Neonatal Oximeter Bias Study

An observational study in Neonatal Respiratory Distress and Oxygenation, sponsored by Czech Technical University in Prague. Not yet recruiting at 1 site in Czechia. Per ClinicalTrials.gov, last updated 2025-03-25.

Sponsored by Czech Technical University in Prague · Observational

From the registry’s dates

  • Primary completion was expected by Aug 2025, 1 year 2 months ago, but the record still lists the study as not yet recruiting.
Study type
Observational
Model
Cohort
Time perspective
Prospective
Enrollment
40
Sex
All
01

Study summary

The study aims to determine if there is a systematic difference (bias) between pulse oximeters used in control systems for automated oxygen delivery (A-FiO2) and those used in monitoring systems.

When using A-FiO2 systems there are commonly two oximeter probes on the infant with two difference readouts. Nurses report frustration that the two readings are often markedly different. It is understandable that physiological differences between sensor sites might reflect different regional oxygen saturation levels. It is also possible that there is a relevant systematic bias between difference monitors and sensors.

Therefore, a large systematic multicenter study is needed to determine whether these frequent differences should be ignored as physiological noise or considered clinically relevant.

Read the detailed description

The accuracy of clinical pulse oximeters is specified as 3% RMS (root mean squared of the bias and variance) compared to arterial SaO2, in the range of 70-100% SpO2. This combines errors from bias and from scatter (imprecision). These validations are carried out under ideal laboratory conditions; that is, on healthy volunteers who undergo experimental desaturations, and not in the routine clinical environment. In a large multicenter clinical observation study, Ross et al in 2013 identified important related concerns. Specifically, they found that many of the clinical measurements were outside the 3% accuracy envelop. Specifically, they reported that bias varied depending on the level of saturation, the oximeter brand, sensor, race and site perfusion. Others have identified relevant differences in oximeters, oximeter sensors [Maiwald], and skin pigmentation.

Our study would be the first study in the neonatal ICU evaluating bias to consider different oximeters, sensors and sensor sites. It is highly topical in that changes in average SpO2 of 3% have been associated with excess neonatal mortality and morbidity.

This study is planned to investigate the source and magnitude of differences in SpO2 readings from oximeter sensors at different sensor sites that are routinely noticed by clinicians. While these differences are most often ignored and attributed to sensor site perfusion, if systematic they could have marked impact on mortality and morbidity.

The aim of the investigation is to provide practical guidance relating to SpO2 bias among oximeters, oximeter sensors and sensor location. While taking advantage of the clinical need for 2 oximeter sensors, the results will be applicable to all neonatal oximeter monitoring.

An observational design was selected to take place in centers using automated FiO2 control systems (A-FiO2) that routinely require the use of one sensor for control and another for monitoring. This is a refinement of the approach used in the often-cited multicenter evaluation of neonatal SpO2 exposure. Thus, without an investigational intervention the observational design is well suited to collect comparable data from multiple centers.

02

Conditions studied

  • Neonatal Respiratory Distress
  • Oxygenation

Browse trials for

Keywords

  • pulse oximetry
  • automated FiO2 control
  • SpO2
03

In context

Pulmonary Atelectasis

377 studies on the registry are indexed under Pulmonary Atelectasis; 93 are open to participants now.

This study's planned enrollment of 40 is below the median of 76 across 100 observational studies indexed under Pulmonary Atelectasis.

Browse Pulmonary Atelectasis studies →

Lead sponsor

Czech Technical University in Prague is the lead sponsor of 36 studies on the registry; 6 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
Child (0–17), Adult (18–64), Older adult (65+)
Sexes eligible
All
Accepts healthy volunteers
No
Sampling method
Non-probability sample

Study population

All infants in the NICU monitored with two simultaneous oximeters with probes in preductal locations. The use of A-FiO2 is expected.

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Observations of any infant in the neonatal ICU with two simultaneous oximeter monitors may be included. The sites' Ethics Committee must review the protocol, approve participation and determine if is required. If required, it might be prospective, that is prior to collecting any data, or retrospective.

Exclusion criteria

Exclusion Criteria:

  • Observations are to be made at the convenience of the Investigative team. They should reflect routine situation, and not be selected to specifically capture problems. Thus, the photo should be taken immediately with both displays are on in the view, and not delayed until something interesting happens. Observations should not be made if any of the following exclusion criteria are meet. If after collection, any of these are meet, the data should not be included as an Observation on the Observation-CRF.

    • One oximeter monitoring post ductal SpO2 in infant with shunt.
    • Monitor and A-FiO2 Oximeter not reading between 70-100%
    • Less than 5 minutes between repeat Observations
    • No more than 5 measurements per day per subject with sensors in same position and same oximeters (i.e., every time either sensor is moved, 5 new Observations can be made that day).
    • Presence of motion artifact
    • Presence of sensor integrity alarms/alerts
Terms in these criteria, in plain language(2)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

Clinically significant

Judged by the study doctor to matter for your health or for the study. It is a doctor’s decision, so ask the study team if you are unsure whether something counts.

05

Study design

Observational model
Cohort
Time perspective
Prospective
Enrollment
40 participants (estimated)
Patient registry
No

Groups and cohorts

  • Infants in the NICU with two oximeters

    Infants in the NICU monitored with two oximeters with probes in preductal locations. The use of A-FiO2 is expected.

06

What researchers measure

Primary outcomes

  1. Bias between paired SpO2 measurements

    Bias between paired SpO2 in three ranges: 1. Hypoxemia (SpO2: 70 - \<89.5%), 2. Normoxemia (SpO2: 89.5-95.5%) 3. Hyperoxemia (SpO2: \>95.5-100%) The ranges are determined as the mean of the two oximeters.

    Time frame: 1 month (250 observations is expected from each participating center; on average 2 patients and 5 observations per day per patient assumed)

Secondary outcomes

  1. Bias between paired SpO2 related to site

    Bias between paired SpO2 (in %) in three ranges related to independent variable: site (as factor).

    Time frame: 1 month (250 observations is expected from each participating center; on average 2 patients and 5 observations per day per patient assumed)

  2. Bias between paired SpO2 related to sensor location

    Bias between paired SpO2 (in %) in three ranges related to independent variable: sensor location (as factor).

    Time frame: 1 month (250 observations is expected from each participating center; on average 2 patients and 5 observations per day per patient assumed)

  3. Bias between paired SpO2 related to oximeter brand pairs

    Bias between paired SpO2 (in %) in three ranges related to independent variable: oximeter brand pairs (as factor).

    Time frame: 1 month (250 observations is expected from each participating center; on average 2 patients and 5 observations per day per patient assumed)

  4. Bias between paired SpO2 related to sensor pairs

    Bias between paired SpO2 (in %) in three ranges related to independent variable: sensor pairs (as factor).

    Time frame: 1 month (250 observations is expected from each participating center; on average 2 patients and 5 observations per day per patient assumed)

  5. Bias between paired SpO2 related to oximeter averaging setting

    Bias between paired SpO2 (in %) in three ranges related to independent variable: oximeter averaging setting (as factor).

    Time frame: 1 month (250 observations is expected from each participating center; on average 2 patients and 5 observations per day per patient assumed)

  6. Bias between paired SpO2 related to skin shade

    Bias between paired SpO2 (in %) in three ranges related to independent variable: skin shade (as factor).

    Time frame: 1 month (250 observations is expected from each participating center; on average 2 patients and 5 observations per day per patient assumed)

07

Study locations

1 site
  • Motol University Hospital, Neonatal Unit
    Prague, 15500, Czechia
08

References and documents

Individual participant data

Plan to share: Undecided

No publications or documents are linked to this record.

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Mar 25, 2025, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT06817850
Lead sponsor
Czech Technical University in Prague
Collaborators
University Hospital, Motol
Responsible party
Sponsor
First posted
Feb 10, 2025
Start date
Mar 15, 2025 (estimated)
Primary completion
Aug 31, 2025 (estimated)
Completion
Oct 31, 2025 (estimated)
Last update
Mar 25, 2025

Study contacts

Jakub Rafl, PhD
Contact
rafl@fbmi.cvut.cz
+420728229991
Thomas E Bachman, MSc
principal investigator · Czech Technical University in Prague
Jan Janota, MD, PhD
principal investigator · Motol University Hospital

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is not yet recruiting, as verified in Mar 2025. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion