Not yet recruitingNCT07117292VIRGO-CMUpdated Aug 12, 2025

Assessing the Validity and Reliability of IMU Systems and a Goniometer in Cervical Motion (VIRGO-CM)

An interventional study of Xsens DOT and Trigno Avanti Sensors in Cervical Spine Motion Assessment in Healthy Adults, sponsored by European University Cyprus. Not yet recruiting at 1 site in Cyprus. Open to participants aged 18 Years to 40 Years, including healthy volunteers. Per ClinicalTrials.gov, last updated 2025-08-12.

Sponsored by European University Cyprus · Not applicable, Interventional, and Diagnostic

Phase
Not applicable
Study type
Interventional
Enrollment
18
Allocation
Not applicable
Ages
18 Years to 40 Years
Sex
All
01

Study summary

This study aims to evaluate how accurate and reliable two wearable sensor systems (inertial measurement units or IMUs) and a goniometer are in measuring cervical spine (neck) motion. Healthy adult volunteers will be asked to perform simple head movements in different directions while being assessed using the devices. The goal is to compare how closely these tools agree with each other and how consistently they record motion across repeated tests. This information will help determine whether the sensors are suitable for use in clinical settings to assess neck movement in future patient populations.

Read the detailed description

This interventional validation study will assess the concurrent validity and test-retest reliability of two inertial measurement unit (IMU) systems (Xsens DOT and Trigno Avanti) and a universal goniometer in measuring multi-planar cervical motion. A within-subject design will be used, with participants performing standardized active cervical range of motion (AROM) tasks in flexion, extension, lateral flexion, and rotation. All measurements will be conducted in a biomechanics lab setting under controlled conditions.

Each participant will undergo three testing sessions:

Familiarization session (optional)

Test session 1

Test session 2

Primary outcomes will include:

Peak angular displacement in each movement plane

Inter-device agreement (validity)

Intra-device test-retest consistency (reliability)

Sensor placement will follow anatomical landmarks based on previous biomechanical research. The IMUs and goniometer will be used simultaneously to compare measurements. Data analysis will involve intraclass correlation coefficients (ICC), standard error of measurement (SEM), and Bland-Altman plots for agreement analysis.

The study will recruit 20-30 healthy adults aged 18-40 with no current or past neck injury. The results will inform future clinical applications of wearable sensors in cervical spine assessment, particularly for populations with neck pain or neuromusculoskeletal disorders.

Ethical approval has been granted by the Cyprus National Bioethics Committee (Approval: ΕΕΒΚ ΕΠ 2025.01.231), and all participants will provide written informed consent.

02

Conditions studied

  • Cervical Spine Motion Assessment in Healthy Adults

Keywords

  • Inertial Measurement Units (IMUs)
  • Cervical Spine
  • Wearable Sensors
  • Validity
  • Reliability
03

In context

Lead sponsor

European University Cyprus is the lead sponsor of 15 studies on the registry; 3 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years to 40 Years
Sexes eligible
All
Accepts healthy volunteers
Yes

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Healthy adults aged 18 to 40 years
  • Able to understand and follow instructions
  • Provided

Exclusion criteria

Exclusion Criteria:

  • History of cervical spine pathology, trauma, or surgery
  • Presence of neck pain, musculoskeletal, neurological, or vestibular disorders
  • Use of medications affecting sensorimotor function
  • Pregnancy
  • Any condition that may interfere with safe participation or data accuracy
Terms in these criteria, in plain language(1)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

05

Study design

Phase
Not applicable
Primary purpose
Diagnostic
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
18 participants (estimated)

Study arms

  • Experimental
    Experimental: Sensor-Based Motion Assessment

    Participants will undergo two testing assessments of cervical spine motion using three devices: Xsens DOT (IMU), Trigno Avanti (IMU), and a universal goniometer. The aim is to assess the validity and reliability of the sensor systems.

    Device: Xsens DOT · Device: Trigno Avanti Sensors · Device: Universal Goniometer

Interventions

  • DeviceXsens DOT

    Wearable inertial sensor used to capture cervical range of motion in three planes.

  • DeviceTrigno Avanti Sensors

    Wearable inertial sensor used to capture cervical range of motion in three planes.

  • DeviceUniversal Goniometer

    Standard clinical tool used to measure cervical spine motion angles manually.

06

What researchers measure

Primary outcomes

  1. Agreement in Cervical Range of Motion between IMUs and Goniometer

    Assessment of the validity of two inertial measurement units (Xsens DOT and Trigno Avanti) compared to a universal goniometer in measuring active cervical spine range of motion across flexion/extension, lateral flexion, and axial rotation using Bland-Altman analysis.

    Time frame: Day 1 (single-session assessment)

  2. Test-Retest Reliability of IMU Systems in Cervical Range of Motion

    Evaluation of intra-session and inter-session test-retest reliability of Xsens DOT and Trigno Avanti inertial sensors in measuring active cervical range of motion (CROM) across three planes (flexion/extension, lateral flexion, rotation). Reliability will be quantified using intraclass correlation coefficients (ICC) and standard error of measurement (SEM).

    Time frame: Day 1 (two repeated assessments within same session)

07

Study locations

1 site
08

References and documents

Study documents

PDFs hosted by the registry, ClinicalTrials.gov.

Individual participant data

Plan to share: Yes — De-identified individual participant data (IPD), including cervical range of motion measurements and sensor-derived outputs, will be made available upon reasonable request for secondary analysis. Data will be shared via a secure university repository or data-sharing platform following study completion and publication.

Supporting information: Study protocol, Statistical analysis plan, Informed consent form

Time frame: De-identified individual participant data (IPD) and supporting documents will be available beginning 6 months after publication of the main findings and will remain accessible for a minimum of 5 years.

Access criteria: Access to the IPD and supporting materials will be granted to qualified researchers affiliated with academic or research institutions for non-commercial use. Requests should be submitted to the principal investigator and will be evaluated based on the scientific merit of the proposal. Data will be shared via secure transfer through institutional repositories or encrypted platforms.

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Aug 12, 2025, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT07117292
Lead sponsor
European University Cyprus
Collaborators
Brunel University
Responsible party
George Pamboris (Assistant Professor of Biomechanics and Rehabilitation, European University Cyprus) — Principal investigator
First posted
Aug 12, 2025
Start date
Aug 2025 (estimated)
Primary completion
Dec 2026 (estimated)
Completion
Dec 2026 (estimated)
Last update
Aug 12, 2025

Study contacts

George M. Pamboris, PhD
Contact
G.Pamboris@euc.ac.cy
+35799336357

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is not yet recruiting, as verified in Aug 2025. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion