An interventional study of Manipulation in Sacroiliac Joint Pain, sponsored by Logan College of Chiropractic. Completed at 1 site in United States. Open to participants aged 20 Years to 40 Years, including healthy volunteers. Per ClinicalTrials.gov, last updated 2013-05-03.
Sponsored by Logan College of Chiropractic · Not applicable, Interventional, and Treatment
The purpose of this study is to examine the effects of manipulation on sacroiliac joint motion using a Polhemus motion capture system.
The Sacroiliac (SI) joint is a diarthrodial joint with the contradictory biomechanical function of transmitting compressive loads from the lumbar spine to the lower extremity while maintaining a nutating motion in the pelvis.
Recent studies identify the Sacroiliac (SI) joints as a significant source of pain in patients with chronic low back pain, contributing up to 27%. Recent studies have demonstrated that historical and physical examination findings and radiological imaging alone are insufficient to diagnose SI joint pain.
The purpose of this study is to examine the effects of manipulation on sacroiliac joint motion using a Polhemus motion capture system. The Absolute angular deviation of sacroiliac joint motion will be assessed during the normal gait cycle with the Polhemus Liberty motion capture system. Six sensors will be attached to specific anatomical landmarks of the pelvis which recorded motion characteristics while walking on a treadmill at 5 mph. The subjects then receive a HVLA manipulation to the SI joint and were retested at the same treadmill speed.
The Motion capture system tracks objects at a speed of 240 updates per second on all sensors simultaneously. The latency of data sampling is less than 4ms; 240 x 60 sec x 8 Sensors totaling 115,200 data points per minute. The system generates and tracks electromagnetic fields (EMF), computes position and orientation of sensors in an X, Y, and Z coordinate system while interfacing with a computer. The EMF source contains electromagnetic coils that emit a magnetic field. The source is the system's reference frame for sensor measurements. The sensor contains electromagnetic coils (accelerometers) that detect the position and orientation of the magnetic fields emitted by the EMF source.
273 studies on the registry are indexed under Arthralgia; 41 are open to participants now.
This study's enrollment of 20 is below the median of 63 across 219 interventional studies indexed under Arthralgia.
Browse Arthralgia studies →Logan College of Chiropractic is the lead sponsor of 48 studies on the registry; none are open to participants now.
Counted across the registry records on this site, refreshed daily.
Exclusion Criteria:
Manipulation
Procedure: Manipulation
HVLA manipulation to Sacroiliac Joint
Sacroiliac joint motion was assessed with the Polhemus Liberty motion capture system.
Time frame: Pre and Post therapy
This study is completed, as verified in May 2013. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Logan College of Chiropractic