Pseudophakic Eyes With Presbyopia-correcting IOLs: OCT Biometry and Pyramid Aberrometry

An observational study in Cataract, sponsored by Prim. Prof. Dr. Oliver Findl, MBA. Recruiting at 2 sites in Austria. Open to participants aged 21 Years to 110 Years. Per ClinicalTrials.gov, last updated 2026-02-27.

Sponsored by Prim. Prof. Dr. Oliver Findl, MBA · Observational

From the registry’s dates

  • Primary completion was expected by Apr 2026, 7 months ago, but the record still lists the study as recruiting.
  • Started Apr 2024; still recruiting 2 years 7 months later.
Study type
Observational
Model
Cohort
Time perspective
Prospective
Enrollment
80
Ages
21 Years to 110 Years
Sex
All
01

Study summary

To correlate ocular morphology from anterior segment OCT and pyramid wavefront sensing in order to comprehensively analyze pseudophakic in vivo image quality of presbyopia-correcting IOLs in cataract patients.

Read the detailed description

Improvements in cataract surgery and the introduction of different intraocular lenses (IOLs) have transformed the operation from a simple therapeutic procedure to a refractive surgical procedure. A large number of currently available IOL designs are not limited to correcting refractive errors and astigmatism, but can also compensate for corneal sphericity and/or moderate presbyopia by inducing multifocality or extending the depth of focus.

The three-dimensional representation of the anterior segment of the eye has been facilitated in eye surgery by the introduction of optical coherence tomography (OCT), and imaging techniques such as spectral domain OCT (SD-OCT) and swept-source OCT (SS OCT) are particularly well suited for the quantitative characterization of eye dimensions. This offers the possibility of creating biometric eye models and using the non-paraxial regime for characterizing eye optics.

Similarly, the introduction of ocular wavefront aberrometry at the turn of the millennium led to a paradigm shift in the evaluation of clinical optical imaging quality and the derivation of objective optical metrics. Furthermore, internal lens aberrations can be quantified by direct subtraction from anterior segment tomography. However, high-resolution eye tomography and wavefront aberrometry are rarely comprehensively linked.

A pyramidal wavefront sensor (PWS) Osiris-T (CSO, Italy) was recently introduced, which can measure the ocular wavefront with a significantly higher lateral resolution. In addition, tomographic parameters of the anterior segment can be imported directly into the device to examine the clinical optical performance of IOL implants. This provides the ability to combine 3-D OCT biometry of the anterior segment and high-resolution wavefront aberrometry.

A total of 160 eyes of 80 patients will be included.

02

Conditions studied

  • Cataract

Browse trials for

Keywords

  • Intraocular Lenses
  • Pyramid wavefront
  • Pyramid Aberrometry
03

In context

Cataract

1,629 studies on the registry are indexed under Cataract; 235 are open to participants now.

This study's planned enrollment of 80 is below the median of 89 across 475 observational studies indexed under Cataract.

Browse Cataract studies →

Lead sponsor

Prim. Prof. Dr. Oliver Findl, MBA is the lead sponsor of 39 studies on the registry; 3 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
21 Years to 110 Years
Sexes eligible
All
Accepts healthy volunteers
No
Sampling method
Non-probability sample

Study population

80 cataract patients (160 eyes)

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  1. Men and women aged above 21 years with prior uncomplicated cataract/IOL exchange surgery
  2. Willing to sign before measurements
  3. Corrected distance visual acuity (CDVA) of 0.1 logMAR or better
  4. Absence of corneal scars/dry eye disease that could falsify the light transmission of the study eye
  5. Total absence of posterior capsule opacification or patients who already have undergone Nd:YAG capsulotomy
  6. Absence of ocular comorbidity (Macular degeneration, glaucoma, amblyopia)

Exclusion criteria

Exclusion Criteria:

  1. Prior corneal refractive or ocular surgery
  2. Posterior capsule opacification.
  3. Keratometry between \<42.5 and >45 D,
  4. Corneal spherical aberration > 0.4 microns 5) Angle kappa > 0.4 mm

6) Zonular weakness 7) Pseudoexfoliation syndrome 8) Eccentric fixation or insufficient ability to fixate (tremor, nystagmus) 9) Pregnancy

Terms in these criteria, in plain language(1)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

05

Study design

Observational model
Cohort
Time perspective
Prospective
Enrollment
80 participants (estimated)
Patient registry
No

Groups and cohorts

  • Acrysoft SN60WF (Alcon) - Control

    Aspheric monofocal

    Device: Osiris-T Pyramid Wavefront Sensor - (CSO, Italy)

  • Acrysoft IQ Vivity (Alcon)

    Refractive EDOF

    Device: Osiris-T Pyramid Wavefront Sensor - (CSO, Italy)

  • AT Lisa Tri (Carl Zeiss Meditec AG)

    Diffractive multifocal

    Device: Osiris-T Pyramid Wavefront Sensor - (CSO, Italy)

  • Tecnis Symphony ZXR00 (Johnson & Johnson)

    Diffractive aspheric extended depth of focus

    Device: Osiris-T Pyramid Wavefront Sensor - (CSO, Italy)

  • Tecnis Eyhance ICB00 (Johnson & Johnson)

    Enhanced monofocal

    Device: Osiris-T Pyramid Wavefront Sensor - (CSO, Italy)

  • RayOne EMV (Rayner Surgical)

    Enhanced monofocal

    Device: Osiris-T Pyramid Wavefront Sensor - (CSO, Italy)

  • Acunex Varo AN6V (Teleon Surgical)

    Rotationally asymmetric multifocal extended depth of focus

    Device: Osiris-T Pyramid Wavefront Sensor - (CSO, Italy)

  • PureSee (Johnson & Johnson)

    Refractive EDOF

    Device: Osiris-T Pyramid Wavefront Sensor - (CSO, Italy)

  • RayOne Trifocal (Rayner)

    Diffractive Multifocal

    Device: Osiris-T Pyramid Wavefront Sensor - (CSO, Italy)

Interventions

  • DeviceOsiris-T Pyramid Wavefront Sensor - (CSO, Italy)

    The Osiris-T aberrometer is a CE-certified device that operates via a high-resolution four-faced pyramid wavefront sensor (PWS) to analyze light intensity among four images (sub-apertures) of the patients ́entrance pupil akin to a Foucault knife-edge test. Thereby measurements of the wavefront and refractive error can be quantified non-invasively. The sampling density of the wavefront error is 45,000 points at maximum pupil. The device uses a near-infrared extended light-emitting diode source emitting at 850 nm. Its is additionally intertwined with a corneal topography system to also characterize the corneal aberrations and compute via direct subtraction the internal ocular optics.

06

What researchers measure

Primary outcomes

  1. IOL ocular optics measument

    To measure the internal ocular optics of patients with presbyopia-correcting IOLs via 3-D anterior segment OCT biometry and pyramid wavefront sensing by employing the following optical metrics higher-order aberrations (HOAs, unit: root means square)

    Time frame: 24 months

Secondary outcomes

  1. Comparison of clinical optical quality and device measurements

    Correlate and compare clinical optical quality via defocus curves (by employing trial lenses to the best distance prescription, starting from +0.50 to -3.00 diopters (D), in -0.50-D steps) to virtual ray traced aberrations from anterior segment OCT as well as physically measured wavefront aberrations with the pyramid wavefront sensor. Wavefront data will thereby be also employed to analyze the fidelity of virtual ray traced aberrations from anterior segment OCT and measured wavefront aberrations with the pyramid wavefront sensor.

    Time frame: 24 months

  2. Higher-order aberrations in non-dilated and dilated pupils

    Changes in higher-order aberrations (unit: root mean square) will be evaluated before and after pharmacological dilation of pupils

    Time frame: 24 months

  3. Non-dilated and dilated Pupil centration

    Changes in pupil centration (unit: mm) will be evaluated before and after pharmacological dilation

    Time frame: 24 months

  4. Correlation and Comparison of IOL decentration

    Correlate and compare IOL decentration measured with the pyramid-wavefront sensor to IOL decentration and tilt measured with 3-D anterior segment OCT.

    Time frame: 24 months

07

Study locations

2 of 2 sites recruiting
  • Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital Vienna
    Vienna, 1140, Austria
    Recruiting
    • Stefan Georgiev, MD, PhD · Contact+43 1 91021
  • Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital Vienna
    Vienna, 1140, Austria
    Recruiting
08

References and documents

Individual participant data

Plan to share: Undecided

No publications or documents are linked to this record.

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Feb 27, 2026, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT07436247
Lead sponsor
Prim. Prof. Dr. Oliver Findl, MBA
Responsible party
Prim. Prof. Dr. Oliver Findl, MBA (Principal Investigator, Vienna Institute for Research in Ocular Surgery) — Sponsor-investigator
First posted
Feb 27, 2026
Start date
Apr 4, 2024
Primary completion
Apr 1, 2026 (estimated)
Completion
Jul 1, 2026 (estimated)
Last update
Feb 27, 2026

Study contacts

Stefan Georgiev, MD, PhD
Contact
office@viros.at
+43 1 91021 ext. 57564
Oliver Findl, Prof., Dr.
Contact
office@viros.at
+43 1 91021 ext. 57564
Oliver Findl, Prof., Dr.
principal investigator · Vienna Institute for Research in Ocular Surgery

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

Contact study team

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion