ClinicalTrials.gg
CompletedNCT01838655Updated Feb 26, 2019Results posted

Nitisinone for Type 1B Oculocutaneous Albinism

A Phase 1/2 interventional study of Nitisinone in Albinism and Vision Loss, sponsored by National Eye Institute (NEI). Completed at 1 site in United States. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2019-02-26.

Sponsored by National Eye Institute (NEI) · Phase 1/2, Interventional, and Treatment

Phase
Phase 1/2
Study type
Interventional
Enrollment
5
Allocation
Not applicable
Ages
18 Years and older
Sex
All
01

Study summary

Background:

  • Oculocutaneous albinism, type 1B (OCA1B) is a genetic disease caused by problems in the gene that makes tyrosine. Tyrosine is an amino acid needed to produce pigment in the skin, hair, and eyes. People with OCA1B have pale skin, white hair, and light-colored eyes. Pigment in the back of the eye helps vision, so people with OCA-1B often have visual problems. Researchers want to see if a drug called nitisinone can help improve eye pigmentation and vision in people with OCA1B. Nitisinone is approved for treating a related genetic disease that causes problems with tyrosine, so it may help people with OCA1B.

Objectives:

  • To see if nitisinone can help improve eye pigmentation and vision in people with OCA1B.

Eligibility:

  • Individuals at least 18 years of age who have OCA1B.

Design:

  • This study will last about 18 months. It requires eight outpatient visits, each about 3 months apart. Each visit will require 1 to 2 days of testing.
  • Participants will be screened with a physical exam, eye exam, and medical history. They will have additional vision and neurological tests. They will be tested to see how their brain and retinas respond to light. They will also take hair and blood samples, and answer questions about diet.
  • Participants will receive the study drug. They will take one pill a day for 1 year. They will keep track of the dose in a study diary.
  • At the outpatient visits, participants will have the following tests:
  • Medical history and physical exam
  • Neurological and eye exams
  • Retina function tests
  • Tests of the skin and brain's response to light
  • Blood and urine tests
  • Dietary consultation
  • Visual function questionnaire.
  • After the end of the study, participants will return to the care of their regular eye doctor.
Read the detailed description

Objective: The primary objective of this study is to evaluate oral nitisinone as a treatment that improves ocular pigmentation in adult participants with oculocutaneous albinism, type 1B (OCA1B). Secondary objectives of this study are to determine whether the selected outcome measures are robust enough to use in a larger trial and to assess whether oral nitisinone improves visual function, skin pigmentation, and hair pigmentation in participants with OCA1B.

Study Population: Five participants with OCA1B will be enrolled initially. However, up to an additional three participants may be enrolled to account for participants who withdraw from the study for any reason before the Month 12 visit.

Design: In this pilot, phase 1/2, single-site, prospective, open label trial, participants will receive 2 mg of oral nitisinone daily for at least one year, and they will be followed for at least 18 months. Ocular and non-ocular data will be collected at least every three months, with the first follow-up visit occurring three months after the final baseline visit. Participants will be required to have at least 8 outpatient visits at the NEI clinic over a period of 18 months. This study has a common termination date and therefore may continue for up to four years.

Outcome Measures: The primary outcome for the study is the absolute mean change in iris pigmentation on an 8-point scale at 12 months as compared to baseline. Participants left and right eyes will be analyzed. The absolute mean change in iris pigmentation for each eye on an 8-point scale at 3, 6 and 9 months compared to baseline will be assessed as secondary outcomes. Other secondary outcomes include the absolute and percent change in semi-quantitative iris pigmentation on image analysis; the absolute change in electronic visual acuity (EVA) for each eye and binocular vision; the absolute change in contrast sensitivity without glare, with medium glare, and with high glare for binocular vision; the absolute change in full-field ERG measures for each eye; and the absolute and percent change in melanin content in skin using skin reflectometry at 3, 6, 9 and 12 months as compared to baseline; Qualitative changes in hair, skin, and fundus pigmentation at 3, 6, 9 and 12 months as compared to previous visit will be assessed. The absolute and percent change in hair melanin will also be assessed at 12 months as compared to baseline. The number and severity of adverse events and the number of withdrawals will be assessed as safety outcomes.

02

Conditions studied

  • Albinism
  • Vision Loss

Keywords

  • Albinism
  • Nitisinone
  • Melanin
  • Vision Loss
03

In context

Albinism

17 studies on the registry are indexed under Albinism; 8 are open to participants now.

Browse Albinism studies →

Lead sponsor

National Eye Institute (NEI) is the lead sponsor of 272 studies on the registry; 17 are open to participants now.

Of its 8 completed or terminated interventional studies of FDA-regulated products, 8 (100%) have results posted.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

To be eligible, the following inclusion criteria must be met, when applicable.

  1. Participant must be 18 years of age or older.
  2. Participant must understand and sign the protocol s document.
  3. Participant must have normal renal function, liver function, and counts or have mild abnormalities no greater than grade 1 as defined by the v4.0 (CTCAE).
  4. Any female participant of must have a negative pregnancy test at screening and must be willing to undergo pregnancy testing immediately prior to the start of the product and while on the investigational product.
  5. Any female participant of childbearing potential and any male participant able to father children must have (or have a partner who has) had a hysterectomy or vasectomy, be completely abstinent from intercourse, or must agree to practice two effective methods of while taking the investigational product and for at least two months following the last dose of investigational product. Acceptable methods of contraception include:

    • Hormonal contraception (i.e., birth control pills, injected hormones, dermal patch, or vaginal ring),
    • Intrauterine device,
    • Barrier methods (diaphragm, condom) with spermicide, or
    • Surgical sterilization (tubal ligation).
  6. Participant must have OCA1B, as defined by ALL (a-d) of the following criteria:

    1. Participant has ophthalmic signs or symptoms of albinism, including:

      • Bilateral visual acuity E-ETDRS EVA letter score of less than or equal to 83 (i.e., Snellen equivalent of 20/25 or worse) that is not attributable to any other pathology.
      • Bilateral iris transillumination that can be seen in clinical photographs.
    2. Predominant contralateral decussation of ganglion cell axons, as determined by pattern visual evoked potential (VEP).
    3. Participant has at least one definitive mutation in the OCA1 gene (tyrosinase).
    4. Participant has no definitive mutations in the OCA2 gene.

Exclusion criteria

EXCLUSION CRITERIA:

  • Participant is pregnant or breast-feeding.
  • Participant is a male AND has a definitive mutation in the OA1 gene.
  • Participant has any of the following abnormal laboratory test results:

    1. Serum potassium \< 3.0 mEq/L,
    2. Serum CK > 500 U/L,
    3. \< 10.0 g/dL,
    4. White blood cell (WBC) count \< 3.0 k/microL,
    5. Plasma tyrosine > 150 microM,
    6. ESR > 100 mm/h, and/or
    7. Serum T4 > 15 microg/dL OR Serum T4 \< 4 microg/dL.
  • Participant has keratopathy.
  • Participant has a current .
  • Participant has open skin lesions.
  • Participant is on a diet that deliberately increases protein intake to disproportionate levels (e.g., Atkins diet). The diet must be reasonably balanced, as determined by a dietician.
  • Participant has uncontrolled hypertension, defined as systolic blood pressure above 180 mmHg or diastolic blood pressure above 95 mmHg.
  • Participant has another chronic ocular disease that may confound the results of visual tests, such as age-related macular degeneration, cataract of possible visual significance, or uncontrolled glaucoma.
  • Participant drinks more than the equivalent of two glasses of wine per day on average, has a history of alcohol abuse, or has a severe liver illness.
  • Participant s liver is > 3 cm below the right costal margin.
  • Participant has a muscle disease.
  • Participant is currently taking a medication known to cause elevated liver function tests including statins/HMG-Co-A reductase inhibitors (e.g., lovastatin, simvastatin); anti-epileptic medications (e.g., carbamazepine, phenytoin, phenobarbital); tetracycline or its derivatives, if used chronically; acetaminophen, if used daily/chronically; amiodarone; and any other medications with known significant liver toxicity.
Terms in these criteria, in plain language(8)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

Platelets

Blood cells that help blood clot. Too few raises the risk of bleeding and bruising. A usual adult range is about 150–400 × 10⁹/L (150,000–400,000 per µL); each lab has its own reference range.

CTCAE grade

The US National Cancer Institute’s scale of how severe an adverse event is — any unwanted medical event during a study, such as a symptom, an illness or an abnormal test result, whether or not a treatment caused it. Whether it did is judged separately.

1
Mild.
2
Moderate.
3
Severe.
4
Life-threatening.
5
Death due to the event.

“Side effects of earlier treatment resolved to grade 1 or less” means they have settled to mild or gone.

Childbearing potential

Able to become pregnant: from the first period until menopause, unless permanently unable to through surgery (removal of the womb, or of both ovaries or both fallopian tubes).

Criteria for people of childbearing potential usually ask for a negative pregnancy test and for contraception during the study and for a time after it.

Investigational drug or device

A drug or device being studied in a clinical trial.

It may be new, or already approved and being studied for another use, dose or form. Criteria often leave out people who took part in another study of one within a recent period, commonly 30 days or five half-lives.

Contraception

Ways of preventing pregnancy. “Highly effective” methods fail less than 1% of the time a year when used correctly — for example an IUD or an implant.

Criteria usually say which methods count and how long to keep using them after the last dose, sometimes for male participants too. Some studies accept a partner’s vasectomy if it was confirmed successful and that person is the participant’s only sexual partner.

Hemoglobin (Hb)

The protein in red blood cells that carries oxygen. A low level is anaemia, which can cause tiredness and breathlessness. Measured in g/dL or g/L (9 g/dL is 90 g/L).

Cancer (malignancy)

Malignancy means cancer. Criteria about another or earlier malignancy ask whether you have had a different cancer, usually within a set number of years.

Some are commonly allowed, such as treated skin cancers other than melanoma and early cancers removed completely — check the exceptions this study lists.

05

Study design

Phase
Phase 1 / Phase 2
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
5 participants (actual)

Study arms

  • Experimental
    Nitisinone

    Oral administration of nitisinone

    Drug: Nitisinone

Interventions

  • Oral dose of 2mg daily for 12 months.

    Also known as: Orfadin

06

What researchers measure

Primary outcomes

  1. Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 12 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.

    High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 12 months was calculated; these mean grades were then used to calculate absolute change from baseline at 12 months.

    Time frame: Baseline and 12 months

Secondary outcomes

  1. Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 3 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.

    High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 3 months was calculated; these mean grades were then used to calculate absolute change from baseline at 3 months.

    Time frame: Baseline and 3 months

  2. Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 6 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.

    High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 6 months was calculated; these mean grades were then used to calculate absolute change from baseline at 6 months.

    Time frame: Baseline and 6 months

  3. Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 9 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.

    High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 9 months was calculated; these mean grades were then used to calculate absolute change from baseline at 9 months.

    Time frame: Baseline and 9 months

  4. Absolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 3 Months as Compared to Baseline

    In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 3 months; these mean grades were then used to calculate absolute change from baseline.

    Time frame: Baseline and 3 months

  5. Absolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 6 Months as Compared to Baseline

    In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 6 months; these mean grades were then used to calculate absolute change from baseline.

    Time frame: Baseline and 6 months

  6. Absolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 9 Months as Compared to Baseline

    In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 9 months; these mean grades were then used to calculate absolute change from baseline.

    Time frame: Baseline and 9 months

  7. Absolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 12 Months as Compared to Baseline

    In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 12 months; these mean grades were then used to calculate absolute change from baseline.

    Time frame: Baseline and 12 months

  8. Percent Change in Semi-quantitative Iris Pigmentation for Each Eye at 3 Months as Compared to Baseline

    In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 3 months; these mean grades were then used to calculate percentage change from baseline.

    Time frame: Baseline and 3 months

  9. Percent Change in Semi-quantitative Iris Pigmentation for Each Eye at 6 Months as Compared to Baseline

    In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 6 months; these mean grades were then used to calculate percentage change from baseline.

    Time frame: Baseline and 6 months

  10. Percent Change in Semi-quantitative Iris Pigmentation for Each Eye at 9 Months as Compared to Baseline

    In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 9 months; these mean grades were then used to calculate percentage change from baseline.

    Time frame: Baseline and 9 months

  11. Percent Change in Semi-quantitative Iris Pigmentation for Each Eye at 12 Months as Compared to Baseline

    In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 12 months; these mean grades were then used to calculate percentage change from baseline.

    Time frame: Baseline and 12 months

  12. Absolute Change in Electronic Visual Acuity at 3 Months Compared to Baseline

    Visual acuity was measured using the Electronic ETDRS Visual Acuity Testing protocol. Acuity is measured as letters read using an electronic ETDRS program.

    Time frame: Baseline and 3 months

  13. Absolute Change in Electronic Visual Acuity at 6 Months Compared to Baseline

    Visual acuity was measured using the Electronic ETDRS Visual Acuity Testing protocol. Acuity is measured as letters read using an electronic ETDRS program.

    Time frame: Baseline and 6 months

  14. Absolute Change in Electronic Visual Acuity at 9 Months Compared to Baseline

    Visual acuity was measured using the Electronic ETDRS Visual Acuity Testing protocol. Acuity is measured as letters read using an electronic ETDRS program.

    Time frame: Baseline and 9 months

  15. Absolute Change in Electronic Visual Acuity at 12 Months Compared to Baseline

    Visual acuity was measured using the Electronic ETDRS Visual Acuity Testing protocol. Acuity is measured as letters read using an electronic ETDRS program.

    Time frame: Baseline and 12 months

  16. Absolute Change in Contrast Sensitivity Without Glare at 3 Months Compared to Baseline

    Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. The minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity without glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 3 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

    Time frame: Baseline and 3 months

  17. Absolute Change in Contrast Sensitivity Without Glare at 6 Months Compared to Baseline

    Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. The minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity without glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 6 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

    Time frame: Baseline and 6 months

  18. Absolute Change in Contrast Sensitivity Without Glare at 9 Months Compared to Baseline

    Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. The minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity without glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 9 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

    Time frame: Baseline and 9 months

  19. Absolute Change in Contrast Sensitivity Without Glare at 12 Months Compared to Baseline

    Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. The minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity without glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 12 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

    Time frame: Baseline and 12 months

  20. Absolute Change in Contrast Sensitivity With Medium Glare at 3 Months Compared to Baseline

    Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with medium glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 3 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

    Time frame: Baseline and 3 months

  21. Absolute Change in Contrast Sensitivity With Medium Glare at 6 Months Compared to Baseline

    Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with medium glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 6 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

    Time frame: Baseline and 6 months

  22. Absolute Change in Contrast Sensitivity With Medium Glare at 9 Months Compared to Baseline

    Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with medium glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 9 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

    Time frame: Baseline and 9 months

  23. Absolute Change in Contrast Sensitivity With Medium Glare at 12 Months Compared to Baseline

    Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with medium glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 12 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

    Time frame: Baseline and 12 months

  24. Absolute Change in Contrast Sensitivity With High Glare at 3 Months Compared to Baseline

    Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with high glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 3 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

    Time frame: Baseline and 3 months

  25. Absolute Change in Contrast Sensitivity With High Glare at 6 Months Compared to Baseline

    Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with high glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 6 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

    Time frame: Baseline and 6 months

  26. Absolute Change in Contrast Sensitivity With High Glare at 9 Months Compared to Baseline

    Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with high glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 9 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

    Time frame: Baseline and 9 months

  27. Absolute Change in Contrast Sensitivity With High Glare at 12 Months Compared to Baseline

    Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with high glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 12 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

    Time frame: Baseline and 12 months

  28. Absolute Change in Adjusted Melanin Index at 3 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

    Time frame: Baseline and 3 Months

  29. Absolute Change in Adjusted Melanin Index at 6 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

    Time frame: Baseline and 6 Months

  30. Absolute Change in Adjusted Melanin Index at 9 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

    Time frame: Baseline and 9 Months

  31. Absolute Change in Adjusted Melanin Index at 12 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

    Time frame: Baseline and 12 Months

  32. Percent Change in Adjusted Melanin Index at 3 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

    Time frame: Baseline and 3 Months

  33. Percent Change in Adjusted Melanin Index at 6 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

    Time frame: Baseline and 6 Months

  34. Percent Change in Adjusted Melanin Index at 9 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

    Time frame: Baseline and 9 Months

  35. Percent Change in Adjusted Melanin Index at 12 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

    Time frame: Baseline and 12 Months

  36. Absolute Change in Melanin Index at 3 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

    Time frame: Baseline and 3 Months

  37. Absolute Change in Melanin Index at 6 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

    Time frame: Baseline and 6 Months

  38. Absolute Change in Melanin Index at 9 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

    Time frame: Baseline and 9 Months

  39. Absolute Change in Melanin Index at 12 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

    Time frame: Baseline and 12 Months

  40. Percent Change in Melanin Index at 3 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

    Time frame: Baseline and 3 Months

  41. Percent Change in Melanin Index at 6 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

    Time frame: Baseline and 6 Months

  42. Percent Change in Melanin Index at 9 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

    Time frame: Baseline and 9 Months

  43. Percent Change in Melanin Index at 12 Months Compared to Baseline

    Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

    Time frame: Baseline and 12 Months

  44. Absolute Change in Electroretinogram (ERG) at Month 6 as Compared to Baseline.

    Amplitude for the ERG parameter, Dark Adaptation (DA) Comb B, was measured at each visit. Participants left and right eye will be analyzed.

    Time frame: Baseline and 6 months

  45. Absolute Change in Electroretinogram (ERG) at Month 12 as Compared to Baseline.

    Amplitude for the ERG parameter, Dark Adaptation (DA) Comb B, was measured at each visit. Participants left and right eye will be analyzed.

    Time frame: Baseline and 12 months

  46. Qualitative Change in Hair Pigmentation at 3 Months Compared to Previous Visit.

    Qualitative change in hair pigmentation was measured as a binary endpoint (no change vs. increase) at Month 3 compared to previous visit.

    Time frame: Baseline and 3 months

  47. Qualitative Change in Hair Pigmentation at 6 Months Compared to Previous Visit.

    Qualitative change in hair pigmentation was measured as a binary endpoint (no change vs. increase) at Month 6 compared to Month 3

    Time frame: 3 Months and 6 months

  48. Qualitative Change in Hair Pigmentation at 9 Months Compared to Previous Visit.

    Qualitative change in hair pigmentation was measured as a binary endpoint (no change vs. increase) at Month 9 compared to Month 6

    Time frame: 6 Months and 9 months

  49. Qualitative Change in Hair Pigmentation at 12 Months Compared to Previous Visit.

    Qualitative change in hair pigmentation was measured as a binary endpoint (no change vs. increase) at Month 12 compared to Month 9

    Time frame: 9 Months and 12 months

  50. Qualitative Change in Skin Pigmentation at 3 Months Compared to Previous Visit.

    Qualitative change in skin pigmentation was measured as a binary endpoint (no change vs. increase) at Month 3 compared to previous visit.

    Time frame: Baseline and 3 months

  51. Qualitative Change in Skin Pigmentation at 6 Months Compared to Previous Visit.

    Qualitative change in skin pigmentation was measured as a binary endpoint (no change vs. increase) at Month 6 compared to Month 3

    Time frame: 3 Months and 6 months

  52. Qualitative Change in Skin Pigmentation at 9 Months Compared to Previous Visit.

    Qualitative change in skin pigmentation was measured as a binary endpoint (no change vs. increase) at Month 9 compared to Month 6

    Time frame: 6 Months and 9 months

  53. Qualitative Change in Skin Pigmentation at 12 Months Compared to Previous Visit.

    Qualitative change in skin pigmentation was measured as a binary endpoint (no change vs. increase) at Month 12 compared to Month 9

    Time frame: 9 Months and 12 months

  54. Qualitative Change in Fundus Pigmentation at 3 Months Compared to Previous Visit.

    Qualitative change in fundus pigmentation was measured as a binary endpoint (no change vs. increase) at Month 3 compared to previous visit.

    Time frame: Baseline and 3 months

  55. Qualitative Change in Fundus Pigmentation at 6 Months Compared to Previous Visit.

    Qualitative change in fundus pigmentation was measured as a binary endpoint (no change vs. increase) at Month 6 compared to Month 3

    Time frame: 3 Months and 6 months

  56. Qualitative Change in Fundus Pigmentation at 9 Months Compared to Previous Visit.

    Qualitative change in fundus pigmentation was measured as a binary endpoint (no change vs. increase) at Month 9 compared to Month 6

    Time frame: 6 Months and 9 months

  57. Qualitative Change in Fundus Pigmentation at 12 Months Compared to Previous Visit.

    Qualitative change in fundus pigmentation was measured as a binary endpoint (no change vs. increase) at Month 12 compared to Month 9

    Time frame: 9 Months and 12 months

  58. Absolute Change in Hair Melanin at 12 Months Compared to Baseline

    Hair melanin was assessed using pyrrole-2,3,5-tricarboxylic acid (PTCA), a marker of eumelanin and 4-amino-3-hydroxyphenylalanine (4-AHP), a marker of pheomelanin.

    Time frame: Baseline and 12 months

  59. Percent Change in Hair Melanin at 12 Months Compared to Baseline

    Hair melanin was assessed using pyrrole-2,3,5-tricarboxylic acid (PTCA), a marker of eumelanin and 4-amino-3-hydroxyphenylalanine (4-AHP), a marker of pheomelanin.

    Time frame: Baseline and 12 months

Other outcomes

  1. Number of Ocular Adverse Events

    Time frame: Study duration, up to 18 months

  2. Number of Non-ocular Adverse Events

    Time frame: Study duration, up to 18 months

  3. Severity of Adverse Events

    Time frame: Study duration, up to 18 months

  4. Number of Adverse Events Related to Investigational Product (IP)

    Time frame: Study duration, up to 18 months

  5. Number of Participants Withdrawn From Investigational Product (IP) Due to Safety and Abnormal Laboratory Results

    Time frame: Study duration, up to 18 months

07

Results

Posted Nov 17, 2017

Participant flow

Five participants with OCA1B will be enrolled initially. However, up to an additional three participants may be enrolled to account for participants who withdraw from the study for any reason before the Month 12 visit.

Participant flow — Overall Study
MilestoneNitisinone
Started5
Completed5
Not completed0

Outcome measures

PrimaryAbsolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 12 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.

High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 12 months was calculated; these mean grades were then used to calculate absolute change from baseline at 12 months.

Time frame:
Baseline and 12 months
Reported as:
Mean · scores on a scale
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 12 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.
scores on a scaleNitisinone
OD1.2 ± 1.68
OS0.9 ± 1.52
SecondaryAbsolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 3 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.

High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 3 months was calculated; these mean grades were then used to calculate absolute change from baseline at 3 months.

Time frame:
Baseline and 3 months
Reported as:
Mean · scores on a scale
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 3 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.
scores on a scaleNitisinone
OD0.8 ± 1.04
OS0.9 ± 1.23
SecondaryAbsolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 6 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.

High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 6 months was calculated; these mean grades were then used to calculate absolute change from baseline at 6 months.

Time frame:
Baseline and 6 months
Reported as:
Mean · scores on a scale
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 6 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.
scores on a scaleNitisinone
OD0.6 ± 0.39
OS0.4 ± 0.31
SecondaryAbsolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 9 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.

High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 9 months was calculated; these mean grades were then used to calculate absolute change from baseline at 9 months.

Time frame:
Baseline and 9 months
Reported as:
Mean · scores on a scale
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 9 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.
scores on a scaleNitisinone
OD0.9 ± 1.06
OS0.6 ± 0.60
SecondaryAbsolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 3 Months as Compared to Baseline

In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 3 months; these mean grades were then used to calculate absolute change from baseline.

Time frame:
Baseline and 3 months
Reported as:
Mean · scores on a scale
Absolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 3 Months as Compared to Baseline
scores on a scaleNitisinone
OD1.2 ± 1.04
OS0.6 ± 0.82
SecondaryAbsolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 6 Months as Compared to Baseline

In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 6 months; these mean grades were then used to calculate absolute change from baseline.

Time frame:
Baseline and 6 months
Reported as:
Mean · scores on a scale
Absolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 6 Months as Compared to Baseline
scores on a scaleNitisinone
OD0.4 ± 0.55
OS0.1 ± 0.22
SecondaryAbsolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 9 Months as Compared to Baseline

In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 9 months; these mean grades were then used to calculate absolute change from baseline.

Time frame:
Baseline and 9 months
Reported as:
Mean · scores on a scale
Absolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 9 Months as Compared to Baseline
scores on a scaleNitisinone
OD0.8 ± 0.76
OS0.7 ± 0.84
SecondaryAbsolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 12 Months as Compared to Baseline

In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 12 months; these mean grades were then used to calculate absolute change from baseline.

Time frame:
Baseline and 12 months
Reported as:
Mean · scores on a scale
Absolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 12 Months as Compared to Baseline
scores on a scaleNitisinone
OD1.4 ± 1.39
OS1.2 ± 1.15
SecondaryPercent Change in Semi-quantitative Iris Pigmentation for Each Eye at 3 Months as Compared to Baseline

In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 3 months; these mean grades were then used to calculate percentage change from baseline.

Time frame:
Baseline and 3 months
Reported as:
Mean · percentage change
Percent Change in Semi-quantitative Iris Pigmentation for Each Eye at 3 Months as Compared to Baseline
percentage changeNitisinone
OD66.7 ± 51.37
OS29.0 ± 41.29
SecondaryPercent Change in Semi-quantitative Iris Pigmentation for Each Eye at 6 Months as Compared to Baseline

In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 6 months; these mean grades were then used to calculate percentage change from baseline.

Time frame:
Baseline and 6 months
Reported as:
Mean · percentage change
Percent Change in Semi-quantitative Iris Pigmentation for Each Eye at 6 Months as Compared to Baseline
percentage changeNitisinone
OD23.3 ± 32.49
OS4.0 ± 8.94
SecondaryPercent Change in Semi-quantitative Iris Pigmentation for Each Eye at 9 Months as Compared to Baseline

In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 9 months; these mean grades were then used to calculate percentage change from baseline.

Time frame:
Baseline and 9 months
Reported as:
Mean · percentage change
Percent Change in Semi-quantitative Iris Pigmentation for Each Eye at 9 Months as Compared to Baseline
percentage changeNitisinone
OD42.0 ± 42.66
OS34.0 ± 42.19
SecondaryPercent Change in Semi-quantitative Iris Pigmentation for Each Eye at 12 Months as Compared to Baseline

In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 12 months; these mean grades were then used to calculate percentage change from baseline.

Time frame:
Baseline and 12 months
Reported as:
Mean · percentage change
Percent Change in Semi-quantitative Iris Pigmentation for Each Eye at 12 Months as Compared to Baseline
percentage changeNitisinone
OD77.7 ± 91.94
OS67.0 ± 59.75
SecondaryAbsolute Change in Electronic Visual Acuity at 3 Months Compared to Baseline

Visual acuity was measured using the Electronic ETDRS Visual Acuity Testing protocol. Acuity is measured as letters read using an electronic ETDRS program.

Time frame:
Baseline and 3 months
Reported as:
Mean · ETDRS letters
Absolute Change in Electronic Visual Acuity at 3 Months Compared to Baseline
ETDRS lettersNitisinone
OD1.8 ± 0.84
OS6.0 ± 3.61
SecondaryAbsolute Change in Electronic Visual Acuity at 6 Months Compared to Baseline

Visual acuity was measured using the Electronic ETDRS Visual Acuity Testing protocol. Acuity is measured as letters read using an electronic ETDRS program.

Time frame:
Baseline and 6 months
Reported as:
Mean · ETDRS letters
Absolute Change in Electronic Visual Acuity at 6 Months Compared to Baseline
ETDRS lettersNitisinone
OD4.2 ± 2.17
OS4.8 ± 3.42
SecondaryAbsolute Change in Electronic Visual Acuity at 9 Months Compared to Baseline

Visual acuity was measured using the Electronic ETDRS Visual Acuity Testing protocol. Acuity is measured as letters read using an electronic ETDRS program.

Time frame:
Baseline and 9 months
Reported as:
Mean · ETDRS letters
Absolute Change in Electronic Visual Acuity at 9 Months Compared to Baseline
ETDRS lettersNitisinone
OD2.8 ± 2.95
OS5.6 ± 2.51
SecondaryAbsolute Change in Electronic Visual Acuity at 12 Months Compared to Baseline

Visual acuity was measured using the Electronic ETDRS Visual Acuity Testing protocol. Acuity is measured as letters read using an electronic ETDRS program.

Time frame:
Baseline and 12 months
Reported as:
Mean · ETDRS letters
Absolute Change in Electronic Visual Acuity at 12 Months Compared to Baseline
ETDRS lettersNitisinone
OD5.4 ± 3.78
OS5.0 ± 5.70
SecondaryAbsolute Change in Contrast Sensitivity Without Glare at 3 Months Compared to Baseline

Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. The minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity without glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 3 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

Time frame:
Baseline and 3 months
Reported as:
Mean · units
Absolute Change in Contrast Sensitivity Without Glare at 3 Months Compared to Baseline
unitsNitisinone
Frequency 1.51.6 ± 1.52
Frequency 30.8 ± 0.84
Frequency 60.4 ± 0.55
Frequency 121.2 ± 2.17
Frequency 180.6 ± 1.34
SecondaryAbsolute Change in Contrast Sensitivity Without Glare at 6 Months Compared to Baseline

Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. The minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity without glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 6 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

Time frame:
Baseline and 6 months
Reported as:
Mean · units
Absolute Change in Contrast Sensitivity Without Glare at 6 Months Compared to Baseline
unitsNitisinone
Frequency 1.52.0 ± 2.83
Frequency 30.2 ± 0.45
Frequency 61.6 ± 1.52
Frequency 122.8 ± 2.95
Frequency 180.0 ± 0.00
SecondaryAbsolute Change in Contrast Sensitivity Without Glare at 9 Months Compared to Baseline

Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. The minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity without glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 9 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

Time frame:
Baseline and 9 months
Reported as:
Mean · units
Absolute Change in Contrast Sensitivity Without Glare at 9 Months Compared to Baseline
unitsNitisinone
Frequency 1.51.8 ± 2.49
Frequency 30.6 ± 0.55
Frequency 61.0 ± 1.00
Frequency 121.4 ± 2.19
Frequency 180.0 ± 0.00
SecondaryAbsolute Change in Contrast Sensitivity Without Glare at 12 Months Compared to Baseline

Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. The minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity without glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 12 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

Time frame:
Baseline and 12 months
Reported as:
Mean · units
Absolute Change in Contrast Sensitivity Without Glare at 12 Months Compared to Baseline
unitsNitisinone
Frequency 1.52.4 ± 2.51
Frequency 32.0 ± 2.55
Frequency 61.8 ± 1.92
Frequency 121.6 ± 2.19
Frequency 180.6 ± 1.34
SecondaryAbsolute Change in Contrast Sensitivity With Medium Glare at 3 Months Compared to Baseline

Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with medium glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 3 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

Time frame:
Baseline and 3 months
Reported as:
Mean · units
Absolute Change in Contrast Sensitivity With Medium Glare at 3 Months Compared to Baseline
unitsNitisinone
Frequency 1.51.4 ± 1.14
Frequency 30.4 ± 0.55
Frequency 63.6 ± 3.78
Frequency 120.2 ± 0.45
Frequency 180.6 ± 1.34
SecondaryAbsolute Change in Contrast Sensitivity With Medium Glare at 6 Months Compared to Baseline

Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with medium glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 6 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

Time frame:
Baseline and 6 months
Reported as:
Mean · units
Absolute Change in Contrast Sensitivity With Medium Glare at 6 Months Compared to Baseline
unitsNitisinone
Frequency 1.52.4 ± 2.88
Frequency 31.4 ± 1.67
Frequency 61.8 ± 1.79
Frequency 120.4 ± 0.89
Frequency 180.6 ± 1.34
SecondaryAbsolute Change in Contrast Sensitivity With Medium Glare at 9 Months Compared to Baseline

Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with medium glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 9 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

Time frame:
Baseline and 9 months
Reported as:
Mean · units
Absolute Change in Contrast Sensitivity With Medium Glare at 9 Months Compared to Baseline
unitsNitisinone
Frequency 1.52.0 ± 2.35
Frequency 31.2 ± 0.84
Frequency 61.0 ± 1.00
Frequency 120.6 ± 1.34
Frequency 180.8 ± 1.30
SecondaryAbsolute Change in Contrast Sensitivity With Medium Glare at 12 Months Compared to Baseline

Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with medium glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 12 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

Time frame:
Baseline and 12 months
Reported as:
Mean · units
Absolute Change in Contrast Sensitivity With Medium Glare at 12 Months Compared to Baseline
unitsNitisinone
Frequency 1.51.4 ± 2.61
Frequency 31.8 ± 1.79
Frequency 62.6 ± 2.79
Frequency 120.4 ± 0.89
Frequency 181.2 ± 1.64
SecondaryAbsolute Change in Contrast Sensitivity With High Glare at 3 Months Compared to Baseline

Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with high glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 3 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

Time frame:
Baseline and 3 months
Reported as:
Mean · units
Absolute Change in Contrast Sensitivity With High Glare at 3 Months Compared to Baseline
unitsNitisinone
Frequency 1.51.2 ± 1.10
Frequency 31.8 ± 2.49
Frequency 60.2 ± 0.45
Frequency 120.2 ± 0.45
Frequency 180.0 ± 0.00
SecondaryAbsolute Change in Contrast Sensitivity With High Glare at 6 Months Compared to Baseline

Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with high glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 6 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

Time frame:
Baseline and 6 months
Reported as:
Mean · units
Absolute Change in Contrast Sensitivity With High Glare at 6 Months Compared to Baseline
unitsNitisinone
Frequency 1.51.0 ± 1.00
Frequency 31.6 ± 1.67
Frequency 61.2 ± 2.17
Frequency 120.4 ± 0.55
Frequency 180.0 ± 0.00
SecondaryAbsolute Change in Contrast Sensitivity With High Glare at 9 Months Compared to Baseline

Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with high glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 9 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

Time frame:
Baseline and 9 months
Reported as:
Mean · units
Absolute Change in Contrast Sensitivity With High Glare at 9 Months Compared to Baseline
unitsNitisinone
Frequency 1.51.4 ± 0.55
Frequency 30.6 ± 0.55
Frequency 61.0 ± 2.24
Frequency 121.6 ± 2.61
Frequency 180.6 ± 1.34
SecondaryAbsolute Change in Contrast Sensitivity With High Glare at 12 Months Compared to Baseline

Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with high glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 12 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.

Time frame:
Baseline and 12 months
Reported as:
Mean · units
Absolute Change in Contrast Sensitivity With High Glare at 12 Months Compared to Baseline
unitsNitisinone
Frequency 1.51.6 ± 1.52
Frequency 32.2 ± 2.28
Frequency 62.6 ± 3.21
Frequency 121.8 ± 1.79
Frequency 180.0 ± 0.00
SecondaryAbsolute Change in Adjusted Melanin Index at 3 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

Time frame:
Baseline and 3 Months
Reported as:
Mean · Adjusted Melanin Index*10^-5
Absolute Change in Adjusted Melanin Index at 3 Months Compared to Baseline
Adjusted Melanin Index*10^-5Nitisinone
Forehead16.4 ± 14.95
Inner Bicep4.8 ± 5.24
Lower Back20.9 ± 18.91
Inner Forearm10.7 ± 5.52
Outer Forearm10.6 ± 5.60
SecondaryAbsolute Change in Adjusted Melanin Index at 6 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

Time frame:
Baseline and 6 Months
Reported as:
Mean · Adjusted Melanin Index*10^-5
Absolute Change in Adjusted Melanin Index at 6 Months Compared to Baseline
Adjusted Melanin Index*10^-5Nitisinone
Forehead11.8 ± 4.57
Inner Bicep8.2 ± 6.19
Lower Back9.3 ± 7.60
Inner Forearm12.1 ± 10.59
Outer Forearm12.6 ± 6.71
SecondaryAbsolute Change in Adjusted Melanin Index at 9 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

Time frame:
Baseline and 9 Months
Reported as:
Mean · Adjusted Melanin Index*10^-5
Absolute Change in Adjusted Melanin Index at 9 Months Compared to Baseline
Adjusted Melanin Index*10^-5Nitisinone
Forehead10.3 ± 13.41
Inner Bicep9.4 ± 5.85
Lower Back5.5 ± 4.12
Inner Forearm11.6 ± 7.82
Outer Forearm1.5 ± 0.98
SecondaryAbsolute Change in Adjusted Melanin Index at 12 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

Time frame:
Baseline and 12 Months
Reported as:
Mean · Adjusted Melanin Index*10^-5
Absolute Change in Adjusted Melanin Index at 12 Months Compared to Baseline
Adjusted Melanin Index*10^-5Nitisinone
Forehead8.3 ± 6.89
Inner Bicep7.0 ± 7.74
Lower Back4.2 ± 3.18
Inner Forearm6.8 ± 4.20
Outer Forearm8.6 ± 5.09
SecondaryPercent Change in Adjusted Melanin Index at 3 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

Time frame:
Baseline and 3 Months
Reported as:
Mean · Percentage change
Percent Change in Adjusted Melanin Index at 3 Months Compared to Baseline
Percentage changeNitisinone
Forehead50.1 ± 49.48
Inner Bicep40.1 ± 35.76
Lower Back201.0 ± 321.19
Inner Forearm83.3 ± 70.69
Outer Forearm42.1 ± 22.67
SecondaryPercent Change in Adjusted Melanin Index at 6 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

Time frame:
Baseline and 6 Months
Reported as:
Mean · Percentage change
Percent Change in Adjusted Melanin Index at 6 Months Compared to Baseline
Percentage changeNitisinone
Forehead35.4 ± 14.10
Inner Bicep123.0 ± 113.41
Lower Back117.4 ± 120.5
Inner Forearm91.1 ± 116.26
Outer Forearm67.9 ± 56.49
SecondaryPercent Change in Adjusted Melanin Index at 9 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

Time frame:
Baseline and 9 Months
Reported as:
Mean · Percentage change
Percent Change in Adjusted Melanin Index at 9 Months Compared to Baseline
Percentage changeNitisinone
Forehead33.2 ± 44.21
Inner Bicep94.5 ± 60.03
Lower Back39.6 ± 42.36
Inner Forearm81.0 ± 93.51
Outer Forearm6.0 ± 5.86
SecondaryPercent Change in Adjusted Melanin Index at 12 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

Time frame:
Baseline and 12 Months
Reported as:
Mean · Percentage change
Percent Change in Adjusted Melanin Index at 12 Months Compared to Baseline
Percentage changeNitisinone
Forehead24.7 ± 21.76
Inner Bicep104.5 ± 132.61
Lower Back32.7 ± 31.81
Inner Forearm47.4 ± 48.10
Outer Forearm30.5 ± 7.60
SecondaryAbsolute Change in Melanin Index at 3 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

Time frame:
Baseline and 3 Months
Reported as:
Mean · Melanin Index
Absolute Change in Melanin Index at 3 Months Compared to Baseline
Melanin IndexNitisinone
Forehead3.8 ± 3.02
Inner Bicep1.4 ± 0.69
Lower Back0.6 ± 0.63
Inner Forearm1.8 ± 1.12
Outer Forearm4.5 ± 4.45
SecondaryAbsolute Change in Melanin Index at 6 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

Time frame:
Baseline and 6 Months
Reported as:
Mean · Melanin Index
Absolute Change in Melanin Index at 6 Months Compared to Baseline
Melanin IndexNitisinone
Forehead2.2 ± 1.29
Inner Bicep2.7 ± 1.68
Lower Back3.3 ± 3.72
Inner Forearm2.1 ± 1.43
Outer Forearm4.4 ± 5.80
SecondaryAbsolute Change in Melanin Index at 9 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

Time frame:
Baseline and 9 Months
Reported as:
Mean · Melanin Index
Absolute Change in Melanin Index at 9 Months Compared to Baseline
Melanin IndexNitisinone
Forehead2.4 ± 1.98
Inner Bicep1.9 ± 1.60
Lower Back3.2 ± 3.23
Inner Forearm2.1 ± 1.33
Outer Forearm2.2 ± 2.48
SecondaryAbsolute Change in Melanin Index at 12 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

Time frame:
Baseline and 12 Months
Reported as:
Mean · Melanin Index
Absolute Change in Melanin Index at 12 Months Compared to Baseline
Melanin IndexNitisinone
Forehead3.7 ± 3.29
Inner Bicep2.3 ± 1.90
Lower Back2.0 ± 1.55
Inner Forearm2.2 ± 1.96
Outer Forearm3.4 ± 3.38
SecondaryPercent Change in Melanin Index at 3 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

Time frame:
Baseline and 3 Months
Reported as:
Mean · Percentage change
Percent Change in Melanin Index at 3 Months Compared to Baseline
Percentage changeNitisinone
Forehead15.0 ± 12.90
Inner Bicep6.7 ± 3.50
Lower Back2.8 ± 3.34
Inner Forearm8.6 ± 5.84
Outer Forearm18.9 ± 19.90
SecondaryPercent Change in Melanin Index at 6 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

Time frame:
Baseline and 6 Months
Reported as:
Mean · Percentage change
Percent Change in Melanin Index at 6 Months Compared to Baseline
Percentage changeNitisinone
Forehead8.4 ± 4.62
Inner Bicep12.7 ± 8.31
Lower Back17.0 ± 19.52
Inner Forearm10.2 ± 7.50
Outer Forearm19.2 ± 24.93
SecondaryPercent Change in Melanin Index at 9 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

Time frame:
Baseline and 9 Months
Reported as:
Mean · Percentage change
Percent Change in Melanin Index at 9 Months Compared to Baseline
Percentage changeNitisinone
Forehead9.2 ± 7.30
Inner Bicep8.9 ± 7.89
Lower Back15.8 ± 16.17
Inner Forearm9.5 ± 6.15
Outer Forearm8.8 ± 10.63
SecondaryPercent Change in Melanin Index at 12 Months Compared to Baseline

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows: Eqn 1= \[ (PR at 650nm + PR at 660nm + 0.5\*PR at 640nm + 0.5\*PR at 670nm)/3 \]/100; M index = 100\*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

Time frame:
Baseline and 12 Months
Reported as:
Mean · Percentage change
Percent Change in Melanin Index at 12 Months Compared to Baseline
Percentage changeNitisinone
Forehead14.7 ± 14.11
Inner Bicep10.9 ± 9.43
Lower Back10.2 ± 7.92
Inner Forearm10.4 ± 10.19
Outer Forearm13.3 ± 13.44
SecondaryAbsolute Change in Electroretinogram (ERG) at Month 6 as Compared to Baseline.

Amplitude for the ERG parameter, Dark Adaptation (DA) Comb B, was measured at each visit. Participants left and right eye will be analyzed.

Time frame:
Baseline and 6 months
Reported as:
Mean · µV
Absolute Change in Electroretinogram (ERG) at Month 6 as Compared to Baseline.
µVNitisinone
OD38.6 ± 27.93
OS76.2 ± 29.06
SecondaryAbsolute Change in Electroretinogram (ERG) at Month 12 as Compared to Baseline.

Amplitude for the ERG parameter, Dark Adaptation (DA) Comb B, was measured at each visit. Participants left and right eye will be analyzed.

Time frame:
Baseline and 12 months
Reported as:
Mean · µV
Absolute Change in Electroretinogram (ERG) at Month 12 as Compared to Baseline.
µVNitisinone
OD27.8 ± 16.66
OS85.8 ± 83.83
SecondaryQualitative Change in Hair Pigmentation at 3 Months Compared to Previous Visit.

Qualitative change in hair pigmentation was measured as a binary endpoint (no change vs. increase) at Month 3 compared to previous visit.

Time frame:
Baseline and 3 months
Reported as:
Count of participants · Participants
Qualitative Change in Hair Pigmentation at 3 Months Compared to Previous Visit.
ParticipantsNitisinone
No change in hair pigmentation1
Increase in hair pigmentation4
SecondaryQualitative Change in Hair Pigmentation at 6 Months Compared to Previous Visit.

Qualitative change in hair pigmentation was measured as a binary endpoint (no change vs. increase) at Month 6 compared to Month 3

Time frame:
3 Months and 6 months
Reported as:
Count of participants · Participants
Qualitative Change in Hair Pigmentation at 6 Months Compared to Previous Visit.
ParticipantsNitisinone
No change in hair pigmentation3
Increase in hair pigmentation2
SecondaryQualitative Change in Hair Pigmentation at 9 Months Compared to Previous Visit.

Qualitative change in hair pigmentation was measured as a binary endpoint (no change vs. increase) at Month 9 compared to Month 6

Time frame:
6 Months and 9 months
Reported as:
Count of participants · Participants
Qualitative Change in Hair Pigmentation at 9 Months Compared to Previous Visit.
ParticipantsNitisinone
No change in hair pigmentation4
Increase in hair pigmentation1
SecondaryQualitative Change in Hair Pigmentation at 12 Months Compared to Previous Visit.

Qualitative change in hair pigmentation was measured as a binary endpoint (no change vs. increase) at Month 12 compared to Month 9

Time frame:
9 Months and 12 months
Reported as:
Count of participants · Participants
Qualitative Change in Hair Pigmentation at 12 Months Compared to Previous Visit.
ParticipantsNitisinone
No change in hair pigmentation5
Increase in hair pigmentation0
SecondaryQualitative Change in Skin Pigmentation at 3 Months Compared to Previous Visit.

Qualitative change in skin pigmentation was measured as a binary endpoint (no change vs. increase) at Month 3 compared to previous visit.

Time frame:
Baseline and 3 months
Reported as:
Count of participants · Participants
Qualitative Change in Skin Pigmentation at 3 Months Compared to Previous Visit.
ParticipantsNitisinone
No change in skin pigmentation4
Increase in skin pigmentation1
SecondaryQualitative Change in Skin Pigmentation at 6 Months Compared to Previous Visit.

Qualitative change in skin pigmentation was measured as a binary endpoint (no change vs. increase) at Month 6 compared to Month 3

Time frame:
3 Months and 6 months
Reported as:
Count of participants · Participants
Qualitative Change in Skin Pigmentation at 6 Months Compared to Previous Visit.
ParticipantsNitisinone
No change in skin pigmentation5
Increase in skin pigmentation0
SecondaryQualitative Change in Skin Pigmentation at 9 Months Compared to Previous Visit.

Qualitative change in skin pigmentation was measured as a binary endpoint (no change vs. increase) at Month 9 compared to Month 6

Time frame:
6 Months and 9 months
Reported as:
Count of participants · Participants
Qualitative Change in Skin Pigmentation at 9 Months Compared to Previous Visit.
ParticipantsNitisinone
No change in skin pigmentation5
Increase in skin pigmentation0
SecondaryQualitative Change in Skin Pigmentation at 12 Months Compared to Previous Visit.

Qualitative change in skin pigmentation was measured as a binary endpoint (no change vs. increase) at Month 12 compared to Month 9

Time frame:
9 Months and 12 months
Reported as:
Count of participants · Participants
Qualitative Change in Skin Pigmentation at 12 Months Compared to Previous Visit.
ParticipantsNitisinone
No change in skin pigmentation5
Increase in skin pigmentation0
SecondaryQualitative Change in Fundus Pigmentation at 3 Months Compared to Previous Visit.

Qualitative change in fundus pigmentation was measured as a binary endpoint (no change vs. increase) at Month 3 compared to previous visit.

Time frame:
Baseline and 3 months
Reported as:
Count of participants · Participants
Qualitative Change in Fundus Pigmentation at 3 Months Compared to Previous Visit.
ParticipantsNitisinone
No change in fundus pigmentation5
Increase in fundus pigmentation0
SecondaryQualitative Change in Fundus Pigmentation at 6 Months Compared to Previous Visit.

Qualitative change in fundus pigmentation was measured as a binary endpoint (no change vs. increase) at Month 6 compared to Month 3

Time frame:
3 Months and 6 months
Reported as:
Count of participants · Participants
Qualitative Change in Fundus Pigmentation at 6 Months Compared to Previous Visit.
ParticipantsNitisinone
No change in fundus pigmentation5
Increase in fundus pigmentation0
SecondaryQualitative Change in Fundus Pigmentation at 9 Months Compared to Previous Visit.

Qualitative change in fundus pigmentation was measured as a binary endpoint (no change vs. increase) at Month 9 compared to Month 6

Time frame:
6 Months and 9 months
Reported as:
Count of participants · Participants
Qualitative Change in Fundus Pigmentation at 9 Months Compared to Previous Visit.
ParticipantsNitisinone
No change in fundus pigmentation5
Increase in fundus pigmentation0
SecondaryQualitative Change in Fundus Pigmentation at 12 Months Compared to Previous Visit.

Qualitative change in fundus pigmentation was measured as a binary endpoint (no change vs. increase) at Month 12 compared to Month 9

Time frame:
9 Months and 12 months
Reported as:
Count of participants · Participants
Qualitative Change in Fundus Pigmentation at 12 Months Compared to Previous Visit.
ParticipantsNitisinone
No change in fundus pigmentation5
Increase in fundus pigmentation0
SecondaryAbsolute Change in Hair Melanin at 12 Months Compared to Baseline

Hair melanin was assessed using pyrrole-2,3,5-tricarboxylic acid (PTCA), a marker of eumelanin and 4-amino-3-hydroxyphenylalanine (4-AHP), a marker of pheomelanin.

Time frame:
Baseline and 12 months
Reported as:
Mean · ng/mg
Absolute Change in Hair Melanin at 12 Months Compared to Baseline
ng/mgNitisinone
PTCA8.38 ± 5.11
4-AHP5.92 ± 11.68
SecondaryPercent Change in Hair Melanin at 12 Months Compared to Baseline

Hair melanin was assessed using pyrrole-2,3,5-tricarboxylic acid (PTCA), a marker of eumelanin and 4-amino-3-hydroxyphenylalanine (4-AHP), a marker of pheomelanin.

Time frame:
Baseline and 12 months
Reported as:
Mean · percentage change
Percent Change in Hair Melanin at 12 Months Compared to Baseline
percentage changeNitisinone
PTCA50.30 ± 45.92
4-AHP27.23 ± 23.22
Other pre-specifiedNumber of Ocular Adverse Events
Time frame:
Study duration, up to 18 months
Reported as:
Number · ocular adverse events
Number of Ocular Adverse Events
ocular adverse eventsNitisinone
Number of Ocular Adverse Events0
Other pre-specifiedNumber of Non-ocular Adverse Events
Time frame:
Study duration, up to 18 months
Reported as:
Number · non-ocular adverse events
Number of Non-ocular Adverse Events
non-ocular adverse eventsNitisinone
Number of Non-ocular Adverse Events10
Other pre-specifiedSeverity of Adverse Events
Time frame:
Study duration, up to 18 months
Reported as:
Number · adverse events
Severity of Adverse Events
adverse eventsNitisinone
Mild9
Moderate1
Other pre-specifiedNumber of Adverse Events Related to Investigational Product (IP)
Time frame:
Study duration, up to 18 months
Reported as:
Number · adverse events related to IP
Number of Adverse Events Related to Investigational Product (IP)
adverse events related to IPNitisinone
Number of Adverse Events Related to Investigational Product (IP)0
Other pre-specifiedNumber of Participants Withdrawn From Investigational Product (IP) Due to Safety and Abnormal Laboratory Results
Time frame:
Study duration, up to 18 months
Reported as:
Number · participant withdrawals
Number of Participants Withdrawn From Investigational Product (IP) Due to Safety and Abnormal Laboratory Results
participant withdrawalsNitisinone
Number of Participants Withdrawn From Investigational Product (IP) Due to Safety and Abnormal Laboratory Results0

Adverse events

Collected over Up to 18 months. Non-serious events are listed at a 0% frequency threshold.

Adverse event summary by group
GroupDeathsSeriousOther
Nitisinone0/5 (0%)0/5 (0%)5/5 (100%)
Most frequent other events
Most frequent other events
EventNitisinone
AnaemiaBlood and lymphatic system disorders1/5
PalpitationsCardiac disorders1/5
DizzinessGeneral disorders1/5
DyspepsiaGastrointestinal disorders1/5
Pain in extremityMusculoskeletal and connective tissue disorders1/5
Gastrooesophageal reflux diseaseGastrointestinal disorders1/5
HaemangiomaVascular disorders1/5
Neurological examination abnormalInvestigations1/5
Chest painCardiac disorders1/5
BronchitisRespiratory, thoracic and mediastinal disorders1/5

Baseline characteristics

Age, Categorical
Age, Categorical(Participants)Nitisinone
<=18 years0
Between 18 and 65 years5
>=65 years0
Age, Continuous
Age, Continuous(years)Nitisinone
Mean38.8 (24 to 52)
Sex: Female, Male
Sex: Female, Male(Participants)Nitisinone
Female3
Male2
Ethnicity (NIH/OMB)
Ethnicity (NIH/OMB)(Participants)Nitisinone
Hispanic or Latino0
Not Hispanic or Latino4
Unknown or Not Reported1
Race (NIH/OMB)
Race (NIH/OMB)(Participants)Nitisinone
American Indian or Alaska Native0
Asian0
Native Hawaiian or Other Pacific Islander0
Black or African American0
White4
More than one race0
Unknown or Not Reported1
08

Study locations

1 site
  • National Institutes of Health Clinical Center, 9000 Rockville Pike
    Bethesda, Maryland 20892, United States
09

References and documents

Publications

  • Hertle RW, Anninger W, Yang D, Shatnawi R, Hill VM. Effects of extraocular muscle surgery on 15 patients with oculo-cutaneous albinism (OCA) and infantile nystagmus syndrome (INS). Am J Ophthalmol. 2004 Dec;138(6):978-87. doi: 10.1016/j.ajo.2004.07.029. PubMed 15629289 ↗
  • Giebel LB, Tripathi RK, King RA, Spritz RA. A tyrosinase gene missense mutation in temperature-sensitive type I oculocutaneous albinism. A human homologue to the Siamese cat and the Himalayan mouse. J Clin Invest. 1991 Mar;87(3):1119-22. doi: 10.1172/JCI115075. PubMed 1900309 ↗
  • Giebel LB, Tripathi RK, Strunk KM, Hanifin JM, Jackson CE, King RA, Spritz RA. Tyrosinase gene mutations associated with type IB ("yellow") oculocutaneous albinism. Am J Hum Genet. 1991 Jun;48(6):1159-67. Erratum In: Am J Hum Genet 1991 Sep;49(3):696. PubMed 1903591 ↗
  • Adams DR, Menezes S, Jauregui R, Valivullah ZM, Power B, Abraham M, Jeffrey BG, Garced A, Alur RP, Cunningham D, Wiggs E, Merideth MA, Chiang PW, Bernstein S, Ito S, Wakamatsu K, Jack RM, Introne WJ, Gahl WA, Brooks BP. One-year pilot study on the effects of nitisinone on melanin in patients with OCA-1B. JCI Insight. 2019 Jan 24;4(2):e124387. doi: 10.1172/jci.insight.124387. PubMed 30674731 ↗
10

Timeline

Tracking since Sep 25, 2026
Not marked actual or estimatedDates not marked actual or estimated

The record gives a start of Apr 2013, a primary completion of Jul 2016 and a completion of Feb 2017. It does not say whether these dates are actual or estimated.

Results were first posted in Nov 2017, 1 year 4 months after primary completion.

How these figures are worked out, and which studies are left out of them.

Registered
Apr 20, 2013
First posted
Apr 24, 2013
Start
Apr 16, 2013
Primary completionActual
Jul 11, 2016
CompletionActual
Feb 7, 2017
Results first posted
Nov 17, 2017
Last update
Feb 26, 2019
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Feb 26, 2019, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
11

Registry details

Key details

Study ID
NCT01838655
Responsible party
Sponsor
First posted
Apr 24, 2013
Start date
Apr 16, 2013
Primary completion
Jul 11, 2016
Completion
Feb 7, 2017
Results posted
Nov 17, 2017
Last update
Feb 26, 2019

Study contacts

Brian P Brooks, M.D.
principal investigator · National Eye Institute (NEI)

Oversight

Data monitoring committee
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Oct 2017. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Studies of the drug tested here: Nitisinone

Start the discussion