An interventional study of Monoferric Injectable Product and Apple Watch in Heart Failure and Iron Deficiency, sponsored by University Health Network, Toronto. Not yet recruiting at 1 site in Canada. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2026-11-25.
Sponsored by University Health Network, Toronto · Not applicable, Interventional, and Treatment
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 20 studies in Heart Failure by University Health Network, Toronto — 4 open to participants now, 7 under way, none of them phase 3. Heart Failure · University Health Network, Toronto.
Among the 20 studies in Heart Failure by University Health Network, Toronto, this one is the 7th largest by planned enrollment of the 15 interventional ones that give a count, is the only one that started in 2026, is one of 12 with no phase, and was the 21st registered.
6,342 studies on the registry are indexed under Heart Failure; 1,395 are open to participants now.
Browse Heart Failure studies →4 of the 20 studies in Heart Failure by University Health Network, Toronto are open now, in 2 countries. Recruiting first, the newest first:
University Health Network, Toronto · Sites in Canada
Ages 18+
University Health Network, Toronto · Sites in Canada
Ages 18–45
University Health Network, Toronto · Sites in Canada
Ages 18+
University Health Network, Toronto · Sites in Qatar
Ages 18+
By country, each count listing its studies:
Of the 965 Heart Failure studies recruiting now, 688 (71%) set no upper age limit and 90 (9%) stop at 75 or younger; 64 take children under 18; 96 take healthy volunteers.
This study: 18 Years and older · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
20 studies; the count open now beside each. This study's row is marked.
First in 2009; this study’s year is marked. 1 started in 2026.
By drug class, each counting the studies that test any of its medicines:
This study's planned enrollment of 100 is above the median of 76 across 4,053 interventional studies indexed under Heart Failure.
Median enrollment 96 across the 15 interventional studies, 360 across the 5 observational. Of the 9 that completed or were terminated, 2 (22%) have results posted.
This tab as a report to print or save as PDF → With an account.
University Health Network, Toronto is the lead sponsor of 1,442 studies on the registry; 297 are open to participants now.
Of its 17 completed or terminated interventional studies of FDA-regulated products, 3 (18%) have results posted.
1 of the studies in Heart Failure by University Health Network, Toronto that are under way reach primary completion within a year, 0 of them phase 3. Phase 3 first, then by date:
| Study | Primary completion |
|---|---|
| NCT05543720University Health Network, TorontoEvaluation of Nurse-led Integrated Care of Complex Patients Facilitated By Telemonitoring: The SMaRT Study | 2026-12 |
Add it to your calendar (.ics) → With an account.
Among the 20 studies in Heart Failure by University Health Network, Toronto, from their registry updates:
Nothing recorded among them since 2026-09-25.
This tab as a report to print or save as PDF → With an account.
The goal of this clinical trial is to learn whether wearable devices can accurately monitor health changes in adults with heart failure with reduced ejection fraction (HFrEF) and iron deficiency. The study will also evaluate how and when intravenous (IV) iron improves exercise capacity, sleep, stress, and other health measures in this population. The main questions it aims to answer are:
How does IV iron affect exercise performance measured by cardiopulmonary exercise testing (CPET)? How accurate are lab-built wearable devices compared with standard CPET equipment? Can commercial wearable devices such as the Apple Watch and Oura Ring reliably monitor heart rate, oxygen levels, activity, sleep, and stress over time in people with HFrEF and iron deficiency?
Researchers will compare participants who receive IV iron at the start of the study with participants who receive IV iron after the final study visit to see how iron treatment changes exercise capacity and wearable device measurements.
Participants will:
Iron deficiency affects 70% of Heart failure patients with reduced Ejection Fraction (HFrEF), negatively impacting quality of life through reduced exercise capacity, sleep disruption (insomnia and restless leg syndrome), increased stress due to downstream effects on the nervous system, and overall poorer outcomes. IV iron therapy has been shown to improve improve quality of life and reduce hospitalizations and mortality in patients with HF. Iron repletion is also associated with improved exercise capacity; however, the kinetics of this improvement have not been elucidated. Wearable devices, such as smartwatches and fitness trackers, hold promise as they can monitor and provide real-time on data vital signs, including heart rate, blood oxygen levels, and activity levels.
The use and integration of wearable technologies has greatly increased in recent years, offering potential benefits in the management of chronic conditions. The feasibility and performance of wearable devices, such as the Apple watch, have been studied in HF cohorts with promising results, showing that Apple watch's single-lead ECG can identify atrial fibrillation (AF), showing that 87% of transmitted ECGs prompted scalable and timely healthcare interventions.
Wearable technologies, like the Apple Watch and Oura Ring could be particularly valuable for heart failure patients. However, a critical limitation is the lack of rigorous validation of these commercial devices in heart failure populations, especially among patients with advanced disease and iron deficiency. Most validation studies to date have been conducted in healthy individuals.
We aim to understand and illustrate how commercial and lab-built wearable devices perform within the iron deficient HFrEF population. This will provide a more comprehensive assessment of the potential for continuous monitoring and detection of deterioration and potentially iron deficiency through commercial wearables in this patient group.
Based on previous studies, we hypothesize that intravenous iron will improve exercise tolerance, CPET performance, sleep, and stress in iron-deficient patients with HFrEF. Improved exercise tolerance is expected to allow participants to safely complete a wider range of exercise workloads, which is necessary to accurately assess, validate, and interpret VO₂ measurements across different exercise intensities.
Primary Objectives
Secondary Objectives:
To measure and meet these objectives, we randomly assign participants to either receive IV iron with the first CPET (intervention) or not receive IV iron until second CPET. We will then use both commercial (Apple Watch and Oura Ring) and lab-built wearable technologies to monitor and passively collect cardiovascular data and activity-related health metrics in both patient groups to observe how IV iron affects patients with HF.
By administering IV iron, we are attempting to intentionally improve participants physiological performance allowing us to (1) validate device fidelity under improved physiological conditions, (2) visualize kinetic changes associated with IV iron (Improved pVO2, Improved sleep, reduced stress, etc.) and (3) assess accuracy and reliability of the smart-wearable devices in both their baseline state and a state of potentially improved exercise capacity. This will allow us to understand how these devices perform across a spectrum of physiological states within the iron deficient HFrEF population, revealing a more comprehensive clinical picture through continuous monitoring and possibly allowing us to pinpoint key changes associated with iron deficiency and decompensation through commercial wearables in patients with HF. This could lead to earlier and more systematized routine management of HFrEF patients enabling early detection of iron deficiency and general clinical deterioration potentially improving care, preventing hospitalizations, and improving QOL.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
The protein in red blood cells that carries oxygen. A low level is anemia, which can cause tiredness and breathlessness. Measured in g/dL or g/L (9 g/dL is 90 g/L).
The share of blood the heart’s main pumping chamber (the left ventricle) pushes out with each beat, measured by an echocardiogram (heart ultrasound) or a MUGA scan. About 50–70% is normal.
An allergy, or another reaction of the immune system, to a substance. “Hypersensitivity to the study drug” means a known allergic reaction to it — not every side effect a medicine can have.
Hemoglobin (Hb)
The protein in red blood cells that carries oxygen. A low level is anemia, which can cause tiredness and breathlessness. Measured in g/dL or g/L (9 g/dL is 90 g/L).
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
LVEF (left ventricular ejection fraction)
The share of blood the heart’s main pumping chamber (the left ventricle) pushes out with each beat, measured by an echocardiogram (heart ultrasound) or a MUGA scan. About 50–70% is normal.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Hypersensitivity
An allergy, or another reaction of the immune system, to a substance. “Hypersensitivity to the study drug” means a known allergic reaction to it — not every side effect a medicine can have.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Participants receiving IV Iron, will receive a single dose of Monoferric as part of their initial CPET visit (Day 30 of the study).
Drug: Monoferric Injectable Product · Device: Apple Watch · Device: Oura Ring
This arm will serve as a comparator and will undergo all the same study activities as the intervention arm; however, they will not receive IV Iron (a single dose of Monoferric) until their second and final CPET visit (Day 120 of the study).
Device: Apple Watch · Device: Oura Ring
A single dose of IV Monoferric is the only study intervention.
An apple watch will be given to each participant - with an iPhone
An Oura Ring will be given to each participant
Effect of IV iron on exercise capacity - Change in pVO2
Peak oxygen consumption (pVO2) will be measured using gold-standard cardiopulmonary exercise testing (CPET). Change in exercise capacity will be quantified as the change in pVO2, reported in mL/kg/min, between the Day 30 and Day 120 CPET assessments in the intervention and control groups.
Time frame: From intervention (Day 30) to offboarding (Day 120)
Accuracy of lab-built devices - Heart Rate
The degree of agreement between heart rate measured by the Franklin Research Lab-built devices and heart rate measured by the reference ECG/cardiac monitoring system used during CPET in both groups of iron deficient HFrEF patients. Agreement will be evaluated by comparing paired heart rate measurements, reported in beats per minute (bpm), obtained during the resting, unloaded warm-up, incremental exercise, and recovery phases of CPET.
Time frame: From baseline (Day 30) to offboarding (Day 120)
Accuracy of lab-built devices - SpO2
The degree of agreement between peripheral oxygen saturation (SpO2) measured by the Franklin Research Lab-built devices and SpO2 measured by the reference pulse oximetry system used during CPET in both groups of iron deficient HFrEF patients. Agreement will be evaluated by comparing paired SpO2 measurements, reported as percent oxygen saturation (%), obtained during the resting, unloaded warm-up, incremental exercise, and recovery phases of CPET.
Time frame: From baseline (Day 30) to offboarding (Day 120)
Accuracy of lab-built devices - Systolic Blood Pressure
The degree of agreement between systolic blood pressure measured by the Franklin Research Lab-built devices and systolic blood pressure measured by the reference blood pressure monitoring system used during CPET in both groups of iron deficient HFrEF patients. Agreement will be evaluated by comparing paired systolic blood pressure measurements, reported in millimetres of mercury (mmHg), obtained during the resting, unloaded warm-up, incremental exercise, and recovery phases of CPET.
Time frame: From baseline (Day 30) to offboarding (Day 120)
Accuracy of lab-built devices - Diastolic Blood Pressure
The degree of agreement between diastolic blood pressure measured by the Franklin Research Lab-built devices and systolic blood pressure measured by the reference blood pressure monitoring system used during CPET in both groups of iron deficient HFrEF patients. Agreement will be evaluated by comparing paired systolic blood pressure measurements, reported in millimetres of mercury (mmHg), obtained during the resting, unloaded warm-up, incremental exercise, and recovery phases of CPET.
Time frame: From baseline (Day 30) to offboarding (Day 120)
Accuracy of lab-built devices - Peak Oxygen Consuption
The degree of agreement between peak oxygen consumption (pVO2) will be estimated by the Franklin Research Lab-built devices and pVO2 measured using the gold-standard CPET metabolic measurement system in both groups of iron deficient HFrEF patients. Agreement will be evaluated by comparing paired peak pVO2 measurements, reported in mL/kg/min, obtained during each CPET assessment.
Time frame: From baseline (Day 30) to offboarding (Day 120)
Feasibility of Commercial Wearable Devices - Attrition
To evaluate the feasibility of using the Apple Watch and Oura Ring wearable devices in daily life we will assess: attrition - measured using study enrolment and completion records. The outcome will be calculated as the % of enrolled participants who discontinue wearable monitoring before completing the study.
Time frame: From onboarding (Day 0) to offboarding (Day 120)
Feasibility of Commercial Wearable Devices - Adherence
To evaluate the feasibility of using the Apple Watch and Oura Ring wearable devices in daily life we will assess the following parameter: Adherence to protocol - Adherence to wearable monitoring will be assessed using device data records. The outcome will be calculated as the % of expected monitoring days for which usable wearable data are obtained.
Time frame: From onboarding (Day 0) to offboarding (Day 120)
Feasibility of Commercial Wearable Devices - Survey Completion
To evaluate the feasibility of using the Apple Watch and Oura Ring wearable devices in daily life we will assess the following parameter: Survey entry or completion - Survey adherence will be measured using study database records. The outcome will be calculated as the % of scheduled participant surveys completed.
Time frame: From onboarding (Day 0) to offboarding (Day 120)
Feasibility of Commercial Wearable Devices - Offboarding Proportion
To evaluate the feasibility of using the Apple Watch and Oura Ring wearable devices in daily life we will assess the following parameter: offboarding proportion - Completion of wearable offboarding will be assessed using study records. The outcome will be calculated as the % of participants completing all prespecified offboarding procedures.
Time frame: From onboarding (Day 0) to offboarding (Day 120)
Comparing the Accuracy of Commercial and Lab-built Devices - Heart Rate
Assess the difference in accuracy between lab-built and commercial device measurements of key physiological metrics during CPET. First, Heart rate (bpm) measured by the Franklin Research Lab-built device, Apple Watch, and Oura Ring will be compared with the reference heart rate measurement obtained during the CPET. Measurement error will be calculated for each device relative to the reference measurement, and differences in measurement error between the lab-built and commercial devices will be assessed.
Time frame: From enrolment (Day 0) to offboarding (Day 120)
Comparing the Accuracy of Commercial and Lab-built Devices - SpO2
Assess the difference in accuracy between lab-built and commercial device measurements of key physiological metrics during CPET. Second, oxygen saturation (Sp02; %) measured by the Franklin Research Lab-built device, Apple Watch, and Oura Ring will be compared with the reference SpO2 measurement obtained during the CPET. Measurement error will be calculated for each device relative to the reference measurement, and differences in measurement error between the lab-built and commercial devices will be assessed.
Time frame: From enrolment (Day 0) to offboarding (Day 120)
Comparing the Accuracy of Commercial and Lab-built Devices - pVO2
Assess the difference in accuracy between lab-built and commercial device measurements of key physiological metrics during CPET. First, peak oxygen consumption (mL/kg/min; or VO2 Max) measured by the Franklin Research Lab-built device, Apple Watch, and Oura Ring will be compared with the reference pVO2 measurement obtained during the CPET. Measurement error will be calculated for each device relative to the reference measurement, and differences in measurement error between the lab-built and commercial devices will be assessed.
Time frame: From enrolment (Day 0) to offboarding (Day 120)
Patient Reported Usability
Participants will rate the usability of commercial wearable devices and the study application using the system usability scale (SUS). The questionnaire will assess participants' experience using the devices, including ease of use and ability to incorporate the devices into daily activities. A total usability score will be calculated according to the SUS scoring method.
Time frame: From enrolment (Day 0) to offboarding (Day 120)
Impact of Patient-level Factors on Wearable Devices
Skin pigmentation will be assessed using the Monk Skin Tone Scale, a 10-point visual scale ranging from lighter to darker skin tones. The association between Monk Skin Tone Scale score and device measurement accuracy will be evaluated for cardiovascular parameters obtained from commercial wearable devices and Franklin Research Lab-built devices in iron-deficient patients with HFrEF. Device accuracy will be assessed by comparing device-derived measurements with the corresponding reference measurements obtained during study assessments. Measurement error will be evaluated across Monk Skin Tone Scale values to determine whether device accuracy varies according to skin pigmentation in the intervention and control groups.
Time frame: From enrolment (Day 0) to offboarding (Day 30)
Ability of lab-built devices to estimate hemoglobin status and screening for iron deficiency
Determine the ability and accuracy of lab-built devices and tests to estimate hemoglobin status and detect iron deficiency or anemia. Hemoglobin concentration estimated using the lab-built device will be compared with hemoglobin concentration (g/L) measured using clinical laboratory testing. The lab-built devices use bioimpedance and optical spectroscopy-including short-wave infrared (SWIR) technologies-to detect independent spectral signatures of water and hemoglobin. Accuracy will be quantified as the difference between paired hemoglobin measurements.
Time frame: From enrolment (Day 0) to offboarding (Day 30)
Plan to share: Undecided — Participant data will be available upon reasonable request.
Start is estimated for Dec 2026; primary completion for Nov 2028, 23 months later.
Of 1,119 non-industry interventional studies with no phase under Heart Failure, half reached primary completion within 29 months of starting (the median), counting those still running; a quarter within 16 and three quarters within 50. This study's planned 23 months is below that.
Counting every sponsor, half of 1,355 studies reached it within 31 months; a quarter within 16 and three quarters within 52.
How these figures are worked out, and which studies are left out of them.
From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗
This study is not yet recruiting, as verified in Nov 2026. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
University Health Network, Toronto →