ClinicalTrials.gg
Status unknownNCT03227588Updated Feb 12, 2019

Evaluation of the Opsens Fractional Flow Reserve (FFR) Wire as a "Work Horse" Wire

An observational study in Coronary Artery Disease, sponsored by Central Arkansas Veterans Healthcare System. Status unknown at 1 site in United States. Open to participants aged 18 Years to 89 Years. Per ClinicalTrials.gov, last updated 2019-02-12.

Sponsored by Central Arkansas Veterans Healthcare System · Observational

How we know

The sponsor has not verified this record recently (last verified Feb 2019), so the status shown — last known as Recruiting — may be out of date.

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Study type
Observational
Model
Case-only
Time perspective
Prospective
Enrollment
1,000
Ages
18 Years to 89 Years
Sex
All
01

Where this study stands

Counted across the records on this site · 2026-11-22

Among 1,104 studies in Coronary Artery Disease with a site in United States — 99 open to participants now, 144 under way, 10 of them phase 3. Coronary Artery Disease · United States.

Planned enrollment
70th of 357
1,000 · median 186
Started
2017
with 37 others
Observational
358 of 1,104
34 open now
Registered
790th of 1,104
by date

Among the 1,104 studies in Coronary Artery Disease with a site in United States, this one is the 70th largest by planned enrollment of the 357 observational ones that give a count, is one of 38 that started in 2017, is one of 358 observational ones, and was the 790th registered.

Coronary Artery Disease

4,866 studies on the registry are indexed under Coronary Artery Disease; 892 are open to participants now.

Browse Coronary Artery Disease studies →

Open to participants now

99 of the 1,104 studies in Coronary Artery Disease with a site in United States are open now. Recruiting first, the newest first:

94 more — sign in →

All 99 open studies →

A study can be open while its sites in United States have not opened yet or have stopped. Only those recruiting at a site in United States →

Who these studies take

Of the 591 Coronary Artery Disease studies recruiting now, 404 (68%) set no upper age limit and 68 (12%) stop at 75 or younger; 37 take children under 18; 49 take healthy volunteers.

This study: 18 Years to 89 Years · all sexes.

The full table on the hub →

This tab as a report to print or save as PDF → With an account.

Was this useful?
Get alerts for this landscapeDownload CSVNarrow it in search →With an account: a weekly mail of what changed among 1,104 studies in Coronary Artery Disease with a site in United States, or all of them as a file.
02

Study summary

The use of fractional flow reserve (FFR) has improved outcomes in percutaneous coronary interventions (PCI) in patients with symptomatic stable coronary artery disease (CAD) with intermediate angiographic stenoses. It is a clinical tool used routinely in cardiac catheterization laboratories throughout the world including the Little Rock VA Hospital. The technique utilizes a pressure transducer constructed as part of an 0.014" guidewire. An FFR of >0.80 has been linked with myocardial ischemia found with nuclear stress and dobutamine echo stress testing. The FAME trial clearly demonstrated its value in improving long-term outcomes as compared to use of angiography alone. As such, the use of FFR is incorporated into both AHA ACC and European PCI guideline recommendations as part of routine care for intermediate lesions. A "work horse" guide wire is so defined because it can be used in most PCI cases. It combines a low tip load (to avoid intimal dissection, with excellent (ideally, one to one) torque transmission and trackability through tortuous lesions. Recently the FDA has approved an FFR guide wire, OptoWire, (Opsens, Quebec City, Quebec, CAN) which uses light transmission to measure pressure rather than electrical transduction wires. The primary purpose of the present study is to determine how effective this wire is as a work horse wire in patients in whom FFR is required. The OptoWire may also have the advantage of less "drift" occurring during the procedure. Drift refers to the change in pressure due to issues related to the wire and measuring system, rather than a true change in pressure. All current FFR wire systems demonstrate some degree of drift requiring measuring pressure of the wire in the aorta after the procedure is completed to determine if, and to what extent, drift has occurred. Thus, a secondary aim of this study will determine the degree of drift.

Read the detailed description

EVALUATION OF THE OPSENS FRACTIONAL FLOW RESERVE (FFR) WIRE AS A "WORK HORSE" WIRE

INVESTIGATORS:

PRINCIPAL INVESTIGATOR: BARRY F URETSKY, MD CO-INVESTIGATOR: ABDUL HAKEEM, MD CO-INVESTIGATOR: MALEK AL-HAWWAS, MD

Introduction The use of fractional flow reserve (FFR) has improved outcomes in percutaneous coronary interventions (PCI) in patients with symptomatic stable coronary artery disease (CAD) with intermediate angiographic stenoses. It is a clinical tool used routinely in cardiac catheterization laboratories throughout the world including the Little Rock VA hospital. The technique utilizes a pressure transducer constructed as part of an 0.014" guidewire. The wire is passed distal to the stenosis. Under the condition of maximal hyperemia induced by a drug, typically adenosine, the pressure proximal to the stenosis, i.e. aortic pressure or Pa and the pressure distal to the stenosis, Pd, are measured. The ratio, Pd/Pa, under maximal flow or hyperemia is known as the fractional flow reserve (FFR). An FFR of \<0.80 has been correlated with observed myocardial ischemia using other diagnostic methods, particularly nuclear stress and dobutamine echo stress testing. The FAME trial clearly demonstrated its value in improving long-term outcomes as compared to use of angiography alone (1). As such, the use of FFR is incorporated into both AHA ACC and European PCI guideline recommendations as part of routine care for intermediate lesions (2,3).

One of the limitations of the use of the FFR pressure wire itself is that its handling characteristics are somewhat inferior to a standard "work horse" guide wire used for PCI. A "work horse" guide wire is so defined because it can be used in most PCI cases. It combines a low tip load (to avoid intimal dissection) with excellent (ideally, one-to-one) torque transmission and trackability through tortuous lesions. There are several different work horse wires available. Although the wires may be different for different Cath Labs and operators, the wires are universally used to maximize safety, efficacy, and efficiency of PCI.

In patients specifically requiring FFR to determine the value of PCI, it would be ideal if an FFR wire was as effective as a work horse wire so it could be used in difficult-to-traverse lesions. However, due to the complex electronics within current FFR wires, handling characteristics of previously used wires are inferior to current work horse wires. Recently the FDA has approved an FFR guide wire, OptoWire, (Opsens, Quebec City, Quebec, CAN) using light transmission to measure pressure rather than electrical transduction (4). It is commercially available in the United States. Its handling characteristics appear to approach that of a work horse guide wire and may represent an improvement over electrical transduction wires. The primary purpose of the present study is to determine how effective this wire is as a work horse wire in patients in whom FFR is required.

The OptoWire may also have the advantage of less "drift" occuring during the procedure. Drift refers to the change in pressure due to issues related to the wire and measuring system, rather than a true change in pressure. All current FFR wire systems demonstrate some degree of drift requiring measuring pressure of the wire in the aorta after the procedure is completed to determine if, and to what extent, drift has occurred. Thus, a secondary aim of this study will determine the degree of drift.

In clinical practice, FFR is performed before, and often after, PCI. In a study of 574 patients treated at the Little Rock VA (IRB Study, #779601), teh investigators found that approximately 20% of angiographically optimized PCI still had an ischemic FFR. The investigators further found that this ischemic value could be improved by further treatments including balloon angioplasty and stenting. Thus, the secondary purpose is to measure FFR after successful PCI to ascertain the incidence of persistently ischemic FFR after optimized angiographic stenting to confirm the result from out previous study.

Statistical analysis

This study is descriptive. It will use means and standard deviation for continuous variables and prevalence or incidence in percentages as appropriate to show results. As there is no comparator group, comparative statistics will not be employed.

Research aspect of study

The research aspect of the study is limited to the systematic collection and analysis of data using the Opsens FFR wire with plan for publication. The other aspects of the study are considered part of routine clinical care. They include passage of FFR wire, measurement of FFR pre- and post-PCI, and performance of PCI itself.

Significance of study

A wire that can be used as a workhorse as well as be able to measure FFR would be of great value. The more effective and efficient is the FFR wire in not only measuring pre-PCI FFR but being able to be used for PCI and be stable and durable enough to be used for post-PCI optimization, the greater is the probability that this approach will be more generally adopted into clinical practice. Demonstration that the Opsens FFR wire is effective in this regard should further this goal.

The investigators previously demonstrated that 21% or about 1 in 5 patients had an ischemic FFR after satisfactory angiographic result. This study will confirm previous results or suggest either an over- or under-estimation of that incidence.

03

Conditions studied

  • Coronary Artery Disease

Keywords

  • Fractional Flow Reserve
  • Percutaneous Coronary Intervention
04

Who can participate

Ages eligible
18 Years to 89 Years
Sexes eligible
All
Sampling method
Probability sample

Study population

Patients (age 18-89 years old) eligible and in whom the operator has performed FFR will be included to systematically evaluate the performance of the OptoWire FFR wire. A total of 1000 consecutive patients deemed to require FFR as part of clinical care will be included. It is felt that 1000 patients represent a reasonable sample size to study the OptoWire FFR wire handling characteristics, the primary endpoint of the study.

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

Patients (age 18-89 years old) eligible and in whom the operator has performed FFR will be included to systematically evaluate the performance of the OptoWire FFR wire. A total of 1000 consecutive patients deemed to require FFR as part of clinical care will be included. It is felt that 1000 patients represent a reasonable sample size to study the OptoWire FFR wire handling characteristics, the primary endpoint of the study

Exclusion criteria

Exclusion Criteria:

  1. Not a candidate for FFR
  2. Chronic total occlusion lesion
  3. Hemodynamically unstable
  4. Saphenous vein graft lesions -
05

Study design

Observational model
Case-only
Time perspective
Prospective
Enrollment
1,000 participants (estimated)
Target follow-up
1 Day
Patient registry
Yes

Interventions

  • Diagnostic testFractional Flow Reserve

    This is a prospective data collection study for patients that have undergone FFR.

06

What researchers measure

Primary outcomes

  1. Opsens FFR Wire Performance

    Satisfactory performance is defined as the ability to perform the entire PCI plus measure FFR pre and post PCI with drift \<0.05.

    Time frame: Acute result at end of procedure

Secondary outcomes

  1. Incidence of Ischemic or Low Non-ischemic FFR post PCI requiring further intervention

    Time frame: Acute result at end of procedure

07

Study locations

1 of 1 sites recruiting
  • John L. McClellan Memorial Veterans Hospital
    Little Rock, Arkansas 72205, United States
    Recruiting
    • Kristin Miller, RN · Contactkristin.miller4@va.gov · 501-257-5893
    • Barry F Uretsky, MD · Principal investigator
08

References and documents

Publications

  • Tonino PA, De Bruyne B, Pijls NH, Siebert U, Ikeno F, van' t Veer M, Klauss V, Manoharan G, Engstrom T, Oldroyd KG, Ver Lee PN, MacCarthy PA, Fearon WF; FAME Study Investigators. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention. N Engl J Med. 2009 Jan 15;360(3):213-24. doi: 10.1056/NEJMoa0807611. PubMed 19144937 ↗
  • Costa F, Ariotti S, Valgimigli M, Kolh P, Windecker S; Task Force on Myocardial Revascularization of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Perspectives on the 2014 ESC/EACTS Guidelines on Myocardial Revascularization : Fifty Years of Revascularization: Where Are We and Where Are We Heading? J Cardiovasc Transl Res. 2015 Jun;8(4):211-20. doi: 10.1007/s12265-015-9632-6. Epub 2015 May 19. PubMed 25986910 ↗
  • Levine GN, Bates ER, Blankenship JC, Bailey SR, Bittl JA, Cercek B, Chambers CE, Ellis SG, Guyton RA, Hollenberg SM, Khot UN, Lange RA, Mauri L, Mehran R, Moussa ID, Mukherjee D, Nallamothu BK, Ting HH; American College of Cardiology Foundation; American Heart Association Task Force on Practice Guidelines; Society for Cardiovascular Angiography and Interventions. 2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention. A report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Society for Cardiovascular Angiography and Interventions. J Am Coll Cardiol. 2011 Dec 6;58(24):e44-122. doi: 10.1016/j.jacc.2011.08.007. Epub 2011 Nov 7. No abstract available. PubMed 22070834 ↗
  • Agarwal SK, Kasula S, Hacioglu Y, Ahmed Z, Uretsky BF, Hakeem A. Utilizing Post-Intervention Fractional Flow Reserve to Optimize Acute Results and the Relationship to Long-Term Outcomes. JACC Cardiovasc Interv. 2016 May 23;9(10):1022-31. doi: 10.1016/j.jcin.2016.01.046. PubMed 27198682 ↗
  • Uretsky BF, Agarwal SK, Vallurupalli S, Al-Hawwas M, Hasan R, Miller K, Hakeem A. Prospective Evaluation of the Strategy of Functionally Optimized Coronary Intervention. J Am Heart Assoc. 2020 Feb 4;9(3):e015073. doi: 10.1161/JAHA.119.015073. Epub 2020 Jan 30. PubMed 32013707 ↗

Individual participant data

Plan to share: No

09

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Started Apr 2017 (actual). Primary completion is estimated for Dec 2019, 32 months after the start.

Of 637 non-industry observational studies under Coronary Artery Disease, half reached primary completion within 48 months of starting (the median), counting those still running; a quarter within 23 and three quarters within 122. This study's planned 32 months is below that.

Counting every sponsor, half of 762 studies reached it within 41 months; a quarter within 21 and three quarters within 87.

How these figures are worked out, and which studies are left out of them.

Registered
Jun 27, 2017
First posted
Jul 24, 2017
StartActual
Apr 10, 2017
Primary completionEst.
Dec 10, 2019
CompletionEst.
Dec 10, 2019
Last update
Feb 12, 2019
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Feb 12, 2019, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT03227588
Lead sponsor
Central Arkansas Veterans Healthcare System
Responsible party
Uretsky (Director of Interventional Cardiology and Cath Lab, Central Arkansas Veterans Healthcare System) — Principal investigator
First posted
Jul 24, 2017
Start date
Apr 10, 2017
Primary completion
Dec 10, 2019 (estimated)
Completion
Dec 10, 2019 (estimated)
Last update
Feb 12, 2019

Study contacts

Barry F. Uretsky, MD
Contact
barry.uretsky@va.gov
501-257-1000
Kristin G Miller, RN, CCRC
Contact
kristin.miller4@va.gov
501-257-5893
Barry F. Uretsky, MD
principal investigator · CAVHS

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is status unknown, as verified in Feb 2019. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion