CClinicalTrials.gg
RecruitingNCT06911528EDGEUpdated Apr 4, 2025

Application of EndoScell Intraoperative Cellular Probing Technology for Early-Stage Breast Cancer

An interventional study of EndoScell Scaner (ES) novel intraoperative cellular probing technology in Breast Cancer, Sentinel Lymph Node and Frozen Section, sponsored by Fudan University. Recruiting at 1 site in China. Open to female participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2025-04-04.

Sponsored by Fudan University · Not applicable, Interventional, and Diagnostic

From the registry’s dates

  • Primary completion was expected by Dec 2025, 9 months ago, but the record still lists the study as recruiting.
  • Registered 1 year 1 month after the study started (first participant enrolled Jan 2024, registered Mar 2025).
  • Started Jan 2024; still recruiting 2 years 8 months later.
Phase
Not applicable
Study type
Interventional
Enrollment
709
Allocation
Not applicable
Ages
18 Years and older
Sex
Female
01

Study summary

Sentinel Lymph Node Biopsy (SLNB) is a common surgical treatment for breast cancer and a primary method for assessing the pathological status of axillary lymph nodes. Precise intraoperative detection of sentinel lymph nodes during surgery assists in timely evaluation of axillary lymph node pathology and helps in formulating further treatment strategies.

Touch imprint cytology (TIC) is one of the most commonly used intraoperative detection techniques. The new intraoperative cellular detection technology, EndoScell Scanner (ES), uses an improved real-time miniaturized fluorescence microscopy system for image acquisition. The ultra-high-resolution images obtained can reach the cellular level. In previous studies, the accuracy and sensitivity of this technology for intraoperative detection of sentinel lymph nodes were comparable to imprint cytology, but it is much more rapid. The detection technology uses fluorescein sodium and methylene blue as fluorescent dyes, which is non-invasive and also non-consumptive of tissue samples.

This study involves patients scheduled for sentinel lymph node biopsy and aims to evaluate the clinical application value of the EndoScell Scanner (ES) for intraoperative assessment of the pathological status of sentinel lymph nodes through a prospective self-controlled study. To avoid the potential impact of methylene blue on the ES detection technology, we will use mitoxantrone as a new dye for sentinel lymph node tracing in this study.

The primary study objective is to compare the accuracy of the ES detection technology in assessing sentinel lymph node status, using paraffin pathology examination as the gold standard. The primary endpoint is the accuracy of the ES technology. Secondary endpoints include the image quality score of the ES detection, the learning curve of the surgeons, and the time required for detection.

Read the detailed description

In recent years, the incidence of breast cancer in China has risen rapidly. Over the past two decades, the annual average incidence rate has increased from 15 per 100,000 to about 30 per 100,000. In first-tier cities like Shanghai, the incidence rate even exceeds 60 per 100,000, making breast cancer the leading malignant tumor threatening women's health. Compared to Western countries, the onset age of breast cancer in Chinese women is relatively younger, with over 54% of cases occurring before menopause. Surgery remains the mainstay of comprehensive treatment for breast cancer. Nearly half of the patients require mastectomy due to the extent or location of the tumor, resulting in significant disfigurement and long-term psychological trauma. In recent years, the demand for postoperative breast appearance among breast cancer patients in China has been increasing, leading to a rise in the proportion of conventional breast-conserving surgery, breast-conserving surgery, and various types of breast reconstruction surgeries.

Breast-conserving surgery combined with postoperative radiotherapy can improve the postoperative breast appearance and quality of life while achieving tumor safety equal to or even better than that of total mastectomy. Breast-conserving oncoplastic surgery, which combine the principles of conventional breast conservation with plastic surgery techniques, further enhance the feasibility and safety of breast-conserving surgery.

The development of breast-conserving oncoplastic surgery has created a more urgent need to ensure negative margins intraoperatively. Despite expanding surgical indications due to the application of oncoplastic techniques, the positive margin rate of breast-conserving oncoplastic surgery is not significantly different from that of conventional breast-conserving surgery, ranging from 5% to 15%. Although re-excision after a positive margin does not affect local recurrence risk, it significantly diminishes postoperative cosmetic outcomes. More importantly, the design of oncoplastic surgery incisions becomes a challenge if mastectomy is needed based on margin status. Currently, the most accurate method for margin assessment is postoperative margin staining followed by radial sectioning and paraffin pathology examination. To enable timely intraoperative margin assessment, various methods have been proposed, including intraoperative frozen section analysis, specimen X-ray photography, and micro-computed tomography. However, these methods require ex vivo specimen evaluation and have limited sensitivity. Small sample studies have used micro-PET/CT technology for specimen imaging, but its high cost prevents widespread clinical validation and application.

The EndoScell Scaner (ES) is a novel intraoperative cell detection technology that uses a modified real-time miniaturized fluorescence microscope system for image acquisition, achieving ultra-high resolution at the cellular level. Previous studies have shown that its accuracy and sensitivity in intraoperative sentinel lymph node detection are comparable to those of cytological imprinting but with greater speed. This technology employs sodium fluorescein and methylene blue as fluorescent dyes, is non-invasive, and does not consume tissue samples.

This study aims to evaluate the clinical value of the EndoScell Scaner (ES) novel intraoperative cell probing technology for intraoperative margin assessment in patients undergoing conventional breast-conserving surgery and breast-conserving oncoplastic surgery combined with sentinel lymph node biopsy. The primary objective is to compare the accuracy of ES technology in assessing margin status and sentinel lymph node status using paraffin pathology as the gold standard. The primary endpoints are the accuracy of ES technology, positive margin rate, and reoperation rate; the secondary endpoints are ES detection image quality score, learning curve of surgeons, and detection time.

02

Conditions studied

  • Breast Cancer
  • Sentinel Lymph Node
  • Frozen Section
  • Cytology

Browse trials for

Keywords

  • Breast carcinoma
  • sentinel lymph node
  • tracer
  • touch imprint cytology
  • epifluorescence widefield microscope system
03

In context

Breast Neoplasms

12,544 studies on the registry are indexed under Breast Neoplasms; 2,892 are open to participants now.

This study's planned enrollment of 709 is above the median of 72 across 9,303 interventional studies indexed under Breast Neoplasms.

Browse Breast Neoplasms studies →

Lead sponsor

Fudan University is the lead sponsor of 1,270 studies on the registry; 623 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
Female
Accepts healthy volunteers
No

Inclusion criteria

  • Age 18 years and older (inclusive)
  • Female
  • Preoperative pathology confirmed invasive breast carcinoma or ductal carcinoma in situ
  • Scheduled for sentinel lymph node biopsy
  • Capable of and willing to provide informed consent

Exclusion criteria

Exclusion Criteria:

  • Patients with a confirmed allergy to methylene blue or sodium citrate tracers
  • Pregnant or lactating women
  • Patients unwilling to participate in the clinical study
05

Study design

Phase
Not applicable
Primary purpose
Diagnostic
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
709 participants (estimated)

Study arms

  • Experimental
    Intraoperative Assessment

    After screening and enrollment, the EndoScell Scaner (ES) novel intraoperative cellular probing technology will be used for intraoperative evaluation of the sentinel lymph node. Concurrently, imprint cytology will be performed for evaluation. During the study period, intraoperative decisions will primarily reference the results of the imprint cytology technique.

    Procedure: EndoScell Scaner (ES) novel intraoperative cellular probing technology

Interventions

  • ProcedureEndoScell Scaner (ES) novel intraoperative cellular probing technology

    In this project, we utilize the miniature wide-angle focusing microscope for intraoperative cell-level observation and detection, a technology in which our hospital has conducted extensive research and accumulated rich experience.

06

What researchers measure

Primary outcomes

  1. The accuracy of ES technology

    the accuracy of the ES technology (including accuracy, sensitivity and specificity)

    Time frame: After the final pathological results are obtained, it is usually about 2 weeks after surgery

  2. The reoperation rate

    The proportion of reoperations due to a positive margin

    Time frame: 3 months after surgery

Secondary outcomes

  1. The quality score of ES imaging

    The image quality of ES was scored by the pathologist

    Time frame: After the final pathological results are obtained, it is usually about 2 weeks after surgery

  2. The learning curve of the surgeons

    Evaluate the number of cases required for the surgeon to achieve 95% or more accuracy

    Time frame: through study completion, an average of 1 year

  3. The time required for the intraoperative evaluation

    The time required for intraoperative detection using ES technology

    Time frame: through study completion, an average of 1 year

07

Study locations

1 of 1 sites recruiting
  • Fudan University Shanghai Cancer Center
    Shanghai, Shanghai 200032, China
    Recruiting
08

References and documents

Individual participant data

Plan to share: Yes

Supporting information: Study protocol

No publications or documents are linked to this record.

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Apr 4, 2025, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT06911528
Lead sponsor
Fudan University
Responsible party
Jiong Wu (Professor, Fudan University) — Principal investigator
First posted
Apr 4, 2025
Start date
Jan 30, 2024
Primary completion
Dec 31, 2025 (estimated)
Completion
Dec 31, 2025 (estimated)
Last update
Apr 4, 2025

Study contacts

Jiajian Chen, Doctor
Contact
elwin1020@163.com
+8618017317219

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

Contact study team

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion