bout, and during an approximately 90 minute ad lib use period
Flow Rate
The rate of air flow during each puff, in ml/second
Time frame: Flow rate will be measured each time the e-cigarette is used during an approximately 4 hour session: during a 5-minute 10-puff use bout, and during an approximately 90 minute ad lib use period
Hughes-Hatsukami Questionnaire
This scale is used to assess the extent to which product use reduces tobacco abstinence symptoms, and consists of 11 items scored 0 - 100, with lower scores indicating less severe symptoms. There are no sub-scales. Items are analyzed separately.
Time frame: Questionnaire will be administered 4 times in each each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.
Direct Effects of Product Use Questionnaire
This scale is used to assess how product use makes participants feel and consists of 10 questions that are scored 0 - 100. There are no sub-scales. Items are analyzed separately.
Time frame: Questionnaire will be administered 2 times in each each approximately 4-hr session: 10 minutes after the start of a 10-puff use bout, and then after an approximately 1-hour ad lib use period.
Direct Effects of Nicotine Questionnaire
This scale is used to assess how product use makes participants feel, and consists of 10 questions that are scored 0 - 100.There are no sub-scales. Items are analyzed separately.
Time frame: Questionnaire will be administered 4 times in each each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.
Carbon Monoxide Levels
Change in carbon monoxide levels (in parts per mission)
Time frame: Carbon monoxide levels will be assessed before and after product use in each approximately 4-hr session: at baseline, 5 min after the end of a 10-puff product use, and then before and after an approximately 1-hour ad lib use period.
Blood Pressure
Change in blood pressure, measured in mm/hg
Time frame: Blood pressure will be measured from baseline continuously throughout each approximately 4-hr session
General Labeled Magnitude Scale
This scale measures the flavor sensation, harshness, and throat hit (in three questions that correspond to those constructs) of the e-cigarette used in each session. The scale ranges from 0 - 100, with 0 being no sensation and 100 being the strongest imaginable sensation of any kind. Each item if scored nd analyzed separately (there are no sub-scales).
Time frame: The General Labeled Magnitude Scale will be administered twice in each approximately 4 hour session--after a 5-minute 10 puff use bout, and after the approximately 90 minute ad lib period.
Not-completed reason was not stored by treatment arm
| Milestone | Cigarette Smokers | E-cigarette Users |
|---|---|---|
| Started | 22 | 23 |
| Session 1: ecig lab session 15 watts, 10 mg nicotine | 12 | 15 |
| Session 2: ecig lab session 15 watts, 15 mg nicotine | 12 | 15 |
| Session 3: ecig lab session 15 watts, 30 mg nicotine | 12 | 15 |
| Session 4: ecig lab session 30 watts, 10 mg nicotine | 12 | 15 |
| Session 5: ecig lab session 30 watts, 15 mg nicotine | 12 | 15 |
| Session 6: ecig lab session 30 watts, 30 mg nicotine | 12 | 15 |
| Completed | 12 | 15 |
| Not completed | 10 | 8 |
| Withdrew: Lost to follow up, study stopped due to covid-19, other reasons | 10 | 8 |
Change in plasma nicotine level.
| ng/ml | Cigarette Smokers | E-cigarette Users |
|---|---|---|
| 10mg 15 Watts | 8.68 ± 7.22 | 8.28 ± 9.65 |
| 10mg 30 Watts | 9.53 ± 7.53 | 12.00 ± 10.29 |
| 15mg 15 Watts | 7.34 ± 6.19 | 7.17 ± 6.14 |
| 15mg 30 Watts | 13.04 ± 13.14 | 14.04 ± 12.08 |
| 30mg 15 Watts | 10.18 ± 9.28 | 20.12 ± 22.40 |
| 30mg 30 Watts | 17.28 ± 18.05 | 22.38 ± 21.04 |
The average volume of each puff, in ml, during 10 puff bout.
| ml | Cigarette Smokers | E-cigarette Users |
|---|---|---|
| 10 mg, 15 Watts | 457.27 ± 223.02 | 748.34 ± 412.22 |
| 10 mg, 30 Watts | 245.11 ± 124.09 | 503.43 ± 216.28 |
| 15 mg, 15 Watts | 350.18 ± 190.97 | 708.62 ± 300.45 |
| 15 mg, 30 Watts | 217.01 ± 94.99 | 409.56 ± 208.61 |
| 30 mg, 15 Watts | 310.95 ± 199.06 | 631.23 ± 225.84 |
| 30 mg, 30 Watts | 176.32 ± 79.76 | 415.85 ± 186.33 |
The average duration of each puff, in seconds.
| seconds | Cigarette Smokers | E-cigarette Users |
|---|---|---|
| 10 mg, 15 W | 3.04 ± 1.01 | 4.37 ± 1.15 |
| 10 mg, 30 W | 1.97 ± 0.65 | 2.83 ± 0.71 |
| 15 mg, 15 W | 2.59 ± 0.53 | 4.02 ± 1.27 |
| 15 mg, 30 W | 1.65 ± 0.43 | 2.72 ± 1.05 |
| 30 mg, 15 W | 2.44 ± 0.83 | 3.41 ± 1.01 |
| 30 mg, 30 W | 1.58 ± 0.45 | 2.45 ± 0.84 |
Average heart rate, measured in beats per minute.
| bpm | Cigarette Smokers | E-cigarette Users |
|---|---|---|
| 10 mg, 15 Watts | 75.66 ± 6.88 | 75.01 ± 10.44 |
| 10 mg, 30 Watts | 78.19 ± 7.25 | 79.92 ± 15.30 |
| 15 mg, 15 Watts | 72.64 ± 6.32 | 79.09 ± 15.30 |
| 15 mg, 30 Watts | 76.05 ± 6.91 | 80.27 ± 12.51 |
| 30 mg, 15 Watts | 77.12 ± 8.83 | 78.56 ± 12.67 |
| 30 mg, 30 Watts | 80.12 ± 8.95 | 84.51 ± 14.79 |
The time between each puff, in seconds
Results for this outcome have not been posted.
The rate of air flow during each puff, in ml/second
Results for this outcome have not been posted.
This scale is used to assess the extent to which product use reduces tobacco abstinence symptoms, and consists of 11 items scored 0 - 100, with lower scores indicating less severe symptoms. There are no sub-scales. Items are analyzed separately.
Results for this outcome have not been posted.
This scale is used to assess how product use makes participants feel and consists of 10 questions that are scored 0 - 100. There are no sub-scales. Items are analyzed separately.
Results for this outcome have not been posted.
This scale is used to assess how product use makes participants feel, and consists of 10 questions that are scored 0 - 100.There are no sub-scales. Items are analyzed separately.
Results for this outcome have not been posted.
Change in carbon monoxide levels (in parts per mission)
Results for this outcome have not been posted.
Change in blood pressure, measured in mm/hg
Results for this outcome have not been posted.
This scale measures the flavor sensation, harshness, and throat hit (in three questions that correspond to those constructs) of the e-cigarette used in each session. The scale ranges from 0 - 100, with 0 being no sensation and 100 being the strongest imaginable sensation of any kind. Each item if scored nd analyzed separately (there are no sub-scales).
Results for this outcome have not been posted.
Collected over During each of 6 approximately 4-hour session over up to a 3 week period.. Non-serious events are listed at a 5% frequency threshold.
| Group | Deaths | Serious | Other |
|---|---|---|---|
| Cigarette Smokers | 0/12 (0%) | 0/12 (0%) | 0/12 (0%) |
| E-cigarette Users | 0/15 (0%) | 0/15 (0%) | 0/15 (0%) |
| Age, Categorical(Participants) | Cigarette Smokers | E-cigarette Users | Total |
|---|---|---|---|
| <=18 years | 0 | 0 | 0 |
| Between 18 and 65 years | 12 | 15 | 27 |
| >=65 years | 0 | 0 | 0 |
| Age, Continuous(years) | Cigarette Smokers | E-cigarette Users | Total |
|---|---|---|---|
| Mean | 33.67 ± 8.74 | 25.40 ± 7.94 | 29.07 ± 9.15 |
| Sex/Gender, Customized(Participants) | Cigarette Smokers | E-cigarette Users | Total |
|---|---|---|---|
| Female | 4 | 7 | 11 |
| Male | 7 | 8 | 15 |
| Other | 1 | 0 | 1 |
| Race (NIH/OMB)(Participants) | Cigarette Smokers | E-cigarette Users | Total |
|---|---|---|---|
| American Indian or Alaska Native | 0 | 0 | 0 |
| Asian | 0 | 1 | 1 |
| Native Hawaiian or Other Pacific Islander | 0 | 0 | 0 |
| Black or African American | 4 | 2 | 6 |
| White | 7 | 11 | 18 |
| More than one race | 0 | 0 | 0 |
| Unknown or Not Reported | 1 | 1 | 2 |
| Region of Enrollment(participants) | Cigarette Smokers | E-cigarette Users | Total |
|---|---|---|---|
| United States | 12 | 15 | 27 |
Documents are hosted by the registry — open the source record to download them.
Plan to share: No
This study is completed, as verified in Sep 2022. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Virginia Commonwealth University →