Endoscopic Ultrasound Guided Liver Biopsy

An interventional study of 22 gauge needle liver biopsy in Hepatic Cancer, Hepatic Neoplasm and Hepatic Carcinoma, sponsored by AdventHealth. Completed at 1 site in United States. Open to participants aged 19 Years and older. Per ClinicalTrials.gov, last updated 2019-02-11.

Sponsored by AdventHealth · Not applicable, Interventional, and Diagnostic

Phase
Not applicable
Study type
Interventional
Enrollment
40
Allocation
Not applicable
Ages
19 Years and older
Sex
All
01

Study summary

This is a prospective study to determine the optimal technique for obtaining liver tissue with a smaller caliber (22 gauge) needle and whether a good core biopsy can be obtained without the use of suction and secondly to determine the diagnostic yield and safety of 22 g Fine Needle Biopsy needle for liver biopsy.

Read the detailed description

Liver biopsy (LB) has historically been performed by percutaneous route without image guidance (blind biopsy). However, in the last several years there has been more reliance on image guidance ultrasound-guided (USG) or computed tomography (CT) to direct the needle into the liver with the hope of limiting complications. Other ways of performing liver biopsy are transjugular fluoroscopy guided approach when percutaneous route is deemed not safe because of coagulopathy or ascites. Surgical LB (either laparoscopic or open) is yet another way of obtaining liver tissue.

Endoscopic ultrasound guided liver biopsy (EUS-LB) is proposed as a newer method that may offer several potential advantages over existing techniques for attaining liver tissue. It can be performed in an outpatient setting and offers the comfort of sedation and analgesia. Endoscopic Ultrasound (EUS) provides high resolution images of left lobe of the liver and a good portion of the right lobe of the liver. This coupled with Doppler capability the biopsy needle can be safely directed into the liver for sampling under real time image guidance. Intervening structures such as pleura, bowel loops and gallbladder can be easily seen by EUS and thus avoided that further decreases the risk of adverse events. It has been recognized that sampling error can lead to diagnostic inaccuracy of a biopsy from a single site. As compared to USG or CT scan the EUS allows easy and safe biopsy of both left and right lobes of the liver during same setting, potentially addressing concerns about sampling error.

The cost of the endoscopic procedure is the main expense of EUS-LB. Thus this approach is best used for patients requiring EUS for evaluation of elevated liver tests. If no obstructive lesion is identified by EUS that will require endoscopic retrograde cholangiopancreatography (ERCP) then it would cost-effective to perform EUS-LB during the same setting without much additional time and risks. This approach can spare the patient the additional discomfort and expense of a second dedicated LB procedure by any of the other available techniques (percutaneous, transjugular etc.). In such setting the equipment costs for the EUS-LB will mainly include only the Fine Needle Biopsy (FNB) needle, which is similar in expense to the cost of needles for the transjugular or percutaneous approach.

The traditionally used transcutaneous LB needle is 16 gauge (G) while largest EUS biopsy needle is 19 G. The smaller size of the needle is expected to decrease the complications rate (mainly pain and bleeding) even further. Many studies using a 19 G Tru-cut biopsy or Fine Needle Aspiration (FNA) needle to acquire liver tissue have obtained specimens adequate for histologic diagnosis but there has been a wide range of specimen adequacy (19-100%). The 19 G Tru-cut biopsy needle has been associated with several technical difficulties that could reflect negatively on tissue adequacy.

While it is easy and straight forward to biopsy the left lobe of the liver with any EUS needle. The 19 G needle is a large bore needle for EUS use and it is sometimes difficult to attain an adequate position for biopsy specially in duodenum where scope is torqued and this is the only area of access to right lobe.

In this study the investigators will use a 22 G needle. Smaller caliber of the needle would not only make it technically easier to access right lobe of the liver through the duodenum, it is also expected to decrease the risks further due to smaller size. Also, the 22 G EUS-FNB needle has three cutting points at the cutting edge of the needle that provide stability at puncture while the high quality, fully formed heels are designed to maximize tissue capture and minimize fragmentation, that would result in attaining a good histological specimen, a main stay for liver biopsy.

02

Conditions studied

  • Hepatic Cancer
  • Hepatic Neoplasm
  • Hepatic Carcinoma

Keywords

  • liver
  • biopsy
  • hepatic
  • EUS
  • fine needle biopsy
03

In context

Liver Neoplasms

1,406 studies on the registry are indexed under Liver Neoplasms; 347 are open to participants now.

This study's enrollment of 40 is below the median of 47 across 975 interventional studies indexed under Liver Neoplasms.

Browse Liver Neoplasms studies →

Lead sponsor

AdventHealth is the lead sponsor of 113 studies on the registry; 23 are open to participants now.

Of its 5 completed or terminated interventional studies of FDA-regulated products, 2 (40%) have results posted.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
19 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  1. All patients referred to Florida Hospital Endoscopy Unit for assessment of elevated liver tests with EUS and are found to have no obstructive lesion to explain elevation of liver tests and will not require ERCP.
  2. Age ≥ 19 years
  3. Willing to provide informed consent verbal or written.

Exclusion criteria

Exclusion Criteria:

  1. Age \<19 years
  2. Unable to safely undergo EUS for any reason
  3. Coagulopathy (INR >1.6, Thrombocytopenia with platelet count \<50,000/ml) for subjects on anti-coagulation therapy.
  4. Unwilling or cognitively unable to provide informed consent verbal or written.
  5. Pregnancy (confirmed with Standard of Care urine pregnancy test for all women with child-bearing potential only)
05

Study design

Phase
Not applicable
Primary purpose
Diagnostic
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
40 participants (actual)

Study arms

  • Experimental
    22 gauge needle liver biopsy

    EUS-LB will be performed using a 22 g FNB needle. Specimens obtained from each pass will be placed in a separate biopsy jar. If the third pass does not result in sufficient diagnostic material, a 19 G will be used. A maximum of 3 passes will be made using the alternate needle. The total number of passes with the 22 G needle and the 19 G needle is 6. Data will be collected about the procedure and the performance of the needles for each procedure.

    Other: 22 gauge needle liver biopsy

Interventions

  • Other22 gauge needle liver biopsy

    EUS will be performed. Specimens obtained from each pass will be placed in a separate biopsy jar. If the third pass does not result in sufficient diagnostic material, a 19 G will be used. A maximum of 3 passes will be made using the alternate needle. The total number of passes with the 22 G needle and the 19 G needle is 6. Data will be collected about the procedure and the performance of the needles for each procedure.

06

What researchers measure

Primary outcomes

  1. Diagnostic adequacy of the liver biopsy specimen

    Determine the diagnostic adequacy of the liver biopsy specimen by obtaining a histological specimen using a smaller (22 G) caliber needle. Diagnostic adequacy is defined as a sample that provides definitive pathological diagnosis (yes, no).

    Time frame: Sample obtained during EUS-guided liver biopsy.

Secondary outcomes

  1. Visible core

    The sample will have a visible core (yes/no).

    Time frame: Sample obtained during EUS-guided liver biopsy.

  2. Suction

    Sample was obtained using suction (yes/no).

    Time frame: Sample obtained during EUS-guided liver biopsy.

  3. Number of passes required histological samples

    Assessing the median number of passes required to obtain diagnostically adequate histological samples histological samples

    Time frame: Time of Liver biopsy

  4. Technical failure

    Was there a technical failure (yes/no).

    Time frame: Time of Liver biopsy

  5. Complications/Bleeding

    Assessing subjects for post-procedural complications via follow up phone calls. Bleeding (yes/no).

    Time frame: 1 month

  6. Complications/Pain

    Assessing subjects for post-procedural complications via follow up phone calls. Pain (yes/no).

    Time frame: 1 month

  7. Complications/Infection

    Assessing subjects for post-procedural complications via follow up phone calls. Infection (yes/no).

    Time frame: 1 Month

07

Study locations

1 site
  • Center for Interventional Endoscopy - Florida Hospital
    Orlando, Florida 32803, United States
08

References and documents

Publications

  • Rockey DC, Caldwell SH, Goodman ZD, Nelson RC, Smith AD; American Association for the Study of Liver Diseases. Liver biopsy. Hepatology. 2009 Mar;49(3):1017-44. doi: 10.1002/hep.22742. No abstract available. PubMed 19243014 ↗
  • Kalambokis G, Manousou P, Vibhakorn S, Marelli L, Cholongitas E, Senzolo M, Patch D, Burroughs AK. Transjugular liver biopsy--indications, adequacy, quality of specimens, and complications--a systematic review. J Hepatol. 2007 Aug;47(2):284-94. doi: 10.1016/j.jhep.2007.05.001. Epub 2007 May 24. PubMed 17561303 ↗
  • Mathew A. EUS-guided routine liver biopsy in selected patients. Am J Gastroenterol. 2007 Oct;102(10):2354-5. doi: 10.1111/j.1572-0241.2007.01353_7.x. No abstract available. PubMed 17897349 ↗
  • Gleeson FC, Clayton AC, Zhang L, Clain JE, Gores GJ, Rajan E, Smyrk TC, Topazian MD, Wang KK, Wiersema MJ, Levy MJ. Adequacy of endoscopic ultrasound core needle biopsy specimen of nonmalignant hepatic parenchymal disease. Clin Gastroenterol Hepatol. 2008 Dec;6(12):1437-40. doi: 10.1016/j.cgh.2008.07.015. Epub 2008 Jul 26. PubMed 19081532 ↗
  • Dewitt J, McGreevy K, Cummings O, Sherman S, Leblanc JK, McHenry L, Al-Haddad M, Chalasani N. Initial experience with EUS-guided Tru-cut biopsy of benign liver disease. Gastrointest Endosc. 2009 Mar;69(3 Pt 1):535-42. doi: 10.1016/j.gie.2008.09.056. PubMed 19231495 ↗
  • Stavropoulos SN, Im GY, Jlayer Z, Harris MD, Pitea TC, Turi GK, Malet PF, Friedel DM, Grendell JH. High yield of same-session EUS-guided liver biopsy by 19-gauge FNA needle in patients undergoing EUS to exclude biliary obstruction. Gastrointest Endosc. 2012 Feb;75(2):310-8. doi: 10.1016/j.gie.2011.09.043. PubMed 22248599 ↗
  • Nakai Y, Samarasena JB, Iwashita T, Park DH, Lee JG, Hu KQ, Chang KJ. Autoimmune hepatitis diagnosed by endoscopic ultrasound-guided liver biopsy using a new 19-gauge histology needle. Endoscopy. 2012;44 Suppl 2 UCTN:E67-8. doi: 10.1055/s-0031-1291567. Epub 2012 Mar 6. No abstract available. PubMed 22396285 ↗
  • Maharaj B, Maharaj RJ, Leary WP, Cooppan RM, Naran AD, Pirie D, Pudifin DJ. Sampling variability and its influence on the diagnostic yield of percutaneous needle biopsy of the liver. Lancet. 1986 Mar 8;1(8480):523-5. doi: 10.1016/s0140-6736(86)90883-4. PubMed 2869260 ↗
  • Diehl DL, Johal AS, Khara HS, Stavropoulos SN, Al-Haddad M, Ramesh J, Varadarajulu S, Aslanian H, Gordon SR, Shieh FK, Pineda-Bonilla JJ, Dunkelberger T, Gondim DD, Chen EZ. Endoscopic ultrasound-guided liver biopsy: a multicenter experience. Endosc Int Open. 2015 Jun;3(3):E210-5. doi: 10.1055/s-0034-1391412. Epub 2015 Feb 27. PubMed 26171433 ↗

Individual participant data

Plan to share: No — There is no plan to share the individual participant data with other researchers.

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Feb 11, 2019, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT03307811
Lead sponsor
AdventHealth
Responsible party
Sponsor
First posted
Oct 12, 2017
Start date
Aug 1, 2017
Primary completion
Jun 19, 2018
Completion
Oct 1, 2018
Last update
Feb 11, 2019

Study contacts

Muhammad Hasan, MD
principal investigator · Florida Hospital - Center for Interventional Endoscopy

Oversight

Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Feb 2019. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion