ClinicalTrials.gg
RecruitingNCT07670039REFACTUpdated Nov 23, 2026

Reliability and Reproducibility of CT-Based Facet Joint Measurements in Patients With AOSpine Type A2, A3, and A4 Thoracolumbar Fractures

An observational study in Facet Joint Arthritis, Facet Joints; Degeneration and Facet Joint Disease, sponsored by Sklifosovsky Institute of Emergency Care. Recruiting at 1 site in Russia. Open to participants aged 18 Years to 65 Years. Per ClinicalTrials.gov, last updated 2026-11-23.

Sponsored by Sklifosovsky Institute of Emergency Care · Observational

How we know

From the registry’s dates

  • Started Oct 2026; still recruiting 1 month later.
Updated Nov 23, 2026Now RecruitingSite recruiting status changed+3 moreGo to Updates ↓

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Study type
Observational
Model
Other
Time perspective
Retrospective
Enrollment
12
Ages
18 Years to 65 Years
Sex
All
01

Study summary

The Reliability Evaluation of Facet joint Assessment by Computed Tomography in thoracolumbar fractures (REFACT) study aims to evaluate how consistently different specialists assess thoracolumbar facet joints on computed tomography (CT) images in patients with AOSpine type A2, A3, or A4 thoracolumbar fractures.

The main questions are:

  • How consistently do different raters classify facet joint degeneration using the Pathria grading system?
  • How consistently do different raters measure facet joint angle and mean facet joint space width on CT images?
  • How reproducible are these assessments when the same rater repeats the measurements after a one-month interval?

The study will use anonymized retrospective CT DICOM datasets obtained from the institutional imaging archive. Six independent raters (three neurosurgeons and three radiology specialists) will evaluate the same CT datasets using a standardized measurement protocol. Each rater will perform two independent assessment rounds separated by a one-month washout period. The results will be used to determine the inter-rater and intra-rater reliability of qualitative and quantitative CT-based facet joint assessment methods.

Read the detailed description

The Reliability Evaluation of Facet joint Assessment by Computed Tomography in thoracolumbar fractures (REFACT) study is an imaging-based, multirater reliability study designed to evaluate the reproducibility of computed tomography-based assessment of thoracolumbar facet joints.

The study represents the methodological stage of a broader research program investigating longitudinal degenerative changes in the facet joints after surgical or conservative treatment of thoracolumbar fractures. Before changes in facet joint morphology can be interpreted over time, the reliability of the imaging assessment methods must first be established in the target patient population.

Anonymized CT DICOM datasets will be selected from the institutional imaging archive of the Sklifosovsky Research Institute for Emergency Medicine. The datasets will include patients with AOSpine type A2, A3, or A4 thoracolumbar junction fractures and will cover the anatomical levels required for standardized facet joint assessment. No additional imaging, patient contact, study-specific treatment, or prospective clinical intervention will be performed.

Six independent raters will participate in the study: three neurosurgeons and three specialists in radiology or CT imaging. All raters will use the same standardized assessment protocol and the same DICOM viewing software.

Before the formal assessment, the raters will participate in a joint training session using one representative anonymized CT dataset that will not be included in the main analysis. The session will be used to demonstrate the assessment procedure, standardize image orientation and vertebral level identification, clarify the interpretation of the Pathria grading system, and review the procedures for measuring facet joint angle and facet joint space width. Any ambiguities in the assessment instructions will be resolved before the formal study begins.

During the first assessment round, each rater will independently evaluate the same anonymized CT datasets. The order of the datasets will be randomized separately for each rater. Raters will record the Pathria grade of facet joint degeneration and quantitative facet joint measurements according to the standardized protocol.

After a one-month washout interval, the same CT datasets will be re-randomized and reassessed independently by the same six raters during a second assessment round. The changed order and washout period are intended to reduce recall bias and allow evaluation of the reproducibility of repeated assessments by the same rater.

Throughout both assessment rounds, raters will be blinded to patient identifiers, clinical information, previous measurements, and the assessments of the other raters. Raters will not discuss individual study cases or measurement decisions until both rounds have been completed.

The study will evaluate agreement across different raters and the consistency of repeated assessments by the same rater. The assessment will include both ordinal grading of facet joint degeneration and continuous morphometric measurements. Exploratory analyses may examine whether reliability differs according to rater specialty, vertebral level, or anatomical side.

All study data will be entered into a standardized data collection form and stored in a restricted-access institutional database. Missing, technically inadequate, or non-evaluable assessments will not be imputed and will be reported descriptively.

Because the study uses only previously acquired, anonymized imaging data, participants will not undergo any study-related procedures and will not be exposed to additional radiation or treatment-related risk.

02

Conditions studied

  • Facet Joint Arthritis
  • Facet Joints; Degeneration
  • Facet Joint Disease
  • Intervertebral Disk Degeneration
  • Pathria Classification

Keywords

  • Thoracolumbar Spine
  • Facet Joint
  • Intervertebral Disc
  • Computed Tomography
  • interobserver reliability
  • intraobserver reliability
03

In context

Intervertebral Disc Degeneration

462 studies on the registry are indexed under Intervertebral Disc Degeneration; 100 are open to participants now.

This study's planned enrollment of 12 is below the median of 119 across 170 observational studies indexed under Intervertebral Disc Degeneration.

Browse Intervertebral Disc Degeneration studies →

Lead sponsor

Sklifosovsky Institute of Emergency Care is the lead sponsor of 13 studies on the registry; 7 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years to 65 Years
Sexes eligible
All
Accepts healthy volunteers
No
Sampling method
Non-probability sample

Study population

The study population will consist of patients aged 18 to 50 years with AOSpine type A2, A3, or A4 thoracolumbar fractures whose previously acquired CT examinations are available in the institutional imaging archive. Eligible CT datasets must cover vertebral levels T9 through L3 and be suitable for standardized facet joint assessment. The study will use anonymized retrospective imaging data only; there will be no direct patient recruitment, additional imaging, treatment allocation, or other study-specific intervention. CT datasets will be selected according to predefined eligibility criteria until at least 142 evaluable facet joints are available for analysis.

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • patient age from 18 to 50 years;
  • thoracolumbar fracture classified as AOSpine type A2, A3, or A4;
  • availability of CT images covering vertebral levels from Th9 to L3;
  • absence of imaging artifacts at the levels planned for assessment.

Exclusion criteria

Exclusion Criteria:

  • bone density of the thoracolumbar junction vertebrae below 100 HU;
  • systemic bone or joint disorders associated with changes in the FJs or intervertebral discs, including diffuse idiopathic skeletal hyperostosis, ankylosing spondylitis, rheumatoid arthritis, or other comparable conditions;
  • previous spinal surgery, including procedures performed without implants;
  • fractures with distraction or translational injury of the posterior supporting column.
05

Study design

Observational model
Other
Time perspective
Retrospective
Enrollment
12 participants (estimated)
Patient registry
No

Groups and cohorts

  • CT Image Review Cohort

    Anonymized CT scans of the thoracolumbar spine (T9-L3) obtained from eligible patients aged 18 to 65 years and reviewed independently by six raters to assess inter-rater and intra-rater reproducibility of CT-based evaluation of facet joint and intervertebral disc degenerative changes

    Diagnostic Test: Computed Tomography Image Review

Interventions

  • Diagnostic testComputed Tomography Image Review

    Independent review of anonymized thoracolumbar CT scans by six raters for assessment of degenerative changes in facet joints and intervertebral discs using the Pathria scale, as well as measurement of facet joint space width and angulation.

06

What researchers measure

Primary outcomes

  1. Interobserver Reliability of CT-Based Pathria Grading Scale for Facet Joint Degenerative Changes

    Interobserver agreement for grading facet joint degenerative changes on thoracolumbar CT scans using the 4-grade Pathria classification, assessed by Fleiss' kappa across six raters.

    Time frame: At baseline CT image review

  2. Interobserver reliability of facet joint space width measurements

    Interobserver reliability of quantitative measurement of mean facet joint space width assessed using the intraclass correlation coefficient.

    Time frame: At baseline CT image review

  3. Interobserver reliability of facet joint angulation measurements

    Interobserver reliability of measurement of facet joint angulation in the axial plane on thoracolumbar CT scans, assessed using the intraclass correlation coefficient.

    Time frame: At baseline CT image review

Secondary outcomes

  1. Intraobserver Reliability of CT-Based Pathria Grading Scale for Facet Joint Degenerative Changes

    Intraobserver agreement for grading facet joint degenerative changes on thoracolumbar CT scans using the 4-grade Pathria classification, assessed on repeated review.

    Time frame: At baseline and 1 month later

  2. Intraobserver reliability of facet joint space width measurements

    Intraobserver reliability of repeated quantitative measurement of mean facet joint space width, assessed using the intraclass correlation coefficient.

    Time frame: At baseline and 1 month later

  3. Intraobserver reliability of facet joint angulation measurements

    Intraobserver reliability of repeated measurement of facet joint angulation in the axial plane on thoracolumbar CT scans, assessed using the intraclass correlation coefficient.

    Time frame: At baseline and 1 month later

07

Study locations

1 of 1 sites recruiting
  • Sklifosovsky Research Institute for Emergency Medicine
    Moscow, 129090, Russia
    Recruiting
    • Vasiliy Karanadze, MD, PhD · Contactsklif@zdrav.mos.ru · +7 (495) 280-15-61
    • Andrey Grin, MD, PhD · Principal investigator
    • Aleksandr Talypov, MD, PhD · Sub investigator
    • Anton Kordonsky, MD, PhD · Sub investigator
    • Vasily Karandze, MD, PhD · Sub investigator
    • Ivan Lvov, MD, PhD · Sub investigator
    • Mikhail Kucherov, MD · Sub investigator
    • Rinat Abdrafiev, MD · Sub investigator
    • Aleksandr Tupikin, MD · Sub investigator
    • Layla Khamidova, MD, PhD · Sub investigator
    • Roman Elokhovskiy, MD, PhD · Sub investigator
    • Ksenia Dmitrenko, MD · Sub investigator
    • Maria Nanoyan, MD · Sub investigator
    • Olga Minkina, MD · Sub investigator
08

References and documents

Individual participant data

Plan to share: No

No publications or documents are linked to this record.

09

Timeline

1 registry update since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedDate before it movedWhere the date was before it moved

Started Oct 2026 (actual). Primary completion is estimated for Jan 2027, 3 months after the start.

Since we started tracking on Sep 25, 2026, the dates moved once, on Nov 23, 2026: start Aug 2026 → Oct 2026, primary completion Nov 2026 → Jan 2027 and completion Dec 2026 → Jan 2027.

Earlier changes are on the record history on ClinicalTrials.gov ↗

How these figures are worked out, and which studies are left out of them.

Registered
Jun 16, 2026
First posted
Jun 25, 2026
StartActual
Oct 1, 2026was Aug 2026
Primary completionEst.
Jan 1, 2027was Nov 2026
CompletionEst.
Jan 1, 2027was Dec 2026
Last update
Nov 23, 2026
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
Status
Not yet recruiting→Recruiting
changed Nov 23, 2026
Sites
Sklifosovsky Research Institute for Emergency Medicine is now Recruiting
Nov 23, 2026
Start date
Aug 1, 2026→Oct 1, 2026 (actual)
Nov 23, 2026
Primary completion
Nov 1, 2026→Jan 1, 2027
Nov 23, 2026
Study completion
Dec 1, 2026→Jan 1, 2027
Nov 23, 2026
Show all 1 update
  1. Nov 23, 2026
    Not yet recruiting→Recruiting
    Sklifosovsky Research Institute for Emergency Medicine is now Recruiting
    Start date Aug 1, 2026→Oct 1, 2026 (now actual)
    Primary completion Nov 1, 2026→Jan 1, 2027
    Study completion Dec 1, 2026→Jan 1, 2027

From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗

10

Registry details

Key details

Study ID
NCT07670039
Lead sponsor
Sklifosovsky Institute of Emergency Care
Responsible party
Ivan Lvov, MD, PhD (External investigator, Sklifosovsky Institute of Emergency Care) — Principal investigator
First posted
Jun 25, 2026
Start date
Oct 1, 2026
Primary completion
Jan 1, 2027 (estimated)
Completion
Jan 1, 2027 (estimated)
Last update
Nov 23, 2026

Study contacts

Ivan Lvov, PhD
Contact
dr.speleolog@gmail.com
+34 654 902 306
Vasiliy Karanadze, PhD
Contact
karanadzevneuro@gmail.com
+7 903 565-68-30

Oversight

Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

Contact study team

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion