An observational study in Cataract and Intraocular Lens, sponsored by Burapha University. Completed at 1 site in Thailand. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2026-03-30.
Sponsored by Burapha University · Observational
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
This study aim to evaluate the agreement of ocular biometric parameters and intraocular lens between two devices (OA-2000 and Pentacam AXL) in patients with cataract.
Participants will be measured ocular biometric parameters once with each device in a random order by the same experienced operator.
This study was conducted as a prospective cross-sectional study to evaluate Agreement of ocular biometry and intraocular lens power between swept-source optical coherence tomography with Placido-disc topography (OA-2000) and Scheimpflug tomography with partial coherence interferometry (Pentacam AXL) in cataract patients The study performed at the Ophthalmology Outpatient Department, Burapha University Hospital, Chonburi, Thailand. The study protocol adhered to the tenets of the Declaration of Helsinki and received formal approval from the Institutional Review Board, Burapha University. Prior to the commencement of any measurements, all participants acknowledged comprehensive study information and provided written informed consent.
A total of 94 participants, aged 18 years or older, diagnosed with cataracts and scheduled for cataract surgery, were enrolled. Exclusion criteria included history of corneal trauma, prior ocular surgery, the use of contact lenses within two weeks of measurement, and the presence of other concurrent ocular pathologies. For each participant, right eye was preferentially selected for analysis; left eye was only utilized if right eye met any of the predefined exclusion criteria.
Measurement protocol Both devices, OA-2000 and Pentacam AXL Wave were calibrated daily before clinical use to ensure technical accuracy. All measurements were performed by one experienced examiner to eliminate inter-observer variability. Participants were instructed on proper head positioning and fixation, with a complete blink prior to each automated image capture. Measurements were obtained once for each device, with the sequence of instrumentation determined in a random order. The study evaluated several ocular biometric parameters: flat keratometry (K1), steep keratometry (K2), mean keratometry (Km), corneal astigmatism, vector analysis (J0 and J45), ACD, WTW, and AL. For the calculation of IOL power, The Acrysof SN60WF model (Alcon Laboratories, Fort Worth, Texas, USA) was used as the reference, utilizing the keratometric index of 1.3375. IOL power calculations were performed using three distinct formulas: SRK/T, Barrett Universal II, and Hoffer Q.
1,635 studies on the registry are indexed under Cataract; 233 are open to participants now.
This study's enrollment of 94 is close to the median of 90 across 477 observational studies indexed under Cataract.
Browse Cataract studies →Burapha University is the lead sponsor of 15 studies on the registry; 3 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Participants diagnosed with cataracts and scheduled for cataract surgery at the Ophthalmology Outpatient Department, Burapha University Hospital, Chonburi, Thailand
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Patients with cataract who were scheduled for cataract surgery
Device: Swept-source optical coherence tomography with Placido-disc topography · Device: Scheimpflug tomography with partial coherence interferometry
Measurement technology using swept-source optical coherence tomography with Placido-disc topography
Also known as: OA-2000
Measurement technology using Scheimpflug tomography with partial coherence interferometry
Also known as: Pentacam AXL
Agreement of Intraocual lens power between OA-2000 and Pentacam AXL in cataract patients
Intraocular lens power calculated using SRK/T, Barrett Universal II, and Hoffer Q formulas in diopters
Time frame: Immediately after participating in the study
Agreement of flat keratometery(K1) between OA-2000 and Pentacam AXL in cataract patients
flat keratometery(K1) in diopters
Time frame: Immediately after participating in the study
Agreement of steep keratometry(K2) between OA-2000 and Pentacam AXL in cataract patient
steep keratometry(K2) in diopters
Time frame: Immediately after participating in the study
Agreement of mean keratometry(Km) between OA-2000 and Pentacam AXL in cataract patient
Mean keratometry(Km) in diopters
Time frame: Immediately after participating in the study
Agreement of anterior chamber depth (ACD) between OA-2000 and Pentacam AXL in cataract patients
Anterior chamber depth (ACD) in millimeters
Time frame: Immediately after participating in the study
Agreement of white-to-white distance (WTW) between OA-2000 and Pentacam AXL in cataract patients
White-to-white distance (WTW) in millimeters
Time frame: Immediately after participating in the study
Agreement of axial lenght (AL) between OA-2000 and Pentacam AXL in cataract patients
Axial lenght (AL) in millimeters
Time frame: Immediately after participating in the study
Agreement of corneal astigmatism between OA-2000 and Pentacam AXL in cataract patients
corneal astigmatism in diopters
Time frame: Immediately after participating in the study
Agreement of J0 between OA-2000 and Pentacam AXL in cataract patients
J0 is vector analysis of corneal astigmatism; measures astigmatism at 90° and 180°
Time frame: Immediately after participating in the study
Agreement of J45 between OA-2000 and Pentacam AXL in cataract patients
J45 is vector analysis of corneal astigmatism; measures astigmatism at 45° and 135°
Time frame: Immediately after participating in the study
Plan to share: Yes — IPD used in the results publication
Supporting information: Study protocol
Time frame: IPD and supporting information will be available one year after publicaiton and for two years period.
Access criteria: Direct contact to corresponding author
Ran from Sep 2024 to primary completion in Nov 2024, 2 months.
How these figures are worked out, and which studies are left out of them.
This study is completed, as verified in Mar 2026. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Burapha University