ClinicalTrials.gg
RecruitingNCT06647225Updated Apr 8, 2026

Using Artificial Intelligence to Screen for Hip Dysplasia

An interventional study of Artificial intelligence augmented ultrasound in Developmental Dysplasia of Hip, sponsored by Murdoch Childrens Research Institute. Recruiting at 1 site in Australia. Open to participants aged 4 Weeks to 20 Weeks, including healthy volunteers. Per ClinicalTrials.gov, last updated 2026-04-08.

Sponsored by Murdoch Childrens Research Institute · Not applicable, Interventional, and Screening

From the registry’s dates

  • Started Dec 2024; still recruiting 1 year 11 months later.
Phase
Not applicable
Study type
Interventional
Enrollment
240
Allocation
Not applicable
Ages
4 Weeks to 20 Weeks
Sex
All
01

Study summary

The goal of this clinical trial is to learn if an ultrasound scan using artificial intelligence can accurately screen for hip dysplasia. Researchers will compare the artificial intelligence ultrasound results to the standard ultrasound measures to see if the artificial intelligence ultrasound scan can accurately screen for hip dysplasia.

It will also seek to understand how parents feel about their children undergoing this scan.

Participants will:

  • Have an additional ultrasound performed on their child at their scheduled outpatient's appointment for hip dysplasia
  • Complete a short questionnaire about the experience of having the measurement performed on their child
Read the detailed description

Initial screening for Developmental Dysplasia of the Hip (DDH) in Australia is performed most often by general practitioners and paediatricians shortly after birth and by maternal child health care nurses (MCHN) throughout the first year of life. These physical examinations consist of the Ortolani and Barlow tests and the examination of the thigh and gluteal creases. A recent meta-analysis reported the sensitivity of these tests as 36%, which indicates there is potential for a large proportion of cases to go undetected when solely relying on these examinations. Moreover, there currently are no formalised processes by which standards of practice are taught, assessed, or maintained. Thus, there is a clear need for a less operator-dependent screening protocol that can be performed within the current models of infant care. While some countries utilise universal ultrasound screening, this too is limited by access to care, as devices are not portable and thus cannot be used in current care models. Furthermore, it requires a specialist operator, substantially increasing cost. The screening program's limited nature, combined with the need for more consensus among international healthcare providers regarding the best method for managing DDH, has produced highly mixed clinical practices.

One part of the solution is optimising screening protocols for DDH in existing care models. Each state in Australia has established MCHN care protocols that provide access care for young children. While physical screening for DDH in these visits is standard practice, there remains considerable scope for improvement in the accuracy and reliability of these screening methods. Selective screening relies on several clinical associations with DDH to identify which patients receive ultrasound screening. Still, it has been shown to detect only 50% of infants with dysplasia. The MCHN screening program relies on clinical examination alone to detect dysplasia, an inferior identification method. Universal screening has a higher rate of detection of dysplasia but is expensive, single point in time (so misses the development of dysplasia) and results in higher levels of treatment.

A possible solution is portable artificial intelligence (AI)-augmented ultrasound. Recently technology has been developed to support a portable ultrasound device to screen DDH that uses AI-enabled technology to screen for DDH rapidly and accurately. Prior data has demonstrated that physicians and nurses could operate the device following training from expert sonographers. With its low-cost and ease of operation (with simple training) by healthcare providers such as MCHNs, it could significantly augment the physical screening. Thus, there is clear potential for an affordable, repeatable, and accessible screening methodology to be translated into clinical care. Initial Canadian data is promising. Pilot data suggests that DDH detection rates with this technology is on par with the detection rates of orthopaedic specialists. However, as this study was performed in a community setting and only those participants referred to orthopaedic clinics had a standard ultrasound measure performed, this pilot was unable to compare this screening technique with current gold standard diagnostic measures across the whole cohort, nor determine device sensitivity or predictive values. To demonstrate that this technology is fit for purpose, it is imperative that the rate of false negatives is also understood, as this is what will lead to late presentation, - which is what screening ultimately endeavours to prevent. Moreover, in an Australian context an important consideration in a wider roll-out is whether this technology would be accepted for uptake by clinicians and parents.

The proposed project will seek to gather pilot data to assess the validity and feasibility of this technology within a population of infants aged 4-20 weeks flagged at risk for DDH and referred to the Royal Children's Hospital. This will enable the recruitment of a sufficient number of cases of DDH to determine the sensitivity of the device. While the sensitivity and specificity of the device in this at-risk population may not be generalizable to the wider community the information gathered will then inform and refine a larger study of this technology in a community setting such as tertiary (birthing hospitals) and primary (MCHN clinics) care. If it can be demonstrated that it is feasible to implement this technology into existing care models, there is clear scope for this technology to revolutionize DDH screening. Thus, this project seeks to determine how well the device performs (sensitivity, specificity and predictive value) and the the clinical acceptability of this measure within the patient population.

02

Conditions studied

  • Developmental Dysplasia of Hip

Browse trials for

Keywords

  • hip dysplasia
  • artificial intelligence
  • ultrasound
  • screening
  • infants
03

In context

Hip Dislocation

107 studies on the registry are indexed under Hip Dislocation; 36 are open to participants now.

This study's planned enrollment of 240 is above the median of 86 across 64 interventional studies indexed under Hip Dislocation.

Browse Hip Dislocation studies →

Lead sponsor

Murdoch Childrens Research Institute is the lead sponsor of 99 studies on the registry; 34 are open to participants now.

Of its 5 completed or terminated interventional studies of FDA-regulated products, 3 (60%) have results posted.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
4 Weeks to 20 Weeks
Sexes eligible
All
Accepts healthy volunteers
Yes

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Enrolled in the VicHip study
  • Is 4-20 weeks of age at enrolment
  • Is attending The Royal Children's Hospital for the purpose of the potential diagnosis of DDH
  • Has a diagnostic (standard) hip ultrasound on the day of their out-patient appointment
  • Has a legally acceptable representative capable of understanding the document and providing consent on the participant's behalf.

Exclusion criteria

Exclusion Criteria:

Participants will be excluded from enrolment if:

  • They are currently receiving treatment for DDH
Terms in these criteria, in plain language(1)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

05

Study design

Phase
Not applicable
Primary purpose
Screening
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
240 participants (estimated)

Study arms

  • Other
    All active participants

    All participants will undergo an AI-augmented ultrasound and there will be no active comparator

    Device: Artificial intelligence augmented ultrasound

Interventions

  • DeviceArtificial intelligence augmented ultrasound

    The hip ultrasound is performed using a handheld device (Exo Iris) that uses a pocket-sized ultrasound probe and is run through an application on an IoS (Apple mobile) operation system. . A real-time algorithm detects and records the anatomical landmarks. When there are enough images for analysis the operator is notified that the scan is complete.

06

What researchers measure

Primary outcomes

  1. Artificial Intelligence augmented ultrasound screening test capability: Sensitivity

    Artificial intelligence (AI) augmented ultrasound results will be compared to standard ultrasound imaging to calculate sensitivity (\[number of true positive cases detected/(number of true positive cases detected + number of false negative cases detected)\] X 100). Groups will be defined as follows: * True positive cases: Flagged for follow-up after the AI assessment of ultrasound sweeps from the portable probe and have a diagnosis of DDH from traditional ultrasound reports. * False positive cases: Flagged for follow-up after the AI assessment of the ultrasound sweeps and do not have a diagnosis of DDH from the traditional ultrasound reports * False negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and have a diagnosis of DDH from traditional ultrasound reports * True negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and do not have a diagnosis of DDH from traditional ultrasound reports

    Time frame: 1 day, both ultrasound scans will be performed on the same day

  2. Artificial Intelligence augmented ultrasound screening test capability: Specificity

    Artificial intelligence (AI) augmented ultrasound results will be compared to standard ultrasound imaging to calculate specificity (\[number of true negative cases detected/(number of false positive cases detected + number of true negatives cases detected\] X 100). Groups will be defined as follows: * True positive cases: Flagged for follow-up after the AI assessment of ultrasound sweeps from the portable probe and have a diagnosis of DDH from traditional ultrasound reports. * False positive cases: Flagged for follow-up after the AI assessment of the ultrasound sweeps and do not have a diagnosis of DDH from the traditional ultrasound reports * False negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and have a diagnosis of DDH from traditional ultrasound reports * True negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and do not have a diagnosis of DDH from traditional ultrasound reports

    Time frame: 1 day, both ultrasound scans will be performed on the same day

  3. Artificial Intelligence augmented ultrasound screening test capability: Positive predictive value (PPV)

    Artificial intelligence (AI) augmented ultrasound will be compared to standard ultrasound to calculate PPV (\[number of true positive cases detected/(number of true positive cases detected + number of false positive cases predicted) X 100). Groups will be defined as follows: * True positive cases: Flagged for follow-up after the AI assessment of ultrasound sweeps from the portable probe and have a diagnosis of DDH from traditional ultrasound reports. * False positive cases: Flagged for follow-up after the AI assessment of the ultrasound sweeps and do not have a diagnosis of DDH from the traditional ultrasound reports * False negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and have a diagnosis of DDH from traditional ultrasound reports * True negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and do not have a diagnosis of DDH from traditional ultrasound reports

    Time frame: 1 day, both ultrasound scans will be performed on the same day

  4. Artificial Intelligence augmented ultrasound screening test capability: Negative predictive value (NPV)

    Artificial intelligence (AI) augmented ultrasound will be compared to standard ultrasound to calculate NPV \[number of true negative cases detected/(number of false negatives detected + number of true negative cases detected) X 100. Groups will be defined as follows: * True positive cases: Flagged for follow-up after the AI assessment of ultrasound sweeps from the portable probe and have a diagnosis of DDH from traditional ultrasound reports. * False positive cases: Flagged for follow-up after the AI assessment of the ultrasound sweeps and do not have a diagnosis of DDH from the traditional ultrasound reports * False negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and have a diagnosis of DDH from traditional ultrasound reports * True negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and do not have a diagnosis of DDH from traditional ultrasound reports

    Time frame: 1 day, both ultrasound scans will be performed on the same day

Secondary outcomes

  1. Factors associated with differences in device sensitivity

    Sensitivity will be calculated between groups: 1. Degree of dysplasia as defined by the Graf classification 2. Sex 3. Infant age (categorised as 4-7.99 weeks, 8-11.99 weeks, 12-15.99 weeks, 16-20 weeks) 4. Number of scans performed by device operator (less than or greater than 60 scans).

    Time frame: 1 day, all data will be collected from day of scan

  2. Factors associated with differences in device specificity

    Analyses will stratified to look at differences in specificity between groups: 1. Degree of dysplasia as defined by the Graf classification 2. Sex 3. Infant age (categorised as 4-7.99 weeks, 8-11.99 weeks, 12-15.99 weeks, 16-20 weeks) 4. Number of scans performed by device operator (less than or greater than 60 scans).

    Time frame: 1 day, all data will be collected from day of scan

  3. Factors associated with differences in device positive predictive value

    Positive predictive value will be compared between groups: 1. Degree of dysplasia as defined by the Graf classification 2. Sex 3. Infant age (categorised as 4-7.99 weeks, 8-11.99 weeks, 12-15.99 weeks, 16-20 weeks) 4. Number of scans performed by device operator (less than or greater than 60 scans).

    Time frame: 1 day, all data will be collected from day of scan

  4. Factors associated with differences in device negative predictive value

    Negative predictive value will be compared between groups: 1. Degree of dysplasia as defined by the Graf classification 2. Sex 3. Infant age (categorised as 4-7.99 weeks, 8-11.99 weeks, 12-15.99 weeks, 16-20 weeks) 4. Number of scans performed by device operator (less than or greater than 60 scans).

    Time frame: 1 day, all data will be collected from day of scan

  5. Device operator reliability in performing successful scans

    Device operators' reliability will be recorded as percentage of scans performed that return a suboptimal result. This will be done by graphing number of scans performed by operators (operator experience) (x axis) against proportion of sub-optimal scans (y axis) to visually identify if a steady state is achieved.

    Time frame: 12 months or entire study duration

  6. Acquisition of successful scans

    The total proportion of infants unable to be scanned with the Artificial Intelligence augmented ultrasound device and reasons why scans were unsuccessful will from the entire sample. A higher frequency of successful scan acquisition will indicate better device performance.

    Time frame: 12 months or entire study duration

  7. Time taken to acquire scan

    Time to acquire the image will be calculated from the initiation of the scan to the time that the software indicates image acquisition is complete. The time to receive results will be calculated from the time of completion acquisition to the time the final recommendation is provided. A lower successful scan time will be indicative of higher feasibility.

    Time frame: 1 day, calculated at time of scan

  8. Caregiver perspectives on their infant undergoing the artificial intelligence augmented ultrasound

    Caregivers will be asked to answer a purpose-built survey that has been piloted in Canadian studies (3 questions rated from 0-10, where 10 indicates a more positive experience) in addition to Australian-specific closed and open-ended questions.

    Time frame: 1 day, caregivers will be asked to complete immediately following the scan

  9. Operator perspectives on performing the artificial intelligence augmented ultrasound

    Operators will be asked to complete the 10-item System Usability Questionnaire which measures the perceived ease of using technological devices. Scores are calculated on a 5-point Likert scale where 1=Strongly disagree and 5=Strongly agree. A single composite score out of 100 is calculated from all 10 items and indicates the overall useability of the device, where a higher score indicates better useability. In addition to this, two open-ended questions (Are there any further comments you would like to make about what you liked about the device?" and "are there any further comments you would like to make about what you didn't like about the device?") will be asked.

    Time frame: At the conclusion of their involvement in the study device (up to 12 months)

07

Study locations

1 of 1 sites recruiting
08

References and documents

Individual participant data

Plan to share: Undecided — The researchers may choose to share data with other groups that are using the same device, all IPD would be deidentified and would be subject to further ethical approval. The researchers have sought consent from participants to allow data collected to be used for future research.

No publications or documents are linked to this record.

09

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Started Dec 2024 (actual). Primary completion is estimated for Nov 2026, 23 months after the start.

Of 32 interventional studies with no phase under Hip Dislocation, half reached primary completion within 45 months of starting (the median), counting those still running; a quarter within 18. This study's planned 23 months is below that.

How these figures are worked out, and which studies are left out of them.

Registered
Oct 14, 2024
First posted
Oct 17, 2024
StartActual
Dec 6, 2024
Primary completionEst.
Nov 2026
CompletionEst.
Nov 2026
Last update
Apr 8, 2026
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Apr 8, 2026, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT06647225
Lead sponsor
Murdoch Childrens Research Institute
Responsible party
Sponsor
First posted
Oct 17, 2024
Start date
Dec 6, 2024
Primary completion
Nov 2026 (estimated)
Completion
Nov 2026 (estimated)
Last update
Apr 8, 2026

Study contacts

Natalie K Hyde, BBiomedSc (Hons), PhD
Contact
natalie.hyde@mcri.edu.au
61 3 9936 6246
Melissa Formosa
Contact
melissa.formosa@mcri.edu.au
Leo T Donnan
principal investigator · Murdoch Childrens Research Institute

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

Contact study team

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion