ClinicalTrials.gg
Enrolling by invitationNCT07913581Huawei-SunU01Updated Nov 3, 2026

Real-World Validation of A Huawei Smartwatch for Hypertension Risk Screening in Malaysia

An observational study in Hypertension, Vascular Disease Risk and Cardiovascular (CV) Risk, sponsored by Sunway University. Enrolling by invitation at 1 site in Malaysia. Open to participants aged 18 Years and older, including healthy volunteers. Per ClinicalTrials.gov, last updated 2026-11-03.

Sponsored by Sunway University · Observational

Updated Nov 3, 2026Newly registeredGo to Updates ↓
Study type
Observational
Model
Ecologic or community
Time perspective
Cross-sectional
Enrollment
500
Ages
18 Years and older
Sex
All
01

Study summary

Background:

Hypertension (high blood pressure) is a major risk factor for heart disease and stroke, yet many people do not know they have it. In Malaysia, nearly half of all adults with elevated blood pressure are unaware of their condition. Standard clinic blood pressure checks can miss cases of high blood pressure or falsely flag temporary stress-related spikes. While 24-hour Ambulatory Blood Pressure Monitoring (ABPM) is the standard method for an accurate diagnosis, it is not practical for large-scale screening.

Purpose:

The purpose of this study is to evaluate whether a novel Huawei smartwatch, which uses photoplethysmography (PPG) technology to estimate blood pressure, can accurately identify individuals at high risk for hypertension in a real-world setting.

Study Design \& Procedures:

Participants: Approximately 500 adults will be enrolled over a 24-month study period.

Screening: All participants will use the Huawei smartwatch screening tool to monitor their blood pressure estimates.

Validation: A subgroup of approximately 50 participants identified as high-risk by the smartwatch will undergo 24-hour ABPM (the clinical gold standard) to confirm whether they have high blood pressure.

Goal:

Researchers aim to validate the accuracy of the smartwatch screening tool against 24-hour ABPM to determine if wearable technology can support early detection and timely treatment of undiagnosed hypertension in the community.

02

Conditions studied

  • Hypertension
  • Vascular Disease Risk
  • Cardiovascular (CV) Risk
  • Masked Hypertension
  • White Coat Hypertension

Browse trials for

Keywords

  • Hypertension
  • High Blood Pressure
  • Photoplethysmography (PPG)
  • Ambulatory Blood Pressure Monitoring (ABPM)
  • 24-Hour Ambulatory Blood Pressure
  • Wearable Health Devices
  • Smartwatch Blood Pressure Screening
  • Cardiovascular Disease Risk
  • Screening and Early Detection
  • Masked Hypertension
  • White-Coat Hypertension
03

In context

Hypertension

6,845 studies on the registry are indexed under Hypertension; 976 are open to participants now.

This study's planned enrollment of 500 is above the median of 212 across 1,393 observational studies indexed under Hypertension.

Browse Hypertension studies →

Lead sponsor

Sunway University is the lead sponsor of 11 studies on the registry; 7 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
Yes
Sampling method
Non-probability sample

Study population

Community-based sample of multi-ethnic Malaysian adults aged 18 years and older. Participants are recruited across Malaysia using digital advertisements via the Huawei Research Platform app, Sunway University community outreach programs, health screening events, corporate wellness initiatives, social media, and primary care clinic referrals. The population includes individuals with compatible smartphones who are willing to wear monitoring devices continuously to assess hypertension risk.

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Possesses the specific Huawei wearable required for the study
  • Aged ≥18 years
  • Malaysian citizen/permanent resident
  • Understands English, Malay, or Chinese
  • Able to download the required application on a compatible smartphone
  • Willing to wear devices continuously
  • Able to provide informed consent.

Exclusion criteria

Exclusion Criteria:

  • Current pregnancy
  • Implantable cardiac devices (e.g., permanent pacemakers, implantable cardioverter-defibrillators [ICDs])
  • Uncontrolled arrhythmias (e.g., active atrial fibrillation, frequent premature ventricular contractions [PVCs])
  • Movement disorders or active tremors that interfere with signal acquisition (e.g., severe Parkinson's disease, essential tremor)
  • Acute medical conditions, including:
  • Acute coronary syndromes (e.g., recent myocardial infarction or unstable angina within the past 3 months)
  • Acute cerebrovascular events (e.g., stroke or transient ischemic attack [TIA] within the past 3 months)
  • Acute decompensated heart failure or severe respiratory distress Active, severe acute infections or systemic inflammatory illness (e.g., sepsis, acute pneumonia)
  • Hypertensive emergencies or urgency
  • Currently on antihypertensive medications
  • Resting BP ≥180/110 mmHg.
05

Study design

Observational model
Ecologic or community
Time perspective
Cross-sectional
Enrollment
500 participants (estimated)
Target follow-up
2 Years
Patient registry
Yes

Groups and cohorts

  • Screening Population

    Adults enrolled in the community screening phase who undergo non-invasive blood pressure estimation using the Huawei PPG smartwatch over the 24-month study period.

  • High-Risk Validation Cohort

    A targeted subset of participants (n = 50) identified as high-risk for hypertension by the Huawei smartwatch screening tool, who undergo 24-hour Ambulatory Blood Pressure Monitoring (ABPM) to confirm their diagnostic status.

06

What researchers measure

Primary outcomes

  1. Diagnostic Accuracy (AUC-ROC) of the Huawei PPG Smartwatch Hypertension Risk Algorithm Compared to 24-Hour Ambulatory Blood Pressure Monitoring (ABPM)

    Measure Description: Area Under the Receiver Operating Characteristic Curve (AUC-ROC) evaluated by comparing the binary high-risk classification flags generated by the Huawei PPG smartwatch algorithm directly against diagnostic confirmation from clinical 24-hour ABPM. Unit of Measure: Score on a scale from 0.0 to 1.0 (where 0.5 represents chance performance and 1.0 represents perfect discrimination)

    Time frame: Month 11 through Month 18.

  2. Diagnostic Sensitivity of the Huawei PPG Smartwatch Hypertension Risk Algorithm

    Measure Description: The proportion of participants with true ABPM-confirmed hypertension who are correctly identified as high-risk by the Huawei PPG smartwatch algorithm. Unit of Measure: Percentage of true positive cases

    Time frame: Month 11 through Month 18.

  3. Diagnostic Specificity of the Huawei PPG Smartwatch Hypertension Risk Algorithm

    Measure Description: The proportion of participants without ABPM-confirmed hypertension who are correctly identified as low-risk by the Huawei PPG smartwatch algorithm. Unit of Measure: Percentage of true negative cases

    Time frame: Month 11 through Month 18.

  4. Positive Predictive Value (PPV) of the Huawei PPG Smartwatch Hypertension Risk Algorithm

    Measure Description: The probability that a participant flagged as high-risk by the Huawei PPG smartwatch algorithm actually has hypertension confirmed by 24-hour ABPM. Unit of Measure: Percentage

    Time frame: Month 11 through Month 18

  5. Negative Predictive Value (NPV) of the Huawei PPG Smartwatch Hypertension Risk Algorithm

    Measure Description: The probability that a participant flagged as low-risk by the Huawei PPG smartwatch algorithm actually does not have hypertension confirmed by 24-hour ABPM. Unit of Measure: Percentage

    Time frame: Month 11 through Month 18

Secondary outcomes

  1. Participant Adherence to Huawei Wearable Monitoring Protocols

    Measure Description: The proportion of enrolled participants who achieve minimum complete wearable datasets, defined as continuous daily wear of the Huawei smartwatch to track PPG, heart rate, physical activity, and sleep metrics. Unit of Measure: Percentage of enrolled participants

    Time frame: Month 1 through Month 12 (up to 12 months per participant)

  2. Participant Usability and Acceptance Score Measured via Post-Monitoring Questionnaire

    Measure Description: Total score evaluating participant satisfaction, device comfort, and acceptance of the Huawei wearable for hypertension screening, measured using a standardized post-monitoring user experience questionnaire. Unit of Measure: Mean score on a 1 to 5 Likert scale (where 1 = Strongly Disagree/Poor and 5 = Strongly Agree/Excellent)

    Time frame: At the completion of the wearable monitoring phase (Month 12).

Other outcomes

  1. Prevalence of Wearable-Identified High-Risk Flags in the Study Population

    Measure Description: The percentage of participants flagged as high-risk for hypertension by the Huawei wearable platform within the total recruited screening cohort. Unit of Measure: Percentage of total participants

    Time frame: Month 3 through Month 12 (during community-based wearable data collection).

  2. Association Between Wearable Digital Biomarkers and ABPM-Confirmed Hypertension Risk

    Measure Description: Adjusted Odds Ratios derived from logistic regression models assessing the relationship between wearable physiological parameters (heart rate, heart rate variability, sleep duration/quality, physical activity, and PPG blood pressure estimates) and ABPM-confirmed hypertension status. Unit of Measure: Adjusted Odds Ratio (OR) with 95% Confidence Intervals

    Time frame: Month 17 through Month 20 (during data cleaning and analytical modelling).

07

Study locations

1 site
08

References and documents

Publications

  • Stergiou GS, Menti A, Asayama K, Kollias A, Parati G, Schutte AE, Wang J, Aristizabal D, Asmar R, Bilo G, Bothe T, Clark C, Kario K, Li Y, McManus R, Ohkubo T, Palatini P, Picone D, Shimbo D, Tsaganos T, De La Sierra A. Wearable wrist-watch type cuff oscillometric blood pressure monitors: consensus statement by the European Society of Hypertension Working Group on blood pressure monitoring. J Hypertens. 2026 Oct 1;44(10):1721-1731. doi: 10.1097/HJH.0000000000004415. Epub 2026 Aug 26. PubMed 42644439 ↗
  • Stergiou GS, Menti A, Asmar R, Bilo G, Ntineri A, Palatini P, Parati G, Shennan A, Wang JG, Sierra A, Kollias A, Schutte AE; STRIDE BP and European Society of Hypertension Working Group on Blood Pressure Monitoring.. Updated practical guide for validation studies of automated cuff blood pressure monitors according to the Universal Standard by the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (ISO 81060-2:2018) and Amendments 1:2020 and 2:2024. J Hypertens. 2026 Oct 20. doi: 10.1097/HJH.0000000000004448. Online ahead of print. PubMed 42853222 ↗
  • Stergiou GS, Kario K, Aristizabal D, Beheiry H, Cho MC, Colombari DSA, Itoh H, Jafar TH, Jones E, Li Y, Romero CA, Steckelings UM, Williams B, Borghi C, Charchar F, Doku A, Dorobantu M, Flynn J, Khan N, Kollias A, Kreutz R, Mahmud A, Mancia G, Parati G, Poulter N, Reckelhoff J, Renna N, Shehab A, Schlaich M, Schutte A, Teo BW, Tomaszewski M, Touyz R, Wang J, Weber T, Whelton P, Zhang Y. 2026 International Society of Hypertension Global Hypertension Practice Guidelines. J Hypertens. 2026 Oct 20. doi: 10.1097/HJH.0000000000004451. Online ahead of print. PubMed 42909506 ↗
  • Chia J, Bhatia KS, Mihailidou AS, Kanagaratnam LB. The Role of Ambulatory Blood Pressure Monitoring in Current Clinical Practice. Heart Lung Circ. 2022 Oct;31(10):1333-1340. doi: 10.1016/j.hlc.2022.06.670. Epub 2022 Aug 4. PubMed 35934633 ↗
  • Islam SMS, Chow CK, Daryabeygikhotbehsara R, Subedi N, Rawstorn J, Tegegne T, Karmakar C, Siddiqui MU, Lambert G, Maddison R. Wearable cuffless blood pressure monitoring devices: a systematic review and meta-analysis. Eur Heart J Digit Health. 2022 May 2;3(2):323-337. doi: 10.1093/ehjdh/ztac021. eCollection 2022 Jun. PubMed 36713001 ↗
  • McEvoy JW, McCarthy CP, Bruno RM, Brouwers S, Canavan MD, Ceconi C, Christodorescu RM, Daskalopoulou SS, Ferro CJ, Gerdts E, Hanssen H, Harris J, Lauder L, McManus RJ, Molloy GJ, Rahimi K, Regitz-Zagrosek V, Rossi GP, Sandset EC, Scheenaerts B, Staessen JA, Uchmanowicz I, Volterrani M, Touyz RM; ESC Scientific Document Group. 2024 ESC Guidelines for the management of elevated blood pressure and hypertension. Eur Heart J. 2024 Oct 7;45(38):3912-4018. doi: 10.1093/eurheartj/ehae178. No abstract available. PubMed 39210715 ↗
  • Odeh VA, Chen Y, Wang W, Ding X. Recent Advances in the Wearable Devices for Monitoring and Management of Heart Failure. Rev Cardiovasc Med. 2024 Oct 28;25(10):386. doi: 10.31083/j.rcm2510386. eCollection 2024 Oct. PubMed 39484130 ↗
  • Stergiou GS, Menti A, Mariglis D, Kollias A. The quest for accurate wearable blood pressure monitors. Hypertens Res. 2026 Mar;49(3):1025-1029. doi: 10.1038/s41440-025-02410-w. Epub 2025 Nov 5. PubMed 41193706 ↗
  • Wang Y, Zhou SS, Liu YQ, Li DD, Hu SY, Wang X, Yi L, Yu YN, Chen YD. Accessibility and usage patterns of wearable devices among Chinese adults: the Huawei Blood Pressure Health Study. Eur Heart J Digit Health. 2025 Aug 5;6(6):1264-1272. doi: 10.1093/ehjdh/ztaf088. eCollection 2025 Nov. PubMed 41267836 ↗

Individual participant data

Plan to share: Yes — De-identified individual participant data (IPD) collected during the study will be shared with qualified external researchers. The specific data elements to be shared include: Demographic and Baseline Characteristics: De-identified participant age, biological sex, baseline height, weight, body mass index (BMI), and baseline clinical risk factors. Wearable Sensor and Digital Biomarker Data: Continuous physiological, activity, sleep, heart rate, heart rate variability, and photoplethysmography (PPG) data streams acquired directly from the Huawei wearables via the Huawei Research Platform. Clinical Validation and Reference Data: Matched 24-hour Ambulatory Blood Pressure Monitoring (ABPM) confirmation results, clinical hypertension diagnoses, and algorithm risk-scoring outputs generated by the Huawei platform. Participant Experience Data: De-identified scores and responses from post-monitoring usability and device acceptance questionnaires.

Supporting information: Study protocol, Statistical analysis plan, Informed consent form

Time frame: Start Date: Data will become available starting 6 months following primary publication of the study results in a peer-reviewed journal. End Date: Data will remain accessible for up to 5 years following initial release.

Access criteria: Where/How to Access: Data will be made available via a secure institutional data repository or upon direct written application to the Principal Investigator. Access Request Process: Qualified researchers must submit a formal scientific proposal outlining the intended use, statistical methodology, and public health relevance. Data Use Agreement (DUA): Requesters must sign a formal Data Use Agreement (DUA) that strictly prohibits any attempt to re-identify participants or share data with unauthorized third parties. Ethical Approval: Requests must include proof of Institutional Review Board (IRB) / Ethics Committee approval or exemption from the requester's home institution. Data Governance \& Compliance: All released data files will be fully anonymized in strict compliance with the Malaysian Personal Data Protection Act (PDPA) and institutional data governance frameworks.

09

Timeline

1 registry update since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reached

Start is estimated for Nov 2026; primary completion for Oct 2028, 23 months later.

How these figures are worked out, and which studies are left out of them.

Registered
Oct 28, 2026
First posted
Nov 3, 2026
StartEst.
Nov 3, 2026
Primary completionEst.
Oct 31, 2028
CompletionEst.
Dec 31, 2028
Last update
Nov 3, 2026
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
Registered
First appeared on the registry. No changes since
Nov 3, 2026
Show all 1 update
  1. Nov 3, 2026
    First appeared on the registry

From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗

10

Registry details

Key details

Study ID
NCT07913581
Lead sponsor
Sunway University
Collaborators
Huawei Device Co., Ltd
Responsible party
YookChin Chia (Professor, Sunway University) — Principal investigator
First posted
Nov 3, 2026
Start date
Nov 3, 2026 (estimated)
Primary completion
Oct 31, 2028 (estimated)
Completion
Dec 31, 2028 (estimated)
Last update
Nov 3, 2026

Study contacts

Yook Chin Chia, MBBS FRCP FAFPM ISHF
principal investigator · Sunway University
Yee How Say, BSc PhD
principal investigator · Sunway University

Oversight

Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

No contact was published for this record. The registry link below has the sponsor’s details.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion