Evaluation of a New Cardiac Biomarker Assay

A Phase 3 interventional study of ARCHITECT STAT High Sensitive Troponin I Assay in Acute Coronary Syndrome and Acute Myocardial Infarction, sponsored by Abbott Diagnostics Division. Completed at 12 sites in United States. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2015-03-17.

Sponsored by Abbott Diagnostics Division (part of Abbott) · Phase 3, Interventional, and Diagnostic

Phase
Phase 3
Study type
Interventional
Enrollment
1,101
Allocation
Not applicable
Ages
18 Years and older
Sex
All
01

Study summary

The objective of the study is to evaluate the performance and intended use of a new cardiac biomarker test, Troponin I, in an intended use population. Blood specimens will be tested using the new investigational test that detects the level of Troponin I. Results will be compared to the diagnosis of whether or not an acute myocardial infarction (MI) occurred.

Read the detailed description

The purpose of the cardiac biomarker Troponin I is to aid in the diagnosis of myocardial infarction.The assay is also intended to assist in the prognosis relative risk to all cause mortality (ACM) and major adverse cardiac events (MACE) consisting of myocardial infarction, revascularization, and cardiac death in patients who present with symptoms suggestive of acute coronary syndrome (ACS) without a diagnosis of myocardial infarction.

All specimens were collected under a separate specimen collection protocol (Protocol No, 7B5-02-09A01-01: Clinical Specimen Procurement for Biomarker Evaluation of Suspected ACS). The specimens that will be tested include approximately 8300 specimens collected from 1101 subjects presenting to Emergency Departments with signs and symptoms of Acute Coronary Syndrome and will be provided to the clinical sites performing investigational Troponin I testing.

02

Conditions studied

  • Acute Coronary Syndrome
  • Acute Myocardial Infarction
03

In context

Acute Coronary Syndrome

1,488 studies on the registry are indexed under Acute Coronary Syndrome; 273 are open to participants now.

This study's enrollment of 1,101 is above the median of 200 across 865 interventional studies indexed under Acute Coronary Syndrome.

Browse Acute Coronary Syndrome studies →

Lead sponsor

Abbott Diagnostics Division is the lead sponsor of 8 studies on the registry; none are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • presenting to the Emergency Department with symptoms consistent with or suggestive of Acute Coronary Syndrome (ACS) defined as at least 5 minutes of chest pain (or symptoms consistent with myocardial ischemia) up to 6 hours prior to initial evaluation.
  • an (ECG) result within 2 hours of presentation for observation of Acute Coronary Syndrome (ACS).
  • greater than 18 years of age.
  • not known to be pregnant.
  • agreement to the follow-up required by the study.

Exclusion criteria

Exclusion Criteria:

  • prior participation in this study.
  • require dialysis for end stage renal disease.
  • history of a previous heart transplant.
  • coexisting disorder associated with limited .
  • currently participating in another device or drug study.
Terms in these criteria, in plain language(3)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

ECG (electrocardiogram)

A recording of the heart’s electrical activity, taken with stickers on the chest, arms and legs. It takes a few minutes and does not hurt.

Life expectancy

The study doctor’s estimate of how long someone is likely to live. Criteria use it so that people can stay in the study long enough for it to answer its question.

Investigational drug or device

A drug or device being studied in a clinical trial.

It may be new, or already approved and being studied for another use, dose or form. Criteria often leave out people who took part in another study of one within a recent period, commonly 30 days or five half-lives.

05

Study design

Phase
Phase 3
Primary purpose
Diagnostic
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
1,101 participants (actual)

Study arms

  • Experimental
    ARCHITECT STAT High Sensitive Troponin I Assay testing

    All subjects will have their blood tested by the investigational ARCHITECT STAT High SensitiveTroponin I assay.

    Device: ARCHITECT STAT High Sensitive Troponin I Assay

Interventions

  • DeviceARCHITECT STAT High Sensitive Troponin I Assay

    Test blood samples from the ARCHITECT STAT High Sensitive Troponin I Assay. Results obtained will be used to assess the prognosis of subjects for risk of ACM/MACE in the timeframes (30 days and 90 days) after the Emergency Department visit. Troponin results will be compared to documented ACM/MACE events at the 30 day and 90 day time points after Emergency Department visit.

06

What researchers measure

Primary outcomes

  1. Clinical Performance - Area Under the Curve

    The ARCHITECT STAT High Sensitive Troponin-I assay clinical performance was evaluated by calculating the Area Under the Curve (AUC). The Area Under the Curve that was assessed, is used to determine the optimum clinical sensitivity and specificity for the ARCHITECT STAT High Sensitive Troponin-I assay. The ARCHITECT STAT High Sensitive Troponin-I assay results were generated from subject's specimens collected at three collection time points in three tube types (K2 EDTA, Lithium Heparin Separator and Serum Separator).

    Time frame: Troponin value from three collection time points (0-2 hours, >2 and up to 4 hours, >4 hours and up to 9 hours) from subject presentation to the emergency department

  2. Clinical Performance- Sensitivity

    The ARCHITECT STAT High Sensitive Troponin-I assay clinical performance was evaluated by calculating Sensitivity. The ARCHITECT STAT High Sensitive Troponin-I assay results were generated from subject's specimens collected at three collection time points in three tube types (K2 EDTA, Lithium Heparin Separator and Serum Separator).

    Time frame: Troponin value from three collection time points (0-2 hours, >2 and up to 4 hours, >4 hours and up to 9 hours) from subject presentation to the emergency department

  3. Clinical Performance- Specificity

    The ARCHITECT STAT High Sensitive Troponin-I assay clinical performance was evaluated by calculating Specificity. The ARCHITECT STAT High Sensitive Troponin-I assay results were generated from subject's specimens collected at three collection time points in three tube types (K2 EDTA, Lithium Heparin Separator and Serum Separator).

    Time frame: Troponin value from three collection time points (0-2 hours, >2 and up to 4 hours, >4 hours and up to 9 hours) from subject presentation to the emergency department.

  4. Clinical Performance- Negative Predictive Value (NPV)

    The ARCHITECT STAT High Sensitive Troponin-I assay clinical performance was evaluated by calculating Negative Predictive Value. The ARCHITECT STAT High Sensitive Troponin-I assay results were generated from subject's specimens collected at three collection time points in three tube types (K2 EDTA, Lithium Heparin Separator and Serum Separator).

    Time frame: Troponin value from three collection time points (0-2 hours, >2 and up to 4 hours, >4 hours and up to 9 hours) from subject presentation to the emergency department.

  5. Clinical Performance- Positive Predictive Value (PPV)

    The ARCHITECT STAT High Sensitive Troponin-I assay clinical performance was evaluated by calculating the Positive Predictive Value. The ARCHITECT STAT High Sensitive Troponin-I assay results were generated from subject's specimens collected at three collection time points in three tube types (K2 EDTA, Lithium Heparin Separator and Serum Separator).

    Time frame: Troponin value from three collection time points (0-2 hours, >2 and up to 4 hours, >4 hours and up to 9 hours) from subject presentation to the emergency department.

Secondary outcomes

  1. Prognosis

    Specimens were collected at 11 EDs from 1,101 subjects presenting to the ED with symptoms consistent with ACS. All subject diagnoses were adjudicated by three board certified cardiologists according to current standard of care. ARCHITECT STAT High Sensitive Troponin I results were generated from subject specimens and evaluated for use as an aid in the assessment of prognosis. Analyses used the first available troponin result from multiple serial draw time points. Subjects were assessed for risk of all cause mortality (ACM) and major adverse cardiac event (MACE) at 30 day and 90 day time points after ED discharge. MACE consisted of myocardial infarction, urgent revascularization, and cardiac death. Subjects were followed-up for subsequent events by medical record review and/or subject/caregiver contact. Any ACM and MACE that occurred during the ED visit and on the same day as ED discharge were not included in the analyses.

    Time frame: 30-day and 90-day follow-up

07

Results

Posted Mar 17, 2015
Limitations and caveats
Some tube types and some time points may not have been obtained for each subject. Every attempt was made to collect all tube types within the time point windows described.

Participant flow

Participant flow — Overall Study
MilestoneARCHITECT STAT High Sensitive Troponin I Assay Testing
Started1101
Completed1101
Not completed0

Outcome measures

PrimaryClinical Performance - Area Under the Curve

The ARCHITECT STAT High Sensitive Troponin-I assay clinical performance was evaluated by calculating the Area Under the Curve (AUC). The Area Under the Curve that was assessed, is used to determine the optimum clinical sensitivity and specificity for the ARCHITECT STAT High Sensitive Troponin-I assay. The ARCHITECT STAT High Sensitive Troponin-I assay results were generated from subject's specimens collected at three collection time points in three tube types (K2 EDTA, Lithium Heparin Separator and Serum Separator).

Time frame:
Troponin value from three collection time points (0-2 hours, >2 and up to 4 hours, >4 hours and up to 9 hours) from subject presentation to the emergency department
Reported as:
Number · Probability
Clinical Performance - Area Under the Curve
ProbabilityArea Under the Curve in K2 EDTAArea Under the Curve in Lithium Heparin SeparatorArea Under the Curve in Serum Separator
Area Under the Curve: 0-2 hours0.9326 (0.9048 to 0.9604)0.9197 (0.8914 to 0.9480)0.9412 (0.9102 to 0.9722)
Area Under the Curve: 2-4 hours0.9431 (0.9081 to 0.9782)0.9349 (0.8986 to 0.9712)0.9419 (0.9041 to 0.9796)
Area Under the Curve: 4-9 hours0.9503 (0.9419 to 0.9857)0.9498 (0.9190 to 0.9805)0.9449 (0.9046 to 0.9852)
Statistical analysis
  • Area Under the Curve in K2 EDTA · Area under the curve: 0.9326 · 95% CI 0.9048 to 0.9604
  • Area Under the Curve in K2 EDTA · Area under the curve: 0.9431 · 95% CI 0.9081 to 0.9782
  • Area Under the Curve in K2 EDTA · Area under the curve: 0.9503 · 95% CI 0.9419 to 0.9857
  • Area Under the Curve in Lithium Heparin Separator · Area under the curve: 0.9197 · 95% CI 0.8914 to 0.9480
  • Area Under the Curve in Lithium Heparin Separator · Area under the curve: 0.9349 · 95% CI 0.8986 to 0.9712
  • Area Under the Curve in Lithium Heparin Separator · Area under the curve: 0.9498 · 95% CI 0.9190 to 0.9805
  • Area Under the Curve in Serum Separator · Area under the curve: 0.9412 · 95% CI 0.9102 to 0.9722
  • Area Under the Curve in Serum Separator · Area under the curve: 0.9419 · 95% CI 0.9041 to 0.9796
  • Area Under the Curve in Serum Separator · Area under the curve: 0.9449 · 95% CI 0.9046 to 0.9852
SecondaryPrognosis

Specimens were collected at 11 EDs from 1,101 subjects presenting to the ED with symptoms consistent with ACS. All subject diagnoses were adjudicated by three board certified cardiologists according to current standard of care. ARCHITECT STAT High Sensitive Troponin I results were generated from subject specimens and evaluated for use as an aid in the assessment of prognosis. Analyses used the first available troponin result from multiple serial draw time points. Subjects were assessed for risk of all cause mortality (ACM) and major adverse cardiac event (MACE) at 30 day and 90 day time points after ED discharge. MACE consisted of myocardial infarction, urgent revascularization, and cardiac death. Subjects were followed-up for subsequent events by medical record review and/or subject/caregiver contact. Any ACM and MACE that occurred during the ED visit and on the same day as ED discharge were not included in the analyses.

Time frame:
30-day and 90-day follow-up
Reported as:
Number · participants
Prognosis
participants30-day Prognosis for K2 EDTA Tube Type90-day Prognosis for K2 EDTA Tube Type30-day Prognosis for Lithium Heparin Separator Tube Type90-day Prognosis for Lithium Heparin Separator Tube Type30-day Prognosis for Serum Separator Tube Type90-day Prognosis for Serum Separator Tube Type
MACE/ACM with Troponin value </= cutoff193017301729
No MACE/ACM (*Censored) with TnI value </= cutoff802791803790796784
MACE/ACM with Troponin value > cutoff173119341326
No MACE/ACM (*Censored) with TnI value > cutoff226212246231201188
Statistical analysis
  • 30-day Prognosis for K2 EDTA Tube Type · Log Rank · p = 0.0004 · Proportion percentage: 7.00Proportion percentage for subjects with ARCHITECT Troponin value greater than the cutoff
  • 30-day Prognosis for K2 EDTA Tube Type · Log Rank · p = 0.0004 · Proportion percentage: 2.31Proportion percentage for subjects with ARCHITECT Troponin value less than or equal to the cutoff
  • 30-day Prognosis for K2 EDTA Tube Type · Regression, Cox · p = 0.0011 (Likelihood Ratio) · Hazard ratio (hr): 3.09 · 95% CI 1.59 to 5.95
  • 90-day Prognosis for K2 EDTA Tube Type · Log Rank · p = <0.0001 · Proportion percentage: 12.76Proportion percentage for subjects with ARCHITECT Troponin value greater than the cutoff
  • 90-day Prognosis for K2 EDTA Tube Type · Log Rank · p = <0.0001 · Proportion percentage: 3.65Proportion percentage for subjects with ARCHITECT Troponin value less than or equal to the cutoff
  • 90-day Prognosis for K2 EDTA Tube Type · Regression, Cox · p = <0.0001 (Likelihood Ratio) · Hazard ratio (hr): 3.65 · 95% CI 2.21 to 6.05
  • 30-day Prognosis for Lithium Heparin Separator Tube Type · Log Rank · p = <0.0001 · Proportion percentage: 7.17Proportion percentage for subjects with ARCHITECT Troponin value greater than the cutoff
  • 30-day Prognosis for Lithium Heparin Separator Tube Type · Log Rank · p = <0.0001 · Proportion percentage: 2.07Proportion percentage for subjects with ARCHITECT Troponin value less than or equal to the cutoff
  • 30-day Prognosis for Lithium Heparin Separator Tube Type · Regression, Cox · p = 0.0002 (Likelihood Ratio) · Hazard ratio (hr): 3.54 · 95% CI 1.84 to 6.87
  • 90-day Prognosis for Lithium Heparin Separator Tube Type · Log Rank · p = <0.0001 · Proportion percentage: 12.83Proportion percentage for subjects with ARCHITECT Troponin value greater than the cutoff
  • 90-day Prognosis for Lithium Heparin Separator Tube Type · Log Rank · p = <0.0001 · Proportion percentage: 3.66Proportion percentage for subjects with ARCHITECT Troponin value less than or equal to the cutoff
  • 90-day Prognosis for Lithium Heparin Separator Tube Type · Regression, Cox · p = <0.0001 (Likelihood Ratio) · Hazard ratio (hr): 3.68 · 95% CI 2.25 to 6.05
  • 30-day Prognosis for Serum Separator Tube Type · Log Rank · p = 0.0020 · Proportion percentage: 6.07Proportion percentage for subjects with ARCHITECT Troponin value greater than the cutoff
  • 30-day Prognosis for Serum Separator Tube Type · Log Rank · p = 0.0020 · Proportion percentage: 2.09Proportion percentage for subjects with ARCHITECT Troponin value less than or equal to the cutoff
  • 30-day Prognosis for Serum Separator Tube Type · Regression, Cox · p = 0.0050 (Likelihood Ratio) · Hazard ratio (hr): 2.95 · 95% CI 1.41 to 6.05
  • 90-day Prognosis for Serum Separator Tube Type · Log Rank · p = <0.0001 · Proportion percentage: 12.15Proportion percentage for subjects with ARCHITECT Troponin value greater than the cutoff
  • 90-day Prognosis for Serum Separator Tube Type · Log Rank · p = <0.0001 · Proportion percentage: 3.57Proportion percentage for subjects with ARCHITECT Troponin value less than or equal to the cutoff
  • 90-day Prognosis for Serum Separator Tube Type · Regression, Cox · p = <0.0001 (Likelihood Ratio) · Hazard ratio (hr): 3.55 · 95% CI 2.08 to 6.03
PrimaryClinical Performance- Sensitivity

The ARCHITECT STAT High Sensitive Troponin-I assay clinical performance was evaluated by calculating Sensitivity. The ARCHITECT STAT High Sensitive Troponin-I assay results were generated from subject's specimens collected at three collection time points in three tube types (K2 EDTA, Lithium Heparin Separator and Serum Separator).

Time frame:
Troponin value from three collection time points (0-2 hours, >2 and up to 4 hours, >4 hours and up to 9 hours) from subject presentation to the emergency department
Reported as:
Number · percentage MI withTnI >cutoff vs all MI
Clinical Performance- Sensitivity
percentage MI withTnI >cutoff vs all MISensitivity in K2 EDTASensitivity in Lithium Heparin SeparatorSensitivity in Serum Separator
% Sensitivity: 0-2 hours84.44 (75.28 to 91.23)85.26 (76.51 to 91.70)87.32 (77.30 to 94.04)
% Sensitivity: 2-4 hours92.21 (83.81 to 97.09)91.86 (83.95 to 96.66)92.00 (83.40 to 97.01)
% Sensitivity: 4-9 hours93.90 (86.34 to 97.99)94.95 (88.61 to 98.34)93.15 (84.74 to 97.74)
Statistical analysis
  • Sensitivity in K2 EDTA · Percent sensitivity: 84.44 · 95% CI 75.28 to 91.23
  • Sensitivity in K2 EDTA · Percent sensitivity: 92.21 · 83.81% CI 83.81 to 97.09
  • Sensitivity in K2 EDTA · Percent sensitivity: 93.90 · 95% CI 86.34 to 97.99
  • Sensitivity in Lithium Heparin Separator · Percent sensitivity: 85.26 · 95% CI 76.51 to 91.70
  • Sensitivity in Lithium Heparin Separator · Percent sensitivity: 91.86 · 95% CI 83.95 to 96.66
  • Sensitivity in Lithium Heparin Separator · Percent sensitivity: 94.95 · 95% CI 88.61 to 98.34
  • Sensitivity in Serum Separator · Percent sensitivity: 87.32 · 95% CI 77.30 to 94.04
  • Sensitivity in Serum Separator · Percent sensitivity: 92.00 · 95% CI 83.40 to 97.01
  • Sensitivity in Serum Separator · Percent sensitivity: 93.15 · 95% CI 84.74 to 97.74
PrimaryClinical Performance- Specificity

The ARCHITECT STAT High Sensitive Troponin-I assay clinical performance was evaluated by calculating Specificity. The ARCHITECT STAT High Sensitive Troponin-I assay results were generated from subject's specimens collected at three collection time points in three tube types (K2 EDTA, Lithium Heparin Separator and Serum Separator).

Time frame:
Troponin value from three collection time points (0-2 hours, >2 and up to 4 hours, >4 hours and up to 9 hours) from subject presentation to the emergency department.
Reported as:
Number · % nonMI with TnI </= cutoff vs all nonMI
Clinical Performance- Specificity
% nonMI with TnI </= cutoff vs all nonMISpecificity in K2 EDTASpecificity in Lithium Heparin SeparatorSpecificity in Serum Separator
% Specificity: 0-2 hours85.73 (83.18 to 88.03)83.76 (81.12 to 86.17)86.35 (83.79 to 88.63)
% Specificity: 2-4 hours85.20 (82.66 to 87.50)83.72 (81.09 to 86.11)85.81 (83.31 to 88.07)
% Specificity: 4-9 hours82.82 (79.99 to 85.40)80.72 (77.82 to 83.39)84.05 (81.31 to 86.54)
Statistical analysis
  • Specificity in K2 EDTA · Percent specificity: 85.73 · 95% CI 83.18 to 88.03
  • Specificity in K2 EDTA · Percent specificity: 85.20 · 95% CI 82.66 to 87.50
  • Specificity in K2 EDTA · Percent specificity: 82.82 · 95% CI 79.99 to 85.40
  • Specificity in Lithium Heparin Separator · Percent specificity: 83.76 · 95% CI 81.12 to 86.17
  • Specificity in Lithium Heparin Separator · Percent specificity: 83.72 · 95% CI 81.09 to 86.11
  • Specificity in Lithium Heparin Separator · Percent specificity: 80.72 · 95% CI 77.82 to 83.39
  • Specificity in Serum Separator · Percent specificity: 86.35 · 95% CI 83.79 to 88.63
  • Specificity in Serum Separator · Percent specificity: 85.81 · 95% CI 83.31 to 88.07
  • Specificity in Serum Separator · Percent specificity: 84.05 · 95% CI 81.31 to 86.54
PrimaryClinical Performance- Negative Predictive Value (NPV)

The ARCHITECT STAT High Sensitive Troponin-I assay clinical performance was evaluated by calculating Negative Predictive Value. The ARCHITECT STAT High Sensitive Troponin-I assay results were generated from subject's specimens collected at three collection time points in three tube types (K2 EDTA, Lithium Heparin Separator and Serum Separator).

Time frame:
Troponin value from three collection time points (0-2 hours, >2 and up to 4 hours, >4 hours and up to 9 hours) from subject presentation to the emergency department.
Reported as:
Number · %nonMI,TnI</=cutoff vs all TnI</=cutoff
Clinical Performance- Negative Predictive Value (NPV)
%nonMI,TnI</=cutoff vs all TnI</=cutoffNegative Predictive Value in K2 EDTANegative Predictive Value in Lithium Heparin SeparatorNegative Predictive Value in Serum Separator
% NPV: 0-2 hours98.10 (96.82 to 98.95)98.08 (96.81 to 98.95)98.73 (97.61 to 99.42)
% NPV: 2-4 hours99.19 (98.25 to 99.70)99.05 (98.05 to 99.62)99.20 (98.27 to 99.71)
% NPV: 4-9 hours99.23 (98.22 to 99.75)99.24 (98.22 to 99.75)99.25 (98.26 to 99.76)
Statistical analysis
  • Negative Predictive Value in K2 EDTA · Negative predictive value: 98.10 · 95% CI 96.82 to 98.95
  • Negative Predictive Value in K2 EDTA · Negative predictive value: 99.19 · 95% CI 98.25 to 99.70
  • Negative Predictive Value in K2 EDTA · Negative predictive value: 99.23 · 95% CI 98.22 to 99.75
  • Negative Predictive Value in Lithium Heparin Separator · Negative predictive value: 98.08 · 95% CI 96.81 to 98.95
  • Negative Predictive Value in Lithium Heparin Separator · Negative predictive value: 99.05 · 95% CI 98.05 to 99.62
  • Negative Predictive Value in Lithium Heparin Separator · Negative predictive value: 99.24 · 95% CI 98.22 to 99.75
  • Negative Predictive Value in Serum Separator · Negative predictive value: 98.73 · 95% CI 97.61 to 99.42
  • Negative Predictive Value in Serum Separator · Negative predictive value: 99.20 · 95% CI 98.27 to 99.71
  • Negative Predictive Value in Serum Separator · Negative predictive value: 99.25 · 95% CI 98.26 to 99.76
PrimaryClinical Performance- Positive Predictive Value (PPV)

The ARCHITECT STAT High Sensitive Troponin-I assay clinical performance was evaluated by calculating the Positive Predictive Value. The ARCHITECT STAT High Sensitive Troponin-I assay results were generated from subject's specimens collected at three collection time points in three tube types (K2 EDTA, Lithium Heparin Separator and Serum Separator).

Time frame:
Troponin value from three collection time points (0-2 hours, >2 and up to 4 hours, >4 hours and up to 9 hours) from subject presentation to the emergency department.
Reported as:
Number · %MI,TnI >cutoff vs all TnI > cutoff
Clinical Performance- Positive Predictive Value (PPV)
%MI,TnI >cutoff vs all TnI > cutoffPositive Predictive Value in K2 EDTAPositive Predictive Value in Lithium Heparin SeparatorPositive Predictive Value in Serum Separator
% PPV: 0-2 hours38.78 (31.92 to 45.98)36.82 (30.43 to 43.56)35.84 (28.70 to 43.47)
% PPV: 2-4 hours35.68 (29.03 to 42.76)35.75 (29.43 to 42.45)35.94 (29.16 to 43.16)
% PPV: 4-9 hours36.49 (29.99 to 43.38)37.75 (31.71 to 44.09)35.05 (28.36 to 42.21)
Statistical analysis
  • Positive Predictive Value in K2 EDTA · Positive predictive value: 38.78 · 95% CI 31.92 to 45.98
  • Positive Predictive Value in K2 EDTA · Positive predictive value: 35.68 · 95% CI 29.03 to 42.76
  • Positive Predictive Value in K2 EDTA · Positive predictive value: 36.49 · 95% CI 29.99 to 43.38
  • Positive Predictive Value in Lithium Heparin Separator · Positive predictive value: 36.82 · 95% CI 30.43 to 43.56
  • Positive Predictive Value in Lithium Heparin Separator · Positive predictive value: 35.75 · 95% CI 29.43 to 42.45
  • Positive Predictive Value in Lithium Heparin Separator · Positive predictive value: 37.75 · 95% CI 31.71 to 44.09
  • Positive Predictive Value in Serum Separator · Positive predictive value: 35.84 · 95% CI 28.70 to 43.47
  • Positive Predictive Value in Serum Separator · Positive predictive value: 35.94 · 95% CI 29.16 to 43.16
  • Positive Predictive Value in Serum Separator · Positive predictive value: 35.05 · 95% CI 28.36 to 42.21

Adverse events

Collected over Duration of subject emergency department visit: 24 hours.. Non-serious events are listed at a 0% frequency threshold.

Adverse event summary by group
GroupDeathsSeriousOther
ARCHITECT STAT High Sensitive Troponin I Assay Testing—0/1,101 (0%)0/1,101 (0%)

Baseline characteristics

Age, Categorical
Age, Categorical(Participants)ARCHITECT STAT High Sensitive Troponin I Assay Testing
<=18 years0
Between 18 and 65 years746
>=65 years355
Sex: Female, Male
Sex: Female, Male(Participants)ARCHITECT STAT High Sensitive Troponin I Assay Testing
Female482
Male619
Race/Ethnicity, Customized
Race/Ethnicity, Customized(participants)ARCHITECT STAT High Sensitive Troponin I Assay Testing
Black300
White692
Hispanic62
Asian18
Other29
Observed Myocardial Infarction Prevalence
Observed Myocardial Infarction Prevalence(participants)ARCHITECT STAT High Sensitive Troponin I Assay Testing
Number Participants with Myocardial Infarction130
Number Participants without Myocardial Infarction971
08

Study locations

12 sites
  • Chandler Regional Medical Center
    Chandler, Arizona 85224, United States
  • Stanford University School of Emergency Medicine
    Palo Alto, California 94304, United States
  • Nationwide Laboratory Services
    Fort Lauderdale, Florida 33309, United States
  • John T Mather Memorial Hospital
    Port Jefferson, New York 11777, United States
  • Duke University Medical Center
    Durham, North Carolina 27710, United States
  • Cleveland Clinic Foundation
    Cleveland, Ohio 44195, United States
  • Pennsylvania State University- Hershey Medical Center
    Hershey, Pennsylvania 17033, United States
  • Hospital of the University of Pennsylvania
    Philadelphia, Pennsylvania 19104-4283, United States
  • Hospital Physicians in Clinical Research
    Austin, Texas 78752, United States
  • Hospital Physicians in Clinical Research
    Bryan, Texas 77802, United States
  • Dept of Emergency Medicine University of Virginia
    Charlottesville, Virginia 22908-2877, United States
  • St Joseph Hospital
    Bellingham, Washington 98225, United States
09

Timeline

Tracking since Sep 25, 2026
Not marked actual or estimatedDates not marked actual or estimated

The record gives a start of Jun 2012, a primary completion of Aug 2014 and a completion of Sep 2014. It does not say whether these dates are actual or estimated.

Results were first posted in Mar 2015, 7 months after primary completion.

How these figures are worked out, and which studies are left out of them.

Registered
May 21, 2012
First posted
May 30, 2012
Start
Jun 2012
Primary completionActual
Aug 2014
CompletionActual
Sep 2014
Results first posted
Mar 17, 2015
Last update
Mar 17, 2015
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Mar 17, 2015, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT01608100
Responsible party
Sponsor
First posted
May 30, 2012
Start date
Jun 2012
Primary completion
Aug 2014
Completion
Sep 2014
Results posted
Mar 17, 2015
Last update
Mar 17, 2015

Study contacts

Fred S Apple, PhD
principal investigator · Hennepin Healthcare Research Institute
Frank Peacock, MD
study chair

Oversight

Data monitoring committee
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Jan 2015. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion