ClinicalTrials.gg
RecruitingNCT07770425AccuMeasureUpdated Aug 18, 2026

Lesion Size Measurement During Gastrointestinal Endoscopies

An observational study in Polyp of Colon and Crohn Disease, sponsored by Centre hospitalier de l'Université de Montréal (CHUM). Recruiting at 1 site in Canada. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2026-08-18.

Sponsored by Centre hospitalier de l'Université de Montréal (CHUM) · Observational

From the registry’s dates

  • Started May 2025; still recruiting 1 year 6 months later.
Study type
Observational
Model
Other
Time perspective
Prospective
Enrollment
3,000
Ages
18 Years and older
Sex
All
01

Study summary

The goal of this prospective observational study is to assess the accuracy and reliability of laser readings obtained through AccuMeasure, in comparison to other measurements performed by gastroenterologists. AccuMeasure is a novel technology, that has emerged as a promising tool for measuring polyps and lesions during colonoscopies. The system employs laser-based measurements, enabling precise determination of lesion size, depth, and extent. The main hypotheses this study aims to evaluate are:

  • AccuMeasure technology, with its precise laser measurements, will demonstrate superior accuracy and reliability in assessing lesion size of pathologies encountered during endoscopies, when compared to other endoscopic scoring methods.
  • AccuMeasure measurements will show strong construct validity by correlating significantly with endoscopic subscores, symptomatic remission (CD PRO2 \<8, partial mayo score), and fecal calprotectin values.
Read the detailed description

Data will be gathered during standard of care endoscopies conducted at CHUM by board-certified gastroenterologists or supervised trainees. Patients will undergo preparation based on the latest guidelines, receive sedation according to clinical standards, and undergo clinical decision and surveillance following standard of care, unaffected by study participation.

An initial visual estimation of lesion size will be performed by endoscopists without instruments, relying on their visual assessment of the intestinal lining for signs of inflammation, ulceration, strictures, or abnormalities during colonoscopy. Subsequently, the AccuMeasure will be employed for lesion size measurement. AccuMeasure sizes will be obtained for six groups of lesions: (1) ulcer size in patients with Crohn's disease or ulcerative colitis, (2) Ulcerative Colitis related lesions, (3) polyps, (4) non-IBD ulcers and erosions and inflammatory lesions, (5) Barrett's and associated lesions, and (6) other GI lesions will be measured.

02

Conditions studied

  • Polyp of Colon
  • Crohn Disease
03

In context

Colonic Polyps

377 studies on the registry are indexed under Colonic Polyps; 57 are open to participants now.

This study's planned enrollment of 3,000 is above the median of 411 across 115 observational studies indexed under Colonic Polyps.

Browse Colonic Polyps studies →

Lead sponsor

Centre hospitalier de l'Université de Montréal (CHUM) is the lead sponsor of 376 studies on the registry; 110 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No
Sampling method
Non-probability sample

Study population

All eligible patients presenting at the CHUM for an endoscopy will be approached for this study.

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Adult patients (18 years and older)
  • Patients undergoing gastrointestinal endoscopy procedures

Exclusion criteria

Exclusion Criteria:

  • Minors: Patients under 18 years of age.
  • Patients who do not provide .
  • Patients undergoing endoscopy on an emergency basis (defined as urgent diagnostic or therapeutic endoscopy performed on the gastrointestinal (GI) tract to address potentially life-threatening conditions or severe symptoms that require immediate medical attention).
  • An (ASA) physical status classification greater than 3.
Terms in these criteria, in plain language(2)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

ASA physical status

The anaesthetists’ scale of health before surgery: I is healthy, II has a mild illness that is under control, III a severe one, IV a severe illness that is a constant threat to life. V and VI are used for the critically ill and for organ donors.

05

Study design

Observational model
Other
Time perspective
Prospective
Enrollment
3,000 participants (estimated)
Patient registry
No
06

What researchers measure

Primary outcomes

  1. Validity of AccuMeasure when measuring ulcer size in patients with Crohn's disease or ulcerative colitis

    The validity of AccuMeasure measurements of ulcer size in patients with Crohn's disease or ulcerative colitis is assessed through a correlation coefficient of ≥0.7 between AccuMeasure measurements and traditional scoring methods (SES-CD, CDEIS, mayo endoscopic score), symptomatic remission (CD PRO2 \< 8, partial mayo score), and fecal calprotectin levels

    Time frame: During the endoscopy

  2. Reliability of AccuMeasure when measuring ulcer size in patients with Crohn's disease or ulcerative colitis

    The reliability of AccuMeasure measurements for ulcer size in patients with Crohn's disease or ulcerative colitis is assessed through an Intraclass Correlation Coefficient (ICC) of ≥0.8, that ensures consistent measurements intra- and inter- different raters

    Time frame: During the endoscopy

  3. Correlation between AccuMeasure and Endoscopic Disease Activity when measuring ulcer size in patients with Crohn's disease or ulcerative colitis

    An equivalence test between Endoscopic Disease Activity (visual analogue scale, 100-point scale) and AccuMeasure measurements for ulcer size in patients with Crohn's disease or ulcerative colitis will determine this correlation

    Time frame: During the endoscopy

  4. Relative Inaccuracy of Visual Estimation Compared to AccuMeasure (Laser-Based Device) for Ulcer Size in Patients with Crohn's Disease or Ulcerative Colitis

    A single outcome is reported: the relative inaccuracy (%) of visual estimation compared to AccuMeasure. This outcome is calculated from two measurements taken during the same endoscopy - the visual estimation value and the AccuMeasure value - combined using the following formula: Relative inaccuracy (%) = \|Visual estimation value - AccuMeasure value\| / AccuMeasure value × 100 A superiority z-test will compare this relative inaccuracy against the 9% threshold to assess whether AccuMeasure is superior to visual estimation. Unit of Measure : Percentage of relative inaccuracy (%)

    Time frame: During the endoscopy

  5. Relative Inaccuracy of Snare-Based Measurement Compared to AccuMeasure for Ulcer Size in Patients with Crohn's Disease or Ulcerative Colitis

    Ulcer size will be measured using AccuMeasure (laser-based device, reference method) and using size estimation using the snare tip as a visual reference, during the same endoscopic procedure. Relative inaccuracy will be calculated as: \|Snare-Based Measurement value - AccuMeasure value\| / AccuMeasure value, expressed as a percentage. A superiority z-test against a 9% threshold will assess whether AccuMeasure is superior in accuracy. Unit of Measure : Percentage of relative inaccuracy (%)

    Time frame: During the endoscopy

  6. Relative Inaccuracy of Forceps-Based Measurement Compared to AccuMeasure for Ulcer Size Measurement in Patients with Crohn's Disease or Ulcerative Colitis

    Ulcer size will be measured using AccuMeasure (laser-based device, reference method) and using size estimation using forceps as a visual reference, during the same endoscopic procedure. Relative inaccuracy will be calculated as: \|Forceps-Based Measurement value - AccuMeasure value\| / AccuMeasure value, expressed as a percentage. A superiority z-test against a 9% threshold will assess whether AccuMeasure is superior in accuracy. Unit of Measure : Percentage of relative inaccuracy (%)

    Time frame: During the endoscopy

  7. Relative Inaccuracy of AI-Based Measurement Compared to AccuMeasure for Ulcer Size Measurement in Patients with Crohn's Disease or Ulcerative Colitis

    Ulcer size will be measured using AccuMeasure (laser-based device, reference method) and using an AI model analyzing lesion size from images/videos obtained during the procedure, during the same endoscopic procedure. Relative inaccuracy will be calculated as: \|AI-Based Measurement value - AccuMeasure value\| / AccuMeasure value, expressed as a percentage. A superiority z-test against a 9% threshold will assess whether AccuMeasure is superior in accuracy. Unit of Measure : Percentage of relative inaccuracy (%)

    Time frame: During the endoscopy

Secondary outcomes

  1. Change in AccuMeasure (Laser-Based Device)-Measured Ulcer Size Between Baseline and Follow-Up Endoscopy in Patients with Inflammatory Bowel Disease

    A single outcome is reported: the change in ulcer size (mm), measured using AccuMeasure (laser-based measurement device), between an initial endoscopy and a subsequent follow-up endoscopy performed after a change in medical management (e.g., medication change). The change will be compared using paired t-tests or Wilcoxon signed-rank tests, to assess whether AccuMeasure measurements are responsive to changes in disease activity over time. Unit of Measure : Millimeters (mm), change from baseline

    Time frame: From baseline endoscopy to follow-up endoscopy, up to 2 years

  2. Correlation Between AccuMeasure (Laser-Based Device)-Measured Ulcer Size and Occurrence of Medication Escalation in Patients with Inflammatory Bowel Disease

    Correlation between two measures assessed at/after the index endoscopy: Ulcer size (mm), measured using AccuMeasure (laser-based measurement device) at the index endoscopy. Occurrence of a medication change/escalation in disease management (yes/no), assessed via medical record review, occurring in the 6 to 12 months following the index endoscopy. Unit of Measure : Correlation coefficient (AccuMeasure ulcer size in mm vs. occurrence of medication escalation, yes/no)

    Time frame: 6 to 12 months after the index endoscopy

  3. Correlation Between AccuMeasure (Laser-Based Device)-Measured Ulcer Size and Occurrence of Disease-Related Complications in Patients with Inflammatory Bowel Disease

    Correlation between two measures: Ulcer size (mm), measured using AccuMeasure (laser-based measurement device) at the index endoscopy. Occurrence of a disease-related complication (yes/no), assessed via medical record review, occurring in the 6 to 12 months following the index endoscopy. Unit of Measure : Correlation coefficient (AccuMeasure ulcer size in mm vs. occurrence of disease-related complication, yes/no)

    Time frame: 6 to 12 months after the index endoscopy

  4. Association Between AccuMeasure-Measured Ulcer Size and Hospitalization in Patients with Inflammatory Bowel Disease

    Correlation between AccuMeasure-measured ulcer size (in mm) at the index endoscopy and occurrence of hospitalization related to inflammatory bowel disease, occurring in the 6 to 12 months following the index endoscopy. Unit of Measure : Correlation coefficient (AccuMeasure size in mm vs. occurrence of outcome)

    Time frame: 6 to 12 months after the index endoscopy

  5. Relative Inaccuracy of Visual Estimation Compared to AccuMeasure for Ulcerative Colitis-Related Lesions Size Measurement

    For ulcerative colitis-related lesions, size will be measured using AccuMeasure (laser-based device, reference method) and using unaided visual estimation by the endoscopist, without instruments, during the same endoscopic procedure. Relative inaccuracy will be calculated as: \|Visual Estimation value - AccuMeasure value\| / AccuMeasure value, expressed as a percentage. A superiority z-test against a 10% threshold will assess whether AccuMeasure is superior in accuracy for this lesion group. Unit of Measure : Percentage of relative inaccuracy (%)

    Time frame: During the endoscopy

  6. Relative Inaccuracy of Snare-Based Measurement Compared to AccuMeasure for Ulcerative Colitis-Related Lesions Size Measurement

    For ulcerative colitis-related lesions, size will be measured using AccuMeasure (laser-based device, reference method) and using size estimation using the snare tip as a visual reference, during the same endoscopic procedure. Relative inaccuracy will be calculated as: \|Snare-Based Measurement value - AccuMeasure value\| / AccuMeasure value, expressed as a percentage. A superiority z-test against a 10% threshold will assess whether AccuMeasure is superior in accuracy for this lesion group. Unit of Measure : Percentage of relative inaccuracy (%)

    Time frame: During the endoscopy

  7. Relative Inaccuracy of Forceps-Based Measurement Compared to AccuMeasure for Ulcerative Colitis-Related Lesions Size Measurement

    For ulcerative colitis-related lesions, size will be measured using AccuMeasure (laser-based device, reference method) and using size estimation using forceps as a visual reference, during the same endoscopic procedure. Relative inaccuracy will be calculated as: \|Forceps-Based Measurement value - AccuMeasure value\| / AccuMeasure value, expressed as a percentage. A superiority z-test against a 10% threshold will assess whether AccuMeasure is superior in accuracy for this lesion group. Unit of Measure : Percentage of relative inaccuracy (%)

    Time frame: During the endoscopy

  8. Relative Inaccuracy of AI-Based Measurement Compared to AccuMeasure for Ulcerative Colitis-Related Lesions Size Measurement

    For ulcerative colitis-related lesions, size will be measured using AccuMeasure (laser-based device, reference method) and using an AI model analyzing lesion size from images/videos obtained during the procedure, during the same endoscopic procedure. Relative inaccuracy will be calculated as: \|AI-Based Measurement value - AccuMeasure value\| / AccuMeasure value, expressed as a percentage. A superiority z-test against a 10% threshold will assess whether AccuMeasure is superior in accuracy for this lesion group. Unit of Measure : Percentage of relative inaccuracy (%)

    Time frame: During the endoscopy

  9. Relative Inaccuracy of Visual Estimation Compared to AccuMeasure for Polyps Size Measurement

    For polyps, size will be measured using AccuMeasure (laser-based device, reference method) and using unaided visual estimation by the endoscopist, without instruments, during the same endoscopic procedure. Relative inaccuracy will be calculated as: \|Visual Estimation value - AccuMeasure value\| / AccuMeasure value, expressed as a percentage. A superiority z-test against a 10% threshold will assess whether AccuMeasure is superior in accuracy for this lesion group. Unit of Measure : Percentage of relative inaccuracy (%)

    Time frame: During the endoscopy

  10. Relative Inaccuracy of Snare-Based Measurement Compared to AccuMeasure for Polyps Size Measurement

    For polyps, size will be measured using AccuMeasure (laser-based device, reference method) and using size estimation using the snare tip as a visual reference, during the same endoscopic procedure. Relative inaccuracy will be calculated as: \|Snare-Based Measurement value - AccuMeasure value\| / AccuMeasure value, expressed as a percentage. A superiority z-test against a 10% threshold will assess whether AccuMeasure is superior in accuracy for this lesion group. Unit of Measure : Percentage of relative inaccuracy (%)

    Time frame: During the endoscopy

  11. Relative Inaccuracy of Forceps-Based Measurement Compared to AccuMeasure for Polyps Size Measurement

    For polyps, size will be measured using AccuMeasure (laser-based device, reference method) and using size estimation using forceps as a visual reference, during the same endoscopic procedure. Relative inaccuracy will be calculated as: \|Forceps-Based Measurement value - AccuMeasure value\| / AccuMeasure value, expressed as a percentage. A superiority z-test against a 10% threshold will assess whether AccuMeasure is superior in accuracy for this lesion group. Unit of Measure : Percentage of relative inaccuracy (%)

    Time frame: During the endoscopy

07

Study locations

1 of 1 sites recruiting
08

References and documents

Individual participant data

Plan to share: Yes — Individual participant data that underlie the results reported in research articles based on this study, after de-identification (text, tables, figures and appendices).

No publications or documents are linked to this record.

09

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Started May 2025 (actual). Primary completion is estimated for May 2027, 24 months after the start.

Of 52 non-industry observational studies under Colonic Polyps, half reached primary completion within 16 months of starting (the median), counting those still running; a quarter within 10 and three quarters within 90. This study's planned 24 months is above that.

Counting every sponsor, half of 62 studies reached it within 19 months; a quarter within 10 and three quarters within 90.

How these figures are worked out, and which studies are left out of them.

Registered
Nov 17, 2025
First posted
Aug 18, 2026
StartActual
May 9, 2025
Primary completionEst.
May 2027
CompletionEst.
Nov 2027
Last update
Aug 18, 2026
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Aug 18, 2026, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT07770425
Responsible party
Sponsor
First posted
Aug 18, 2026
Start date
May 9, 2025
Primary completion
May 2027 (estimated)
Completion
Nov 2027 (estimated)
Last update
Aug 18, 2026

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

No contact was published for this record. The registry link below has the sponsor’s details.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion